<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Chromatography Systems Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-category/scitek/chromatography-systems/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-category/scitek/chromatography-systems/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Fri, 21 Mar 2025 14:14:49 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>Chromatography Systems Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-category/scitek/chromatography-systems/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Gas Chromatograph, 22L</title>
		<link>https://keylaser.am/product/gas-chromatograph-22l/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 21 Mar 2025 14:14:49 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=13793</guid>

					<description><![CDATA[<p><strong>Model : GC-112</strong></p>
<p>Carrier Gas Flow Control Type : Constant pressure</p>
<div><span style="font-family: Arial, Helvetica, sans-serif;">Temp Control Type : Independent</span></div>
<div><span style="font-family: Arial, Helvetica, sans-serif;">Type Packed : Column or split</span></p>
<div>Flow Setting Range : H20~200ml/min, N20~150ml/min</div>
</div>
<p>The post <a href="https://keylaser.am/product/gas-chromatograph-22l/">Gas Chromatograph, 22L</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2><strong>Gas Chromatograph Specifications:</strong></h2>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="646">
<thead>
<tr class="firstRow">
<th colspan="2">Model</th>
<th width="288">GC-112</th>
</tr>
</thead>
<tbody>
<tr>
<td rowspan="7" width="5">Oven</td>
<td width="65.33333333333333">Capacity</td>
<td width="241.33333333333334">22L</td>
</tr>
<tr>
<td width="163">Temperature Range</td>
<td width="200.33333333333331">RT+5℃-400℃</td>
</tr>
<tr>
<td width="165">Temperature Accuracy</td>
<td width="203.33333333333331">±0.1 ℃</td>
</tr>
<tr>
<td width="167">Temperature Programming</td>
<td width="205.33333333333331">9 steps</td>
</tr>
<tr>
<td width="168">Program Total Time</td>
<td width="205.33333333333331">9999.9 min</td>
</tr>
<tr>
<td width="168">Max Heating Rate</td>
<td width="205.33333333333331">60℃/min</td>
</tr>
<tr>
<td width="168">Max Cooling Rate</td>
<td width="205.33333333333331">≦10mins (250℃~50℃)</td>
</tr>
<tr>
<td rowspan="9" width="5">Sample Injector</td>
<td width="65.33333333333333">Temperature range</td>
<td width="247.33333333333334">RT+7℃~ 420 ℃</td>
</tr>
<tr>
<td width="168">Temp Control Type</td>
<td width="205.33333333333331">Independent</td>
</tr>
<tr>
<td width="168">Carrier Gas Flow Control Type</td>
<td width="205.33333333333331">Constant pressure</td>
</tr>
<tr>
<td width="168">Max Quantity</td>
<td width="205.33333333333331">3pcs</td>
</tr>
<tr>
<td width="168">Type</td>
<td width="205.33333333333331">Packed column or split</td>
</tr>
<tr>
<td width="168">Split Ratio</td>
<td width="205.33333333333331">Display</td>
</tr>
<tr>
<td width="168">Pre Column Pressure Range</td>
<td width="205.33333333333331">0-400kpa</td>
</tr>
<tr>
<td width="168">Pre Column Pressure Accuracy</td>
<td width="205.33333333333331">0.1kpa</td>
</tr>
<tr>
<td width="168">Flow Setting Range</td>
<td width="205.33333333333331">H20~200ml/min,<br />
N20~150ml/min</td>
</tr>
<tr>
<td rowspan="16">Detector</td>
<td colspan="2" width="538">FID or TCD</td>
</tr>
<tr>
<td width="168">Temperature Range</td>
<td width="205.33333333333331">RT+7℃~ 420 ℃</td>
</tr>
<tr>
<td width="168">Max Installation Qty</td>
<td width="205.33333333333331">2</td>
</tr>
<tr>
<td width="168">Ignition Mode</td>
<td width="205.33333333333331">Automatic</td>
</tr>
<tr>
<td rowspan="8" width="168">Hydrogen Flame Ionization Detector (FID)</td>
<td width="205.33333333333331">Logarithmic amplifier</td>
</tr>
<tr>
<td width="289">High Voltage Switch Control</td>
</tr>
<tr>
<td width="289">Baseline signal display</td>
</tr>
<tr>
<td width="289">Detection limit: ≦3×10<sup>-12</sup> g/s ( sample: n-hexadecane)</td>
</tr>
<tr>
<td width="289">Baseline noise: ≦5×10<sup>-14</sup>A</td>
</tr>
<tr>
<td width="289">Baseline draft: ≦6×10<sup>-13</sup>A</td>
</tr>
<tr>
<td width="289">Dynamic range: 10<sup>7</sup></td>
</tr>
<tr>
<td width="289">RSD: ≦3%</td>
</tr>
<tr>
<td rowspan="4" width="168">Thermal Conductivity Detector (TCD)</td>
<td width="205.33333333333331">Sencitivity: 8000mV.ml/mg (sample: n-hexadecane)</td>
</tr>
<tr>
<td width="289">Baseline noise: ≦0.05mV</td>
</tr>
<tr>
<td width="289">Baseline draft: ≦0.15mV/ 30min</td>
</tr>
<tr>
<td width="289">Dynamic range: 10<sup>5</sup></td>
</tr>
<tr>
<td rowspan="4" width="5">Basic Function</td>
<td width="65.33333333333333">Power Supply</td>
<td width="250.33333333333334">AC220V±10%, 50Hz</td>
</tr>
<tr>
<td width="168">Power</td>
<td width="205.33333333333331">3000W</td>
</tr>
<tr>
<td width="168">Shipping Size(W×D×H)(mm)</td>
<td width="205.33333333333331">760X750X860</td>
</tr>
<tr>
<td width="168">N.W./G.W. (kg)</td>
<td width="205.33333333333331">64/86</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>&nbsp;</p>
<h2><strong>Gas Chromatograph Feature:</strong></h2>
<ol class=" list-paddingleft-2">
<li>An intuitive 7-inch color touch screen providing digital displays for carrier/hydrogen/air channel flow (pressure) for easy monitoring.</li>
