<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Automatic Chemiluminescence Immunoassay System Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-tag/automatic-chemiluminescence-immunoassay-system/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-tag/automatic-chemiluminescence-immunoassay-system/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Thu, 10 Oct 2024 10:11:36 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>Automatic Chemiluminescence Immunoassay System Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-tag/automatic-chemiluminescence-immunoassay-system/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Automatic Chemiluminescence Immunoassay System BKI2200</title>
		<link>https://keylaser.am/product/automatic-chemiluminescence-immunoassay-system-bki2200/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 10:11:35 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11214</guid>

					<description><![CDATA[<p><strong>Introduction:</strong><br />
The chemiluminescence immunoassay system uses magnetic particle separation technology, which uses magnetic particles as antibody carriers, which can be evenly distributed in the liquid phase reaction system, with faster reaction speed and higher efficiency. Using enzymatic chemiluminescence method, the light signal is more stable. A new generation of enzymatic substrates, with higher sensitivity and faster luminescence.</p>
<p>The post <a href="https://keylaser.am/product/automatic-chemiluminescence-immunoassay-system-bki2200/">Automatic Chemiluminescence Immunoassay System BKI2200</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BKI2200</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
<div class="ast-oembed-container " style="height: 100%;"><iframe title="BIOBASE Automatic Chemiluminescence Immunoassay System BKI2200" width="1778" height="1000" src="https://www.youtube.com/embed/etvXaFAKUIA?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
<p>&nbsp;</p>
<p>&nbsp;</p>
<figure id="attachment_11218" aria-describedby="caption-attachment-11218" style="width: 1040px" class="wp-caption alignnone"><img fetchpriority="high" decoding="async" class="wp-image-11218 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/bki2200.webp" alt="Automatic Chemiluminescence Immunoassay System BKI2200" width="1040" height="629" srcset="https://keylaser.am/wp-content/uploads/2024/10/bki2200.webp 1040w, https://keylaser.am/wp-content/uploads/2024/10/bki2200-300x181.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/bki2200-1024x619.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/bki2200-768x464.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/bki2200-600x363.webp 600w" sizes="(max-width: 1040px) 100vw, 1040px" /><figcaption id="caption-attachment-11218" class="wp-caption-text"> </figcaption></figure>
<p><strong>Advantages:</strong></p>
<p><strong>1. Operation Module：</strong></p>
<p>Tubular enzymatic chemiluminescence</p>
<p>The max speed of a single machine is 240t/h</p>
<p>Carrying contamination rate&lt;10<sup>-5</sup></p>
<p>High precision: intra-batch precision≤8%</p>
<p><strong>2. Control Module:</strong></p>
<p>Ergonomic design increased operator comfort</p>
<p>0.68 square meters, highly integrated and simplified patented design</p>
<p>Convenient operation: support LIS two-way communication, scan the code to test</p>
<p>Smooth human-computer interaction experience: the touch screen and the frame are integrated into the machine, and all consumables can be loaded online in real time</p>
<p><strong>3. System Layout：</strong></p>
<p><img decoding="async" class="wp-image-11215 size-full" style="font-style: inherit; font-weight: 600;" src="https://keylaser.am/wp-content/uploads/2024/10/bki2200-1.webp" alt="Automatic Chemiluminescence Immunoassay System BKI2200" width="1138" height="355" srcset="https://keylaser.am/wp-content/uploads/2024/10/bki2200-1.webp 1138w, https://keylaser.am/wp-content/uploads/2024/10/bki2200-1-300x94.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/bki2200-1-1024x319.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/bki2200-1-768x240.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/bki2200-1-600x187.webp 600w" sizes="(max-width: 1138px) 100vw, 1138px" /></p>
<p><img loading="lazy" decoding="async" class="wp-image-11216 size-full" style="font-style: inherit; font-weight: 600;" src="https://keylaser.am/wp-content/uploads/2024/10/bki2200-2.webp" alt="Automatic Chemiluminescence Immunoassay System BKI2200" width="1172" height="361" srcset="https://keylaser.am/wp-content/uploads/2024/10/bki2200-2.webp 1172w, https://keylaser.am/wp-content/uploads/2024/10/bki2200-2-300x92.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/bki2200-2-1024x315.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/bki2200-2-768x237.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/bki2200-2-600x185.webp 600w" sizes="auto, (max-width: 1172px) 100vw, 1172px" /></p>
