<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Others Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-category/biobase/air-protection-products/others-air-protection-products/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-category/biobase/air-protection-products/others-air-protection-products/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Mon, 23 Mar 2026 07:45:22 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>Others Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-category/biobase/air-protection-products/others-air-protection-products/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Animal Water Bottle Washer</title>
		<link>https://keylaser.am/product/animal-water-bottle-washer/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 23 Mar 2026 07:45:22 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14945</guid>

					<description><![CDATA[<p><label>Model: </label>BK-SPQX200</p>
<p>The animal water bottle washer adopts softened water high-pressure spray technology. Through a large-flow circulating pump, the water in the washing chamber circulates in the washing pipeline, and the rotating spray arm evenly sprays water onto the items to be cleaned for powerful rinsing. At the same time, cleaning agent can be automatically added to make the cleaning more effective and thorough. During the cleaning process, the equipment uses clean water in the tank to spray directly onto the water bottles, achieving efficient rinsing effect. It is used for fully automatic spray cleaning of animal water bottles in laboratory animal centers and related units, and can automatically complete the cleaning and rinsing processes.</p>
<p>The post <a href="https://keylaser.am/product/animal-water-bottle-washer/">Animal Water Bottle Washer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BK-SPQX200</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Water Tank Capacity</td>
<td>26L</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Washing Capacity (Baskets/Hour)</td>
<td>1000</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Basket Size</td>
<td>250*500mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Max. Washing Height</td>
<td>450mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Control Panel Type</td>
<td>Touch panel</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Consumption</td>
<td>15.8KW</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power Supply</td>
<td>AC380V, 50Hz, 3Φ (Three-phase&amp;Five-wire system); AC220V, 60Hz(Optional); AC110V, 50/60Hz(Optional, external transformer)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>External Size(W*H*D)</td>
<td>695*671*1440mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size(W*H*D)</td>
<td>750*850*1550mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>150kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Gross Weight</td>
<td>170kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/animal-water-bottle-washer/">Animal Water Bottle Washer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Animal Litter Workstation BK-DS1080H</title>
		<link>https://keylaser.am/product/animal-litter-workstation-bk-ds1080h/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 23 Mar 2026 07:42:30 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14941</guid>

					<description><![CDATA[<p><label>Model: </label>BK-DS1080H</p>
<p>The animal litter workstation is a dedicated device for staff to dump bedding into medical garbage bags or bins. The dumping operation is performed in a negative-pressure area to prevent staff from inhaling dust and contaminated fumes during bedding dumping. This product is an accessory for animal laboratories; it is optional for small-scale animal labs and standard equipment for medium-scale labs.</p>
<p>The post <a href="https://keylaser.am/product/animal-litter-workstation-bk-ds1080h/">Animal Litter Workstation BK-DS1080H</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td colspan="2">Model</td>
<td>BK-DS1080H</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Applicable Number of Users</td>
<td>Single</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">Work Area Dimensions</td>
<td>1060*490*760mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Garbage Dumping Window</td>
<td>400*380mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">Stainless Steel Waste Bucket</td>
<td>500*500mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Fan</td>
<td>550W centrifugal fan adopted</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">Air Volume</td>
<td>≥1000m³/h</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Inlet Air Velocity</td>
<td>≥0.6m/s (Adjustable gear)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">Noise</td>
<td>≤ 62 dB</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Illumination</td>
<td>≥300Lx</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="2">Operating Environment</td>
<td>Temperature</td>
<td>15-30℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Relative Humidity</td>
<td>30-85%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">Standard Accessory</td>
<td>1 exhaust high-efficiency filter (Class H14), 1 exhaust primary filter (Class G4)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Power Supply</td>
<td>AC220V, 50Hz(Standard); AC220V, 60Hz(Optional); AC110V, 50/60Hz(Optional, external transformer)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">External Size(W*H*D)</td>
