<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Auto Hematology Analyzer Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-tag/auto-hematology-analyzer/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-tag/auto-hematology-analyzer/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Wed, 18 Mar 2026 17:56:25 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>Auto Hematology Analyzer Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-tag/auto-hematology-analyzer/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>3-Part Auto Hematology Analyzer Reagent</title>
		<link>https://keylaser.am/product/3-part-auto-hematology-analyzer-reagent/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 18 Mar 2026 17:56:25 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14792</guid>

					<description><![CDATA[<p><label>Model: </label>SFL SFL-1 10×SFL-1 SFL-DM (Veterinary) SFL-TK (Veterinary) Probe Cleaning Fluid II E-Z Cleaning Fluid</p>
<p>Lyse SFL、SFL-DM、SFL-TK: used to destroy red blood cells, dissolve hemoglobin, and maintain the required morphology of analyzed cells before blood cell analysis, so as to facilitate cell classification and counting or hemoglobin quantitative determination.</p>
<p>The post <a href="https://keylaser.am/product/3-part-auto-hematology-analyzer-reagent/">3-Part Auto Hematology Analyzer Reagent</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Introduction:</strong></p>
<p>Lyse SFL/SFL-DM/SFL-TK: used to destroy red blood cells, dissolve hemoglobin, and maintain the required morphology of analyzed cells before blood cell analysis, so as to facilitate cell classification and counting or hemoglobin quantitative determination.</p>
<p>Diluent SFL-1: used to dilute samples and prepare cell suspensions before blood cell analysis.</p>
<p>Diluent 10×SFL-1: used to dilute samples and prepare cell suspensions before blood cell analysis. Concentrated version of diluent SFL-1: which needs to be diluted before use.</p>
<p>Probe Cleaning Fluid II: used to cleaning the instrument regularly.</p>
<p>E-Z Cleaning Fluid: used to clean and rinse the injector, valve and piping system. Cleaning the instrument regularly.</p>
<p><strong>Features:</strong></p>
<p>1. It is highly versatile and can be used in various types of three-classification blood cell analyzers.</p>
<p>2. It has high stability. The reagent should be stored indoors away from light at a temperature of 8~30°C. The validity period is 24 months(SFL-DM, SFL-TK is 18 months). The validity period after opening the bottle is 60 days.</p>
<p>3. It has high safety, cyanide-free formula, non-toxic and harmless, and protects the environment.</p>
<p>4. SFL is applicable to 3-Part Hematology Analyzer BH-HA310.</p>
<p>5. SFL-DM is applicable to 3-Part Hematology Analyzer BH-HA310VET.</p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>SFL</td>
<td>SFL-1</td>
<td>10×SFL-1</td>
<td>SFL-DM(Veterinary)</td>
<td>SFL-TK(Veterinary)</td>
<td>Probe</p>
<p>Cleaning Fluid II</td>
<td>E-Z Cleaning Fluid</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Specification</td>
<td>1l, 500ml, 300ml, 250ml, 200ml, 120ml</td>
<td colspan="2">1l, 2l, 3l, 5l, 10l, 18l, 20l</td>
<td colspan="2">1l, 500ml, 300ml, 250ml, 200ml, 120ml</td>
<td colspan="2">50ml, 100ml</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Component</td>
<td>Na2HPO4, KH2PO4, Hexadecyltrimethylammonium bromide, Triton X-100, NaNO2, BSA</td>
<td colspan="2">NaCl, Na2HPO4, KH2PO4, KCl,</p>
<p>Ethylenediaminetetraacetic acid disodium salt, Ethelene glycol monophenyl ether</td>
<td>Citric acid,</p>
<p>Hexadecyltrimethylammonium bromide, Triton X-100, BSA</td>
<td>Na2HPO4, KH2PO4, Hexadecyltrimethylammonium bromide, Triton X-100, BSA</td>
<td>Surfactants, Trisodium citrate dihydrate,Na2HPO4，NaH2PO4</td>
<td>Surfactants, Antibacterial agents, Proteolytic enzymes, etc</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/3-part-auto-hematology-analyzer-reagent/">3-Part Auto Hematology Analyzer Reagent</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>5-Part Auto Hematology Analyzer Reagent</title>
		<link>https://keylaser.am/product/5-part-auto-hematology-analyzer-reagent/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 18 Mar 2026 17:51:40 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14783</guid>

					<description><![CDATA[<p>Reagents used in conjunction with the 5-part hematology analyzer.</p>
<p>The post <a href="https://keylaser.am/product/5-part-auto-hematology-analyzer-reagent/">5-Part Auto Hematology Analyzer Reagent</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Introduction:</strong></p>
<p>Lyse WFL-LH: used to destroy red blood cells, dissolve hemoglobin, and maintain the morphology of the cells to be analyzed before blood cell analysis, so as to facilitate cell classification and counting or hemoglobin quantitative determination.</p>
<p>Lyse WFL-LD: used to maintain cell morphology and perform white.</p>
<p>Diluent WFL-2: used to dilute samples and prepare cell suspensions before blood cell analysis.</p>
