<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Flow Cytometer Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-category/biobase/clinicalanalytical-instrument/flow-cytometer/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-category/biobase/clinicalanalytical-instrument/flow-cytometer/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Mon, 23 Mar 2026 08:59:31 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>Flow Cytometer Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-category/biobase/clinicalanalytical-instrument/flow-cytometer/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Flow Cytometer B7H FlowCyte B7</title>
		<link>https://keylaser.am/product/flow-cytometer-b7h-flowcyte-b7/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 23 Mar 2026 08:59:31 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14987</guid>

					<description><![CDATA[<p><label>Model: </label>B7H FlowCyte B7</p>
<p>Flow cytometer is a high-precision analytical and sorting instrument widely used in life sciences, medicine, immunology, and other fields. It integrates fluid mechanics, optics, electronics, and computer technology to rapidly analyze and sort individual cells (or particles) in a liquid suspension. By detecting scattered light signals and fluorescent signals from cells labeled with specific probes, the instrument can quantitatively measure multiple physical and chemical properties of cells (such as size, granularity, surface antigens, and intracellular components) at a speed of thousands to tens of thousands of cells per second, enabling high-throughput, multi-parameter, and non-destructive cellular analysis.</p>
<p>The post <a href="https://keylaser.am/product/flow-cytometer-b7h-flowcyte-b7/">Flow Cytometer B7H FlowCyte B7</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img fetchpriority="high" decoding="async" class="alignnone wp-image-14990 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-18.webp" alt="Flow Cytometer B7H FlowCyte B7" width="1139" height="894" srcset="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-18.webp 1139w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-18-300x235.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-18-1024x804.webp 1024w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-18-768x603.webp 768w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-18-600x471.webp 600w" sizes="(max-width: 1139px) 100vw, 1139px" /></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Item</td>
<td>Recommended Reagent</td>
<td>Application Department</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Lymphocyte Subset T Analysis</td>
<td>CD45</p>
<p>CD4</p>
<p>CD3</p>
<p>CD8</td>
<td rowspan="2">Clinical Laboratory</p>
<p>Infectious Disease Department</p>
<p>Oncology Department</p>
<p>Department of Rheumatology and Immunology</p>
<p>Department of Pediatrics Blood Specialty</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Lymphocyte Subset T/B/NK Analysis</td>
<td>CD45</p>
<p>CD3</p>
<p>CD16</p>
<p>CD56</p>
<p>CD19</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Absolute Count of CD4+T Lymphocyte</td>
<td>CD45</p>
<p>CD4</p>
<p>CD3</p>
<p>CD8</td>
<td>CDC (AIDS)</p>
<p>Infectious Disease Department</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Cytokine Th1/Th2/Th17 Analysis</td>
<td>Th1: IL-2, IFN-γ, TNF-α</p>
<p>Th2: IL-4, IL-6, IL-10</p>
<p>Th17: IL-17</td>
<td>Infectious Disease Department</p>
<p>Oncology Department</p>
<p>Department of Rheumatology and Immunology</p>
<p>Department of Organ Transplantation</p>
<p>Respiratory Department</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>HLA-B27 Detection for AS</td>
<td>HLA-B27-FITC</p>
<p>HLA-B7-PE</p>
<p>IgG2a-FITC</p>
<p>IgG1-PE</td>
<td>Department of Rheumatology and Immunology</p>
<p>Orthopedics</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>DFI Analysis</td>
<td>Acridine orange (AO) Staining Solution</td>
<td>Reproductive Department</p>
<p>Infertility Department</p>
<p>Reproductive Medicine Centre</td>
</tr>
</tbody>
</table>
</div>
</div>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index1">
<div class="inner">
<table width="882">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>FlowCyte B7H</td>
<td>FlowCyte B7</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Laser</td>
<td colspan="2">488nm solid（60mW）</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Detector</td>
<td colspan="2">FSC, SSC, FL1-FL5</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Fluorescence Channel</td>
<td colspan="2">FL1:525/50（FITC）</p>
<p>FL2:585/40（PE）</p>
<p>FL3:630/30（PE-Texas Red/ECD/PI）</p>
<p>FL4:697/60（PerCP/PE-Cy5/PE-Cy5.5）</p>
<p>FL5:780/60（PE-Cy7）</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Fluorescence Sensitivity</td>
<td colspan="2">FITC≤50 MESF, PE≤30MESF</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Fluorescence Linearity</td>
