<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Clinical&amp;Analytical Instrument Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-category/biobase/clinicalanalytical-instrument/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-category/biobase/clinicalanalytical-instrument/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Mon, 23 Mar 2026 08:59:31 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>Clinical&amp;Analytical Instrument Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-category/biobase/clinicalanalytical-instrument/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Flow Cytometer B7H FlowCyte B7</title>
		<link>https://keylaser.am/product/flow-cytometer-b7h-flowcyte-b7/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 23 Mar 2026 08:59:31 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14987</guid>

					<description><![CDATA[<p><label>Model: </label>B7H FlowCyte B7</p>
<p>Flow cytometer is a high-precision analytical and sorting instrument widely used in life sciences, medicine, immunology, and other fields. It integrates fluid mechanics, optics, electronics, and computer technology to rapidly analyze and sort individual cells (or particles) in a liquid suspension. By detecting scattered light signals and fluorescent signals from cells labeled with specific probes, the instrument can quantitatively measure multiple physical and chemical properties of cells (such as size, granularity, surface antigens, and intracellular components) at a speed of thousands to tens of thousands of cells per second, enabling high-throughput, multi-parameter, and non-destructive cellular analysis.</p>
<p>The post <a href="https://keylaser.am/product/flow-cytometer-b7h-flowcyte-b7/">Flow Cytometer B7H FlowCyte B7</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img fetchpriority="high" decoding="async" class="alignnone wp-image-14990 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-18.webp" alt="Flow Cytometer B7H FlowCyte B7" width="1139" height="894" srcset="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-18.webp 1139w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-18-300x235.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-18-1024x804.webp 1024w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-18-768x603.webp 768w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-18-600x471.webp 600w" sizes="(max-width: 1139px) 100vw, 1139px" /></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Item</td>
<td>Recommended Reagent</td>
<td>Application Department</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Lymphocyte Subset T Analysis</td>
<td>CD45</p>
<p>CD4</p>
<p>CD3</p>
<p>CD8</td>
<td rowspan="2">Clinical Laboratory</p>
<p>Infectious Disease Department</p>
<p>Oncology Department</p>
<p>Department of Rheumatology and Immunology</p>
<p>Department of Pediatrics Blood Specialty</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Lymphocyte Subset T/B/NK Analysis</td>
<td>CD45</p>
<p>CD3</p>
<p>CD16</p>
<p>CD56</p>
<p>CD19</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Absolute Count of CD4+T Lymphocyte</td>
<td>CD45</p>
<p>CD4</p>
<p>CD3</p>
<p>CD8</td>
<td>CDC (AIDS)</p>
<p>Infectious Disease Department</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Cytokine Th1/Th2/Th17 Analysis</td>
<td>Th1: IL-2, IFN-γ, TNF-α</p>
<p>Th2: IL-4, IL-6, IL-10</p>
<p>Th17: IL-17</td>
<td>Infectious Disease Department</p>
<p>Oncology Department</p>
<p>Department of Rheumatology and Immunology</p>
<p>Department of Organ Transplantation</p>
<p>Respiratory Department</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>HLA-B27 Detection for AS</td>
<td>HLA-B27-FITC</p>
<p>HLA-B7-PE</p>
<p>IgG2a-FITC</p>
<p>IgG1-PE</td>
<td>Department of Rheumatology and Immunology</p>
<p>Orthopedics</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>DFI Analysis</td>
<td>Acridine orange (AO) Staining Solution</td>
<td>Reproductive Department</p>
<p>Infertility Department</p>
<p>Reproductive Medicine Centre</td>
</tr>
</tbody>
</table>
</div>
</div>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index1">
<div class="inner">
<table width="882">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>FlowCyte B7H</td>
<td>FlowCyte B7</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Laser</td>
<td colspan="2">488nm solid（60mW）</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Detector</td>
<td colspan="2">FSC, SSC, FL1-FL5</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Fluorescence Channel</td>
<td colspan="2">FL1:525/50（FITC）</p>
<p>FL2:585/40（PE）</p>
<p>FL3:630/30（PE-Texas Red/ECD/PI）</p>
<p>FL4:697/60（PerCP/PE-Cy5/PE-Cy5.5）</p>
<p>FL5:780/60（PE-Cy7）</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Fluorescence Sensitivity</td>
<td colspan="2">FITC≤50 MESF, PE≤30MESF</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Fluorescence Linearity</td>
<td colspan="2">≥0.99</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>FSC Sensitivity</td>
<td colspan="2">≤1μm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Test Particle Size</td>
<td colspan="2">0.2~50μm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Carry Over</td>
<td colspan="2">≤0.5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Instrument CV</td>
<td colspan="2">FSC and all FL channel CV less than 2%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>FSC and SSC CV</td>
<td colspan="2">Can separate red blood cells and platelet, can separate white blood cells into 3 groups</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Test Speed</td>
<td colspan="2">≥46000 cells/s</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Minimum Sample Vol</td>
<td colspan="2">90μL</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Measure Range</td>
<td colspan="2">Maximum Support 10⁷</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Threshold</td>