<p>Diluent 10×WFL-2: used to dilute samples and prepare cell suspensions before blood cell analysis. Concentrated version of diluent WFL-2, which needs to be diluted before use.</p>
<p>Probe Cleaning Fluid II: used to cleaning the instrument regularly.</p>
<p>E-Z Cleaning Fluid: used to clean and rinse the injector, valve and piping system. Cleaning the instrument regularly.</p>
<p><strong>Features:</strong></p>
<p>1. High accuracy, dedicated machine, benchmarked against national standard substances.</p>
<p>2. High stability, the reagent is stored indoors away from light, the temperature is 8~30℃, the validity period is 24 months, the validity period after opening the bottle is 60 days.</p>
<p>3. High safety, cyanide-free formula, non-toxic and harmless, environmental protection.</p>
<p>4. Applicable to 5-Part Auto Hematology Analyzer BK-6310, BK-6500.</p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>WFL-LH</td>
<td>WFL-LD</td>
<td>WFL-2</td>
<td>10×WFL-2</td>
<td>Probe Cleaning Fluid II</td>
<td>E-Z Cleaning Fluid</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Specification</td>
<td colspan="2">1l, 500ml, 300ml, 250ml, 200ml, 120ml</td>
<td colspan="2">1l, 2l, 3l, 5l, 10l, 18l, 20l</td>
<td colspan="2">50ml, 100ml</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Component</td>
<td>Na2HPO4, KH2PO4, NaCl, Hexadecyl trimethyl ammonium chloride, BSA</td>
<td>Na2HPO4, KH2PO4, Hexadecyl trimethyl ammonium bromide, Triton X-100, NaNO2, BSA</td>
<td colspan="2">NaCl, Na2HPO4, KH2PO4, KCl, Formaldehyde, Ethelene glycol monophenyl ether</td>
<td>Surfactants, Trisodium citrate dihydrate, Na2HPO4，NaH2PO4</td>
<td>Surfactants, Antibacterial agents, Proteolytic enzymes, etc.</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/5-part-auto-hematology-analyzer-reagent/">5-Part Auto Hematology Analyzer Reagent</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>5-Part Auto Veterinary Hematology Analyzer</title>
		<link>https://keylaser.am/product/5-part-auto-veterinary-hematology-analyzer/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 09 Mar 2026 13:22:47 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14502</guid>

					<description><![CDATA[<p><label>Model: </label>BK-6310VET</p>
<p>Our 5-Part Veterinary Hematology Analyzer represents cutting-edge technology in veterinary diagnostics, offering precise and efficient blood analysis for comprehensive veterinary care. With its advanced features and user-friendly interface, it provides veterinarians with accurate results quickly, aiding in timely diagnoses and treatment decisions.</p>
<p>The post <a href="https://keylaser.am/product/5-part-auto-veterinary-hematology-analyzer/">5-Part Auto Veterinary Hematology Analyzer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong><br />
1. Throughput 60T/H.<br />
2. 14-inch touch screen.<br />
3. Tri-angle laser scatter + flow cytometry method + impedance method for RBC and PLT counting.<br />
4. 3D holographic scattergram displays the accurate 5-part differentiation of WBC.<br />
5. Large storage capacity: 300,000 results(including histogram, scattergram, animal information).</p>
<p>&nbsp;</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="4">BK-6310VET</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Throughput</td>
<td colspan="4">60 Tests/hour</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Profile</td>
<td colspan="4">Dog, cat, horse, sheep, goat, camel, cow, more species coming soon</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Assay Items</td>
<td colspan="4">5 parts, 29 parameters, 3 histograms, 3D scattergram</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Principle</td>
<td colspan="4">Tri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Test Mode</td>
<td colspan="4">CBC mode, CBC+DIFF mode</p>
<p>Venous whole blood, prediluted</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Volume</td>
<td colspan="4">CBC+DIFF mode: ≤20μl</p>
<p>CBC mode: ≤10μl</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Parameters</td>
<td colspan="4">WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS#. 4 research parameters: ALY%, ALY#, LIC%, LIC#</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="5">Performance</td>
<td>Item</td>
<td>Linearity range</td>
<td>Carry Over</td>
<td>CV</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>WBC</td>
<td>0~300*10<sup>9</sup>/L</td>
<td>≤0.5%</td>
<td>≤2.0%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>RBC</td>
<td>0~8.6*10<sup>12</sup>/L</td>
<td>≤0.5%</td>
<td>≤1.5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>HGB</td>
<td>0~260g/L</td>
<td>≤0.5%</td>
<td>≤1.5%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>PLT</td>
<td>0~3000*10<sup>9</sup>/L</td>
<td>≤1.0%</td>
<td>≤4.0%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Storage</td>
<td colspan="4">300,000 results including histograms, scattergrams and patient information</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Interface</td>
<td colspan="4">4 USB ports, 1 LAN port, Bi-direction LIS, support HL7 protocol, Internal RFID reader</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power Supply</td>
