<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Centrifuges Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-category/scitek/centrifuges/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-category/scitek/centrifuges/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Thu, 20 Mar 2025 07:17:05 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>Centrifuges Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-category/scitek/centrifuges/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Benchtop High Speed Refrigerated Centrifuge CFG-T21HR</title>
		<link>https://keylaser.am/product/benchtop-high-speed-refrigerated-centrifuge-cfg-t21hr/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 20 Mar 2025 07:17:05 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=13421</guid>

					<description><![CDATA[<div class="pro-this-prodBrief"><strong>Model : CFG-T21HR</strong></p>
<p>Max Speed (rpm) : 21000<br />
Max RCF (xg) : 31600<br />
Temperature Setting (℃) : -20～+40<br />
Timer : 0~99h 59min 59s<br />
Max Capacity : 500mL×4</p></div>
<p>The post <a href="https://keylaser.am/product/benchtop-high-speed-refrigerated-centrifuge-cfg-t21hr/">Benchtop High Speed Refrigerated Centrifuge CFG-T21HR</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2><strong>Refrigerated Centrifuge Features:</strong></h2>
<ol class=" list-paddingleft-2">
<li>5-inch HD touch screen: Easy and intuitive operation.</li>
<li>Automatic rotor identification: Ensures user safety.</li>
<li>Adjustable acceleration and deceleration: Prevents sample disturbance.</li>
<li>Programmable storage: Convenient access to frequently used settings.</li>
<li>AC frequency conversion motor: Precise speed control.</li>
<li>Multiple safety features: Protects both users and equipment.</li>
<li>Speed and RCF switching: Flexible operation.</li>
<li>Special air duct design: Maintains optimal rotor temperature.</li>
<li>Airtight rotor: Prevents aerosol contamination.</li>
</ol>
<p>&nbsp;</p>
<h2><strong>Refrigerated Centrifuge Specifications:</strong></h2>
<p>&nbsp;</p>
<p>&nbsp;</p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="599">
<thead>
<tr class="firstRow">
<th>Model</th>
<th width="303.3333333333333">CFG-T21HR</th>
</tr>
</thead>
<tbody>
<tr>
<td>Max. Speed</td>
<td width="303.3333333333333">21000r/min</td>
</tr>
<tr>
<td>Max. RCF</td>
<td width="303.3333333333333">31600×g</td>
</tr>
<tr>
<td>Max.Capacity</td>
<td width="303.3333333333333">500mL×4</td>
</tr>
<tr>
<td>Speed Accuracy</td>
<td width="303.3333333333333">±20r/min</td>
</tr>
<tr>
<td>Time Setting</td>
<td width="303.3333333333333">0～99h59min59s</td>
</tr>
<tr>
<td>Temperature Control Range</td>
<td width="303.3333333333333">-20℃～40℃</td>
</tr>
<tr>
<td>Temperature Control Accuracy</td>
<td width="303.3333333333333">±1℃</td>
</tr>
<tr>
<td>Compressor</td>
<td width="303.3333333333333">Imported high-performance compressor unit, fluorine-free refrigerant</td>
</tr>
<tr>
<td>Electricity</td>
<td width="303.3333333333333">AC 220V 50Hz 15A</td>
</tr>
<tr>
<td>Sizes(W×D×H)(mm)</td>
<td width="303.3333333333333">743x720x410</td>
</tr>
<tr>
<td>Packaging Weight (W×D×H)(mm)</td>
<td width="303.3333333333333">825x810x570</td>
</tr>
<tr>
<td>N.W./G.W. (kg)</td>
<td width="303.3333333333333">110/130</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>Scitek Global is a leading supplier of laboratory and medical equipment for scientific research, healthcare, and educational institutions. With a focus on quality and reliability, we provide a wide range of products, from microscopes and centrifuges to ultrasound machines and surgical instruments.</p>
<p>Our team of experienced professionals is dedicated to providing exceptional customer service and technical support, ensuring that our customers have the tools and resources they need to achieve their goals.</p>
<p>&nbsp;</p>
<h2><strong>Our Services:</strong></h2>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Packing &amp; Delivery</strong></p>