<td colspan="2">≥0.99</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>FSC Sensitivity</td>
<td colspan="2">≤1μm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Test Particle Size</td>
<td colspan="2">0.2~50μm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Carry Over</td>
<td colspan="2">≤0.5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Instrument CV</td>
<td colspan="2">FSC and all FL channel CV less than 2%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>FSC and SSC CV</td>
<td colspan="2">Can separate red blood cells and platelet, can separate white blood cells into 3 groups</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Test Speed</td>
<td colspan="2">≥46000 cells/s</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Minimum Sample Vol</td>
<td colspan="2">90μL</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Measure Range</td>
<td colspan="2">Maximum Support 10⁷</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Threshold</td>
<td colspan="2">Double threshold, minimum cells fraction</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Fluorescence Compensation</td>
<td colspan="2">Support auto online compensation, offline compensation and visualized compensation</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Item Template</td>
<td colspan="2">Support Item template, acquisition conditions/fluorescence compensation one-click use</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Intake Method</td>
<td colspan="2">Manual intake</p>
<p>Rotary wheel auto-sampling with auto-mixing function:32tests/wheel</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Liquid Storage Station</td>
<td colspan="2">Sheath bottle, waste bottle, shutdown liquid bottle 2L,</p>
<p>cleaning liquid bottle 0.5L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Software</td>
<td colspan="2">English/Chinese</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>PC</td>
<td colspan="2">Dell（CPU i5/8G DDR4/1T hard disk）+Dell 27 inches monitor</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power Supply</td>
<td colspan="2">AC220/110V±10%, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Auto-sampler</td>
<td>/</td>
<td>32-postions autosampler(Stanndard)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size(W*D*H)</td>
<td>430*500*330mm</td>
<td>650*500*330mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>30kg</td>
<td>35kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Packing Size(W*D*H)</td>
<td colspan="2">Main Instrument: 860*635*648mm</p>
<p>Accessories: 860*680*810mm</p>
<p>Reagent: 405*270*400mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td colspan="2">Main Instrument: 56kg</p>
<p>Accessories: 54kg</p>
<p>Reagent: 16kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/flow-cytometer-b7h-flowcyte-b7/">Flow Cytometer B7H FlowCyte B7</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Flow Cytometer ZS-AE7S</title>
		<link>https://keylaser.am/product/flow-cytometer-zs-ae7s/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 23 Mar 2026 08:36:02 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14980</guid>

					<description><![CDATA[<p><label>Model: </label>ZS-AE7S</p>
<p>Flow cytometer is a high-precision analytical and sorting instrument widely used in life sciences, medicine, immunology, and other fields. It integrates fluid mechanics, optics, electronics, and computer technology to rapidly analyze and sort individual cells (or particles) in a liquid suspension. By detecting scattered light signals and fluorescent signals from cells labeled with specific probes, the instrument can quantitatively measure multiple physical and chemical properties of cells (such as size, granularity, surface antigens, and intracellular components) at a speed of thousands to tens of thousands of cells per second, enabling high-throughput, multi-parameter, and non-destructive cellular analysis.</p>
<p>The post <a href="https://keylaser.am/product/flow-cytometer-zs-ae7s/">Flow Cytometer ZS-AE7S</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" class="wp-image-14982 size-large" src="https://keylaser.am/wp-content/uploads/2026/03/MT8600-2-1024x772.webp" alt="Flow Cytometer ZS-AE7S" width="1024" height="772" srcset="https://keylaser.am/wp-content/uploads/2026/03/MT8600-2-1024x772.webp 1024w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-2-300x226.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-2-768x579.webp 768w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-2-600x452.webp 600w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-2.webp 1199w" sizes="(max-width: 1024px) 100vw, 1024px" /></p>
<p><strong>Recommended Reagent Information:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Item</td>
<td>Recommended Reagent</td>