<td colspan="4">&nbsp;</p>
<p><a name="OLE_LINK1"></a></p>
<p>AC100-240V,50/60Hz, 300VA&nbsp;</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Package Size(W*D*H)</td>
<td colspan="4">575*490*690mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Gross Weight</td>
<td colspan="4">46kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Reagent Package Size</td>
<td colspan="4">330*330*330mm, 400*290*240mm, 400*290*240mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Gross Weight</td>
<td colspan="4">22kg 2kg, 2kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>&nbsp;</p>
<p>The post <a href="https://keylaser.am/product/5-part-auto-veterinary-hematology-analyzer/">5-Part Auto Veterinary Hematology Analyzer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Veterinary Auto Hematology Analyzer BH-HA310VET</title>
		<link>https://keylaser.am/product/veterinary-auto-hematology-analyzer-bh-ha310vet/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 09 Mar 2026 11:24:26 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14423</guid>

					<description><![CDATA[<p><label>Model: </label>BH-HA310VET</p>
<p>The Hematology Analyzer adopts classical resistance method to automatically count a variety of cells, also can classify simply according to the size of white blood cells, to help the lab easily achieve automation. Hematology Analyzer are perfectly in line with modern laboratory requirements in facilitation of operation as well as data management and communication functions.</p>
<p>The post <a href="https://keylaser.am/product/veterinary-auto-hematology-analyzer-bh-ha310vet/">Veterinary Auto Hematology Analyzer BH-HA310VET</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Hematology Analyzer can detect abnormalities of healthy animals, assess sick animals and monitor sick animals undergoing treatment by performing routine blood tests. It is suitable for animal experiment center, drug research center, animal and plant quarantine department, zoo, pet hospital, animal husbandry and veterinary system and other institutions.</p>
<p><strong>Features:</strong></p>
<p>1. Detection many animal species, with upgrade function.</p>
<p>2. Seven animal detection modes(cow, horse, sheep, goat, rabbit, dog, cat, camel).</p>
<p>3. Automatic detection, eliminating manual error.</p>
<p>4. Abnormal results intuitive prompt, timely and accurate screening out abnormal experimental results.</p>
<p>5. Three detection modes: venous blood, peripheral blood, pre-diluted peripheral blood.</p>
<p>6. 9. 7-inch color touch screen, data status at a glance.</p>
<p>7. One button for maintenance.</p>
<p>8. It can be turned on continuously for 24 hours.</p>
<p>9. Applying cyanide-free hemolytic agent to sample, safe and environmental protection without stimulation.</p>
<p>10. Automatic system diagnosis and maintenance, with a variety of alarm functions.</p>
<p>11. Fully enclosed reagent line, no contamination.</p>
<p>12. Excellent data management and communication function, automatically store 100,000 results.</p>
<p>13. Supporting online remote diagnosis and quality control.</p>
<p>The BH-HA310VET hematology analyzer has three detection modes of venous blood, capillary blood, prediluted blood, including 21 detection parameters:</p>
<p>MID#  GRAN#  LYM%  RBC  MCV  MCHC  RDW-CV  MPV  PCT P-LCC  WBC</p>
<p>LYM#  MID%  GRAN%  HGB  HCT  MCH  RDW-SD  PLT  PDW  P-LCR</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="9">BH-HA310VET</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Throughput</td>
<td colspan="9">60 samples/hour</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Principle</td>
<td colspan="9">Impedance for WBC differentiation, WBC/RBC/PLT count, Colorimetric method for HGB</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Channel</td>
<td colspan="9">2</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Parameters</td>
<td colspan="9">21 parameters(including MID#, GRAN#, LYM%, RBC, MCV, MCHC, RDW-CV, MPV, PCT, P-LCC, WBC, LYM#, MID%, GRAN%, HGB, HCT, MCH, RDW-SD, PLT, PDW, P-LCR)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Histograms</td>
<td colspan="9">3 histograms(including WBC, RBC, PLT)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Volume</td>
<td colspan="9">Venous blood: 10μl; Capillary blood: 10μl; Prediluted: 20μl</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Calibration</td>
<td colspan="9">Manual calibration, automatic calibration, and fresh blood calibration</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Counting Mode</td>
<td colspan="9">Venous blood, capillary blood, prediluted blood</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Printing Model</td>
<td colspan="9">Auto print, manual print</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>LIS System</td>
<td colspan="9">Supporting Bi-directional LIS</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Language</td>
<td colspan="9">Chinese, English, Spanish, French</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>QC</td>