<p><img loading="lazy" decoding="async" class="wp-image-11217 size-full" style="font-style: inherit; font-weight: 600;" src="https://keylaser.am/wp-content/uploads/2024/10/bki2200-3.webp" alt="Automatic Chemiluminescence Immunoassay System BKI2200" width="1040" height="351" srcset="https://keylaser.am/wp-content/uploads/2024/10/bki2200-3.webp 1040w, https://keylaser.am/wp-content/uploads/2024/10/bki2200-3-300x101.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/bki2200-3-1024x346.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/bki2200-3-768x259.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/bki2200-3-600x203.webp 600w" sizes="auto, (max-width: 1040px) 100vw, 1040px" /></p>
<p><strong>4. Instrument Software Module:</strong></p>
<p><strong>Humanized software functions</strong></p>
<p>Reagent loading and sample operation are convenient and intuitive</p>
<p>Intuitive display of sample status in testing</p>
<p>Support checking experiment results by sample or project</p>
<p><strong>Reagents and consumables status warning</strong></p>
<p>Accurately record the use of reagents for each project</p>
<p>Accurately record the remaining amount of consumables</p>
<p>Timely alarm when the remaining consumables is insufficient</p>
<p><strong>Simple and intuitive quality control process</strong></p>
<p>Convenient addition of quality control experiments</p>
<p>Intuitive display of quality control results</p>
<p>Support various forms of T-P chart and L-J chart</p>
<p><strong>Convenient and flexible maintenance functions</strong></p>
<p>The maintenance program is comprehensive</p>
<p>Individual maintenance work can be flexibly chosen</p>
<p>Daily, monthly and yearly maintenance work is clearly distinguished</p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="100%" align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td width="259">Model</td>
<td width="624">BKI2200</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="259">Throughput</td>
<td width="624">240T/H</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="259">Principle</td>
<td width="624">Magnetic particle enzymatic chemiluminescence</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="259">Modes of Operation</td>
<td width="624">Random, Batch and STAT</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="259">Separation Method</td>
<td width="624">Magnetic separation technology</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="259">Sample Positions</td>
<td width="624">60(Each position could be used as an emergency position)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="259">Reagent Positions</td>
<td width="624">25pcs(2~8℃ refrigeration)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="259">Incubation Positions</td>
<td width="624">90</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="259">Time to 1st Result</td>
<td width="624">12 min</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="259">Sample Volume</td>
<td width="624">10~200μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="259">Detection Precision</td>
<td width="624">CV≤8%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="259">Carry-over Rate</td>
<td width="624">≤10<sup>-5</sup></td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="259">Correlation Coefficient</td>
<td width="624">r≥0.99</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="259">Calibration Stability</td>
<td width="624">28 days</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="259">Calibration Type</td>
<td width="624">6/7-point calibration</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="259">Software System</td>
<td width="624">Comes with a screen,Linux system</p>
<p>Bi-direction, support HL7 protocol</p>
<p>Intuitive user interface, Intelligent data management</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="259">Interface</td>
<td width="624">TCP/IP network interface</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="259">Other Function</td>
<td width="624">Liquid level detection</p>
<p>Anti-collision function</p>
<p>Sample barcode scanning</p>
<p>Intelligent alarm prompt</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="259">Power Supply</td>
<td width="624">AC100~240V, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="259">External Size(W*D*H)</td>
<td width="624">1000*685*750</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="259">Net Weight</td>
<td width="624">132kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="259">Package Size(W*D*H)</td>
<td width="624">1338*838*954mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="259">Gross Weight</td>
<td width="624">201kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<p><strong>Reagent Menu:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index1">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td><strong>Thyroid</strong></td>
<td><strong>Cardiac Marker</strong></td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>TSH</td>
<td>cTnl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>TT4</td>
<td>NT-proBNP</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>TT3</td>
<td>CK-MB</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>FT4</td>
<td>MYO</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>FT3</td>
<td><strong>Rheumatoid</strong></td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>TgAb</td>
<td>Anti-ccp</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>TPOAb</td>
