<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Biological Safety Cabinet Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-tag/biological-safety-cabinet/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-tag/biological-safety-cabinet/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Mon, 09 Mar 2026 13:13:54 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>Biological Safety Cabinet Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-tag/biological-safety-cabinet/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>NSF Certified Class II A2 Biological Safety Cabinet</title>
		<link>https://keylaser.am/product/nsf-certified-class-ii-a2-biological-safety-cabinet-2/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 09 Mar 2026 13:13:53 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14491</guid>

					<description><![CDATA[<p><label>Model: </label>BSC-2FA2-NA, BSC-2FA2-GL</p>
<p>The NSF Certified Class II Biosafety Cabinet is a top-tier laboratory safety enclosure designed to provide maximum protection for operators, samples, and the environment when working with moderate-risk biological agents.</p>
<p>The post <a href="https://keylaser.am/product/nsf-certified-class-ii-a2-biological-safety-cabinet-2/">NSF Certified Class II A2 Biological Safety Cabinet</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="ast-oembed-container " style="height: 100%;"><iframe title="BIOBASE NSF Certified Class II A2 Biological Safety Cabinet BSC 2FA2 NA" width="1778" height="1000" src="https://www.youtube.com/embed/dVk--sS9Mys?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
<p>&nbsp;</p>
<div>
<p><strong>Features:</strong></p>
</div>
<p>1. Motorized front window.</p>
<p>2. 7-inch large touch color display: touch operation, real-time and clearer display of various values of the safety cabinet, dynamic air flow pattern diagram, fault alarm sound and light prompt.</p>
<p>3. The power-on password can be set to prevent mis-operation by irrelevant personnel.</p>
<p>4. EC Fan, automatically adjust the wind speed.</p>
<p>5. With power-failure memory function, the state before power-failure will be restored after power-on and there will be visual prompts and alarms.</p>
<p>6. The integrated design of the operation area makes it easy to disassemble and clean.</p>
<p>7. The cabinet is separated from the base. The height of the adjustable base can be customized.</p>
<p>8. Interlocking function:UV lamp and front window; UV lamp and fan; fan and front window.</p>
<p>9. It has the function of appointment timing, which can automatically set the time of starting and shutting down the safety cabinet and the running time of ultraviolet lamps, fan and sockets.</p>
<p>10. The front window closes the trigger signal, so that the sterilization and disinfection function of the ultraviolet lamp is normally turned on.</p>
<p>11. The one-piece hand resting surface has a larger contact area with the arm and is more comfortable. air speed adjustable with filter block.</p>
<p><img fetchpriority="high" decoding="async" class=" lazyloaded" src="https://ikrorwxhqjrilj5q.ldycdn.com/cloud/lqBprKkmljSRllqkmpopip/07-08-NSF-Certified-Class-II-A2-Biological-Safety-Cabinet.jpg" alt="07-08 NSF Certified Class II A2 Biological Safety Cabinet" width="1500" height="1116" data-original="//ikrorwxhqjrilj5q.ldycdn.com/cloud/lqBprKkmljSRllqkmpopip/07-08-NSF-Certified-Class-II-A2-Biological-Safety-Cabinet.jpg" /></p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td rowspan="2">Model</td>
<td>BSC-2FA2-NA</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>BSC-2FA2-GL</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>External Size(W*D*H)</td>
<td>700*650*1920mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Internal Size(W*D*H)</td>
<td>600*500*540mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Work Surface Hight</td>
<td>750mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Max Opening</td>
<td>370mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Tested Opening</td>
<td>Safety height 254mm(10&#8243;)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Inflow</td>
<td>290m³/h(170cfm)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Downflow</td>
<td>55%: 360m³/h(211cfm)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Exhausl</td>
<td>45%: 290m³/h(170cfm)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Front Window</td>
<td>Two-layer laminated toughened glass&gt;6mm, Anti UV</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>U PA Filter</td>
<td>≥99.9995% efficiency at 0.12μm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Filter Guard Type</td>
<td>Aluminum alloy frame</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Noise</td>
<td>NSF 49≤67dB</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Ilumination</td>
<td>≥1000Lux</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Display</td>
<td>Capacitive touch screen</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Waterproof Socket</td>
<td>Two, total consumption≤500W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Ground Resistance</td>
<td>≤0.1Ω</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Power Supply</td>
<td>AC230V, 50/60Hz; AC115V, 60Hz, Full load Amps: 9A, BTU/Hr: 1689</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Consumption</td>
<td>≤500W</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Alarn</td>
<td>Abnormal airlow velocity; Filter replacement; Front window at unsafe height</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Motor</td>
<td>EC motor, 115V&amp;230V acceptable, speed adjustable, high efficiency and low power consumption</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="2">Material</td>
<td>Working area: 304 stainless steel</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Frame and decoratve plate: cold-rolled steel with anti-bacteria power coating</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>UV Lamp</td>
<td>15W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>LED   Lamp</td>
<td>10W*2</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Standard Accessory</td>
