	<title>Chemistry Analyzer Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-category/biobase/clinicalanalytical-instrument/chemistry-analyzer/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-category/biobase/clinicalanalytical-instrument/chemistry-analyzer/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Thu, 10 Oct 2024 08:08:17 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>Chemistry Analyzer Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-category/biobase/clinicalanalytical-instrument/chemistry-analyzer/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Semi-auto Chemistry Analyzer BIOBASE-Claire</title>
		<link>https://keylaser.am/product/semi-auto-chemistry-analyzer-biobase-claire/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 08:08:16 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11140</guid>

					<description><![CDATA[<div><strong>Introduction:</strong></div>
<p>Semi-Auto Chemistry Analyzer consists of a microprocessor circuit control system, optical colorimetric system, LCD display, and an operating keyboard. It is widely used in the routine biochemical testing of human serum in medical units.</p>
<p>The post <a href="https://keylaser.am/product/semi-auto-chemistry-analyzer-biobase-claire/">Semi-auto Chemistry Analyzer BIOBASE-Claire</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BIOBASE-Claire</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1. Easy operation by one button.</p>
<p>2. End point, kinetic, fixed time, rate, etc.</p>
<p>3. Large memory to store 144 test programs and 5600 testing results.</p>
<p>4. Excellent Q.C function, Q.C chart can be stored, displayed and printed.</p>
<p>5. Real time graph can be displayed and printed.</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="100%">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td width="219">Model</td>
<td width="662">BIOBASE-Claire</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="219">Reading Cuvette</td>
<td width="662">Quartz cuvette</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3" width="219">Photometric System</td>
<td width="662">Light source: 6V, 10W long life halogen lamp</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="662">Filters: 340/405/450/510/546/578/630nm, 2 more open filter positions</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="662">Wavelength accuracy: ±2nm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4" width="219">Measuring System</td>
<td width="662">Measuring range: 0~3.500O.D.</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="662">Photometric linearity: ±2% from 0 to 2.500O.D.</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="662">Photometric accuracy: ±2% from 0 to 2.500O.D.</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="662">Drift&lt;0.005O.D.</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="219">Display</td>
<td width="662">Touch screen</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="219">Printer</td>
<td width="662">Built-in thermal printer</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="219">Interface</td>
<td width="662">RS-232, USB</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="219">Power Supply</td>
<td width="662">AC110/220V±10%, 60/50Hz</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="219">External Size(W*D*H)</td>
<td width="662">400*380*190mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="219">Package Size(W*D*H)</td>
<td width="662">500*530*350mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="219">Gross Weight</td>
<td width="662">11kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/semi-auto-chemistry-analyzer-biobase-claire/">Semi-auto Chemistry Analyzer BIOBASE-Claire</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Semi-auto Chemistry Analyzer BIOBASE-Silver</title>
		<link>https://keylaser.am/product/semi-auto-chemistry-analyzer-biobase-silver/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 08:05:12 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11133</guid>

					<description><![CDATA[<div><strong>Introduction:</strong></div>
<p>BIOBASE SILVER semi-automatic biochemistry analyzer is a microcomputer-based in-vitro diagnostics instrument uniting optics, mechanics, and automation control in one. It is used together with the related reagents for the quantitative determination of biochemical items, widely applied to various hospitals and research institutes， with the characteristics of high precision, excellent repeatability, and complete function.</p>
<p>The post <a href="https://keylaser.am/product/semi-auto-chemistry-analyzer-biobase-silver/">Semi-auto Chemistry Analyzer BIOBASE-Silver</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BIOBASE-Sliver</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
<div class="ast-oembed-container " style="height: 100%;"><iframe title="BIOBASE Semi-auto Chemistry Analyzer BIOBASE Silver" width="1778" height="1000" src="https://www.youtube.com/embed/Slssp5FqFaQ?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
<p>&nbsp;</p>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1. Easy operation by one button.</p>
<p>2. End point, kinetic, fixed time, rate, etc.</p>
<p>3. Filter wavelength: 340/405/450/510/546/578/630nm, 2 more open filter positions, others on request.</p>
<p>4. With 20 incubating positions.</p>
<p>5. Large Memory to store 144 test programs and 5600 testing results.</p>
<p>6. Excellent Q.C function, Q.C chart can be stored, displayed and printed.</p>
<p>7. 37℃ temperature in flow cell and incubating.</p>
<p>8. Real time graph can be displayed and printed.</p>
<p><strong>Technical Parameters:</strong></p>
<div class="nei-table">
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table border="1" width="756" align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td valign="center" width="172">Model</td>
<td valign="center" width="836">BIOBASE-Silver</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="172">Reading Cuvette</td>
<td valign="center" width="836">Quartz cuvette, Both through cell and direct reading cuvette</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="172">Incubating Positions</td>
<td valign="center" width="836">20 incubating positions</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="3" valign="center" width="172">Photometric System</td>
<td valign="center" width="605">Light source: 6V, 10W long life halogen lamp</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="535">Filters: 340/405/450/510/546/578/630nm, 2 more open filter positions</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="535">Wavelength accuracy: ±2nm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4" valign="center" width="172">Measuring System</td>