<td>Β2-MG</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>TG</td>
<td><strong>Liver Fibrosis</strong></td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Anti-TSHR</td>
<td>CIV</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>CT</td>
<td>HA</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td><strong>Fertility</strong></td>
<td>P III NP</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>β-HCG</td>
<td>LN</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>E2</td>
<td><strong>Anemia</strong></td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>P</td>
<td>FA</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>T</td>
<td>VB12</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>PRL</td>
<td>FERRITIN</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>FSH</td>
<td><strong>Growth</strong></td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>LH</td>
<td>GH</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>DHEA-S</td>
<td>IGF-I*</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>SHBG</td>
<td><strong>Glycometabolism</strong></td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>AMH*</td>
<td>INS</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td><strong>Hypertension</strong></td>
<td>C-P</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>ALD</td>
<td><strong>Pepsinogen</strong></td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>ACTH</td>
<td>PG I</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Cortisol</td>
<td>PG II</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Renin</td>
<td><strong>Inflammation</strong></td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>AⅡ*</td>
<td>PCT</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td><strong>Tumor Marker</strong></td>
<td>IL-6</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>CA125</td>
<td><strong>Early Screening</strong></td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>CA15-3</td>
<td>FE3</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>CA19-9</td>
<td>Free β-HCG</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>AFP</td>
<td>PAPP-A</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>CEA</td>
<td><strong>Bone Metabolism</strong></td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>t-PSA</td>
<td>BGP</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>f-PSA</td>
<td>25-OH-Vit-D</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>CA72-4</td>
<td>iPTH</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>SCC</td>
<td>PINP*</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>CA242</td>
<td><strong>I</strong><strong>nfectious</strong></td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>CA50</td>
<td>HBeAb*</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>NSE</td>
<td>HBeAg*</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>CYFRA21-1</td>
<td>HBcAb*</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>HE4</td>
<td>HBsAb*</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>ProGRP</td>
<td>HBsAg*</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td></td>
<td>Anti-HBc lgM*</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td></td>
<td>HIV Ag/Ab*</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td></td>
<td>Anti-TP*</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td></td>
<td>Anti-HCV*</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/automatic-chemiluminescence-immunoassay-system-bki2200/">Automatic Chemiluminescence Immunoassay System BKI2200</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Automatic Chemiluminescence Immunoassay System</title>
		<link>https://keylaser.am/product/automatic-chemiluminescence-immunoassay-system/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 09:55:58 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11200</guid>

					<description><![CDATA[<p><strong>Introduction:</strong></p>
<p>The chemiluminescence immunoassay system usesmagnetic particle separation technology, which usesmagnetic particles as antibody carriers, which can beevenly distributed in the liquid phase reaction systemwith faster reaction speed and higher efficiency. Usingenzymatic chemiluminescence method, the light signalis more stable. A new generation of enzymatic substrateswith higher sensitivity and faster luminescence.</p>
<p>The post <a href="https://keylaser.am/product/automatic-chemiluminescence-immunoassay-system/">Automatic Chemiluminescence Immunoassay System</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BKI1100</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
<div class="ast-oembed-container " style="height: 100%;"><iframe loading="lazy" title="BIOBASE Automatic Chemiluminescence Immunoassay System" width="1778" height="1000" src="https://www.youtube.com/embed/vM37ln3D44I?start=2&#038;feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