<td colspan="2">Double threshold, minimum cells fraction</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Fluorescence Compensation</td>
<td colspan="2">Support auto online compensation, offline compensation and visualized compensation</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Item Template</td>
<td colspan="2">Support Item template, acquisition conditions/fluorescence compensation one-click use</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Intake Method</td>
<td colspan="2">Manual intake</p>
<p>Rotary wheel auto-sampling with auto-mixing function:32tests/wheel</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Liquid Storage Station</td>
<td colspan="2">Sheath bottle, waste bottle, shutdown liquid bottle 2L,</p>
<p>cleaning liquid bottle 0.5L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Software</td>
<td colspan="2">English/Chinese</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>PC</td>
<td colspan="2">Dell（CPU i5/8G DDR4/1T hard disk）+Dell 27 inches monitor</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power Supply</td>
<td colspan="2">AC220/110V±10%, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Auto-sampler</td>
<td>/</td>
<td>32-postions autosampler(Stanndard)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size(W*D*H)</td>
<td>430*500*330mm</td>
<td>650*500*330mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>30kg</td>
<td>35kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Packing Size(W*D*H)</td>
<td colspan="2">Main Instrument: 860*635*648mm</p>
<p>Accessories: 860*680*810mm</p>
<p>Reagent: 405*270*400mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td colspan="2">Main Instrument: 56kg</p>
<p>Accessories: 54kg</p>
<p>Reagent: 16kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/flow-cytometer-b7h-flowcyte-b7/">Flow Cytometer B7H FlowCyte B7</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Flow Cytometer ZS-AE7S</title>
		<link>https://keylaser.am/product/flow-cytometer-zs-ae7s/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 23 Mar 2026 08:36:02 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14980</guid>

					<description><![CDATA[<p><label>Model: </label>ZS-AE7S</p>
<p>Flow cytometer is a high-precision analytical and sorting instrument widely used in life sciences, medicine, immunology, and other fields. It integrates fluid mechanics, optics, electronics, and computer technology to rapidly analyze and sort individual cells (or particles) in a liquid suspension. By detecting scattered light signals and fluorescent signals from cells labeled with specific probes, the instrument can quantitatively measure multiple physical and chemical properties of cells (such as size, granularity, surface antigens, and intracellular components) at a speed of thousands to tens of thousands of cells per second, enabling high-throughput, multi-parameter, and non-destructive cellular analysis.</p>
<p>The post <a href="https://keylaser.am/product/flow-cytometer-zs-ae7s/">Flow Cytometer ZS-AE7S</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" class="wp-image-14982 size-large" src="https://keylaser.am/wp-content/uploads/2026/03/MT8600-2-1024x772.webp" alt="Flow Cytometer ZS-AE7S" width="1024" height="772" srcset="https://keylaser.am/wp-content/uploads/2026/03/MT8600-2-1024x772.webp 1024w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-2-300x226.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-2-768x579.webp 768w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-2-600x452.webp 600w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-2.webp 1199w" sizes="(max-width: 1024px) 100vw, 1024px" /></p>
<p><strong>Recommended Reagent Information:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Item</td>
<td>Recommended Reagent</td>
<td>Application Department</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Lymphocyte Subset T Analysis</td>
<td>CD45</p>
<p>CD4</p>
<p>CD3</p>
<p>CD8</td>
<td rowspan="2">Clinical Laboratory</p>
<p>Infectious Disease Department</p>
<p>Oncology Department</p>
<p>Department of Rheumatology and Immunology</p>
<p>Department of Pediatrics Blood Specialty</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Lymphocyte Subset T/B/NK Analysis</td>
<td>CD45</p>
<p>CD3</p>
<p>CD16</p>
<p>CD56</p>
<p>CD19</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Absolute Count of CD4+T Lymphocyte</td>
<td>CD45</p>
<p>CD4</p>
<p>CD3</p>
<p>CD8</td>
<td>CDC (AIDS)</p>
<p>Infectious Disease Department</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Cytokine Th1/Th2/Th17 Analysis</td>
<td>Th1: IL-2, IFN-γ, TNF-α</p>
<p>Th2: IL-4, IL-6, IL-10</p>
<p>Th17: IL-17</td>
<td>Infectious Disease Department</p>
<p>Oncology Department</p>
<p>Department of Rheumatology and Immunology</p>
<p>Department of Organ Transplantation</p>
<p>Respiratory Department</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>HLA-B27 Detection for AS</td>
<td>HLA-B27-FITC</p>
<p>HLA-B7-PE</p>
<p>IgG2a-FITC</p>
<p>IgG1-PE</td>
<td>Department of Rheumatology and Immunology</p>
<p>Orthopedics</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>DFI Analysis</td>
<td>Acridine orange (AO) Staining Solution</td>
<td>Reproductive Department</p>
<p>Infertility Department</p>
<p>Reproductive Medicine Centre</td>
</tr>
</tbody>
</table>
</div>
</div>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index1">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>ZS-AE7S</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Laser</td>
<td>488nm solid（60mW）</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Detector</td>
<td>FSC, SSC, FL1-FL5</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Fluorescence Channel</td>
<td>FL1:525/50（FITC）</p>
<p>FL2:585/40（PE）</p>
<p>FL3:630/30（PE-Texas Red/ECD/PI）</p>