<p>Adopting standard international export packaging, the packaging can adapt to long-term international transportation.</p>
<p>We provide sea freight, air freight, land freight, express service, accept EXW, FCA, FAS, FOB, CFR, CIF, CPT, CIP, DAF, DES, DEQ, DDU, DDP and other trade terms.</p>
<p><strong>Pre-sale services</strong></p>
<p>●24-hour quick response to customer inquiries.</p>
<p>●Recommend models that meet customer requirements.<br />
●Provide competitive prices and detailed product parameters and related information.<br />
●Provide product customization services.<br />
●Sample testing support, production view service.</p>
<p><strong>After-sales service</strong></p>
<p>●Product installation and use training.</p>
<p>●Provide overseas maintenance services in response to customers technical problems.<br />
●Three-year warranty on air protection products, life time maintenance service.<br />
●Online and offline technical personnel training services.</p>
<p>The post <a href="https://keylaser.am/product/benchtop-high-speed-refrigerated-centrifuge-cfg-t21hr/">Benchtop High Speed Refrigerated Centrifuge CFG-T21HR</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Benchtop Low Speed Centrifuge, CFG-T5L</title>
		<link>https://keylaser.am/product/benchtop-low-speed-centrifuge-cfg-t5l/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 20 Mar 2025 07:14:38 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=13406</guid>

					<description><![CDATA[<div><strong>Model : CFG-T5L</strong></p>
<p>Max Speed : 5500rmp/m<br />
Max RCF : 4390×g<br />
Max Capacity : 4×500mL<br />
External Size (W×D×H)(mm) : 458×620×380</p></div>
<div>This low-speed centrifuge is designed to meet the needs of medium-throughput clinical research and cell culture laboratories.</div>
<p>The post <a href="https://keylaser.am/product/benchtop-low-speed-centrifuge-cfg-t5l/">Benchtop Low Speed Centrifuge, CFG-T5L</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div><strong style="font-size: 1.7em;">Benchtop Low Speed Centrifuge Specifications:</strong></div>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<thead>
<tr class="firstRow">
<th>Model</th>
<th>CFG-T5L</th>
</tr>
</thead>
<tbody>
<tr>
<td>Max Speed</td>
<td>5500rmp/m</td>
</tr>
<tr>
<td>Max RCF</td>
<td>4390×g</td>
</tr>
<tr>
<td>Max Capacity</td>
<td>4×500mL</td>
</tr>
<tr>
<td>Motor</td>
<td>AC frequency conversion motor</td>
</tr>
<tr>
<td>Speed Accuracy</td>
<td>±30r/min</td>
</tr>
<tr>
<td>Time Range</td>
<td>Time of centrifuge：1min～99 min59sec<br />
Continuous centrifuge : Hold</td>
</tr>
<tr>
<td>Power Supply</td>
<td>AC220±22V 50/60Hz 10A</td>
</tr>
<tr>
<td>Noise</td>
<td>&lt;65dB(A)</td>
</tr>
<tr>
<td>External Size (W×D×H)</td>
<td>458×620×380mm</td>
</tr>
<tr>
<td>Shipping Size (W×D×H)</td>
<td>550×800×570mm</td>
</tr>
<tr>
<td>N.W/G.W</td>
<td>55kg/72kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p><strong>Rotors for CFG-T5L:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index1">
<div class="inner">
<table>
<thead>
<tr class="firstRow">
<th width="">Number</th>
<th width="">Rotor Type</th>
<th width="">Capacity</th>
<th width="">Max speed rmp/m</th>
<th width="">Max RCF(xg)</th>
<th width="">Dimension of Tube (mm)</th>
</tr>
</thead>
<tbody>
<tr>
<td colspan="1" rowspan="7" width="122">NO.1</td>
<td colspan="1" rowspan="7" width="122">Swing Rotor</td>
<td width="122">4x2x100ml</td>
<td width="122">4000rmp/m</td>
<td width="122">2810×g</td>
<td width="122">
Φ37.5×123</td>
</tr>
<tr>
<td width="122">4x100ml</td>
<td width="122">4000rmp/m</td>
<td width="122">2810×g</td>
<td width="122">
Φ37.5×123</td>
</tr>
<tr>
<td width="122">4x2x50ml</td>
<td width="122">4000rmp/m</td>
<td width="122">2810×g</td>
<td width="122">Φ29×107</td>
</tr>
<tr>
<td width="122">4x50ml</td>
<td width="122">4000rmp/m</td>
<td width="122">2810×g</td>
<td width="122">Φ29×107</td>
</tr>
<tr>