<td valign="center" width="836">Measuring range: 0~3.500O.D.</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="535">Photometric linearity: ±2% from 0 to 2.500O.D.</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="535">Photometric accuracy: ±2% from 0 to 2.500O.D.</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="535">Drift&lt;0.005O.D.</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="172">Incubator Temperature</td>
<td valign="center" width="836">R.T. 25℃, 30℃, 37℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="172">Control</td>
<td valign="center" width="836">Precision: ±0.1℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="172">Display</td>
<td valign="center" width="836">Touch screen</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="172">Printer</td>
<td valign="center" width="836">Built-in thermal printer</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="172">Interface</td>
<td valign="center" width="836">RS-232, USB</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="172">Power Supply</td>
<td valign="center" width="836">AC110/220V±10%, 60/50Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="172">External Size(W*D*H)</td>
<td valign="center" width="836">400*380*200mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="172">Packing Size(W*D*H)</td>
<td valign="center" width="836">500*530*350mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="172">Gross Weight</td>
<td valign="center" width="836">12kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/semi-auto-chemistry-analyzer-biobase-silver/">Semi-auto Chemistry Analyzer BIOBASE-Silver</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Automatic Chemistry Analyzer</title>
		<link>https://keylaser.am/product/automatic-chemistry-analyzer/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 08:02:19 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11124</guid>

					<description><![CDATA[<p><strong>Introduction:</strong><br />
Automatic Chemistry Analyzer, a state-of-the-art solution for modern laboratories. With a capacity of 300 sample positions and 432 reaction cuvettes, this analyzer offers unparalleled efficiency and precision.</p>
<p>The post <a href="https://keylaser.am/product/automatic-chemistry-analyzer/">Automatic Chemistry Analyzer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BK-2000</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1. 300 sample positions.</p>
<p>2. 432 reaction cuvettes.</p>
<p>3. 250 refrigerated reagent positions.</p>
<p>4. Double focus, double aperture, holographic concave grating.</p>
<p>5. 2000 tests per hour, ISE is optional.</p>
<p>6. Built-in sample barcode system.</p>
<p>7. Probe with anti-collision function, liquid level detection function.</p>
<p><strong>Technical Parameters：</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="882">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="2">BK-2000</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="3">Overall<br />
Performance</td>
<td>Throughput</td>
<td>2000 tests/hour, ISE(Optional)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Analysis Method</td>
<td>End-point, Fixed-time, Rate(Kinetic), Turbidimetry</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Certificates</td>
<td>CE, FDA, ISO9001, ISO14001, ISO13485</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="7">Sample&amp;Reagent System</td>
<td>Sample Positions</td>
<td>300 sample positions</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Positions</td>
<td>250 reagent positions</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Volume</td>
<td>1~35μl</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Volume</td>
<td>1~350μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Probe</td>
<td>Teflon coating, with anti-collision function, liquid level detection function</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Probe Washing</td>
<td>Automatic washing interior and exterior</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Reagent Cooling</td>
<td>Refrigerated tray with independent switch</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="5">Reaction System</td>
<td>Temperature Control</td>
<td>Water bath 37±0.1℃, real-time monitoring</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Cuvettes</td>
<td>432 reusable cuvettes, optical length 5.5mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Mixer Probe</td>
<td>Independent stirring</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Washing</td>
<td>Automatic cuvettes washing</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>STAT function</td>
<td>YES</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Optical System</td>
<td>Light Source</td>
<td>12V/50W halogen lamp/holographic concave grating</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Spectrophotometry</td>
<td>Post-spectral spectrophotometry</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Wavelength</td>
<td>16 wavelength from 340~850nm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Absorbance</td>
<td>0~3.5Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="2">Calibration&amp;QC</td>
<td>Calibration</td>
<td>Linear: K factor, 1-point, 2-point and multipoint linear</p>
<p>Non-Linear: Spline, Polygon, Index, Ogarithm, Logit-4P, Logit-5P</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Quality Control</td>
<td>Real-time QC, Westgard Multi Rule, Cumulative Sum Check, Twin Plot(2D)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Data Management</td>
<td>Software</td>
<td>Windows 7/8/10, 32 or 64 bit</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>LIS System</td>
<td>Bi-direction, support HL7 protocol</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Interface</td>
<td>LAN port access</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Printer</td>
<td>External, multiple reporting mode available</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Working Conditions</td>
<td>Power Supply</td>
<td>AC220V±10%, 50/60Hz(Standard)</p>
<p>110V±10%, 60Hz(Optional), 3000W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature</td>
<td>15~30℃(±2 ℃)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Water Consumption</td>
<td>Deionized water: 80L/H</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Humidity</td>
<td>40~85%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Size&amp;Weight</td>
<td>External Size (W*D*H)</td>
<td>Scheduling module: 972*1225*1495mm</p>
<p>Analysis module: 1505*1225*1245mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Net Weight</td>
<td>Scheduling module: 160kg</p>
<p>Analysis module: 500kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Package Size (W*D*H)</td>
<td>Scheduling module: 1410*1350*1170mm</p>
<p>Analysis module: 1685*1410*1460mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Gross Weight</td>
<td>Scheduling module: 235kg</p>
<p>Analysis module: 600kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/automatic-chemistry-analyzer/">Automatic Chemistry Analyzer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Auto Chemistry Analyzer BK-1200</title>