<td>1080*780*1750mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Package Size(W*H*D)</td>
<td>1300*1000*2000mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">Net Weight</td>
<td>150kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Gross Weight</td>
<td>170kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/animal-litter-workstation-bk-ds1080h/">Animal Litter Workstation BK-DS1080H</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Medical Laminar Flow Bed</title>
		<link>https://keylaser.am/product/medical-laminar-flow-bed/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 09 Oct 2024 15:14:36 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11039</guid>

					<description><![CDATA[<p><strong>Introduction:</strong><br />
The medical laminar flow bed is an air purification device that provides a locally high clean environment for patients with burns, weakened immunity, blood diseases, and those requiring a clean and dust-free environment.</p>
<p>The post <a href="https://keylaser.am/product/medical-laminar-flow-bed/">Medical Laminar Flow Bed</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BLF-01</li>
<li><label>Brand:</label>Biobase</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong><br />
1. With medical device registration certificate.</p>
<p>2. In addition to the traditional button control, the control system also adds a remote control, without reaching to touch the button to achieve remote control.</p>
<p>3. The adjustable air volume system, guarantee the workspace wind speed in the ideal state.</p>
<p>4. UV has anti-touch function, single point UV lamp button can not turn on UV lamp, need to press for 3 seconds to turn on UV lamp, protect patient safety.</p>
<p>5. The workspace using the whole anti-static curtain around, good transparency, it is not easy to dust.</p>
<p>6. FFU adopts domestic famous brand fan, stable performance, low noise.</p>
<p>7. UV lamp and fan, fluorescent lamp interlock function, when the fan, fluorescent lamp work, UV lamp can not be turned on, protect the patient.</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="883" align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td width="284">Model</td>
<td width="571">BLF-01</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="284">Wind Speed</td>
<td width="571">0.1~0.25m/s</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="284">Noise</td>
<td width="571">≤62dB</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="284">Illuminance</td>
<td width="571">≥300lux</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="284">UV Lamp Power</td>
<td width="571">40W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="284">LED Fluorescent Lamp Power</td>
<td width="571">12W*4</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="284">Number of Users</td>
<td width="571">1</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="284">Consumption</td>
<td width="571">1200W</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="284">Supply Power</td>
<td width="571">220V, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="284">Internal Size(W*D*H)</td>
<td width="571">2170*1020*1850mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="284">External Size(W*D*H)</td>
<td width="571">2250*1100*2350mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="284">Package Size(W*D*H)</td>
<td width="571">2360*1260*1010mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="284">Net Weight</td>
<td width="571">320kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="284">Gross Weight</td>
<td width="571">360kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/medical-laminar-flow-bed/">Medical Laminar Flow Bed</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Animal Litter Workstation</title>
		<link>https://keylaser.am/product/animal-litter-workstation/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 09 Oct 2024 15:12:54 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11033</guid>

					<description><![CDATA[<p><strong>Introduction:</strong><br />
It is suitable for the treatment of animal litter in the SPF animal room, to prevent the pollutants generated when dumping the animal litter from harming the experimenters and the working environment, and to provide safety protection for the experimenters and the working environment.</p>
<p>The post <a href="https://keylaser.am/product/animal-litter-workstation/">Animal Litter Workstation</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>DDW-1100</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong><br />
1. Use high-quality materials: the three side walls of the working area adopt high-quality 304 stainless steel integrated structure, and the internal cleanable parts adopt rounded corner design, leaving no dead corners and easy to clean.</p>
<p>2. Strong tolerance: the working area has a large opening, which can accommodate all common animal cages.<br />
3. Control system:Control system:.LCD touch screen design, real-time display of working status, easy to operate.<br />
4. Ergonomic design: help reduce fatigue, improve work efficiency, and provide a safer working environment.</p>
<p>&nbsp;</p>