<p>FL4:697/60（PerCP/PE-Cy5/PE-Cy5.5）</p>
<p>FL5:780/60（PE-Cy7）</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Fluorescence Sensitivity</td>
<td>FITC≤50 MESF, PE≤30MESF</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Fluorescence Linearity</td>
<td>≥0.99</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>FSC Sensitivity</td>
<td>≤1μm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Test Particle Size</td>
<td>0.2~50μm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Carry Over</td>
<td>≤0.5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Instrument CV</td>
<td>FSC and all FL channel CV less than 2%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>FSC and SSC CV</td>
<td>Can separate red blood cells and platelet, can separate white blood cells into 3 groups</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Test Speed</td>
<td>≥46000 cells/s</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Minimum Sample Vol</td>
<td>90μL</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Measure Range</td>
<td>Maximum Support 10⁷</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Threshold</td>
<td>Double threshold, minimum cells fraction</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Fluorescence Compensation</td>
<td>Support auto online compensation, offline compensation and visualized compensation</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Item Template</td>
<td>Support Item template, acquisition conditions/fluorescence compensation one-click use</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Intake Method</td>
<td>Manual intake</p>
<p>Rotary wheel auto-sampling with auto-mixing function:32tests/wheel</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Liquid Storage Station</td>
<td>Sheath bottle, waste bottle, shutdown liquid bottle 2L,</p>
<p>cleaning liquid bottle 0.5L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Software</td>
<td>English/Chinese</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>PC</td>
<td>Dell（CPU i5/8G DDR4/1T hard disk）+Dell 27 inches monitor</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power Supply</td>
<td>AC220/110V±10%, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Optional</td>
<td>Auto-sampler</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size(W*D*H)</td>
<td>430*500*330mm</p>
<p>650*500*330mm(with autosampler)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>30kg</p>
<p>35kg(with autosampler)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Packing Size(W*D*H)</td>
<td>Main Instrument: 860*635*648mm</p>
<p>Accessories: 860*680*810mm</p>
<p>Reagent: 405*270*400mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>Main Instrument: 56kg</p>
<p>Accessories: 54kg</p>
<p>Reagent: 16kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/flow-cytometer-zs-ae7s/">Flow Cytometer ZS-AE7S</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Automatic Chemistry &#038; Immunoassay Analyzer MT8600</title>
		<link>https://keylaser.am/product/automatic-chemistry-immunoassay-analyzer-mt8600/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 23 Mar 2026 08:05:51 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14958</guid>

					<description><![CDATA[<p><label>Model: </label>MT8600</p>
<p>The automatic chemistry &#38; immunoassay analyzer is a fully automated integrated platform that seamlessly connects the chemistry analyzer and immunoassay via a track system. It enables parallel processing of the same sample, completing both biochemical and immunoassay tests in a single operation.<br />
This system revolutionizes traditional workflows, significantly improving efficiency and minimizing manual operation and sample turnaround time. Simultaneously, by reducing human intervention, it effectively reduces result errors, ensuring a high degree of consistency and reliability in testing quality, making it a core piece of equipment in modern large-scale medical institution laboratories.</p>
<p>The post <a href="https://keylaser.am/product/automatic-chemistry-immunoassay-analyzer-mt8600/">Automatic Chemistry &#038; Immunoassay Analyzer MT8600</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" class="wp-image-14969 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/MT8600.webp" alt="Automatic Chemistry &amp; Immunoassay Analyzer MT8600" width="959" height="779" srcset="https://keylaser.am/wp-content/uploads/2026/03/MT8600.webp 959w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-300x244.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-768x624.webp 768w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-600x487.webp 600w" sizes="(max-width: 959px) 100vw, 959px" /></p>
<p><strong>Flexible Combination Mode</strong></p>
<p><strong>Dual-module</strong></p>
<p><strong>Single Chemistry Module + Single Immunoassay Module</strong></p>
<p>Chemistry: 2000 Tests/hour; Immunoassay: 600 Tests/hour; Electrolytes: 600 Tests/hour</p>
<p><img loading="lazy" decoding="async" class="wp-image-14963 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-8.webp" alt="Automatic Chemistry &amp; Immunoassay Analyzer MT8600" width="640" height="640" srcset="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-8.webp 640w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-8-300x300.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-8-150x150.webp 150w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-8-600x600.webp 600w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-8-100x100.webp 100w" sizes="auto, (max-width: 640px) 100vw, 640px" /></p>
<p><strong>Triple-module</strong></p>
<p><strong>Dual Chemistry Modules + Single Immunoassay Module</strong></p>
<p>Chemistry: 4000 Tests/hour; Immunoassay: 600 Tests/hour; Electrolytes: 1200 Tests/hour</p>
<p><strong>Single Chemistry Module + Dual Immunoassay Modules</strong></p>