		<link>https://keylaser.am/product/auto-chemistry-analyzer-bk-1200/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 07:59:12 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11114</guid>

					<description><![CDATA[<div><strong>Introduction:</strong></div>
<p>It is used to quantitatively analyze the clinical chemistry of human serum, plasma, urine, cerebrospinal fluid and other samples. Do not use for other purposes.</p>
<p>The post <a href="https://keylaser.am/product/auto-chemistry-analyzer-bk-1200/">Auto Chemistry Analyzer BK-1200</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BK-1200</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1. 150 sample positions.</p>
<p>2. 160 reaction cuvettes.</p>
<p>3. 180 refrigerated reagent positions.</p>
<p>4. Optical filter/fiber bragg grating selectable.</p>
<p>5. 800 tests per hour(1200 tests with ISE module).</p>
<p>6. Built-in sample barcode system optional.</p>
<p>7. Probe with anti-collision function, liquid level detection function.</p>
<p>&nbsp;</p>
</div>
<p><img fetchpriority="high" decoding="async" class="wp-image-11120 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/BK-6.webp" alt="Auto Chemistry Analyzer BK-1200" width="900" height="515" srcset="https://keylaser.am/wp-content/uploads/2024/10/BK-6.webp 900w, https://keylaser.am/wp-content/uploads/2024/10/BK-6-300x172.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/BK-6-768x439.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/BK-6-600x343.webp 600w" sizes="(max-width: 900px) 100vw, 900px" /></p>
<div class="prodDetail-editor-container">
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="2">BK-1200</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="1" rowspan="3" width="NaN">Overall</p>
<p>Performance</td>
<td>Throughput</td>
<td>800 tests/hour, 1200 tests/hour with ISE(Optional)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Analysis Method</td>
<td>End-point, Fixed-time, Rate(Kinetic), Turbidimetry</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Certificates</td>
<td>CE, FDA, ISO9001, ISO13485</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="7">Sample&amp;Reagent System</td>
<td>Sample Positions</td>
<td>150 sample positions</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Positions</td>
<td>180 reagent positions</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Volume</td>
<td>1~70μl</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Volume</td>
<td>10~350μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Probe</td>
<td>Teflon coating, with anti-collision function, Liquid level detection function</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Probe Washing</td>
<td>Automatic washing interior and exterior</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Reagent Cooling</td>
<td>Refrigerated tray with independent switch</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="5">Reaction System</td>
<td>Temperature Control</td>
<td>Water bath 37±0.1℃, real-time monitoring</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Cuvettes</td>
<td>160 reusable cuvettes, optical length 6mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Mixer Probe</td>
<td>Independent stirring</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Washing</td>
<td>Automatic cuvettes washing</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>STAT Function</td>
<td>YES</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Optical System</td>
<td>Light Source</td>
<td>12V/20W halogen lamp/fiber bragg grating optional</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Spectrophotometry</td>
<td>Post-spectral spectrophotometry</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Wavelength</td>
<td>12 wavelength from 340~800nm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Absorbance</td>
<td>0~3.5Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="2">Calibration&amp;QC</td>
<td>Calibration</td>
<td>Linear: K factor, 1-point, 2-point and multipoint linear</p>
<p>Non-Linear: Spline, Polygon, Logit-4P, Logit-5P</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Quality Control</td>
<td>Real-time QC, Westgard Multi Rule, Cumulative Sum Check, Twin Plot(2D), Daily QC, Monthly QC</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Data Management</td>
<td>Software</td>
<td>Windows 7/8/10, 32 or 64 bit</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>LIS System</td>
<td>Bi-direction, support HL7 protocol</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Interface</td>
<td>LAN port access</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Printer</td>
<td>External optional, multiple reporting mode available</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Working Conditions</td>
<td>Power Supply</td>
<td>AC220V±10%, 50/60Hz; 110V±10%, 60Hz, 1500W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature</td>
<td>15~30℃(±2℃)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Water Consumption</td>
<td>Deionized water: &lt;25L/H</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Humidity</td>
<td>40%~85%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Size&amp;Weight</td>
<td>External Size (W*D*H)</td>
<td>1360*795*1155mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Net Weight</td>
<td>290kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Package Size (W*D*H)</td>
<td>1729*969*1435mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Gross Weight</td>
<td>400kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/auto-chemistry-analyzer-bk-1200/">Auto Chemistry Analyzer BK-1200</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Auto Chemistry Analyzer BK-600</title>
		<link>https://keylaser.am/product/auto-chemistry-analyzer-bk-600/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 07:55:53 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11104</guid>

					<description><![CDATA[<div><strong>Introduction:</strong></div>
<p>It is used to quantitatively analyze the clinical chemistry of human serum, plasma, urine, cerebrospinal fluid and other samples. Do not use for other purposes.</p>
<p>The post <a href="https://keylaser.am/product/auto-chemistry-analyzer-bk-600/">Auto Chemistry Analyzer BK-600</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BK-600</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:<br />
</strong></p>
<p>1. 600 tests per hour.</p>
<p>2. 120 reaction cuvettes.</p>
<p>3. 180 refrigerated reagent positions.</p>
<p>4. Built-insample barcode system optional.</p>
<p>5. 90 sample positions(120 sample positions optional).</p>
<p>6. Probe with anti-collision function, liquid level detection function.</p>
<p>&nbsp;</p>
</div>