<li>It has gas shortage alarm protection and heating control safeguards to ensure operational safety. The system automatically shuts down the column box fan motor and heating when the door is opened.</li>
<li>Automatic control of split flow/split ratio optimizes carrier gas usage, reducing waste.</li>
<li>It is tailored for various automatic samplers, with an installation and positioning interface for effortless compatibility.</li>
<li>The gas chromatograph operates on a robust multi-core, 32-bit embedded hardware system, ensuring reliable and stable performance.</li>
<li>It features a convenient one-button start function and 20 groups of sample test mode memory, enhancing operational efficiency and ease of use.</li>
<li>Utilizes a logarithmic amplifier, ensuring a continuous detection signal with excellent peak shape. The system supports an external trigger function for synchronous start, activated by external signals like automatic samplers or thermal analyzers.</li>
<li>Incorporates a comprehensive system self-check and automatic fault identification function, ensuring operational reliability.</li>
<li>Offers 8 external event extension function interfaces, allowing customization with various control valves and sequence operations per user-defined time frames.</li>
<li>It comes equipped with RS232 communication and LAM network ports, along with a configuration option for a data acquisition card, ensuring versatile connectivity and data acquisition capabilities.</li>
</ol>
<p>The post <a href="https://keylaser.am/product/gas-chromatograph-22l/">Gas Chromatograph, 22L</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Gas Chromatograph GC-102</title>
		<link>https://keylaser.am/product/gas-chromatograph-gc-102/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 21 Mar 2025 14:13:06 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=13790</guid>

					<description><![CDATA[<p><strong>Model : GC-102</strong></p>
<p>Temperature Area : Column oven, sampler, detector</p>
<div>Temperature Range : 15℃~399℃above room temperature (increment: 1℃)</div>
<div>Our Gas Chromatograph features rugged construction, thermal insulation, and multi-phase temperature programming for accurate and reliable analysis.</div>
<p>The post <a href="https://keylaser.am/product/gas-chromatograph-gc-102/">Gas Chromatograph GC-102</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2><strong>Gas Chromatograph Feature:</strong></h2>
<ol class=" list-paddingleft-2">
<li>The advanced gas chromatography system showcases several impressive features, carefully designed for precision and ease of use.</li>
<li>With seamless PC control, the user interface is user-friendly and easy to navigate and operate.</li>
<li>Temperature regulation is precise, with an accuracy greater than ±0.1°C, minimizing temperature overshoot during rapid heating.</li>
<li>A built-in self-diagnostic system ensures continuous monitoring and protection, including power protection, oven over-temperature protection and auto-ignition for increased safety and reliability.</li>
<li>Accurate display of temperature setting and actual value and FID amplifier sensitivity</li>
<li>Single gas system and precision graduated pneumatic control valves ensure excellent reproducibility and stability.</li>
</ol>
<h2><strong>Gas Chromatograph Specifications:</strong></h2>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="632">
<thead>
<tr class="firstRow">
<th colspan="2">Model</th>
<th width="270.3333333333333">GC-102</th>
</tr>
</thead>
<tbody>
<tr>
<td rowspan="3" width="97.99999999999997">Temperature Control</td>
<td width="200.33333333333334">Temperature Area</td>
<td>Column oven, sampler, detector</td>
</tr>
<tr>
<td width="74.99999999999997">Temperature Range</td>
<td width="233.33333333333334">15℃~399℃ above room temperature (increment: 1℃)</td>
</tr>
<tr>
<td width="74.99999999999997">Temperature Accuracy</td>
<td width="233.33333333333334">Better than ±0.1℃(measured at 200℃)</td>
</tr>
<tr>
<td rowspan="4" width="97.99999999999997">Flame Ionization Detector (FID)</td>
<td width="200.33333333333334">Detection Limit</td>
<td>Dt ≤1×10<sup>-10</sup>g/s (octane and hexadecane)</td>
</tr>
<tr>
<td width="74.99999999999997">Baseline Drift</td>
<td width="233.33333333333334">≤2×10<sup>-12</sup>A/h</td>
</tr>
<tr>
<td width="74.99999999999997">Linear Range</td>
<td width="233.33333333333334">≥10</td>
</tr>
<tr>
<td width="74.99999999999997">Max. limit Temperature</td>
<td width="233.33333333333334">400℃</td>
</tr>
<tr>
<td rowspan="5" width="97.99999999999997">Basic Function</td>
<td width="200.33333333333334">Power Supply</td>
<td>AC220V±10%, 50Hz</td>
</tr>
<tr>
<td width="74.99999999999997">Power</td>
<td width="233.33333333333334">≤1500W</td>
</tr>
<tr>
<td width="74.99999999999997">Optional Accessories</td>
<td width="233.33333333333334">N2000 chromatography workstation</td>
</tr>
<tr>
<td width="74.99999999999997">Shipping Size(W×D×H)(mm)</td>
<td width="233.33333333333334">970×680×780</td>
</tr>
<tr>
<td width="74.99999999999997">N.W./G.W. (kg)</td>
<td width="233.33333333333334">56/80</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/gas-chromatograph-gc-102/">Gas Chromatograph GC-102</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>