<td colspan="9">L-J, X-B</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent</td>
<td colspan="9">Diluent 10L, Hemolytic agent 250ml(animal specific), Probe cleaner 50ml</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Date Input</td>
<td colspan="9">9.7-inch touch screen; mouse, keyboard(optional)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Output</td>
<td colspan="9">Built-in printer, supporting external printers</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Printer Paper</td>
<td colspan="9">57*30mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Interface</td>
<td colspan="9">4 USB ports, 1 network port, and 1 RS232 serial port</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Storage</td>
<td colspan="9">Automatic storage, 100,000 results with histograms(including sample information)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Information Transmission</td>
<td colspan="9">Bidirectional LIS communication, HL7 and many other transmission protocols</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Unclog</td>
<td colspan="9">Reverse high-pressure flush</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Work Temp.</td>
<td colspan="9">10~40°C</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Power Supply</td>
<td colspan="9">AC100~240V, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Relative Humidity</td>
<td colspan="9">≤80％</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Atmospheric Pressure</td>
<td colspan="9">86.0kPa~106.0kPa</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="2">Carry-Over Rate</td>
<td colspan="2">Parameter</td>
<td>WBC</td>
<td colspan="3">RBC</td>
<td colspan="2">HGB</td>
<td>PLT</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">CV</td>
<td>≤1.5%</td>
<td colspan="3">≤1.0%</td>
<td colspan="2">≤1.0%</td>
<td>≤3.0%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="2">Background</td>
<td colspan="2">WBC</td>
<td colspan="2">RBC</td>
<td colspan="3">HGB</td>
<td colspan="2">PLT</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">≤0.5*10<sup>9</sup>/L</td>
<td colspan="2">≤0.05*10<sup>12</sup>/L</td>
<td colspan="3">≤2g/L</td>
<td colspan="2">≤10*10<sup>9</sup>/L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="5">Linearity</td>
<td>Parameter</td>
<td colspan="4">Measurement Range</td>
<td colspan="4">CV</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>WBC</td>
<td colspan="4">(1~10.00)*10<sup>9</sup>/L<br />
(10.1~99.9)*10<sup>9</sup></td>
<td colspan="4">±0.5*10<sup>9</sup>/L</p>
<p>±5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>RBC</td>
<td colspan="4">(0.3~1.00)*10<sup>12</sup>/L<br />
(1.01~7.00)*10<sup>12</sup>/L</td>
<td colspan="4">±0.5*10<sup>12</sup>/L</p>
<p>±5%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>HGB</td>
<td colspan="4">(20~70)g/L<br />
(71~200.0)g/L</td>
<td colspan="4">±2.0g/L</p>
<p>±3%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>PLT</td>
<td colspan="4">(20~100)*10<sup>9</sup>/L<br />
(101~999)*10<sup>9</sup>/L</td>
<td colspan="4">±10.0*10<sup>9</sup>/L</p>
<p>±10%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="6">Precision</td>
<td>Parameter</td>
<td colspan="4">Repeatability</td>
<td colspan="4">Measurement Range</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>WBC</td>
<td colspan="4">≤ 4.0%</td>
<td colspan="4">(3.5~9.5)*10<sup>9</sup>/L</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>RBC</td>
<td colspan="4">≤ 2.0%</td>
<td colspan="4">(3.8~5.8)*10<sup>12</sup>/L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>HGB</td>
<td colspan="4">≤ 2.0%</td>
<td colspan="4">(115~175)g/L</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>PLT</td>
<td colspan="4">≤ 8.0%</td>
<td colspan="4">(125~350)*10<sup>9</sup>/L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>HCT</td>
<td colspan="4">≤3.0%</td>
<td colspan="4">35%~50%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>External Size(W*D*H)</td>
<td colspan="9">295*505*430mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size(W*D*H)</td>
<td colspan="9">Instrument: 404*564*616mm;</p>
<p>Reagent 1: 340*340*340mm;</p>
<p>Reagent 2: 200*150*100mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td colspan="9">20kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Gross Weight</td>
<td colspan="9">Instrument: 23kg; Reagent 1: 13kg; Reagent 2: 13kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/veterinary-auto-hematology-analyzer-bh-ha310vet/">Veterinary Auto Hematology Analyzer BH-HA310VET</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>5-Part Auto Hematology Analyzer BK-6500</title>
		<link>https://keylaser.am/product/5-part-auto-hematology-analyzer-bk-6500/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 09 Oct 2024 15:34:03 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11054</guid>

					<description><![CDATA[<div><strong>Introduction:</strong></div>
<p>This 5-part auto hematology analyzer is applicable for detecting the parameters of WBC, RBC, PLT, HGB, etc. (see Section 3.2. Parameters for details) in anticoagulated venous whole blood or capillary blood, as well as WBC 5-part differential analysis and WBC counting.</p>