<figure id="attachment_11110" aria-describedby="caption-attachment-11110" style="width: 897px" class="wp-caption alignnone"><img decoding="async" class="wp-image-11110 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/BK-5.webp" alt="Auto Chemistry Analyzer BK-600" width="897" height="508" srcset="https://keylaser.am/wp-content/uploads/2024/10/BK-5.webp 897w, https://keylaser.am/wp-content/uploads/2024/10/BK-5-300x170.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/BK-5-768x435.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/BK-5-600x340.webp 600w" sizes="(max-width: 897px) 100vw, 897px" /><figcaption id="caption-attachment-11110" class="wp-caption-text"> </figcaption></figure>
<div class="prodDetail-editor-container">
<p>&nbsp;</p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="884" align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="2">BK-600</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="3">Overall</p>
<p>Performance</td>
<td>Throughput</td>
<td>600 tests/hour</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Analysis Method</td>
<td>End-point, Fixed-time, Rate(Kinetic), Turbidimetry</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Certification</td>
<td>CE, FDA, ISO9001, ISO13485</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="7">Sample&amp;Reagent System</td>
<td>Sample Positions</td>
<td>90 sample positions, built-in barcode system available</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Positions</td>
<td>180 refrigerated reagent positions(R1: 90 &amp; R2: 90)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Volume</td>
<td>1~70μl</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Volume</td>
<td>10~350μl</td>
</tr>
<tr>
<td colspan="1" rowspan="1">Probe</td>
<td colspan="1" rowspan="1">Teflon coating, with anti-collision function, liquid level detection functio</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Probe Washing</td>
<td>Automatic washing interior and exterior</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Cooling</td>
<td>2~8℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="5">Reaction System</td>
<td>Temperature Control</td>
<td>37±0.1℃, real-time monitoring</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Cuvettes</td>
<td>120 reusable cuvettes, optical length 6mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Mixer Probe</td>
<td>Independent stirring</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Washing</td>
<td>Automatic cuvettes washing</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>STAT Function</td>
<td>YES</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4">Optical System</td>
<td>Light Source</td>
<td>12V/20W halogen lamp</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Spectrophotometry</td>
<td>Post-spectral spectrophotometry</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Wavelength</td>
<td>340, 405, 450, 480, 505, 546, 570, 600, 630, 700, 750, 800nm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Absorbance</td>
<td>0~3.5Abs</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="2">Calibration&amp;QC</td>
<td>Calibration</td>
<td>1-point, 2-point and multipoint, factor, Spline, Logit-4P, Logit-5P, Polygon</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Quality Control</td>
<td>Inserting quality control at random</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4">Data Management</td>
<td>Software</td>
<td>Windows 7/8/10</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>LIS System</td>
<td>Available</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Interface</td>
<td>TCP/IP network interface</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Printer</td>
<td>External optional, multiple reporting mode available</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4">Working Conditions</td>
<td>Power Supply</td>
<td>AC220V±10%, 50/60Hz</p>
<p>110V±10%, 60Hz, 800VA</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temperature</td>
<td>15~30℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Water Consumption</td>
<td>Deionized water: 20L/H</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Humidity</td>
<td>40%~85%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="6">Size&amp;Weight</td>
<td>External Size (W*D*H)</td>
<td>1170*775*1145mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>216kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size (W*D*H)</td>
<td>1358*938*1387mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>281kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Accessory Package Size</td>
<td>550*430*860mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Accessory Gross Weight</td>
<td>20kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/auto-chemistry-analyzer-bk-600/">Auto Chemistry Analyzer BK-600</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>400T/H Automatic Chemistry Analyzer</title>
		<link>https://keylaser.am/product/400t-h-automatic-chemistry-analyzer/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 07:52:03 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11100</guid>

					<description><![CDATA[<div><strong>Introduction:</strong></div>
<p>The 400T/H Automatic Chemistry Analyzer is a state-of-the-art diagnostic tool designed for high-efficiency biochemical analysis. This advanced instrument boasts an impressive array of features tailored to meet the demands of modern laboratories.</p>
<p>The post <a href="https://keylaser.am/product/400t-h-automatic-chemistry-analyzer/">400T/H Automatic Chemistry Analyzer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BK-410</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1. 49 sample positions<br />
2. 56 reagent positions.</p>
<p>3. 120 reaction cuvettes.</p>
<p>4. 400 tests per hour.</p>
<p>5. Probe with anti-collision function, liquid level dectection function.</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="2">BK-410</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4">Overall<br />
Performance</td>
<td>Throughput</td>
<td>400 tests/hour, ISE(Optional)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Analysis Method</td>
<td>End-point, Fixed-time, Rate(Kinetic), Turbidimetry</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Certificates</td>
<td>CE, FDA, ISO9001, ISO14001, ISO13485</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>System</td>
<td>Optional open or close system, continuous working for 24 hours</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="7">Sample &amp; Reagent System</td>
<td>Sample Positions</td>
<td>49 sample positions</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Reagent Position</td>
<td>56 reagent positions</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Sample Volume</td>
<td>2~70μL</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Reagent Volume</td>
<td>20~350μL</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Probe</td>
