<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Aging Test Instruments Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-category/scitek/aging-test-instruments/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-category/scitek/aging-test-instruments/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Thu, 20 Mar 2025 06:21:59 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>Aging Test Instruments Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-category/scitek/aging-test-instruments/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Ozone Aging Test Chamber</title>
		<link>https://keylaser.am/product/ozone-aging-test-chamber/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 20 Mar 2025 06:20:50 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=13381</guid>

					<description><![CDATA[<p><strong>Model : OATC-01; OATC-02; OATC-03; OATC-04; OATC-05; OATC-06; OATC-07; OATC-08</strong></p>
<p>Temperature Range : 0℃～70℃<br />
Humidity Range : 30～65%R.H<br />
Ozone Concentration : 20~1000pphm</p>
<div>Tester : Dynamic and static (optional)<br />
Sample Frame Speed : 360 ° rotation of sample rack (1 rpm)</div>
<p>The post <a href="https://keylaser.am/product/ozone-aging-test-chamber/">Ozone Aging Test Chamber</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The ozone content in the atmosphere isn&#8217;t usually the main cause of rubber cracking. The ozone aging test chamber is used to simulate and intensify ozone environments, helping study its effect on rubber. It allows for quick identification and evaluation of rubber&#8217;s resistance to ozone aging and helps determine effective anti-aging measures to improve the lifespan of rubber products. This series of products is suitable for testing non-metallic and organic materials (such as coatings, rubber, plastics, paints, and pigments) under ozone conditions.</p>
<h2><strong>Ozone Aging Test Chamber Specifications:</strong></h2>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="1465">
<thead>
<tr class="firstRow">
<th colspan="2" width="191.33333333333334">Model</th>
<th width="33">OATC-01</th>
<th>OATC-02</th>
<th>OATC-03</th>
<th>OATC-04</th>
<th>OATC-05</th>
<th>OATC-06</th>
<th>OATC-07</th>
<th>OATC-08</th>
</tr>
</thead>
<tbody>
<tr>
<td colspan="2" width="191.33333333333334">Chamber Size (W×D×H)(mm)</td>
<td width="33">500×500×400</td>
<td>500×500×500</td>
<td>500×500×600</td>
<td>500×600×750</td>
<td>600×600×800</td>
<td>700×800×900</td>
<td>800×1000×1000</td>
<td>1000×1000×1000</td>
</tr>
<tr>
<td colspan="2" width="191.33333333333334">External Size(W×D×H)(mm)</td>
<td width="33">920×940×1680</td>
<td>1030×1010×1720</td>
<td>1100×1030×1880</td>
<td>1140×1120×1950</td>
<td>1190×1100×1950</td>
<td>1250×1300×2030</td>
<td>1290x1500x2140</td>
<td>1490×1500×2140</td>
</tr>
<tr>
<td colspan="2" width="191.33333333333334">Power(KW)</td>
<td width="33">4.5</td>
<td>5</td>
<td>5.5</td>
<td>6</td>
<td>6</td>
<td>6.5</td>
<td>7</td>
<td>8</td>
</tr>
<tr>
<td colspan="1" rowspan="4" width="67.33333333333333">Performance</td>
<td width="63">Temperature Range</td>
<td colspan="8">0℃～70℃</td>
</tr>
<tr>
<td width="30">Humidity Range</td>
<td colspan="8">30～65%R.H</td>
</tr>
<tr>
<td width="30">Ozone Concentration</td>
<td colspan="8">20~1000pphm</td>
</tr>
<tr>
<td width="30">Temperature Fluctuation</td>
<td colspan="8">±0.5℃</td>
</tr>
<tr>
<td colspan="1" rowspan="7" width="30">Run the Control System</td>
<td width="33">Tester</td>
<td colspan="8">Dynamic and static (optional)</td>
</tr>
<tr>
<td width="33">Sample Frame Speed</td>
<td colspan="8">360 ° rotation of sample rack (1 rpm)</td>
</tr>
<tr>
<td width="33">Gas Flow Rate</td>
<td colspan="8">12～16mm/s</td>