<td>LED Lamp*2, UV lamp*2, Base stand, Drain valve, Waterproof sockets, Remote control</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Optional Accessory</td>
<td>Armrest, Airlow tester, Formalin fumigation sterlizer, Infrared sterlizer, Remote control, SS water tap*1&amp;gas tap*1</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>150kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size(W*D*H)</td>
<td>Carton: 820*880*1470mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>152kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/nsf-certified-class-ii-a2-biological-safety-cabinet-2/">NSF Certified Class II A2 Biological Safety Cabinet</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Basic Series Class Il A2 Biological Safety Cabinet</title>
		<link>https://keylaser.am/product/basic-series-class-il-a2-biological-safety-cabinet/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 05 Mar 2026 10:32:16 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14165</guid>

					<description><![CDATA[<p><label>Model: </label>11231 BBC 86</p>
<p>Biological safety cabinet is necessary equipment in the laboratory in the search of microbiology, biomedical, DNA recombinant, animal experiment and biological products, especially in the occasion that operator need to adopt protective measure, such us medical and health, medical research. Our equipment provides a safety working environment which don't have bacterial and dust in the process of bacterial culture.</p>
<p>The post <a href="https://keylaser.am/product/basic-series-class-il-a2-biological-safety-cabinet/">Basic Series Class Il A2 Biological Safety Cabinet</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="ast-oembed-container " style="height: 100%;"><iframe title="BIOBASE Class II A2 Biosafety Cabinet 11231BBC86" width="1778" height="1000" src="https://www.youtube.com/embed/q7q37QGQZ34?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
<p>&nbsp;</p>
<p><strong>Features:</strong></p>
<p>1. Small dimension, save space.</p>
<p>2. Centrifugal fan, speed adjustable, H14 HEPA filter.</p>
<p>3. Motorized front window: The front window is motorized for convenient, one-hand operation.</p>
<p>4. Audio and visual alarm: Abnormal airflow velocity, Filter replacement, Front window at unsafe height, High filter pressure alarm.</p>
<p>5. Time reserve function: This can save 30 minutes waiting time after activating the cabinet and the sterilization time after experiment.</p>
<p>6. Remote control: Each function can be realized 6 meters away from the cabinet by remote control, which can protect the operator under emergency.</p>
<p>7. Large LCD display: Operators can check detailed status of the cabinet, such as inflow and downflow velocity, work area temperature and humidity, filter pressure, UV working time and filter working time, filter life indicator etc.</p>
<p>8. With memory function in case of power-failure.</p>
<p>9. Interlock function: UV lamp and front window, UV lamp and blower, LED lamp, blower and front window.</p>
<p><img loading="lazy" decoding="async" class=" lazyloaded" src="https://ikrorwxhqjrilj5q.ldycdn.com/cloud/lnBprKkmljSRklnjonrjio/11-12-Basic-Series-Class-II-A2-Biosafety-Safety-Cabinet-11231BBC86.jpg" alt="11-12 Basic Series Class II A2 Biosafety Safety Cabinet 11231BBC86" width="1500" height="500" data-original="//ikrorwxhqjrilj5q.ldycdn.com/cloud/lnBprKkmljSRklnjonrjio/11-12-Basic-Series-Class-II-A2-Biosafety-Safety-Cabinet-11231BBC86.jpg" /></p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>11231 BBC 86</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size(W*D*H)</td>
<td>700*640*1230mm(without base stand)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Internal Size(W*D*H)</td>
<td>600*500*530mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Tested Opening</td>
<td>Safety height 200mm(8&#8243;)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Max Opening</td>
<td>370mm(15&#8243;)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Inflow Velocity</td>
<td>0.53±0.025m/s</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Down Flow Velocity</td>
<td>0.33±0.025m/s</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>HEPA Filter</td>
<td>Two, 99.995% efficiency at 0.3μm. Filter life indicator</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Front Window</td>
<td>Double-sided laminated glass</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Noise</td>
<td>≤67dB</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>UV Lamp</td>
<td>15W*1</p>
<p>UV timer, UV life indicator, emission of 253.7 nanometers for most efficient decontamination</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>LED Lamp</td>
<td>8W*2</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Illumination</td>
<td>≥1000Lux</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Consumption</td>
<td>500W</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Socket</td>
<td>Two, total load of two sockets: 500W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Display</td>
<td>LCD display</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Control System</td>
<td>Microprocessor</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Airflow System</td>
<td>70% air recirculation, 30% air exhaust</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Visual and Audio Alarm</td>
<td>Filter replacement, window over height, abnormal air flow velocity, High filter pressure alarm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Material</td>
<td>Work Zone: 304 stainless steel</p>
<p>Main Body: Cold-rolled steel with anti-bacteria powder coating</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Work Surface Height</td>
<td>750mm with optional base stand</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power Supply</td>
<td>AC220V±10%, 50/60Hz; 110V±10%, 60Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Standard Accessory</td>
<td>LED lamp*2, UV lamp*2, Remote control, Waterproof sockets*2</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Optional Accessory</td>
<td>SS Water tap*1, SS Gas tap*1, Base stand</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Packing Size(without base stand)</td>