<p>Chemistry: 2000 Tests/hour; Immunoassay: 1200 Tests/hour; Electrolytes: 600 Tests/hour</p>
<figure id="attachment_14962" aria-describedby="caption-attachment-14962" style="width: 640px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-14962 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-19.webp" alt="Automatic Chemistry &amp; Immunoassay Analyzer MT8600" width="640" height="640" srcset="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-19.webp 640w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-19-300x300.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-19-150x150.webp 150w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-19-600x600.webp 600w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-19-100x100.webp 100w" sizes="auto, (max-width: 640px) 100vw, 640px" /><figcaption id="caption-attachment-14962" class="wp-caption-text"><strong>Quadruple-module</strong><br /><strong>Dual Chemistry Modules + Dual Immunoassay Modules</strong><br />Chemistry: 4000 Tests/hour; Immunoassay: 1200 Tests/hour; Electrolytes: 1200 Tests/hour<br /><strong>Triple Chemistry Modules + Single Immunoassay Module</strong><br />Chemistry: 6000 Tests/hour; Immunoassay: 600 Tests/hour; Electrolytes: 1800 Tests/hour<br /><strong>Single Chemistry Module + Triple Immunoassay Modules</strong><br />Chemistry: 2000 Tests/hour; Immunoassay: 1800 Tests/hour; Electrolytes: 600 Tests/hour</figcaption></figure>
<p>&nbsp;</p>
<figure id="attachment_14961" aria-describedby="caption-attachment-14961" style="width: 640px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-14961 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-800-800-7.webp" alt="Automatic Chemistry &amp; Immunoassay Analyzer MT8600" width="640" height="640" srcset="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-800-800-7.webp 640w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-800-800-7-300x300.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-800-800-7-150x150.webp 150w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-800-800-7-600x600.webp 600w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-800-800-7-100x100.webp 100w" sizes="auto, (max-width: 640px) 100vw, 640px" /><figcaption id="caption-attachment-14961" class="wp-caption-text"> </figcaption></figure>
<figure id="attachment_14968" aria-describedby="caption-attachment-14968" style="width: 839px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-14968 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/MT8600-1.webp" alt="Automatic Chemistry &amp; Immunoassay Analyzer MT8600" width="839" height="444" srcset="https://keylaser.am/wp-content/uploads/2026/03/MT8600-1.webp 839w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-1-300x159.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-1-768x406.webp 768w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-1-600x318.webp 600w" sizes="auto, (max-width: 839px) 100vw, 839px" /><figcaption id="caption-attachment-14968" class="wp-caption-text"> </figcaption></figure>
<p><strong>Features</strong><strong>:</strong></p>
<p><strong>01/ Intelligent System Software</strong></p>
<p>Automatic retesting of abnormal samples</p>
<p>Intelligent sample scheduling</p>
<p>Automatic alarm handling</p>
<p>Automatic cleaning and maintenance</p>
<p>Reagent remaining level warning</p>
<p><strong>02/Sample Processing System</strong></p>
<p>Automatic sample rack type scanning</p>
<p>Sample quality identification (Optional)</p>
<p>Sample tube type identification</p>
<p>Maximum loading of 350 samples per batch</p>
<p>Emergency priority function</p>
<p><strong>03/Immunoassay System</strong></p>
<p>Tube-type magnetic microparticle enzymatic chemiluminescence</p>
<p>Non-contact mixing</p>
<p>Reagent and consumable loading and unloading without stopping the system</p>
<p>Single unit throughput 600 Tests/hour</p>
<p><strong>04/Chemistry System</strong></p>
<p>Reagent loading and unloading without system shutdown</p>
<p>Total reaction volume as low as 80μL</p>
<p>Single unit throughput 2000 Tests/hour</p>
<p>ISE module throughput 600 Tests/hour (Optional)</p>
<p>Emergency results reporting time as fast as 10min</p>
<p><strong>Technical Parameters</strong><strong>:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="882">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td colspan="2">Model</td>
<td>MT8600</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="13">Chemistry Analyzer Module</td>
<td>Throughput</td>
<td>2000 Tests/hour; Optional ISE module 600 Tests/hour</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Type</td>
<td>Serum, plasma, whole blood, urine, cerebrospinal fluid, semen, stool</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Loading Mode</td>
<td>Track loading, with emergency track</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Position</td>
<td>Maximum 350 samples loaded at one time, original tube loading with sample rack</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Position</td>
<td>250 positions, 2 cold storage functional reagent disks</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Volume</td>
<td>1~35μL, increasing by 0.1μL</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Volume</td>
<td>1~350μL</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Reaction Volume</td>
<td>80~350μL</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Probe</td>
<td>Liquid level sensing, random tracking, three-dimensional anti-collision protection</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Wavelength Range</td>
<td>340nm~850nm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reaction Temperature</td>
<td>Circulating water bath, constant temperature 37±0.1℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>External Dimensions(W*D*H)</td>
<td>1505*1225*1245mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Net Weight</td>