<p>&nbsp;</p>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><img loading="lazy" decoding="async" class="wp-image-11201 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/BK1100.webp" alt="Automatic Chemiluminescence Immunoassay System" width="1088" height="197" srcset="https://keylaser.am/wp-content/uploads/2024/10/BK1100.webp 1088w, https://keylaser.am/wp-content/uploads/2024/10/BK1100-300x54.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/BK1100-1024x185.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/BK1100-768x139.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/BK1100-600x109.webp 600w" sizes="auto, (max-width: 1088px) 100vw, 1088px" /><img loading="lazy" decoding="async" class="alignnone wp-image-11202 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/BKI1100-1.webp" alt="Automatic Chemiluminescence Immunoassay System" width="1102" height="498" srcset="https://keylaser.am/wp-content/uploads/2024/10/BKI1100-1.webp 1102w, https://keylaser.am/wp-content/uploads/2024/10/BKI1100-1-300x136.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/BKI1100-1-1024x463.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/BKI1100-1-768x347.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/BKI1100-1-600x271.webp 600w" sizes="auto, (max-width: 1102px) 100vw, 1102px" /></p>
<p>&nbsp;</p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<p><img loading="lazy" decoding="async" class="wp-image-11203 size-large" style="font-style: inherit; font-weight: 600;" src="https://keylaser.am/wp-content/uploads/2024/10/BKI1100-2-1024x485.webp" alt="Automatic Chemiluminescence Immunoassay System" width="1024" height="485" srcset="https://keylaser.am/wp-content/uploads/2024/10/BKI1100-2-1024x485.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/BKI1100-2-300x142.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/BKI1100-2-768x364.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/BKI1100-2-600x284.webp 600w, https://keylaser.am/wp-content/uploads/2024/10/BKI1100-2.webp 1083w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /></p>
</div>
<p>&nbsp;</p>
<p><strong style="font-size: 16px;">Technical Parameters:</strong></p>
</div>
</div>
</div>
</div>
</div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="866">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td width="252">Model</td>
<td width="613">BKI1100</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="252">Throughput</td>
<td width="613">180T/H</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="252">Principle</td>
<td width="613">Magnetic particle enzymatic chemiluminescence</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="252">Modes of Operation</td>
<td width="613">Random, Batch and STAT</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="252">Separation Method</td>
<td width="613">Magnetic separation technology</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="252">Sample Positions</td>
<td width="613">60(Each position could be used as an emergency position)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="252">Reagent Positions</td>
<td width="613">25pcs(2~8℃ refrigeration)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="252">Incubation Positions</td>
<td width="613">58</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="252">Time to 1st Result</td>
<td width="613">18 minutes</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="252">Sample Volume</td>
<td width="613">10~200μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="252">Detection Precision</td>
<td width="613">CV≤8%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="252">Carry-over Rate</td>
<td width="613">≤10<sup>-5</sup></td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="252">Correlation Coefficient</td>
<td width="613">r≥0.99</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="252">Calibration Stability</td>
<td width="613">28 days</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="252">Calibration Type</td>
<td width="613">6/7-point calibration</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="3" width="252">Software System</td>
<td colspan="1" rowspan="3" width="613">Windows 7/8/10, 32 or 64 bit, Bi-direction, support HL7 protocol,<br />
Intuitive user interface, intelligent data management</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="252">Interface</td>
<td width="613">TCP/IP network interface</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4" width="252">Other Function</td>
<td width="613">Liquid level detection</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="613">Anti-collision function</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="613">Sample barcode scanning</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="613">Intelligent alarm prompt</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="252">Power Supply</td>
<td width="613">AC220V, 50/60Hz(Standard); AC110V, 60Hz(Optional)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="252">External Size(W*D*H)</td>
<td width="613">768*771*568mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="252">Net Weight</td>
<td width="613">90kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="252">Package Size(W*D*H)</td>
<td width="613">940*840*1105mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="252">Gross Weight</td>
<td width="613">150kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/automatic-chemiluminescence-immunoassay-system/">Automatic Chemiluminescence Immunoassay System</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