<p>The post <a href="https://keylaser.am/product/5-part-auto-hematology-analyzer-bk-6500/">5-Part Auto Hematology Analyzer BK-6500</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BK-6500</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1. Throughput 70t/h.</p>
<p>2. 14 inch touch screen.</p>
<p>3. 50 sample positions, automatic loading, mixing and sampling</p>
<p>4. Tri-angle laser scatter + flow cytometry method + impedance method for RBC and PLT counting.</p>
<p>5. 3D holographic scattergram displays the accurate 5 part differentiation of WBC.</p>
<p>6. Large storage capacity: 100,000 results(including histogram, scattergram, patient information).</p>
<p>7. 50 Flags including MALARIA and DENGUE Flags to help analysis results</p>
<p>&nbsp;</p>
</div>
</div>
<figure id="attachment_11055" aria-describedby="caption-attachment-11055" style="width: 428px" class="wp-caption alignnone"><img fetchpriority="high" decoding="async" class="wp-image-11055 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/BK-1.webp" alt="5-Part Auto Hematology Analyzer BK-6500" width="428" height="730" srcset="https://keylaser.am/wp-content/uploads/2024/10/BK-1.webp 428w, https://keylaser.am/wp-content/uploads/2024/10/BK-1-176x300.webp 176w" sizes="(max-width: 428px) 100vw, 428px" /><figcaption id="caption-attachment-11055" class="wp-caption-text"> </figcaption></figure>
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Technical  Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="4">BK-6500</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Throughput</td>
<td colspan="4">70 tests/hour</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Assay Items</td>
<td colspan="4">5 parts, 25 parameters, 3 histograms(WBC/BASO, RBC, PLT), 3D scattergram</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Principle</td>
<td colspan="4">Tri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Test Mode</td>
<td colspan="4">CBC mode, CBC+DIFF mode</p>
<p>Venous whole blood, Capillary whole blood and Prediluted</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Sample Volume</td>
<td colspan="4">CBC+DIFF mode: ≤20μl</p>
<p>CBC mode: ≤10μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Parameters</td>
<td colspan="4">25 reportable parameters: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS#</p>
<p>6 research parameters: ALY%, ALY#, LIC%, LIC#, NRBC%, NRBC#</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="5">Performance</td>
<td>Item</td>
<td>Linearity Range</td>
<td>Carry Over</td>
<td>CV</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>WBC</td>
<td>0~300.0*10^9/L</td>
<td>≤0.5%</td>
<td>≤2.0%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>RBC</td>
<td>0~8.00*10^12/L</td>
<td>≤0.5%</td>
<td>≤1.5%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>HGB</td>
<td>0~250g/L</td>
<td>≤0.5%</td>
<td>≤1.5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>PLT</td>
<td>0~3000*10^9/L</td>
<td>≤1.0%</td>
<td>≤4.0%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Storage</td>
<td colspan="4">Up to 100,000 results including histograms, scattergrams and patient information</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Display</td>
<td colspan="4">14 inch touch screen, resolution 1366*768</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Interface</td>
<td colspan="4">4 USB ports, 1 LAN port, Bi-direction LIS, support HL7 protocol, Internal RFID reader</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Loading Position</td>
<td colspan="4">50 sample positions</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Power Supply</td>
<td colspan="4">AC100~240V, 50/60Hz; 300VA</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size(W*D*H)</td>
<td colspan="4">Main Machine: 680*580*895mm</p>
<p>Accessories: 950*500*580mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td colspan="4">Main Machine: 60kg</p>
<p>Accessories: 27.6kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Package Size</td>
<td colspan="4">330*330*330mm, 400*290*240mm, 400*290*240mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Reagent Gross Weight</td>
<td colspan="4">22kg, 2kg, 1kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/5-part-auto-hematology-analyzer-bk-6500/">5-Part Auto Hematology Analyzer BK-6500</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>5-Part Veterinary Hematology Analyzer</title>
		<link>https://keylaser.am/product/5-part-veterinary-hematology-analyzer/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 09 Oct 2024 15:27:53 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11049</guid>

					<description><![CDATA[<p>Our 5-Part Veterinary Hematology Analyzer represents cutting-edge technology in veterinary diagnostics, offering precise and efficient blood analysis for comprehensive veterinary care. With its advanced features and user-friendly interface, it provides veterinarians with accurate results quickly, aiding in timely diagnoses and treatment decisions.</p>