<td>500kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="11">Immunoassay Module</td>
<td>Throughput</td>
<td>600 Tests/hour</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reaction Principle</td>
<td>Tubular magnetic particle enzymatic chemiluminescence</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Type</td>
<td>Serum, plasma, urine</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Cleaning Module</td>
<td>Double cleaning module, triple magnetic separation cleaning technology, non-contact type mixing</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Reagent Position</td>
<td>Double reagent disks, 50 reagent positions, 2~8℃ cold storage</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reaction Tube Capacity</td>
<td>2000 reaction tubes, support random loading</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Incubation Position</td>
<td>A total of 238 incubation positions, 37±0.1℃, dry bath heating</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Sample Position</td>
<td>Maximum 350 samples loaded at one time, original tube loading with sample rack</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Other Functions</td>
<td>Reagent radio frequency identification, sample needle collision prevention, liquid level detection, automatic dilution, optional clot detection, etc.</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Dimensions(W*D*H)</td>
<td>1500*1225*1245mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>500kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4">Sample Loading Module</td>
<td>Sample Position</td>
<td>350 sample positions, 450 samples delivered per hour</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>STAT Function</td>
<td>Equipped with emergency priority function</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Dimensions(W*D*H)</td>
<td>972*1225*1495mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>160kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="3">Others</td>
<td>Power Supply</td>
<td>AC220 50/60Hz (Standard); AC110 50/60Hz (Optional), 4950VA</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Packing Size(W*D*H)</td>
<td>1685*1410*1460mm; 1685*1410*1460mm; 1410*1350*1170mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Gross Weight</td>
<td>670kg; 650kg; 360kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/automatic-chemistry-immunoassay-analyzer-mt8600/">Automatic Chemistry &#038; Immunoassay Analyzer MT8600</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Portable Veterinary Fluorescence Immunoassay Analyzer</title>
		<link>https://keylaser.am/product/portable-veterinary-fluorescence-immunoassay-analyzer/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 23 Mar 2026 07:48:33 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14950</guid>

					<description><![CDATA[<p><label>Model: </label>BKP500VET</p>
<p>The BKP500VET portable veterinary fluorescence immunoassay analyzer uses fluorescence immunoassay to accurately quantify specific analytes in animal serum, plasma, whole blood, or urine samples. This instrument features fast detection speed, compact portability, long battery life, and supports barcode recognition and intelligent data management. It is suitable for use in research institutes, animal experimental centers, animal and plant quarantine departments, veterinary hospitals, and livestock and veterinary systems.</p>
<p>The post <a href="https://keylaser.am/product/portable-veterinary-fluorescence-immunoassay-analyzer/">Portable Veterinary Fluorescence Immunoassay Analyzer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. Lightweight and compact, handheld design.</p>
<p>2. Long battery life: built-in high-performance lithium battery, providing up to 4 hours of continuous operation.</p>
<p>3. Single test completed in just 8 seconds; supports multiple tests per card, significantly improving work efficiency.</p>
<p>4. Equipped with a 5.0-inch color touchscreen, user-friendly interface, rapid response, and intuitive workflow.</p>
<p>5. Large storage capacity: can store over 100,000 data entries.</p>
<p>6. Optional thermal printer available.</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BKP500VET</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reaction Principle</td>
<td>Fluorescence Immunoassay</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Detection Channel</td>
<td>Single Channel</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Detecting Animal</td>
<td>Cat, dog</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Detection Speed</td>
<td>&lt;8 seconds per test</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Detection Mode</td>
<td>Single-item per card; Multi-item combined detection per card</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Type</td>
<td>20 customizable sample types (Whole blood, serum, plasma, urine, etc.)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Screen Size</td>
<td>5.0-inch color touchscreen</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Data Storage Capacity</td>
<td>&gt;100,000pcs</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Printer</td>
<td>External (Bluetooth/USB) thermal printer (Optional)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Barcode Scanning</td>
<td>1D code, 2D code</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Battery Life (Full Charge)</td>
<td>Continuous operation for 4 hours</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Data Transmission</td>
<td>LIS, WIFI, USB, Bluetooth; 4G (Optional)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power Supply</td>
<td>AC100~240V, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Instrument Size(W*D*H)</td>
<td>210*90*45mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Net Weight</td>