<figure id="attachment_11034" aria-describedby="caption-attachment-11034" style="width: 577px" class="wp-caption alignnone"><img fetchpriority="high" decoding="async" class="wp-image-11034 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/DDW-1.webp" alt="Animal Litter Workstation" width="577" height="763" srcset="https://keylaser.am/wp-content/uploads/2024/10/DDW-1.webp 577w, https://keylaser.am/wp-content/uploads/2024/10/DDW-1-227x300.webp 227w" sizes="(max-width: 577px) 100vw, 577px" /><figcaption id="caption-attachment-11034" class="wp-caption-text"> </figcaption></figure>
<figure id="attachment_11035" aria-describedby="caption-attachment-11035" style="width: 912px" class="wp-caption alignnone"><img decoding="async" class="wp-image-11035 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/DDW-2.webp" alt="Animal Litter Workstation" width="912" height="679" srcset="https://keylaser.am/wp-content/uploads/2024/10/DDW-2.webp 912w, https://keylaser.am/wp-content/uploads/2024/10/DDW-2-300x223.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/DDW-2-768x572.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/DDW-2-600x447.webp 600w" sizes="(max-width: 912px) 100vw, 912px" /><figcaption id="caption-attachment-11035" class="wp-caption-text"> </figcaption></figure>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="100%" align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td width="332">Model</td>
<td width="551">DDW-1100</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="332">Power Supply</td>
<td width="551">AC220V, 50Hz(Standard); AC110V, 60Hz(Optional)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="332">Instrument Size(L*D*H)</td>
<td width="551">1100*700*1920mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="332">Operating Area Size(L*D*H)</td>
<td width="551">1000*600*660mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="332">Laminar Airflow Velocity</td>
<td width="551">≥0.35m/s</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="332">Noise</td>
<td width="551">≤65dB(A)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="332">Iluminance</td>
<td width="551">≥1000lx</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="332">LED Lamp</td>
<td width="551">12W*2</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="332">Consumption(W)</td>
<td width="551">700W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="332">Primary Filter Size</td>
<td width="551">967*453*30mm*1</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="332">High Efficiency Filter Size</td>
<td width="551">1000*485*69mm*1</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="332">Activated Carbon Filter Size</td>
<td width="551">758*408*35mm*1</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="332">Filtration Efficiency</td>
<td width="551">99.9995%(φ0.12μm)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="332">Ambient Temperature</td>
<td width="551">15℃~35℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="332">Relative Humidity</td>
<td width="551">≤75%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="332">Atmospheric Pressure Range</td>
<td width="551">70kPa~106kPa</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="332">Package Size(L*D*H)</td>
<td width="551">1250*850*2100mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="332">Gross Weight</td>
<td width="551">240kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/animal-litter-workstation/">Animal Litter Workstation</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Laser Dust Particle Counter</title>
		<link>https://keylaser.am/product/laser-dust-particle-counter/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 09 Oct 2024 15:10:05 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11029</guid>

					<description><![CDATA[<p><strong>Application:</strong><br />
The product is widely used in optics, chemistry, food, cosmetics, electronic health, biological products, aerospace and other fields.</p>
<p>The post <a href="https://keylaser.am/product/laser-dust-particle-counter/">Laser Dust Particle Counter</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>CLJ-2803</li>
<li><label>Brand:</label>Biobase</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1. 7-inch touch screen control, friendly interface and convenient operation.</p>
<p>2. Calculated by 95% confidence level (UCL), it can directly display particle concentration (particles/m³) and purification level.</p>
<p>3. 4GB data storage card, data storage management.</p>
<p>4. The material of the chassis is stainless steel.</p>
<p>5. Built-in thermal printer.</p>
<p>6. Imported semiconductor laser tube and imported semiconductor photosensitive receiver tube.<br />
7. Support WIFI to export data directly.</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="100%">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td width="323">Model</td>
<td width="559">CLJ-2803</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="323">Dimension</td>
<td width="559">220*350*260mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="323">Sampling Volume</td>
<td width="559">28.3L/min(1cfm/min)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="323">Ambient Temperature</td>
<td width="559">10~35℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="323">Ambient Relative Humidity</td>
<td width="559">≤75%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="323">Power</td>
<td width="559">150W</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="323">Six Particle Size Channels</td>
<td width="559">0.3μm, 0.5μm,0.7μm,1μm, 2μm,3μm, 5μm, 10μm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="323">Vacuum Source</td>