<p>The post <a href="https://keylaser.am/product/5-part-veterinary-hematology-analyzer/">5-Part Veterinary Hematology Analyzer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BK-6310VET</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong><br />
1. Throughput 60T/H.<br />
2. 14 inch touch screen.<br />
3. Tri-angle laser scatter + flow cytometry method + impedance method for RBC and PLT counting.<br />
4. 3D holographic scattergram displays the accurate 5 part differentiation of WBC.<br />
5. Large storage capacity:  100,000 results(including histogram, scattergram, animal information).</p>
<p><strong>Models:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="882">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td width="88">Model</td>
<td colspan="4" width="653">BK-6310VET</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="88">Throughput</td>
<td colspan="4" width="653">60 Tests/hour</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="186">Sample Profile</td>
<td colspan="4" width="653">Dog, cat, horse, sheep, goat, camel, cow, more species coming soon</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="88">Assay Items</td>
<td colspan="4" width="653">5 parts, 25 parameters, 3 histograms, 3D scattergram</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="88">Principle</td>
<td colspan="4" width="653">Tri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="88">Test Mode</td>
<td colspan="4" width="653">CBC mode, CBC+DIFF mode</p>
<p>Venous whole blood, Capillary whole blood and Prediluted</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="88">Sample Volume</td>
<td colspan="4" width="653">CBC+DIFF mode : ≤20ul</p>
<p>CBC mode : ≤10ul</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="88">Parameters</td>
<td colspan="4" width="653">WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS#</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="5" width="88">Performance</td>
<td width="5">Item</td>
<td>Linearity range</td>
<td>Carry Over</td>
<td>CV</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="88">WBC</td>
<td width="199">(0~300.0&#215;10^9)/L</td>
<td>≤0.5%</td>
<td>≤2.0%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="88">RBC</td>
<td width="199">(0~8.00&#215;10^12)/L</td>
<td>≤0.5%</td>
<td>≤1.5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="88">HGB</td>
<td width="199">(0~250)g/L</td>
<td>≤0.5%</td>
<td>≤1.5%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="88">PLT</td>
<td width="199">(0~3000&#215;10^9)/L</td>
<td>≤1.0%</td>
<td>≤4.0%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="88">Sample Volume</td>
<td colspan="4" width="653">CBC+DIFF mode≤20μl   CBC mode≤10μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="88">Storage</td>
<td colspan="4" width="653">100,000 results including histograms, scattergrams and patient information</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="88">Interface</td>
<td colspan="4" width="653">4 USB ports, 1LAN port, Bi-direction LIS, support HL7 protocol, Internal RFID reader</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="88">Power Supply</td>
<td colspan="4" width="653">AC100~240V±10% 50/60Hz; 400VA</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="88">Package Size</td>
<td colspan="4" width="653">575*490*690mm(W*D*H)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="88">Gross Weight</td>
<td colspan="4" width="653">46kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="88">Reagent Package Size</td>
<td colspan="4" width="653">330*330*330mm, 400*290*240mm, 400*290*240mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="88">Reagent Gross Weight</td>
<td colspan="4" width="653">22kg 2kg, 2kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/5-part-veterinary-hematology-analyzer/">5-Part Veterinary Hematology Analyzer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>3-part Auto Hematology Analyzer BK-3200</title>
		<link>https://keylaser.am/product/3-part-auto-hematology-analyzer-bk-3200/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 09 Oct 2024 15:25:28 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11043</guid>

					<description><![CDATA[<div><strong>Introduction:</strong></div>
<p>Hematology analyzer is a medical device used to detect and analyze the cellular components of blood, mainly including white blood cells, red blood cells, platelets and so on. It uses optical, electronic and other technologies to count, classify and observe the morphology of blood samples. Blood cell analyzer has important application value in clinical examination, disease prevention, diagnosis and treatment.</p>
<p>The post <a href="https://keylaser.am/product/3-part-auto-hematology-analyzer-bk-3200/">3-part Auto Hematology Analyzer BK-3200</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BK-3200</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features：</strong></p>
<p>1. 9.7-inch color touch LCD screen, easy to operate, display all parameters and histograms on the same screen.</p>
