<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Battery Stability Test Chamber Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-tag/battery-stability-test-chamber/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-tag/battery-stability-test-chamber/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Thu, 20 Mar 2025 06:25:13 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>Battery Stability Test Chamber Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-tag/battery-stability-test-chamber/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Battery Stability Test Chamber</title>
		<link>https://keylaser.am/product/battery-stability-test-chamber/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 20 Mar 2025 06:25:13 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=13387</guid>

					<description><![CDATA[<div><strong>Model : BSTC-250; BSTC-460; BSTC-760; BSTC-860; BSTC-1000</strong></div>
<div></div>
<p>Control Mode : Intelligent Fuzzy PID Control, Normal/Program Operation<br />
Convection Method : Forced convection<br />
Working Conditions : 5 ℃~35 ℃ (it is recommended to use an ambient temperature of 25~28 ℃)<br />
Temperature Control Range : -10℃～+85℃</p>
<div>This battery stability testing chamber is the first choice for battery research and production.</div>
<p>The post <a href="https://keylaser.am/product/battery-stability-test-chamber/">Battery Stability Test Chamber</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2><strong>Battery Stability Test Chamber Specification:</strong></h2>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="905">
<thead>
<tr class="firstRow">
<th width="166.33333333333334">Model</th>
<th width="97.33333333333333">BSTC-250</th>
<th width="">BSTC-460</th>
<th width="">BSTC-760</th>
<th width="">BSTC-860</th>
<th width="">BSTC-1000</th>
</tr>
</thead>
<tbody>
<tr>
<td width="150">Chamber Capaticy</td>
<td width="97.33333333333333">250L</td>
<td width="131">460L</td>
<td width="131">760L</td>
<td width="131">860L</td>
<td width="131">1000L</td>
</tr>
<tr>
<td width="145">Display</td>
<td colspan="5" width="701.3333333333334">7-inch LCD touch screen</td>
</tr>
<tr>
<td width="145">Control Mode</td>
<td colspan="5" width="701.3333333333334">Intelligent Fuzzy PID Control, Normal/Program Operation</td>
</tr>
<tr>
<td width="145">Convection Method</td>
<td colspan="5" width="701.3333333333334">Forced convection</td>
</tr>
<tr>
<td width="145">Working Conditions</td>
<td colspan="5" width="701.3333333333334">5 ℃~35 ℃ (it is recommended to use an ambient temperature of 25~28 ℃)</td>
</tr>
<tr>
<td width="161.33333333333334">Temperature Control Range</td>
<td colspan="5" width="701.3333333333334">-10℃～+85℃</td>
</tr>
<tr>
<td width="145">Temperature Resolution</td>
<td colspan="5" width="701.3333333333334">0.1℃</td>
</tr>
<tr>
<td width="145">Temperature Control Accuracy</td>
<td colspan="5" width="701.3333333333334">±0.1℃</td>
</tr>
<tr>
<td width="145">Temperature Deviation(15~45℃)</td>
<td colspan="5" width="701.3333333333334">±0.2~0.6℃</td>
</tr>
<tr>
<td width="145">Insulation Material</td>
<td colspan="5" width="701.3333333333334">Polyurethane integral foaming</td>
</tr>
<tr>
<td width="145">Program Control</td>
<td colspan="5" width="701.3333333333334">Programmable intelligence, program operation mode, and regular operation mode</td>
</tr>
<tr>
<td width="145">Defrost Function</td>
<td colspan="5" width="701.3333333333334">Automatic defrost or intermittent defrost</td>
</tr>
<tr>
<td width="145">Test Hole</td>
<td colspan="5" width="701.3333333333334">Φ 50, 75, 100 (choose one)</td>
</tr>
<tr>
<td width="145">Refrigeration Method</td>
<td colspan="5" width="701.3333333333334">Environmentally friendly variable frequency compression refrigeration technology</td>
</tr>
<tr>
<td width="145">Temperature Sensor</td>
<td colspan="5" width="701.3333333333334">German HERAEUS PT100 temperature sensor</td>
</tr>
<tr>
<td width="145">Safety Setting</td>
