<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Air Shower and Pass Box Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-tag/air-shower-and-pass-box/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-tag/air-shower-and-pass-box/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Wed, 09 Oct 2024 13:02:31 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>Air Shower and Pass Box Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-tag/air-shower-and-pass-box/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Pathology Workstation</title>
		<link>https://keylaser.am/product/pathology-workstation/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 09 Oct 2024 13:02:30 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=10974</guid>

					<description><![CDATA[<p><strong>Introduction:</strong><br />
Pathological materials bench is designed according to the characteristics of China's environmental and equipped with high quality parts, careful processing, reliable quality, elegant appearance, fully functional. It is the best choice for hospital, pathology laboratory.</p>
<p>The post <a href="https://keylaser.am/product/pathology-workstation/">Pathology Workstation</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>QCT-1000, QCT-1500, QCT-1800</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Application:</strong></p>
<p>Pathological sampling bench is widely used in hospital pathology department, pathology laboratory, etc.</p>
<p>Reasonable ventilation system protects operator away from the harmful gas produced by the formalin during sampling. The hot&amp;cold water system ensures it can adapt work in different climates.</p>
<p><strong>Features:</strong><br />
1. Odor-remove function.</p>
<p>2. Single water sink, two-person operations.</p>
<p>3. Exhaust air system: High-power suction device, low noise.</p>
<p>4. Optional water heater is available, realizing hot &amp; cold water adjustment.</p>
<p>5. The base cabinet is inward-concave type, convenient for sitting operation.</p>
<p>6. Optional pulverizer can completely smash the waste during test, to avoid blocking drainage pipes.</p>
<p>7. Automatic flushing device, slightly right-side inclined worktable, easy for waste discharge and cleaning.</p>
<p><img fetchpriority="high" decoding="async" class="alignnone wp-image-10975 size-large" src="https://keylaser.am/wp-content/uploads/2024/10/QCT-1024x541.webp" alt="Pathology Workstation" width="1024" height="541" srcset="https://keylaser.am/wp-content/uploads/2024/10/QCT-1024x541.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/QCT-300x159.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/QCT-768x406.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/QCT-600x317.webp 600w, https://keylaser.am/wp-content/uploads/2024/10/QCT.webp 1033w" sizes="(max-width: 1024px) 100vw, 1024px" /></p>
<p>&nbsp;</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="886" align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td colspan="2">Model</td>
<td>QCT-1000</td>
<td>QCT-1500</td>
<td>QCT-1800</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">External Size(W*D*H)</td>
<td>1000*750*1950mm</td>
<td>1500*750*1950mm</td>
<td>1800*750*1950mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">Working Area Size(W*D*H)</td>
<td>895*430mm</td>
<td>1395*430mm</td>
<td>1695*430mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Work Surface Height</td>
<td colspan="3">850mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">Consumption</td>
<td>300W</td>
<td>300W</td>
<td>300W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Power Supply</td>
<td colspan="3">AC220V±10%, 50/60Hz; 110V±10%, 60Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">Exhaust Airflow Volume</td>
<td colspan="3">500~600m³/h</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="2">Material</td>
<td>Main Body</td>
<td colspan="3">304 stainless steel</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Work Table</td>
<td colspan="3">304 stainless steel</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Standard Accessories</td>
<td colspan="3">Built-in fan, UV lamp, spotlight, LED lighting, telescopic faucet, activated carbon filter, hot and cold taps, transparent socket, sink, side countertop flushing part</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">Optional Accessories</td>
<td colspan="3">Water heater, pulverizer, eye washer, magnetic adsorption tool, LED floor magnifying glass, sampling plate, computer stand, stainless steel paper box, camera, large object imaging system, splash guard, hand dryer, external exhaust fan</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Package Size(W*D*H)mm</td>
<td>1160*890*2170</td>
<td>1660*890*2170</td>
<td>1960*890*2170</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">Gross Weight</td>
<td>250kg</td>
<td>300kg</td>
<td>340kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/pathology-workstation/">Pathology Workstation</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Pass Box</title>
		<link>https://keylaser.am/product/pass-box/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 09 Oct 2024 12:55:55 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=10962</guid>