<p>2. Fewer samples are required for testing: whole blood≤12μl, pre-diluted≤20μl.</p>
<p>3. 60 samples/hour.</p>
<p>4. 21 parameters + 3 histograms.</p>
<p>5. It can be turned on continuously for 24 hours.</p>
<p>6. Automatically clean the sampler, counting pool and pipeline after starting up.</p>
<p>7. Built-in thermal printer, external printer can be connected.</p>
<p>8. Electrical impedance method, cyanide-free detection of HGB.</p>
<p>9. Fully intelligent blockage removal and alarm function.</p>
<p>10. Both automatic calibration and manual calibration are available.</p>
<p>11. Counting Mode: Venous, capilary, prediluted.</p>
<p>12. Support LIS system.</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="6">BK-3200</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Throughput</td>
<td colspan="6">60 samples/hour</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Principle</td>
<td colspan="6">Impedance for WBC differentiation and WBC/RBC/PLT count; Colorimetric method for HGB</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Channels</td>
<td colspan="6">2</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Parameters</td>
<td colspan="6">21 parameters(including WBC, Mid#, Lym#, Gran#, Mid%, Lym%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR, P-LCC)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Histograms</td>
<td colspan="6">3 histograms(including WBC, RBC, PLT histograms)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Volume</td>
<td colspan="6">Whole blood: 12μl, Prediluted: 20μl</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Calibration</td>
<td colspan="6">Manual, auto calibration</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Counting Modes</td>
<td colspan="6">Venous, capilary, prediluted</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Printing Model</td>
<td colspan="6">Auto print, manual print</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>LIS</td>
<td colspan="6">Support Bi-directional LIS</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Language</td>
<td colspan="6">Chinese, English, Spanish, French, Russian, Ukrainian</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Reagent</td>
<td colspan="6">Diluent 10L, Hemolytic agent 250ml, Probe cleanser: 50ml</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Data Input</td>
<td colspan="6">9.7-inch touch screen, mouse, keyboard(optional)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Output</td>
<td colspan="6">Internal printer, support external printer</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Printer Paper</td>
<td colspan="6">57*30mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Interface</td>
<td colspan="6">4 USB ports, network port, RS232 serial port</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Storage</td>
<td colspan="6">100,000 results with histogram</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Unclog</td>
<td colspan="6">High voltage burn, reverse high-pressure flush</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Work Temperature</td>
<td colspan="6">15~30°C</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Power Supply</td>
<td colspan="6">AC100~240, 50/60Hz, 150VA</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Relative Humidity</td>
<td colspan="6">30%~85%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Atmospheric Pressure</td>
<td colspan="6">70.0kPa~110.0kPa</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="2">Carry-over Rate</td>
<td>Parameter</td>
<td>WBC</td>
<td>RBC</td>
<td>HGB</td>
<td colspan="2">PLT</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>CV</td>
<td>≤1.5%</td>
<td>≤1%</td>
<td>≤1%</td>
<td colspan="2">≤3%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="2">Background</td>
<td>Parameter</td>
<td>WBC</td>
<td>RBC</td>
<td>HGB</td>
<td>HCT</td>
<td>PLT</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Background</td>
<td>≤0.3*10^9/L</td>
<td>≤0.03*10^12/L</td>
<td>≤1g/L</td>
<td>≤0.5%</td>
<td>≤10*10^9/L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="5">Linearity</td>
<td>Parameter</td>
<td colspan="2">Measurement Range</td>
<td colspan="3">CV</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>WBC</td>
<td colspan="2">(0.5~10.00*10^9)/L<br />
(10.10~99.9*10^9)/L</td>
<td colspan="3">(±0.5*10^9)/L<br />
±5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>RBC</td>
<td colspan="2">(0.05~1.00*10^12)/L (1.01~9.99*10^12)/L</td>
<td colspan="3">(±0.05*10^12)/L<br />
±5%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>HGB</td>
<td colspan="2">(2~70g)/L<br />
(71~300.0g)/L</td>
<td colspan="3">(±2.0g)/L<br />
±2%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>PLT</td>
<td colspan="2">(10~100*10^9)/L<br />
(101~999*10^9)/L</td>
<td colspan="3">(±10.0*10^9)/L<br />
±8%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="6">Precision</td>
<td>Parameter</td>
<td colspan="2">Repeatability</td>
<td colspan="3">Measurement Range</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>WBC</td>
<td colspan="2">≤6.0%</td>