<td width="559">Built-in air pump, under control flow</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="323">Light Source</td>
<td width="559">Semi-conductor laser, more than 30,000h</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="323">Zero Count</td>
<td width="559">Less than 10min</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="323">Communication Interface</td>
<td width="559">USB, RS485</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="323">Cleanliness Level Range</td>
<td width="559">ISO5~ISO9</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="323">Main Body Material</td>
<td width="559">Stainless steel</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="323">Voltage</td>
<td width="559">110V/220V, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="323">Optional Parts</td>
<td width="559">Temperature sensor, humidity sensor</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="323">Packing Size</td>
<td width="559">460*400*410mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="323">Gross Weight</td>
<td width="559">17kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/laser-dust-particle-counter/">Laser Dust Particle Counter</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Laser Dust Particle Counter 2. 83L/min</title>
		<link>https://keylaser.am/product/laser-dust-particle-counter-2-83l-min/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 09 Oct 2024 15:08:00 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11025</guid>

					<description><![CDATA[<p><strong>Application:</strong><br />
The product is widely used in optics, chemistry, food, cosmetics, electronic health, biological products,aerospace and other fields.</p>
<p>The post <a href="https://keylaser.am/product/laser-dust-particle-counter-2-83l-min/">Laser Dust Particle Counter 2. 83L/min</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>CLJ-2083</li>
<li><label>Brand:</label>Biobase</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1. 7-inch touch screen control, friendly interface and convenient operation.</p>
<p>2. Calculated by 95% confidence level (UCL), it can directly display particle concentration (particles/m³) and purification level.</p>
<p>3. 4GB data storage card, data storage management.</p>
<p>4. The material of the chassis is cold-rolled steel plate(anti-rust treatment, electrostatic spraying)</p>
<p>5. Built-in thermal printer.</p>
<p>6. Imported semiconductor laser tube and imported semiconductor photosensitive receiver tube.<br />
7. The counting result can be converted into cubic meters and cubic feet.</p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="100%" align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td width="358">Model</td>
<td width="524">CLJ-2083</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="358">Dimension</td>
<td width="524">220*280*185mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="358">Sampling Volume</td>
<td width="524">2.83L/min (0. 1cfm/min)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="358">Ambient Temperature</td>
<td width="524">10~35℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="358">Ambient Relative Humidity</td>
<td width="524">≤75%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="358">Power</td>
<td width="524">100W</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="358">Six Particle Size Channels</td>
<td width="524">0.3μm, 0.5μm,1μm, 3μm, 5μm, 10μm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="358">Vacuum Source</td>
<td width="524">Built-in air pump, under control flow</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="358">Light Source</td>
<td width="524">Semi-conductor laser, more than 30,000h</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="358">Zero Count</td>
<td width="524">Less than 10min</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="358">Communication Interface</td>
<td width="524">USB</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="358">Cleanliness Level Range</td>
<td width="524">ISO5~ISO9</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="358">Main Body Material</td>
<td width="524">Cold-rolled steel with powder coated</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="358">Voltage</td>
<td width="524">110V/220V, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="358">Optional Parts</td>
<td width="524">Temperature sensor, humidity sensor</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="358">Packing Size</td>
<td width="524">500*500*350mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="358">Gross Weight</td>
<td width="524">11kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/laser-dust-particle-counter-2-83l-min/">Laser Dust Particle Counter 2. 83L/min</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Duck Isolators</title>
		<link>https://keylaser.am/product/duck-isolators/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 09 Oct 2024 15:06:06 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11020</guid>

					<description><![CDATA[<div><strong>Introduction:</strong></div>
<p>Duck isolators are isolation devices designed specifically for ducks and other poultry, mainly used in animal experiments, veterinary research, disease control, and poultry health management scenarios. The main purpose of isolators is to create a safe and controllable environment to prevent disease transmission, cross infection, and ensure the accuracy of experimental results.</p>