</tr>
<tr>
<td width="33">Temperature Controller</td>
<td colspan="8">Imported LED display P.I.D + S.S.R. Microcomputer integrated controller</td>
</tr>
<tr>
<td width="33">Time Controller</td>
<td colspan="8">High precision hour, minute, second time controller</td>
</tr>
<tr>
<td width="33">Ozone Concentration Analysis</td>
<td colspan="8">Import concentration analysis regulator 4 ~ 20 mA output, RS232 communication port</td>
</tr>
<tr>
<td width="33">Ozonizer</td>
<td colspan="8">Silent discharge tube type / UV absorption type (optional)</td>
</tr>
<tr>
<td colspan="2" width="191.33333333333334">Security Guard</td>
<td colspan="8" width="33">Leakage, short circuit, overtemperature, motor overheating, over-current protection</td>
</tr>
<tr>
<td colspan="2" width="191.33333333333334">Shipping Size (W×D×H)(mm)</td>
<td width="33">980×1000×1800</td>
<td>1090×1070×1840</td>
<td>1160×1090×2000</td>
<td>1200×1180×2070</td>
<td>1250×1160×2070</td>
<td>1310×1360×2150</td>
<td>1350×1560×2260</td>
<td>1550×1560×2260</td>
</tr>
<tr>
<td colspan="2" width="191.33333333333334">N.W/G.W(kg)</td>
<td width="33">188/239</td>
<td>223/265</td>
<td>260/325</td>
<td>325/378</td>
<td>330/445</td>
<td>410/490</td>
<td>445/670</td>
<td>635/780</td>
</tr>
</tbody>
</table>
</div>
<h2><strong>Ozone Aging Test Chamber Feature:</strong></h2>
<ol class=" list-paddingleft-2">
<li>Stable technical indicators, reliable operation and convenient maintenance;</li>
<li>Large touch screen operation, the operation is easy to set value and actual value display;</li>
<li>Vacuum double glazing: large window design,  high brightness lighting, heating without fog;</li>
<li>Ozone concentration / temperature and humidity setting value control PID self-setting, convenient and reliable operation;</li>
<li>With a metrological verification and calibration interface;</li>
<li>Bill-Lambert Principle measurement application software (internationally recognized);</li>
<li>Keep interfaces for classical chemical test ozone concentration. Internal voltage stabilizing power supply;</li>
<li>Provide more interface options for programming and document processing, with large record volume;</li>
</ol>
</div>
<p>The post <a href="https://keylaser.am/product/ozone-aging-test-chamber/">Ozone Aging Test Chamber</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>UV Aging Test Chamber</title>
		<link>https://keylaser.am/product/uv-aging-test-chamber/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 20 Mar 2025 06:17:58 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=13377</guid>

					<description><![CDATA[<p><strong>Model : UATC-UV3</strong></p>
<p>Number of Lamps : 8<br />
Temperature Range : RT + 10℃ ~70℃<br />
Humidity Range : 75% RH<br />
Temperature Uniformity : ± 3℃</p>
<div>Chamber Size (WxDxH)(mm) : 1140x650x400</div>
<p>The post <a href="https://keylaser.am/product/uv-aging-test-chamber/">UV Aging Test Chamber</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>UV test data can help evaluate formula changes of new materials and confirm the durability of new materials. It is widely used in paints, inks, coatings, resins, plastics, rubber, printing and packaging, aluminum profiles, adhesives, automobiles, motorcycle industries, cosmetics, metal, electronics, electroplating, medicine, etc.</p>
<h2><strong>UV Aging Test Chamber Specifications:</strong></h2>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="700">
<thead>
<tr class="firstRow">
<th colspan="2">Model</th>
<th width="429.00000000000006">UATC-UV3</th>
</tr>
</thead>
<tbody>
<tr>
<td colspan="2">Chamber Size (WxDxH)(mm)</td>
<td width="429.00000000000006">1140x650x400</td>
</tr>
<tr>
<td colspan="2">External Size (WxDxH)(mm)</td>