<td>0.75kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Packing Size(W*D*H)</td>
<td>250*160*145mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Gross Weight</td>
<td>2.5kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/portable-veterinary-fluorescence-immunoassay-analyzer/">Portable Veterinary Fluorescence Immunoassay Analyzer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fibrinogen (FIB) Assay Kit</title>
		<link>https://keylaser.am/product/fibrinogen-fib-assay-kit/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 23 Mar 2026 06:17:49 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14872</guid>

					<description><![CDATA[<p><label>Model: </label>FIB</p>
<p>Fibrinogen is the main protein in the coagulation process. In addition to the stress response under physiological conditions and the third trimester of pregnancy, FIB increase mainly occurs in acute infections, burns, atherosclerosis, acute myocardial infarction, autoimmune diseases, multiple Myeloma, diabetes, pregnancy-induced hypertension and acute nephritis, uremia, etc.; FIB reduction is mainly seen in DIC, primary hyperthyroidism, severe hepatitis, liver cirrhosis and thrombolytic therapy.<br />
This kit is used to quantitatively determine the content of fibrinogen in human plasma in vitro for auxiliary diagnosis.</p>
<p>The post <a href="https://keylaser.am/product/fibrinogen-fib-assay-kit/">Fibrinogen (FIB) Assay Kit</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. Stable performance.</p>
<p>2. Good precision.</p>
<p>3. Easy to transport.</p>
<p><strong>T</strong><strong>echnical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td colspan="2">Product Name</td>
<td>Fibrinogen(FIB) Assay Kit</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Component</td>
<td>Reagent: 2ml*5, 2.5ml*5, 1ml*10</p>
<p>Diluent: 50ml*2</p>
<p>Calibrator: 0.5ml*1, 1.0ml*1</p>
<p>QC(normal, abnormal): 0.5 ml*1, 1.0 ml*1</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Reagent Performance</td>
<td>Accuracy</td>
<td>R≤15%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Linearity</td>
<td>R&gt;0.98@80~500mg/dl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Repeatability</td>
<td>CV≤8%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Batch Variations</td>
<td>CV≤15%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Calibrator Performance</td>
<td>Correctness</td>
<td>|En| ≤1</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>In-bottle Uniformity</td>
<td>CV≤10%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Uniformity Between Bottles</td>
<td>CV≤10%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="2">QC Performance</td>
<td>In-bottle Uniformity</td>
<td>CV≤10%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Uniformity between Bottles</td>
<td>CV≤10%</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/fibrinogen-fib-assay-kit/">Fibrinogen (FIB) Assay Kit</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Thrombin Time (TT) Assay Kit</title>
		<link>https://keylaser.am/product/thrombin-time-tt-assay-kit/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 23 Mar 2026 06:14:26 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14866</guid>

					<description><![CDATA[<p>&#160;</p>
<p><label>Model: </label>TT</p>
<p>Activated partial thromboplastin time(APTT) is a screening test to check endogenous coagulation factors, and is used to confirm the deficiencies of congenital or acquired coagulation factors VI, IX, XI or the presence of their corresponding inhibitors; At the same time, APTT can also be used to confirm the deficiency of coagulation factor XI, prokallikrein and high molecular weight prokallikrein; due to the high sensitivity of APTT and the action pathway of heparin is mainly the endogenous coagulation pathway, APTT has become the preferred indicator for monitoring unfractionated heparin, with a ratio of 1.5~2.5 being the best.<br />
This kit is used for the determination of activated partial thromboplastin time in human plasma in vitro for auxiliary diagnosis.</p>
<p>The post <a href="https://keylaser.am/product/thrombin-time-tt-assay-kit/">Thrombin Time (TT) Assay Kit</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. Good stability.</p>
<p>2. Complete specifications.</p>
<p>3. High precision.</p>
<p><strong>T</strong><strong>echnical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td colspan="2">Product Name</td>
<td>Thrombin Time(TT) Assay Kit</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Component</td>
<td>Reagent: 2ml*10, 2.5ml*10, 4ml*10</p>
<p>Reconstitution solution: 25ml*1, 30ml*1, 45ml*1</p>
<p>QC(normal, abnormal): 0.5ml*1, 1.0ml*1</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Reagent Performance</td>
<td>Reference Range</td>
<td>≤20s</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Repeatability</td>
<td>CV≤5%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Batch Variations</td>
<td>R≤10%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="2">QC Performance</td>
<td>In-bottle Uniformity</td>
<td>CV≤10%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Uniformity Between Bottles</td>
<td>CV≤10%</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/thrombin-time-tt-assay-kit/">Thrombin Time (TT) Assay Kit</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Prothrombin Time(PT) Assay Kit</title>
		<link>https://keylaser.am/product/prothrombin-timept-assay-kit/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 23 Mar 2026 06:10:18 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14860</guid>