<p>The post <a href="https://keylaser.am/product/duck-isolators/">Duck Isolators</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BCI-II</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong><br />
1. LED digital display with keyboard, real-time display of temperature and humidity, more intuitive.</p>
<p>2. Equipped with an automatic temperature control system, there are two heating lights inside the chamber that can be ensure temperature stable.</p>
<p>3. Equipped with high and low temperature alarm system.</p>
<p>4. Equipped with disinfection functions, the top UV lamp facilitates disinfection</p>
<p>5. Made of 304 stainless steel, easy to clean and disinfected, beautiful corrosion resistant and easy to clean.</p>
<p>6. The air inlet and exhaust are respectively equipped with primary effect, medium effect and HEPA high efficiency three filtration to ensure the cleanliness of the cavity body of the isolator and the external environment. The primary effect filter can be cleaned regularly to block large particles and dust to extend the life of the high efficiency filter.</p>
<p>7. Convenience of observation and operation, with observation windows and operation ports designed for researchers to observe the behavior and health status of the ducks and perform necessary operations such as sampling and feeding.</p>
<p>8. Good ventilation system, which helps maintain fresh air and effectively controls the number of air exchanges to avoid the accumulation of harmful gases.</p>
<p>&nbsp;</p>
<figure id="attachment_11021" aria-describedby="caption-attachment-11021" style="width: 688px" class="wp-caption alignnone"><img decoding="async" class="wp-image-11021 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/BCI-II-1.webp" alt="Duck Isolators" width="688" height="329" srcset="https://keylaser.am/wp-content/uploads/2024/10/BCI-II-1.webp 688w, https://keylaser.am/wp-content/uploads/2024/10/BCI-II-1-300x143.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/BCI-II-1-600x287.webp 600w" sizes="(max-width: 688px) 100vw, 688px" /><figcaption id="caption-attachment-11021" class="wp-caption-text"> </figcaption></figure>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="886" align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td width="0">Model</td>
<td width="580">BCI-II</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="0">External Size(W*D*H)</td>
<td width="580">2594*812*1820mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="0">Animal Activity Area(W*D*H)</td>
<td width="580">1994*712*800mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="0">Air Exchange Rate</td>
<td width="580">≥20 times/h</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="0">Airflow Velocity</td>
<td width="580">0.1m/s~0.2m/s within the duck living space</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="0">Falling Bacteria(numbers/utensil/hour)</td>
<td width="580">0</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="0">Filter</td>
<td width="580">Pre-filter, Mid-filter, HEPA(H14) filter</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="0">Noise</td>
<td width="580">≤70dB(A)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="0">Standard Accessories</td>
<td width="580">heating lamp, lighting lamp, UV lamp, feeding and drinking system, gloves*10(pairs), temperature and humidity sensors, pressure differential sensors</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="0">Power Supply</td>
<td width="580">AC220±10%, 50Hz/60Hz(Standard); 110V, 50/60Hz(Optional, external transformer)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="263">Consumption</td>
<td width="580">700W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="0">Package Size(W*D*H)</td>
<td width="580">2845*992*2050mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="0">Net Weight</td>
<td width="580">303kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="0">Gross Weight</td>
<td width="580">423kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/duck-isolators/">Duck Isolators</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Laminar Flow Pathology Workstation</title>
		<link>https://keylaser.am/product/laminar-flow-pathology-workstation/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 09 Oct 2024 15:03:37 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11011</guid>

					<description><![CDATA[<p><strong>Introduction:</strong><br />
Pathological sampling bench is widely used in hospital pathology department,pathology laboratory, etc.<br />
Reasonable ventilation system protects operator away from the harmful gas produced by the formalin during sampling.The hot &#38; cold water system ensures it can adapt work in different climates.</p>
<p>The post <a href="https://keylaser.am/product/laminar-flow-pathology-workstation/">Laminar Flow Pathology Workstation</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>QCT-1800L</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p>&nbsp;</p>
<p><strong>Features:</strong></p>
<p>1. The open table design is adopted, and the front and rear of the operation area are unobstructed to ensure the maximum experimental space</p>
<p>2. Airflow pattern design with top air supply and bottom exhaust</p>
<p>3. Intelligent control system adopts LCD operation panel</p>
<p>4. The whole machine is made of 304 stainless steel, easy to clean</p>
<p>5. Standard formaldehyde filling device, built-in liquid tank, with liquid filling accessories and low liquid level alarm system, convenient for filling formaldehyde</p>