<td colspan="3">(3.5~9.5*10^9)/L</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>RBC</td>
<td colspan="2">≤3.0%</td>
<td colspan="3">(3.8~5.8*10^12)/L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>HGB</td>
<td colspan="2">≤2.5%</td>
<td colspan="3">(115~175g)/L</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>PLT</td>
<td colspan="2">≤10.0%</td>
<td colspan="3">(125~350*10^9)/L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>HCT</td>
<td colspan="2">≤3.0%</td>
<td colspan="3">35%~50%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>External Size(W*D*H)</td>
<td colspan="6">295*467*418mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Packed Size(W*D*H)</td>
<td colspan="6">Instrument: 404*564*616mm; Reagent: 340*340*340mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td colspan="6">19kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Gross Weight</td>
<td colspan="6">Instrument: 31kg; Reagent: 13kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/3-part-auto-hematology-analyzer-bk-3200/">3-part Auto Hematology Analyzer BK-3200</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>5-part Auto Hematology Analyzer BK-6310</title>
		<link>https://keylaser.am/product/5-part-auto-hematology-analyzer-bk-6310/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 18 Sep 2024 10:42:13 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=8931</guid>

					<description><![CDATA[<p>This 5-part auto hematology analyzer is applicable for detecting the parameters of WBC, RBC, PLT, HGB, etc. (see Section 3.2. Parameters for details) in anticoagulated venous whole blood or capillary blood, as well as WBC 5-part differential analysis and WBC counting.</p>
<p>The post <a href="https://keylaser.am/product/5-part-auto-hematology-analyzer-bk-6310/">5-part Auto Hematology Analyzer BK-6310</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong><br />
1. Throughput 60t/h.<br />
2. 14 inch touch screen.<br />
3. Tri-angle laser scatter + flow cytometry method + impedance method for RBC and PLT counting.<br />
4. 3D holographic scattergram displays the accurate 5 part differentiation of WBC.<br />
5. Large storage capacity: 100,000 results(including histogram, scattergram, patient information).</p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="866">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td width="149">Model</td>
<td colspan="4">BK-6310</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="149">Throughput</td>
<td colspan="4">60 tests/hour</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="149">Assay Items</td>
<td colspan="4">5 parts, 29 parameters, 3 histograms, 3D scattergram</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="149">Principle</td>
<td colspan="4">Tri-angle laser scatter, Flow cytometrymethod, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="290">Test Mode</td>
<td colspan="4">CBC mode, CBC+DIFF mode venous whole blood, Capillary whole blood and prediluted</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="132">Parameters</td>
<td colspan="4">WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS#</p>
<p>4 research parameter: ALY%, ALY#, IG%, IG#</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="5" width="290">Performance</td>
<td width="188">Item</td>
<td width="132">Linearity Range</td>
<td width="106">Carry Over</td>
<td width="290">CV</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="188">WBC</td>
<td width="132">0~300*10^9/L</td>
<td width="106">≤0.5%</td>
<td width="290">≤2.0%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="188">RBC</td>
<td width="132">0~8.00*10^12/L</td>
<td width="106">≤0.5%</td>
<td width="290">≤1.5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="188">HGB</td>
<td width="132">0~250g/L</td>
<td width="149">≤0.5%</td>
<td width="149">≤1.5%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="149">PLT</td>
<td width="149">0~3000*10^9/L</td>
<td width="149">≤1.0%</td>
<td width="149">≤4.0%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="149">Sample Volume</td>
<td colspan="4">CBC+DIFF mode: ≤20μl</p>
<p>CBC mode: ≤10μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="undefined">Storage</td>
<td colspan="4">10,000 results including histogram, scattergram and patient information</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="undefined">Interface</td>
<td colspan="4">4 USB ports, 1 LAN port Bi-direction LIS, support HL7 protocol, Internal RFID reader</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="undefined">Power Supply</td>
<td colspan="4">AC220V±10%, 50/60Hz; 110V±10%, 60Hz; 400VA</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="undefined">Package Size(W*D*H)</td>
<td colspan="4">575*490*690mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="undefined">Gross Weight</td>
<td colspan="4">46kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="undefined">Reagent Package Size</td>
<td colspan="4">330*330*330mm, 400*290*240mm, 400*290*240mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="undefined">Reagent Gross Weight</td>
<td colspan="4">22kg, 2kg, 1kg</td>