<td width="429.00000000000006">1300x800x1550</td>
</tr>
<tr>
<td colspan="1" rowspan="3" width="112.33333333333333">Lamp Wavelength (Optional)</td>
<td width="88.33333333333333">Band 315-400nm</td>
<td>Irradiance 0.35-1.2W/m</td>
</tr>
<tr>
<td width="88.33333333333333">Band 280-315nm</td>
<td>Irradiance 0.35-1.2W/m</td>
</tr>
<tr>
<td width="88.33333333333333">Band 351-400nm</td>
<td>Irradiance 0.35-1.2W/m<sup>2</sup></td>
</tr>
<tr>
<td colspan="2">Number of Lamps</td>
<td width="429.00000000000006">8</td>
</tr>
<tr>
<td colspan="2">Lamp Power</td>
<td width="429.00000000000006">40W</td>
</tr>
<tr>
<td colspan="2">Lamp Life</td>
<td width="429.00000000000006">More than 1600 hours</td>
</tr>
<tr>
<td colspan="2">Temperature Range</td>
<td width="429.00000000000006">RT + 10℃ ~70℃</td>
</tr>
<tr>
<td colspan="2">Humidity Range</td>
<td width="429.00000000000006">75% RH</td>
</tr>
<tr>
<td colspan="2">Temperature Uniformity</td>
<td width="429.00000000000006">± 3℃</td>
</tr>
<tr>
<td colspan="2">Temperature Fluctuation</td>
<td width="429.00000000000006">± 0.5℃</td>
</tr>
<tr>
<td colspan="2">Blackboard Temperature</td>
<td width="429.00000000000006">50℃ ~63℃</td>
</tr>
<tr>
<td colspan="2">Distance Between Sample and Lamp</td>
<td width="429.00000000000006">50mm</td>
</tr>
<tr>
<td colspan="2">Center Distance within the Lamp Tube</td>
<td width="429.00000000000006">70mm</td>
</tr>
<tr>
<td colspan="2">Standard Test Piece Size</td>
<td width="429.00000000000006">75×150mm/42 pcs</td>
</tr>
<tr>
<td colspan="2">Irradiation Intensity</td>
<td width="429.00000000000006">0.35-1.2W/m<sup>2</sup> adjustable</td>
</tr>
<tr>
<td colspan="2">Test Time</td>
<td width="429.00000000000006">1～9999 H, M, S adjustable</td>
</tr>
<tr>
<td colspan="2">Safety Protection System</td>
<td width="429.00000000000006">Line sequence protection, leakage protection, over-temperature protection, abnormality protection.</td>
</tr>
<tr>
<td colspan="2">Power Supply</td>
<td width="429.00000000000006">220V; 50Hz</td>
</tr>
<tr>
<td colspan="2">Power</td>
<td width="429.00000000000006">4500W</td>
</tr>
<tr>
<td colspan="1" rowspan="2" width="112.33333333333333">Environmental Condition</td>
<td width="88.33333333333333">Temperature</td>
<td width="429.00000000000006">5℃～30℃</td>
</tr>
<tr>
<td width="88.33333333333333">Relative Temperature</td>
<td>≤85%RH</td>
</tr>
<tr>
<td colspan="1" rowspan="2" width="112.33333333333333">Material</td>
<td width="88.33333333333333">Inner material</td>
<td width="429.00000000000006">SUS304 stainless steel plate</td>
</tr>
<tr>
<td width="88.33333333333333">External material</td>
<td>SUS304 stainless steel shell or paint</td>
</tr>
<tr>
<td colspan="2">Control System</td>
<td width="429.00000000000006">Touch screen and PLC controller</td>
</tr>
<tr>
<td colspan="2">Water Source &amp; Consumption</td>
<td width="429.00000000000006">Distilled water 8L/day</td>
</tr>
<tr>
<td colspan="2">Shipping Size (W×D×H)(mm)</td>
<td width="429.00000000000006">1360x860x1670</td>
</tr>
<tr>
<td colspan="2">Gross Weight（kg）</td>
<td width="429.00000000000006">575</td>
</tr>
</tbody>
</table>
</div>
</div>
<h2><strong>UV Aging Test Chamber Feature:</strong></h2>
<ol class=" list-paddingleft-2">
<li>UV aging test chamber can simulate the harm caused by sunlight, rain, and dew.</li>
<li>Fluorescent UV lamp to simulate the effect of sunlight, and condensing moisture to simulate rain and dew.</li>
<li>The test samples are tested in a cycle program of alternating light and moisture at a set temperature.</li>
</ol>
<p>The post <a href="https://keylaser.am/product/uv-aging-test-chamber/">UV Aging Test Chamber</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