<td>With anti-collision function, liquid level detection function</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Probe Washing</td>
<td>Automatic washing interior and exterior</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Cooling</td>
<td>2~12℃ for 24 hours</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Reaction System</td>
<td>Temperature Control</td>
<td>Water bath37±0.2℃, real-time monitoring</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Cuvettes</td>
<td>120 reusable cuvettes</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Mixer Probe</td>
<td>Independent stirring, automatic frequency conversion</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Washing</td>
<td>Automatic cuvettes washing</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Optical System</td>
<td>Light Source</td>
<td>Halogen lamp, water-cooling</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Spectrophotometry</td>
<td>Post-spectral spectrophotometry</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Wavelength</td>
<td>340~800nm, ＜±1nm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Absorbance</td>
<td>0~3.0Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="2">Calibration &amp; QC</td>
<td>Calibration</td>
<td>Linear: K factor, 1-point, 2-point and multipoint linear</p>
<p>Non-Linear: Spline, Polygon, Index, Ogarithm, Logit-4P, Logit-5P</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Quality Control</td>
<td>Real-time QC, Westgard multi rule, Cumulative Sum Check, Twin Plot(2D)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Data Management</td>
<td>Software</td>
<td>Windows 7/8/10, 32 or 64 bit</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>LIS System</td>
<td>Bi-direction, support HL7 protocol</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Interface</td>
<td>LAN port access</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Printer</td>
<td>External, multiple reporting mode available</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Working Conditions</td>
<td>Power Supply</td>
<td>AC220V±10%, 50/60Hz(Standard); 110V±10% 60Hz(Optional), 650VA</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature</td>
<td>15~30℃（±2℃）</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Water Consumption</td>
<td>Deionized water＜10L/h</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Humidity</td>
<td>40~85%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Size &amp; Weight</td>
<td>External Size (W*D*H)</td>
<td>973*645*520mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Net Weight</td>
<td>96kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Package Size (W*D*H)</td>
<td>1130*735*1040mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Gross Weight</td>
<td>141kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/400t-h-automatic-chemistry-analyzer/">400T/H Automatic Chemistry Analyzer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Auto Chemistry Analyzer BK-400</title>
		<link>https://keylaser.am/product/auto-chemistry-analyzer-bk-400/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 07:49:37 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11091</guid>

					<description><![CDATA[<div><strong>Introduction:</strong></div>
<p>It is used to quantitatively analyze the clinical chemistry of human serum, plasma, urine, cerebrospinal fluid and other samples. Do not use for other purposes.</p>
<p>The post <a href="https://keylaser.am/product/auto-chemistry-analyzer-bk-400/">Auto Chemistry Analyzer BK-400</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BK-400</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p>&nbsp;</p>
<p><strong>Features:</strong></p>
<p>1. 400 tests per hour.</p>
<p>2. 90 reagent positions.</p>
<p>3. 120 reaction cuvettes.</p>
<p>4. Built-in sample barcode system optional.</p>
<p>5. 60 sample positions(90 sample positions optional).</p>
<p>6. Probe with anti-collision function, liquid level detection function.</p>
<p>&nbsp;</p>
</div>
</div>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-11096 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/BK-4.webp" alt="Auto Chemistry Analyzer BK-400" width="1047" height="583" srcset="https://keylaser.am/wp-content/uploads/2024/10/BK-4.webp 1047w, https://keylaser.am/wp-content/uploads/2024/10/BK-4-300x167.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/BK-4-1024x570.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/BK-4-768x428.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/BK-4-600x334.webp 600w" sizes="auto, (max-width: 1047px) 100vw, 1047px" /></p>
<p>&nbsp;</p>
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Technical Parameters：</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="884" align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="2" width="0">BK-400</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="3" width="162">Overall</p>
<p>Performance</td>
<td width="161">Throughput</td>
<td>400 tests/hour</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="0">Analysis Method</td>
<td width="497">End-point, Fixed-time, Rate(Kinetic), Turbidimetry</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="0">Certification</td>
<td width="497">CE, FDA, ISO9001, ISO13485</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="7" width="0">Sample&amp;Reagent System</td>
<td width="161">Sample Positions</td>
<td>60 or 90 sample positions, built-in barcode system available</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="0">Reagent Positions</td>
<td width="497">90 refrigerated reagent positions</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="0">Sample Volume</td>
<td width="497">1~70μl</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="0">Reagent Volume</td>
<td width="497">10~350μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="0">Probe</td>
<td width="497">Teflon coating, with anti-collision function, liquid level detection function</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="0">Probe Washing</td>
<td width="497">Automatic washing interior and exterior</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="0">Reagent Cooling</td>
<td width="497">2~8℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="5" width="0">Reaction System</td>
<td width="161">Temperature Control</td>
<td>37±0.1℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="0">Cuvettes</td>
<td width="497">120 reusable cuvettes, optical length 6mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="0">Mixer Probe</td>
<td width="497">Independent stirring</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="0">Washing</td>
<td width="497">Automatic cuvettes washing</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="0">STAT Function</td>
<td width="497">YES</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4" width="0">Optical System</td>
<td width="161">Light Source</td>