					<description><![CDATA[<p>Activated partial thromboplastin time(APTT) is a screening test to check endogenous coagulation factors, and is used to confirm the deficiencies of congenital or acquired coagulation factors VI, IX, XI or the presence of their corresponding inhibitors; At the same time, APTT can also be used to confirm the deficiency of coagulation factor XI, prokallikrein and high molecular weight prokallikrein; due to the high sensitivity of APTT and the action pathway of heparin is mainly the endogenous coagulation pathway, APTT has become the preferred indicator for monitoring unfractionated heparin, with a ratio of 1.5~2.5 being the best.<br />
This kit is used for the determination of activated partial thromboplastin time in human plasma in vitro for auxiliary diagnosis.</p>
<p>The post <a href="https://keylaser.am/product/prothrombin-timept-assay-kit/">Prothrombin Time(PT) Assay Kit</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. High precision.</p>
<p>2. Stable performance.</p>
<p>3. Strong anti-interference.</p>
<p><strong>T</strong><strong>echnical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td colspan="2">Product Name</td>
<td>Prothrombin Time(PT) Assay Kit</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Component</td>
<td>Reagent: 2ml*10, 2.5ml*10, 4ml*10</p>
<p>Reconstitution Solution: 25ml*1, 30ml*1, 45ml*1</p>
<p>QC(normal, abnormal): 0.5ml*1, 1.0ml*1</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Reagent Performance</td>
<td>Reference Range</td>
<td>≤14s</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Repeatability</td>
<td>CV≤5%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Batch Variations</td>
<td>R≤10%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="2">QC Performance</td>
<td>In-bottle Uniformity</td>
<td>CV≤10%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Uniformity Between Bottles</td>
<td>CV≤10%</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/prothrombin-timept-assay-kit/">Prothrombin Time(PT) Assay Kit</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Activated Partial Thromboplastin Time(APTT) Assay Kit</title>
		<link>https://keylaser.am/product/activated-partial-thromboplastin-timeaptt-assay-kit/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 19 Mar 2026 16:04:07 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14854</guid>

					<description><![CDATA[<p>Activated partial thromboplastin time(APTT) is a screening test to check endogenous coagulation factors, and is used to confirm the deficiencies of congenital or acquired coagulation factors VI, IX, XI or the presence of their corresponding inhibitors; At the same time, APTT can also be used to confirm the deficiency of coagulation factor XI, prokallikrein and high molecular weight prokallikrein; due to the high sensitivity of APTT and the action pathway of heparin is mainly the endogenous coagulation pathway, APTT has become the preferred indicator for monitoring unfractionated heparin, with a ratio of 1.5~2.5 being the best.<br />
This kit is used for the determination of activated partial thromboplastin time in human plasma in vitro for auxiliary diagnosis.</p>
<p>The post <a href="https://keylaser.am/product/activated-partial-thromboplastin-timeaptt-assay-kit/">Activated Partial Thromboplastin Time(APTT) Assay Kit</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. Convenient and efficient.</p>
<p>2. High accuracy.</p>
<p>3. Good repeatability.</p>
<p><strong>T</strong><strong>echnical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td colspan="2">Product Name</td>
<td>Activated Partial Thromboplastin Time(APTT) Assay Kit</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Component</td>
<td>Reagent: 2ml*10, 2.5ml*10, 4ml*10</p>
<p>CaCl2: 25ml*1, 30ml*1, 45ml*1</p>
<p>QC(normal, abnormal): 0.5ml*1, 1.0ml*1</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Reagent Performance</td>
<td>Reference Range</td>
<td>≤35s</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Repeatability</td>
<td>CV≤5%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Batch Variations</td>
<td>R≤10%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="2">QC Performance</td>
<td>In-bottle Uniformity</td>
<td>CV≤10%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Uniformity Between Bottles</td>
<td>CV≤10%</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/activated-partial-thromboplastin-timeaptt-assay-kit/">Activated Partial Thromboplastin Time(APTT) Assay Kit</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Reagent for Electrolyte Analyzer(ISE)</title>
		<link>https://keylaser.am/product/reagent-for-electrolyte-analyzerise/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 19 Mar 2026 16:00:40 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14850</guid>

					<description><![CDATA[<div class="pro-this-prodBrief">Electrolyte reagents are suitable for BKE series (BKE-A, BKE-B, BKE-C, BKE-D) electrolyte analyzers. It is used for quantitative detection of K+, Na+, Cl-, Ca2+ and pH in serum.</div>
<p>The post <a href="https://keylaser.am/product/reagent-for-electrolyte-analyzerise/">Reagent for Electrolyte Analyzer(ISE)</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. High quality raw materials.</p>
<p>2. Stable performance.</p>
<p>3. Long shelf life.</p>
<p>4. Multiple specifications optional.</p>
<p><strong>T</strong><strong>echnical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Product Name</td>
<td>Reagent for Electrolyte Analyzer(ISE)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Component</td>
<td>Drift correction solution A(350ml)</p>
<p>Slope correction solution B(350ml)</p>
<p>Reference solution(10ml*2)</p>
<p>Filling solution in electrode(3ml)</p>
<p>Cleaning fluid E(100ml)</p>
<p>Electrode activation fluid(100ml)</p>
<p>Internal correction solution(100ml)</p>
<p>Electrode cleaning fluid(protease): Protease: 25mg*5; Diluent: 5ml*1</p>
<p>Drift correction solution(CO<sub>2</sub> standard 1): 100ml*1(only for BKE-E/F/L)</p>
<p>Slope correction solution(CO<sub>2</sub> standard 2): 100ml*1(only for BKE-E/F/L)</p>