<td width="122">4x8x15ml</td>
<td colspan="1" rowspan="3" width="122">4000rmp/m</td>
<td colspan="1" rowspan="3" width="122">2810×g</td>
<td width="122">Φ17×118</td>
</tr>
<tr>
<td width="122">4x6x15ml</td>
<td width="122">Φ17×118</td>
</tr>
<tr>
<td width="122">4x4x15ml</td>
<td width="122">Φ17×118</td>
</tr>
<tr>
<td width="122">NO.2</td>
<td width="122">Swing Rotor</td>
<td width="122">4x250ml</td>
<td width="122">4200r/min</td>
<td width="122">3500xg</td>
<td width="122">Φ62×110</td>
</tr>
<tr>
<td width="122">NO.3</td>
<td width="122">Swing Rotor</td>
<td width="122">4×500ml</td>
<td width="122">4000r/min</td>
<td width="122">3040×g</td>
<td width="122">Φ80×137</td>
</tr>
<tr>
<td width="122">NO.4</td>
<td width="122">Swing Rotor</td>
<td width="122">4×12×7/5ml</td>
<td width="122">4000r/min</td>
<td width="122">2800×g</td>
<td width="122">Φ13×110</td>
</tr>
<tr>
<td width="122">NO.5</td>
<td width="122">Swing Rotor</td>
<td width="122">4×18×7/5ml</td>
<td width="122">4000r/min</td>
<td width="122">2800×g</td>
<td width="122">Φ13×110</td>
</tr>
<tr>
<td width="122">NO.6</td>
<td width="122">Swing Rotor</td>
<td width="122">4×24×7/5ml</td>
<td width="122">4000r/min</td>
<td width="122">2800×g</td>
<td width="122">Φ13×110</td>
</tr>
<tr>
<td width="122">NO.7</td>
<td width="122">Microplate Rotor</td>
<td width="122">2×2×96well</td>
<td width="122">4000r/min</td>
<td width="122">2000×g</td>
<td width="122">Microplate</td>
</tr>
<tr>
<td width="122">NO.8</td>
<td width="122">Angle Rotor</td>
<td width="122">12×10ml</td>
<td width="122">5500r/min</td>
<td width="122">4390×g</td>
<td width="122">Φ16×83</td>
</tr>
</tbody>
</table>
</div>
<figure id="attachment_13418" aria-describedby="caption-attachment-13418" style="width: 269px" class="wp-caption alignnone"><img fetchpriority="high" decoding="async" class="wp-image-13418 size-full" src="https://keylaser.am/wp-content/uploads/2025/03/Rotors-for-centrifuge.webp" alt="Benchtop Low Speed Centrifuge, CFG-T5L" width="269" height="262" /><figcaption id="caption-attachment-13418" class="wp-caption-text"><strong>4x2x100ml Swing rotor</strong></figcaption></figure>
<figure id="attachment_13417" aria-describedby="caption-attachment-13417" style="width: 251px" class="wp-caption alignnone"><img decoding="async" class="size-full wp-image-13417" src="https://keylaser.am/wp-content/uploads/2025/03/Rotors-for-centrifuge-1.webp" alt="Benchtop Low Speed Centrifuge, CFG-T5L" width="251" height="206" /><figcaption id="caption-attachment-13417" class="wp-caption-text"><strong>4x500ml Swing rotor</strong></figcaption></figure>
</div>
<h2><strong>Benchtop Low Speed Centrifuge Feature:</strong></h2>
<p>&nbsp;</p>
<ol class=" list-paddingleft-2">
<li>5-inch high-definition touch screen, easily operated, visual display.</li>
<li>Automatically identify 4 kinds of different rotors, eliminate hidden danger brought by users&#8217; maloperation.</li>
<li>9 ranges for raising speed, 10 ranges for speed reduction, to effectively avoid secondary sedimentation, with better centrifugation effect.</li>
<li>Available to store 15 series of procedure for users to adjust.</li>
<li>The benchtop low speed centrifuge of a special duct allows it to work continuously under a room temperature of 26-28oC, with temperature rise less than 15°C.</li>
<li>Alternating frequency conversion electric machine, high precision of rotary speed control.</li>
<li>The unique secondary damping device enables it to operate with very low vibration when the high-capacity rotor is working. The design maintains stable operations and is conducive to a longer service life of the instrument.</li>
<li>Diverse protection setting: over-speed, door protect, imbalance protect, to ensure safety of both human and machine.</li>
</ol>
</div>
<p>The post <a href="https://keylaser.am/product/benchtop-low-speed-centrifuge-cfg-t5l/">Benchtop Low Speed Centrifuge, CFG-T5L</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		