<td colspan="5" width="701.3333333333334">automatic start, automatic stop, Power resumption, scheduled operation, with compressor overpressure protection, overtemperature alarm, leakage protection, door open alarm, and sensor malfunction alarm functions.</td>
</tr>
<tr>
<td width="145">Shelves</td>
<td colspan="5" width="701.3333333333334">Three (Standard)</td>
</tr>
<tr>
<td width="145">Optional Accessories</td>
<td colspan="5" width="701.3333333333334">Printer, Computer monitoring software, Remote control alarm system</td>
</tr>
<tr>
<td width="145">Power Supply</td>
<td colspan="5" width="701.3333333333334">AC220V, 50/60Hz</td>
</tr>
<tr>
<td width="150">Consumption</td>
<td width="97.33333333333333">1100W</td>
<td width="131">1200W</td>
<td width="131">2000W</td>
<td width="131">2000W</td>
<td width="131">2000W</td>
</tr>
<tr>
<td width="150">Chamber Size (W×D×H)(mm)</td>
<td width="97.33333333333333">912x670x410</td>
<td width="131">1105x750x560</td>
<td width="131">1300x1180x500</td>
<td width="131">1300x1180x500</td>
<td width="131">1300x1180x660</td>
</tr>
<tr>
<td width="150">External Size</p>
<p>(W×D×H)(mm)</td>
<td width="97.33333333333333">1510x850x797</td>
<td width="131">1765x933x960</td>
<td width="131">1790x1490x887</td>
<td width="131">1790x1490x887</td>
<td width="131">1790x1490x1050</td>
</tr>
<tr>
<td width="150">Shipping Size (W×D×H)(mm)</td>
<td width="97.33333333333333">1730x975x960</td>
<td width="131">2030x1090x1045</td>
<td width="131">2030x1650x1050</td>
<td width="131">2100x1530x1190</td>
<td width="131">2030x1650x1210</td>
</tr>
<tr>
<td width="150">N.W./G.W. (kg)</td>
<td width="97.33333333333333">160/190</td>
<td width="131">210/240</td>
<td width="131">295/335</td>
<td width="131">310/350</td>
<td width="131">355/395</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>Battery stability testing chamber is used for battery performance testing to ensure that the battery undergoes constant current and constant voltage charge/discharge processes, in order to analyze and evaluate the performance and behavior under the specified environmental conditions during the test.</p>
<p><img fetchpriority="high" decoding="async" class="wp-image-13388 size-full" src="https://keylaser.am/wp-content/uploads/2025/03/Battery-Stability-Test-Chamber.webp" alt="Battery Stability Test Chamber" width="1436" height="967" srcset="https://keylaser.am/wp-content/uploads/2025/03/Battery-Stability-Test-Chamber.webp 1436w, https://keylaser.am/wp-content/uploads/2025/03/Battery-Stability-Test-Chamber-300x202.webp 300w, https://keylaser.am/wp-content/uploads/2025/03/Battery-Stability-Test-Chamber-1024x690.webp 1024w, https://keylaser.am/wp-content/uploads/2025/03/Battery-Stability-Test-Chamber-768x517.webp 768w, https://keylaser.am/wp-content/uploads/2025/03/Battery-Stability-Test-Chamber-600x404.webp 600w" sizes="(max-width: 1436px) 100vw, 1436px" /></p>
<p>&nbsp;</p>
<h2><strong>Battery Stability Test Chamber Features:</strong></h2>
<ol class=" list-paddingleft-2">
<li>Electronic PID control, intelligent operating system, high-performance processor</li>
<li>Utilizes a full-color LCD touch screen</li>
<li>Data recording and storage function; capable of storing test data for over 10 years; original data exportable via USB drive</li>
<li>Temperature data can be viewed through curve display</li>
<li>Features event recording, permission management, multi-point temperature correction, and variable frequency refrigeration system</li>
<li>Equipped with Danfoss (SECOP) compressor and German EBM condensing fan, environmentally friendly refrigerant</li>
<li>Capacitive temperature sensor</li>
<li>Box insulation material using integrated polyurethane foam technology</li>
<li>Double-door structure design, with tempered glass inner door</li>
<li>The standard communication interfaces USB, RS485, and RS232 are reserved for the cabinet</li>
</ol>
<p>The post <a href="https://keylaser.am/product/battery-stability-test-chamber/">Battery Stability Test Chamber</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