<td>12V/20W halogen-tungsten lamp</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="0">Spectrophotometry</td>
<td width="497">Post-spectral spectrophotometry</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="0">Wavelength</td>
<td width="497">340, 405, 450, 480, 505, 546, 570, 600, 630, 700, 750, 800nm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="0">Absorbance</td>
<td width="497">0~3.5Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3" width="0">Calibration&amp;QC</td>
<td rowspan="2" width="161">Calibration</td>
<td colspan="1" rowspan="2">Linear: K factor, 1-point, 2-point and multipoint linear</p>
<p>Non-Linear: Spline, Polygon, Logit-4P, Logit-5P</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="0">Quality Control</td>
<td width="497">Real-time QC, Westgard multi rule, Cumulative Sum Check, Twin Plot(2D), Daily QC, Monthly QC</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4" width="0">Data Management</td>
<td width="161">Software</td>
<td>Windows 7/8/10, 32 or 64 bit</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="0">LIS System</td>
<td width="497">Bi-direction, support HL7 protocol</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="0">Interface</td>
<td width="497">TCP/IP network interface</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="0">Printer</td>
<td width="497">External optional, multiple reporting mode available</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4" width="0">Working Conditions</td>
<td width="161">Power Supply</td>
<td>AC220V±10%, 50/60Hz; 110V±10%, 60Hz, 500W</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="0">Temperature</td>
<td width="497">15~30℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="0">Water Consumption</td>
<td width="497">Deionized water: &lt;12L/h</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="0">Humidity</td>
<td width="497">40%~85%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4" width="0">Size&amp;Weight</td>
<td width="161">External Size (W*D*H)</td>
<td>1170*775*1145mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="0">Net Weight</td>
<td width="497">190kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="0">Package Size (W*D*H)</td>
<td width="497">1358*935*1387mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="0">Gross Weight</td>
<td width="497">255kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/auto-chemistry-analyzer-bk-400/">Auto Chemistry Analyzer BK-400</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>300T/H Automatic Chemistry Analyzer</title>
		<link>https://keylaser.am/product/300t-h-automatic-chemistry-analyzer/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 07:46:18 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11087</guid>

					<description><![CDATA[<div><strong>Introduction:</strong></div>
<p>The 300T/H Automatic Chemistry Analyzer is a state-of-the-art diagnostic tool designed for high-efficiency biochemical analysis. This advanced instrument boasts an impressive array of features tailored to meet the demands of modern laboratories.</p>
<p>The post <a href="https://keylaser.am/product/300t-h-automatic-chemistry-analyzer/">300T/H Automatic Chemistry Analyzer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BK-310</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1.  49 sample positions<br />
2.  56 reagent positions.</p>
<p>3. 120 reaction cuvettes.</p>
<p>4. 300 tests per hour.</p>
<p>5. Probe with anti-collision function, liquid level dectection function.</p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="2">BK-310</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4">Overall<br />
Performance</td>
<td>Throughput</td>
<td>300 tests/hour, ISE(Optional)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Analysis Method</td>
<td>End-point, Fixed-time, Rate(Kinetic), Turbidimetry</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Certificates</td>
<td>CE, FDA, ISO9001, ISO14001, ISO13485</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>System</td>
<td>Optional open or close system, continuous working for 24 hours</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="7">Sample&amp;Reagent System</td>
<td>Sample Positions</td>
<td>49 sample positions</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Reagent Position</td>
<td>56 reagent positions</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Sample Volume</td>
<td>2~70μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Reagent Volume</td>
<td>20~350μl</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Probe</td>
<td>With anti-collision function, liquid level detection function</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Probe Washing</td>
<td>Automatic washing interior and exterior</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Cooling</td>
<td>2~12℃ for 24 hours</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Reaction System</td>
<td>Temperature Control</td>
<td>37±0.2℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Cuvettes</td>
<td>120 reusable cuvettes</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Mixer Probe</td>
<td>Independent stirring, automatic frequency conversion</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Washing</td>
<td>Automatic cuvettes washing</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Optical System</td>
<td>Light Source</td>
<td>Halogen lamp, water-cooling</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Spectrophotometry</td>
<td>Post-spectral spectrophotometry</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Wavelength</td>
<td>340~700nm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Absorbance</td>
<td>0~3.0Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="2">Calibration&amp;QC</td>
<td>Calibration</td>
<td>Linear: K factor, 1-point, 2-point and multipoint linear</p>
<p>Non-Linear: Spline, Polygon, Index, Ogarithm, Logit-4P, Logit-5P</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Quality Control</td>
<td>Real-time QC, Westgard multi rule, Cumulative Sum Check, Twin Plot(2D)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Data Management</td>
<td>Software</td>
<td>Windows 7/8/10, 32 or 64 bit</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>LIS System</td>
<td>Bi-direction, support HL7 protocol</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Interface</td>
<td>LAN port access</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Printer</td>
<td>External, multiple reporting mode available</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Working Conditions</td>
<td>Power Supply</td>
<td>AC220V±10%, 50/60Hz(Standard)</p>
<p>110V±10%, 60Hz(Optional), 350VA</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature</td>
<td>15~30℃(±2℃)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Water Consumption</td>