<p>&nbsp;</p>
</div>
</div>
</div>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-11012 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/QCT-1800L.webp" alt="Laminar Flow Pathology Workstation" width="952" height="296" srcset="https://keylaser.am/wp-content/uploads/2024/10/QCT-1800L.webp 952w, https://keylaser.am/wp-content/uploads/2024/10/QCT-1800L-300x93.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/QCT-1800L-768x239.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/QCT-1800L-600x187.webp 600w" sizes="auto, (max-width: 952px) 100vw, 952px" /></p>
<p>&nbsp;</p>
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>QCT-1800L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size</td>
<td>1800*800*2000mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Operating Table Size</td>
<td>1455*490mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Operating Table Adjustable Height</td>
<td>800~950mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Airflow Pattern</td>
<td>Top air supply and bottom exhaust</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Standard Function</td>
<td>Formaldehyde perfusion system, table lifting system, human body induction switch, touch control screen, spotlight, UV lamp, LED lighting, telescopic faucet, folding hot and cold faucet, electric air valve, sink, transparent socket</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Optional Function</td>
<td>Water heater, pulverizer, eye washer, magnetic adsorption tool, LED floor magnifying glass, sampling plate, stainless steel paper box, camera, large object imaging system, mobile display stand, plasma purification system, hand dryer, external exhaust fan exhaust air fan</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power Supply</td>
<td>Standard: 220V, 50/60Hz; Optional: 110V, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>380kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Packing Size</td>
<td>1980*960*2250mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>410kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/laminar-flow-pathology-workstation/">Laminar Flow Pathology Workstation</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Animal Cage Changing Station</title>
		<link>https://keylaser.am/product/animal-cage-changing-station/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 09 Oct 2024 15:00:18 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11005</guid>

					<description><![CDATA[<p><strong>Introduction：</strong><br />
The animal cage changing station is suitable for the replacement of animal cages in SPF animal rooms, the anatomy of experimental animals and the separation of tissues, etc. It adopts positive vertical flow, double primary effect and double high efficiency filtration design, which can prevent animals in the work area from being polluted by outside air. Protect the operator from allergens and special odors generated during the experiment. In addition, the double-sided open design facilitates simultaneous operation by multiple person. It is a safety protection device specially designed for animal research laboratories.</p>
<p>The post <a href="https://keylaser.am/product/animal-cage-changing-station/">Animal Cage Changing Station</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>DAW-1100</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1. Two-way safety protection: with excellent ventilation system and negative pressure airflow, it can provide two-way safety protection for people, animals, environment, and objects during the process of animal cage change.</p>
<p>2. Use high-quality materials: the work surface is made of 304 stainless steel, which can be quickly disassembled and cleaned up waste.</p>
<p>3. Double-layer filtration system: primary and high-efficiency double-layer filtration system.</p>
<p>4. Control system: LCD touch screen design, real-time dynamic display of the airflow speed of the workstation.</p>
<p>5.Audio and visual alarm: Abnormal air flow velocity and filter replacement.</p>
</div>
<p>&nbsp;</p>
</div>
</div>
<figure id="attachment_11006" aria-describedby="caption-attachment-11006" style="width: 501px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-11006 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/DAW-1.webp" alt="Animal Cage Changing Station" width="501" height="703" srcset="https://keylaser.am/wp-content/uploads/2024/10/DAW-1.webp 501w, https://keylaser.am/wp-content/uploads/2024/10/DAW-1-214x300.webp 214w" sizes="auto, (max-width: 501px) 100vw, 501px" /><figcaption id="caption-attachment-11006" class="wp-caption-text"> </figcaption></figure>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-11007 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/DAW-2.webp" alt="Animal Cage Changing Station" width="1039" height="806" srcset="https://keylaser.am/wp-content/uploads/2024/10/DAW-2.webp 1039w, https://keylaser.am/wp-content/uploads/2024/10/DAW-2-300x233.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/DAW-2-1024x794.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/DAW-2-768x596.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/DAW-2-600x465.webp 600w" sizes="auto, (max-width: 1039px) 100vw, 1039px" /></p>
<p>&nbsp;</p>
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p>&nbsp;</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="100%" align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td width="395">Model</td>