					<description><![CDATA[<p><strong>Introduction:</strong><br />
Pass Box is used to transfer goods between rooms of different clean levels of clean room. It can reduce times of opening door, prevent the air convection between different rooms and minimize the pollution extent.</p>
<p>The post <a href="https://keylaser.am/product/pass-box/">Pass Box</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>ASPB-01 ASPB-02 ASPB-03 PB-01 PB-02 PB-03</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="899" align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Type</td>
<td colspan="3">Air Shower Pass Box</td>
<td colspan="3">Pass Box</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Model</td>
<td>ASPB-01</td>
<td>ASPB-02</td>
<td>ASPB-03</td>
<td>PB-01</td>
<td>PB-02</td>
<td>PB-03</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>External Size(W*D*H)mm</td>
<td>660*570*1000</td>
<td>760*670*1100</td>
<td>860*770*1200</td>
<td>660*570*580</td>
<td>760*670*680</td>
<td>860*770*780</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Internal Size(W*D*H)mm</td>
<td>500*500*500</td>
<td>600*600*600</td>
<td>700*700*700</td>
<td>500*500*500</td>
<td>600*600*600</td>
<td>700*700*700</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Material</td>
<td colspan="6">304 stainless steel</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Interlock</td>
<td colspan="6">Electronical</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>UV Lamp</td>
<td colspan="6">8W*1</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>HEPA Filter</td>
<td colspan="3">Efficiency≥99.995% at 0.3μm</td>
<td colspan="3">/</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Clean Air Speed</td>
<td colspan="3">0.36~0.54m/s</td>
<td colspan="3">/</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power Supply</td>
<td colspan="6">220V, 50Hz; 110V, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight(Kg)</td>
<td>80</td>
<td>100</td>
<td>120</td>
<td>55</td>
<td>70</td>
<td>90</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Packing Size(W*D*H)mm</td>
<td>780*700*1250</td>
<td>880*800*1350</td>
<td>980*900*1450</td>
<td>780*700*770</td>
<td>880*800*870</td>
<td>980*900*970</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/pass-box/">Pass Box</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Pass Box MPB-400</title>
		<link>https://keylaser.am/product/pass-box-mpb-400/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 09 Oct 2024 12:53:10 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=10958</guid>

					<description><![CDATA[<p>Introduction:<br />
Pass Box is used to transfer goods between rooms of different clean levels of clean room. It can reduce times of opening door, prevent the air convection between different rooms and minimize the pollution extent.</p>
<p>The post <a href="https://keylaser.am/product/pass-box-mpb-400/">Pass Box MPB-400</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>MPB-400</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="899">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td width="247">Model</td>
<td width="626">MPB-400</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="247">External Size(W*D*H)mm</td>
<td width="626">520*460*480</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="247">Internal Size(W*D*H)mm</td>
<td width="626">400*400*400</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="247">Material</td>
<td width="626">304 Stainless Steel</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="247">Interlock</td>
<td width="626">Mechanical</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="247">UV Lamp</td>
<td width="626">T5, 8W</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="247">Power Supply</td>
<td width="626">220V, 50Hz</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="247">Gross Weight(Kg)</td>
<td width="626">17</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="247">Package Size(W*D*H)mm</td>
<td width="626">580*530*830</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/pass-box-mpb-400/">Pass Box MPB-400</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Air Shower</title>
		<link>https://keylaser.am/product/air-shower/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 09 Oct 2024 12:50:58 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=10952</guid>

					<description><![CDATA[<p><strong>Introduction:</strong><br />
Air shower is ideal supporting equipment for biological clean rooms and clean workshops. They are widely used for blowing off humans' and their belongings' surface dusts in micro-electronics, hospitals, pharmaceuticals, biochemical, food safety, fine chemical engineering, fine mechanics, productive facilities and scientific and research institutes, such as aviation and aerospace. Meanwhile, air showers also work as an air brake to prevent unpurified air from entering clean space. In one word, it is an effective equipment for cleansing humans and anti-air pollution in clean space.</p>
<p>The post <a href="https://keylaser.am/product/air-shower/">Air Shower</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>AS-1P1S AS-1P2S AS-2P2S</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
<p><strong>Features:</strong></p>
<p>1. Photoelectric sensor, automatic blowing.<br />
2. Adopt with circulation wind to ensure the cleanness of shower area under non-shower status.<br />
3. Double doors by electric interlock.<br />
4. LED display with adjustable blowing time(0~99s).<br />
5. HEPA filter, Class 100 cleanness.</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>AS-1P1S</td>
<td>AS-1P2S</td>
<td>AS-2P2S</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size(W*D*H)</td>
<td>1300*1000*2050mm</td>
<td>1500*1000*2050mm</td>
<td>1500*2000*2050mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Shower Area Size(W*D*H)</td>
<td>800*900*1930mm</td>
<td>800*900*1930mm</td>
<td>800*1900*1930mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>HEPA Filter</td>
<td colspan="3">99.995% efficiency at 0.3μm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Spraying Wind Speed</td>
<td colspan="3">25m/s</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Air Shower Time</td>
<td colspan="3">0~99s(adjustable)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>No.of SS Nozzles</td>
<td>6</td>
<td>12</td>
<td>24</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Fluorescent Lamp</td>
<td>12W*1</td>
<td>12W*1</td>
<td>12W*1</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Consumption</td>
<td>550W</td>
<td>1100W</td>
<td>2200W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Cabinet Material(Optional)</td>
<td colspan="3">1. Full cold-rolled steel with powder coating.</p>
<p>2. Internal stainless steel, external with cold-rolled steel.</p>
<p>3. Full stainless steel.</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Door Material(Optional)</td>
<td colspan="3">1. Cold-rolled steel with powder coating.</p>
<p>2. Stainless steel.</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Chassis</td>
<td colspan="3">Stainless steel</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Power Supply</td>
<td colspan="3">AC220V±10%, 50/60Hz; 110V±10%, 60Hz</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Gross Weight</td>
<td>300kg</td>
<td>400kg</td>
<td>700kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Package Size(W*D*H)mm</td>
<td>1400*1200*2200</td>
<td>1600*1200*2200</td>
<td>1600*2200*2200</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/air-shower/">Air Shower</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