<td>Deionized water＜5L/h</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Humidity</td>
<td>40~85%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Size&amp;Weight</td>
<td>External Size (W*D*H)</td>
<td>873*585*500mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Net Weight</td>
<td>80kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Package Size (W*D*H)</td>
<td>1130*735*1040mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Gross Weight</td>
<td>125kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/300t-h-automatic-chemistry-analyzer/">300T/H Automatic Chemistry Analyzer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Auto Chemistry Analyzer BK-280</title>
		<link>https://keylaser.am/product/auto-chemistry-analyzer-bk-280/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 07:44:23 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11076</guid>

					<description><![CDATA[<p><strong>Introduction:</strong></p>
<p>It is used to quantitatively analyze the clinical chemistry of human serum, plasma, urine, cerebrospinal fluid and other samples. Do not use for other purposes.</p>
<p>The post <a href="https://keylaser.am/product/auto-chemistry-analyzer-bk-280/">Auto Chemistry Analyzer BK-280</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BK-280</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
<div class="ast-oembed-container " style="height: 100%;"><iframe loading="lazy" title="BIOBASE Automatic Chemistry Analyzer BK-280" width="1778" height="1000" src="https://www.youtube.com/embed/AZ4wUafjJyQ?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
<p>&nbsp;</p>
<p><strong>Festures:</strong></p>
<p>1. 49 sample positions.</p>
<p>2. 56 reagent positions.</p>
<p>3. 120 reaction cuvettes.</p>
<p>4. 200 tests per hour.</p>
<p>5. Probe with anti-collision function, liquid level dectection function.</p>
<p>&nbsp;</p>
<figure id="attachment_11078" aria-describedby="caption-attachment-11078" style="width: 1129px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-11078 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/02-1.webp" alt="Auto Chemistry Analyzer BK-280" width="1129" height="544" srcset="https://keylaser.am/wp-content/uploads/2024/10/02-1.webp 1129w, https://keylaser.am/wp-content/uploads/2024/10/02-1-300x145.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/02-1-1024x493.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/02-1-768x370.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/02-1-600x289.webp 600w" sizes="auto, (max-width: 1129px) 100vw, 1129px" /><figcaption id="caption-attachment-11078" class="wp-caption-text"> </figcaption></figure>
<p>&nbsp;</p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="2">BK-280</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="3">Overall</p>
<p>Performance</td>
<td>Throughput</td>
<td>200 tests/hour</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Analysis Method</td>
<td>End-point, Fixed-time, Rate(Kinetic), Turbidimetry</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Certificates</td>
<td>CE, FDA, ISO9001, ISO13485</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="7">Sample&amp;Reagent Unit</td>
<td>Sample Positions</td>
<td>49 sample positions</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Positions</td>
<td>56 reagent positions</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Volume</td>
<td>2~70μl</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Volume</td>
<td>20~350μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Probe</td>
<td>Teflon coating, with anti-collision function, liquid level detection function</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Probe Washing</td>
<td>Automatic washing interior and exterior</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Reagent Cooling</td>
<td>Refrigerated tray with independent switch</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="5">Reaction System</td>
<td>Temperature Control</td>
<td>37±0.2℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Cuvettes</td>
<td>120 reusable cuvettes, optical length 6mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>MixerProbe</td>
<td>Independent stirring</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Washing</td>
<td>Automatic cuvettes washing</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>STAT function</td>
<td>YES</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Optical System</td>
<td>Light Source</td>
<td>12V/30W halogen lamp</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Spectrophotometry</td>
<td>Post-spectral spectrophotometry</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Wavelength</td>
<td>340, 405, 450, 480, 505, 546, 570, 600, 630, 700, 750, 800nm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Absorbance</td>
<td>0~3.0Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="2">Calibration&amp;QC</td>
<td>Calibration</td>
<td>Linear: K factor, 1-point, 2-point and multipoint linear</p>
<p>Non-Linear: Spline, Polygon, Logit-4P, Logit-5P</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Quality Control</td>
<td>Real-time QC, Westgard multi rule, Cumulative sum check, Twin Plot(2D), Daily QC, Monthly QC</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Data Management</td>
<td>Software</td>
<td>Windows 7/8/10, 32 or 64 bit</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>LIS System</td>
<td>Bi-direction, support HL7 protocol</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Interface</td>
<td>LAN port access</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Printer</td>
<td>External optional, multiple reporting mode available</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Working Conditions</td>
<td>Power Supply</td>
<td>AC220V±10%, 50/60Hz; 110V±10%, 60Hz, 300W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature</td>
<td>15~30℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>WaterConsumption</td>
<td>Deionized water: 5L/H</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Humidity</td>
<td>40%~85%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Size&amp;Weight</td>
<td>External Size (W*D*H)</td>
<td>950*600*515mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Net Weight</td>
<td>75kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Package Size(W*D*H)</td>
<td>1130*735*1040mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Gross Weight</td>
<td>135kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/auto-chemistry-analyzer-bk-280/">Auto Chemistry Analyzer BK-280</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Auto Chemistry Analyzer BK-200</title>
		<link>https://keylaser.am/product/auto-chemistry-analyzer-bk-200/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 07:37:53 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11064</guid>

					<description><![CDATA[<p><strong>Introduction:</strong></p>