<td width="487">DAW-1100</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="395">Power Supply</td>
<td width="487">AC220V±10%, 50/60Hz(Standard)</p>
<p>AC110V, 60Hz(Optional)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="395">Instrument Size(L*D*H)</td>
<td width="487">1580*750*1980mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="395">Operating Area Size(L*D*H)</td>
<td width="487">1015*750*585mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="395">Laminar Airflow Velocity</td>
<td width="487">≥0.35m/s</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="395">Noise</td>
<td width="487">≤65dB(A)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="395">Illuminance</td>
<td width="487">≥1000lx</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="395">LED Lamp</td>
<td width="487">12W*2</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="395">Consumption(W)</td>
<td width="487">800W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="395">Air Supply ULPA Filter Size</td>
<td width="487">925*470*69mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="395">Exhaust ULPA Filter Size</td>
<td width="487">910*480*69mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="395">Primary Filter Size</td>
<td width="487">890*505*25mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="395">Filtration Efficiency</td>
<td width="487">99.9995％(φ0.12μm)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="395">Number of Users</td>
<td width="487">1~2</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="395">Package Size(L*D*H)</td>
<td width="487">1460*890*2270mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="395">Gross Weight</td>
<td width="487">243kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/animal-cage-changing-station/">Animal Cage Changing Station</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Gas Cylinder Cabinet</title>
		<link>https://keylaser.am/product/gas-cylinder-cabinet/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 09 Oct 2024 14:56:30 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=10999</guid>

					<description><![CDATA[<p>Introduction:<br />
The gas cylinder cabinet is a metal container used to improve local exhaust ventilation, protect steel cylinders (gas cylinders) from fire outside the cabinet and protect surrounding objects from internal fire.</p>
<p>The post <a href="https://keylaser.am/product/gas-cylinder-cabinet/">Gas Cylinder Cabinet</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BKSC-1Q BKSC-2Q BKSC-3Q</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>* Cabinet body: It adopts high-quality cold-rolled steel plate, which is treated with pickling and phosphating, and the surface is electrostatically sprayed to achieve the effect of anti-acid and alkali and anti-rust.</p>
<p>* Door panel: It adopts detachable hinges, and the window is tempered glass.</p>
<p>* Ventilation holes: There are 4 ventilation holes on each side to facilitate gas circulation.</p>
<p>* Fixed chain: Internal fixed chain is used to prevent the cylinder from tipping over.</p>
<p>* Pedal: There are adjustable pedals at the bottom of the cabinet to facilitate the loading and unloading of gas cylinders.</p>
<p><strong>Technical Parameter:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="866">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td width="238">Model</td>
<td width="205">BKSC-1Q</td>
<td width="205">BKSC-2Q</td>
<td width="217">BKSC-3Q</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="238">Capacity</td>
<td width="205">40L(1 bottle)</td>
<td width="205">80L(2 bottles)</td>
<td width="217">120L(3 bottles)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="238">Door Type</td>
<td width="205">Single door</td>
<td colspan="2">Double door</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="205">External Size(W*D*H)</td>
<td width="205">600*450*1900mm</td>
<td width="217">900*450*1900mm</td>
<td width="238">1200*450*1900mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="205">Package Size(W*D*H)</td>
<td width="205">674*524*2030mm</td>
<td width="217">974*524*2030mm</td>
<td width="238">1274*524*2030mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="205">Net Weight</td>
<td width="205">61kg</td>
<td width="217">85kg</td>
<td width="238">102kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="205">Gross Weight</td>
<td width="205">78kg</td>
<td width="217">105kg</td>
<td width="undefined">124kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p><strong>Optional Alarm Apparatus：</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index1">
<div class="inner">
<table width="866" align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td width="121">NO.</td>
<td width="221">NO.1</td>
<td width="523">NO.2</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="121">Power Supply</td>
<td width="221">220V 50Hz</td>
<td width="523">110~220V 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="121">Alarm Type</td>
<td colspan="2">Audible and visible alarm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="221">Identifiable Gas</td>
<td width="523">methane, acetylene, hydrogen,</p>
<p>coal gas</td>
<td width="undefined">methane, butane, ethanol, hydrogen, liquefied gas, acetylene, ammonia, etc.</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/gas-cylinder-cabinet/">Gas Cylinder Cabinet</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