<td>Application Department</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Lymphocyte Subset T Analysis</td>
<td>CD45</p>
<p>CD4</p>
<p>CD3</p>
<p>CD8</td>
<td rowspan="2">Clinical Laboratory</p>
<p>Infectious Disease Department</p>
<p>Oncology Department</p>
<p>Department of Rheumatology and Immunology</p>
<p>Department of Pediatrics Blood Specialty</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Lymphocyte Subset T/B/NK Analysis</td>
<td>CD45</p>
<p>CD3</p>
<p>CD16</p>
<p>CD56</p>
<p>CD19</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Absolute Count of CD4+T Lymphocyte</td>
<td>CD45</p>
<p>CD4</p>
<p>CD3</p>
<p>CD8</td>
<td>CDC (AIDS)</p>
<p>Infectious Disease Department</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Cytokine Th1/Th2/Th17 Analysis</td>
<td>Th1: IL-2, IFN-γ, TNF-α</p>
<p>Th2: IL-4, IL-6, IL-10</p>
<p>Th17: IL-17</td>
<td>Infectious Disease Department</p>
<p>Oncology Department</p>
<p>Department of Rheumatology and Immunology</p>
<p>Department of Organ Transplantation</p>
<p>Respiratory Department</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>HLA-B27 Detection for AS</td>
<td>HLA-B27-FITC</p>
<p>HLA-B7-PE</p>
<p>IgG2a-FITC</p>
<p>IgG1-PE</td>
<td>Department of Rheumatology and Immunology</p>
<p>Orthopedics</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>DFI Analysis</td>
<td>Acridine orange (AO) Staining Solution</td>
<td>Reproductive Department</p>
<p>Infertility Department</p>
<p>Reproductive Medicine Centre</td>
</tr>
</tbody>
</table>
</div>
</div>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index1">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>ZS-AE7S</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Laser</td>
<td>488nm solid（60mW）</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Detector</td>
<td>FSC, SSC, FL1-FL5</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Fluorescence Channel</td>
<td>FL1:525/50（FITC）</p>
<p>FL2:585/40（PE）</p>
<p>FL3:630/30（PE-Texas Red/ECD/PI）</p>
<p>FL4:697/60（PerCP/PE-Cy5/PE-Cy5.5）</p>
<p>FL5:780/60（PE-Cy7）</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Fluorescence Sensitivity</td>
<td>FITC≤50 MESF, PE≤30MESF</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Fluorescence Linearity</td>
<td>≥0.99</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>FSC Sensitivity</td>
<td>≤1μm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Test Particle Size</td>
<td>0.2~50μm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Carry Over</td>
<td>≤0.5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Instrument CV</td>
<td>FSC and all FL channel CV less than 2%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>FSC and SSC CV</td>
<td>Can separate red blood cells and platelet, can separate white blood cells into 3 groups</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Test Speed</td>
<td>≥46000 cells/s</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Minimum Sample Vol</td>
<td>90μL</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Measure Range</td>
<td>Maximum Support 10⁷</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Threshold</td>
<td>Double threshold, minimum cells fraction</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Fluorescence Compensation</td>
<td>Support auto online compensation, offline compensation and visualized compensation</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Item Template</td>
<td>Support Item template, acquisition conditions/fluorescence compensation one-click use</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Intake Method</td>
<td>Manual intake</p>
<p>Rotary wheel auto-sampling with auto-mixing function:32tests/wheel</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Liquid Storage Station</td>
<td>Sheath bottle, waste bottle, shutdown liquid bottle 2L,</p>
<p>cleaning liquid bottle 0.5L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Software</td>
<td>English/Chinese</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>PC</td>
<td>Dell（CPU i5/8G DDR4/1T hard disk）+Dell 27 inches monitor</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power Supply</td>
<td>AC220/110V±10%, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Optional</td>
<td>Auto-sampler</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size(W*D*H)</td>
<td>430*500*330mm</p>
<p>650*500*330mm(with autosampler)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>30kg</p>
<p>35kg(with autosampler)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Packing Size(W*D*H)</td>
<td>Main Instrument: 860*635*648mm</p>
<p>Accessories: 860*680*810mm</p>
<p>Reagent: 405*270*400mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>Main Instrument: 56kg</p>
<p>Accessories: 54kg</p>
<p>Reagent: 16kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/flow-cytometer-zs-ae7s/">Flow Cytometer ZS-AE7S</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>