<p>It is used to quantitatively analyze the clinical chemistry of human serum, plasma, urine, cerebrospinal fluid and other samples. Do not use for other purposes.</p>
<p>The post <a href="https://keylaser.am/product/auto-chemistry-analyzer-bk-200/">Auto Chemistry Analyzer BK-200</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="proddetails-detial-wrap">
<div class="detial-wrap-cont">
<div class="detial-cont-index">
<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BK-200</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
</div>
<div class="ast-oembed-container " style="height: 100%;"><iframe loading="lazy" title="Auto Chemistry Analyzer BK-200" width="1778" height="1000" src="https://www.youtube.com/embed/-PgGXCkumgo?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
<p>&nbsp;</p>
<div class="detial-cont-index">
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1. 37 sample positions.</p>
<p>2. 28 reagent positions.</p>
<p>3. 48 reaction cuvettes.</p>
<p>4. 200 tests per hour.</p>
<p>5. Probe with anti-collision function, liquid level dectection function.</p>
<p>&nbsp;</p>
<p><img loading="lazy" decoding="async" class="wp-image-11072 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/02.webp" alt="Auto Chemistry Analyzer BK-200" width="529" height="380" srcset="https://keylaser.am/wp-content/uploads/2024/10/02.webp 529w, https://keylaser.am/wp-content/uploads/2024/10/02-300x216.webp 300w" sizes="auto, (max-width: 529px) 100vw, 529px" /><img loading="lazy" decoding="async" class="alignnone wp-image-11065 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/01.webp" alt="Auto Chemistry Analyzer BK-200" width="1010" height="581" srcset="https://keylaser.am/wp-content/uploads/2024/10/01.webp 1010w, https://keylaser.am/wp-content/uploads/2024/10/01-300x173.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/01-768x442.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/01-600x345.webp 600w" sizes="auto, (max-width: 1010px) 100vw, 1010px" /></p>
<p>&nbsp;</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="884">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td colspan="2">Model</td>
<td width="275">BK-200</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="3" width="93">Overall<br />
Performance</td>
<td width="276">Throughput</td>
<td width="633">200 tests/hour</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="248">Analysis Method</td>
<td width="252">End-point, Fixed-time, Rate(Kinetic), <a>Turbidimetry</a></td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="248">Certificates</td>
<td width="252">CE, FDA, ISO9001, ISO13485</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="7" width="93">Sample&amp;Reagent System</td>
<td width="276">Sample Positions</td>
<td width="633">37 sample positions</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="248">Reagent Position</td>
<td width="252">28 reagent positions</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="248">Sample Volume</td>
<td width="252">2~70µl</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="248">Reagent Volume</td>
<td width="252">20~350µl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="248">Probe</td>
<td width="252">Teflon coating, with anti-collision function, liquid level detection function</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="248">Probe Washing</td>
<td width="252">Automatic washing interior and exterior</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="248">Reagent Cooling</td>
<td width="252">Refrigerated tray with independent switch</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="5" width="93">Reaction System</td>
<td width="276">Temperature Control</td>
<td width="633">37±0.2℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="248">Cuvettes</td>
<td width="252">48 reusable cuvettes, optical length 6mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="248">Mixer Probe</td>
<td width="252">Independent stirring</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="248">Washing</td>
<td width="252">Automatic cuvettes washing</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="248">STAT Function</td>
<td width="252">YES</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4" width="93">Optical System</td>
<td width="276">Light Source</td>
<td width="633">6V/10W halogen lamp</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="248">Spectrophotometry</td>
<td width="252">Post-spectral spectrophotometry</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="248">Wavelength</td>
<td width="252">340, 405, 450, 510, 546, 578, 630, 700nm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="248">Absorbance</td>
<td width="252">0~3.0Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="2" width="93">Calibration&amp;QC</td>
<td width="276">Calibration</td>
<td width="633">Linear: K factor, 1-point, 2-point and multipoint linear Non-Linear: Spline, Polygon, Logit-4P, Logit-5P</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="248">Quality Control</td>
<td width="252">Real-time QC, Westgard multi rule, Cumulative Sum Check, Twin Plot(2D), Daily QC, Monthly QC</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="1" rowspan="4" width="171">Data Management</td>
<td width="248">Software</td>
<td width="252">Windows 7/8/10, 32 or 64 bit</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="248">LIS System</td>
<td width="252">Bi-direction, support HL7 protocol</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="248">Interface</td>
<td width="252">LAN port access</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="248">Printer</td>
<td width="252">External optional, multiple reporting mode available</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4" width="93">Working Conditions</td>
<td width="276">Power Supply</td>
<td width="633">AC220V±10%, 50/60Hz; 110V±10%, 60Hz, 300W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="248">Temperature</td>
<td width="252">15~30℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="248">Water Consumption</td>
<td width="252">Deionized water:＜5L/H</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="248">Humidity</td>
<td width="252">40%~85%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4" width="93">Size&amp;Weight</td>
<td width="276">External Size (W*D*H)</td>
<td width="633">625*425*460mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="266">Net Weight</td>
<td width="252">36kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="266">Package Size (W*D*H)</td>
<td width="252">750*560*900mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="266">Gross Weight</td>
<td width="252">55kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="pro-detials-listshow fix"></div>
<p>The post <a href="https://keylaser.am/product/auto-chemistry-analyzer-bk-200/">Auto Chemistry Analyzer BK-200</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>