<p>CO<sub>2 </sub>acidic washing: 100ml*1(only for BKE-E/F/L)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Precision</td>
<td>TCO<sub>2, </sub>Mg<sup>2+</sup> repeatability CV<a name="OLE_LINK7"></a><a name="OLE_LINK7"></a>≤3.5%; Batch variations R≤5%</p>
<p>iCa<sup>2+</sup><sub>, </sub>Li<sup>+</sup> repeatability CV≤1.5%; Batch variations R≤3%</p>
<p>Others repeatability CV≤1.5%; Batch variations R≤2%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Accuracy</td>
<td>K<sup>+</sup>, Na<sup>+</sup>, Cl<sup>&#8211;</sup>, pH<sup> </sup>relative deviation≤±3.0%</p>
<p>iCa<sup>2+</sup><sub>, </sub>Li<sup>+</sup>, Mg<sup>2+</sup><sup> </sup>relative deviation≤±5%, or≤±0.05mmol/L</p>
<p>TCO<sub>2</sub> relative deviation≤±5%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Linearity</td>
<td>r≥0.995</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size(L*W*H)mm</td>
<td>Commodity inspection reagent:</p>
<p>220*160*120(only for BKE-A/B/C/D), 280*135*210(only for BKE-E/F/L)</p>
<p>Non-commodity inspection reagent: 220*160*120</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight(kg)</td>
<td>Commodity inspection reagent:</p>
<p>1.7(only for BKE-A/B/C/D), 2.2(only for BKE-E/F/L)</p>
<p>Non-commodity inspection reagent:</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/reagent-for-electrolyte-analyzerise/">Reagent for Electrolyte Analyzer(ISE)</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Automatic Urine Analyzer</title>
		<link>https://keylaser.am/product/automatic-urine-analyzer/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 19 Mar 2026 15:23:01 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14805</guid>

					<description><![CDATA[<p><label>Model: </label>BH-QNY01 BH-QNY02</p>
<p>Urine analyzer is an automatic instrument for the determination of certain chemical components in urine. It is an important tool for automated urine inspection in medical laboratory. It has the advantages of simple operation and fast operation. Under the control of the computer, the instrument collects and analyzes the color information of various reagent blocks on the test belt, and converts a series of signals to output the chemical composition content in the urine.</p>
<p>The post <a href="https://keylaser.am/product/automatic-urine-analyzer/">Automatic Urine Analyzer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. Built-in 10.1-inch touch screen, built-in thermal printer.</p>
<p>2. Sample delivery, injection, droplet, analysis and report output are completed automatically by the instrument.</p>
<p>3. High-precision sample dispenser is used to ensure thorough reaction and improve the accuracy of test results.</p>
<p>4. Automatic strip selection chamber, accommodating 600 test strips at the same time.</p>
<p>5. Supports closed puncture analysis, greatly improving biosafety.</p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BH-QNY01</td>
<td>BH-QNY02</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="1" rowspan="1">Cascade Function</td>
<td colspan="1" rowspan="1">No</td>
<td colspan="1" rowspan="1">Yes</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Principle</td>
<td colspan="2">Photoelectric colorimetry</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Throughput</td>
<td colspan="2" rowspan="1">240 tests/hour</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Screen</td>
<td colspan="2">10.1-inch touch screen</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Memory</td>
<td colspan="2">Can store more than 1,000,000 test reports</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Printer</td>
<td colspan="2">Built-in thermal printer</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Interface</td>
<td colspan="2">USB, RS232, network interface</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Barcode Scanner</td>
<td colspan="2">Can be optional</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Range of Application</td>
<td colspan="2">9, 10, 11, 14 test strip</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Items</td>
<td colspan="2">9 test strip: GLU, BIL, KET, pH, BLD, PRO, URO, NIT, LEU</p>
<p>10 test strip: GLU, BIL, KET, SG, pH, BLD, PRO, URO, NIT, LEU</p>
<p>11 test strip: GLU, BIL, KET, SG, pH, BLD, PRO, URO, NIT, LEU, VC</p>
<p>14 test strip: GLU, BIL, KET, SG, pH, BLD, PRO, URO, NIT, LEU, VC, CRE, CAL, MCA</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Sample Rack Capacity</td>
<td colspan="2">100pcs samples(10pcs test tube racks)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Reagent Tank Capacity</td>
<td colspan="2">600pcs</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Data Retrieval</td>
<td colspan="2">Can be searched by actual date, range date, urine sample number, name, barcode, etc.</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Automatic Sensing</td>
<td colspan="2">Automatically detects and analyzes after placing the sample</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Calibration Function</td>
<td colspan="2">Yes</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Power</td>
<td colspan="2">130W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power Supply</td>
<td colspan="2">AC100~240V, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>External Size(W*D*H)</td>
<td>662*730*520mm</td>
<td>662*780*520mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Net Weight</td>
<td>48kg</td>
<td>51.5kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Packing Size(W*D*H)</td>
<td>805*880*600mm;</p>
<p>430*340*590mm</td>
<td>805*880*600mm;</p>
<p>430*340*590mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Gross Weight</td>
<td>76.5kg; 15kg</td>
<td>80kg; 15kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
<p><strong>Remark: </strong>The machine comes standard with 100 test strips.</p>