<td>Carton: 810*760*1430mm</p>
<p>Wood: 850*810*1430mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Gross Weight(without base stand)</td>
<td>Carton: 120kg</p>
<p>Wood: 140kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Package Size(with base stand)</td>
<td>Carton: 860*810*1430mm</p>
<p>Wood: 970*850*1430mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Gross Weight(with base stand)</td>
<td>Carton: 139kg</p>
<p>Wood: 162kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/basic-series-class-il-a2-biological-safety-cabinet/">Basic Series Class Il A2 Biological Safety Cabinet</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>NSF Certified Class II B2 Biological Safety Cabinet</title>
		<link>https://keylaser.am/product/nsf-certified-class-ii-b2-biological-safety-cabinet-2/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 04 Mar 2026 17:08:24 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14102</guid>

					<description><![CDATA[<p><label>Model: </label>BSC-4FB2-NA BSC-4FB2-GL</p>
<p>This product belong to Class II B2 Biosafety Cabinet(BSC) which fully meets the requirements of US Standard ANSI/NSF49:2016. BSC is a kind of negative pressure filtration system for protecting operator, laboratory environment and experiment materials.</p>
<p>The post <a href="https://keylaser.am/product/nsf-certified-class-ii-b2-biological-safety-cabinet-2/">NSF Certified Class II B2 Biological Safety Cabinet</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. Motorized front window.</p>
<p>2. 7-inch large touch color display: touch operation, real-time and clearer display of various values of the safety cabinet, dynamic air flow pattern diagram, fault alarm sound and light prompt.</p>
<p>3. The power-on password can be set to prevent mis-operation by irrelevant personnel.</p>
<p>4. EC Fan, automatically adjust the wind speed.</p>
<p>5. With power-failure memory function, the state before power-failure will be restored after power-on and there will be visual prompts and alarms.</p>
<p>6. The integrated design of the operation area makes it easy to disassemble and clean.</p>
<p>7. The cabinet is separated from the base. The height of the adjustable base can be customized.</p>
<p>8. Interlocking function: UV lamp and front window; UV lamp and fan; fan and front window.</p>
<p>9. It has the function of appointment timing, which can automatically set the time of starting and shutting down the safety cabinet and the running time of ultraviolet lamps, fan and sockets.</p>
<p>10. The front window closes the trigger signal,so that the sterilization and disinfection function of the ultraviolet lamp is normally turned on.</p>
<p>11. The one-piece hand resting surface has a larger contact area with the arm and is more comfortable. air speed adjustable with filter block.</p>
<p><img loading="lazy" decoding="async" class=" lazyloaded" src="https://ikrorwxhqjrilj5q.ldycdn.com/cloud/llBprKkmljSRllqkrmnliq/30-31-NSF-Certified-Class-II-B2-Biological-Safety-Cabinet.jpg" alt="30-31 NSF Certified Class II B2 Biological Safety Cabinet" width="1500" height="1120" data-original="//ikrorwxhqjrilj5q.ldycdn.com/cloud/llBprKkmljSRllqkrmnliq/30-31-NSF-Certified-Class-II-B2-Biological-Safety-Cabinet.jpg" /></p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BSC-4FB2-NA</td>
<td>BSC-4FB2-GL</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size(W*D*H)</td>
<td colspan="2">1383*775*2250mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Internal Size(W*D*H)</td>
<td colspan="2">1210*600*660mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Tested Opening</td>
<td colspan="2">Safety height 200mm(8&#8243;)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Max Opening</td>
<td colspan="2">470mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Exhaust Airflow Volume</td>
<td colspan="2">100%: 1320m³/h(776cfm)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Front Window</td>
<td colspan="2">Motorized. Two-layer laminated toughened glass≥6mm. Anti UV</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>HEPA Filter</td>
<td colspan="2">Two, 99.995% efficiency at 0.12μm, filter life indicator</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Filter Guard Type</td>
<td colspan="2">Aluminum alloy frame</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Noise</td>
<td colspan="2">NSF49≤67dB/EN12469≤65dB</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Illumination</td>
<td colspan="2">≥1000Lux</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Display</td>
<td colspan="2">Color touch screen</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Waterproof Socket</td>
<td colspan="2">2, Total consumption: ≤500W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Tap</td>
<td colspan="2">Water tap*1, Gas tap *1</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Ground Resistance</td>
<td colspan="2">≤ 0.10Ω</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power Supply</td>
<td colspan="2">AC230V, 50Hz; 115V, 60Hz, Full load Amps: 9A, BTU/Hr: 1689</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Consumption</td>
<td colspan="2">400W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Alarm</td>
<td colspan="2">Abnormal airflow velocity; Filter replacement; Front window at unsafe height</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Motor</td>
<td colspan="2">EC motor, 115V&amp;230V acceptable, Speed adjustable, high efficiency and low power consumption</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Material</td>
<td colspan="2">Working area: 304 stainless steel</p>
<p>Frame and decorative plate: cold-rolled steel with anti-bacteria power coating</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="2">UV Lamp</td>
<td colspan="2">30W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Germicidal UV lamp, Emission of 253.7 nanometers for most efficient decontamination</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="2">Illuminating Lamp</td>
<td colspan="2">20W*2</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">LED lamp</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Standard Accessory</td>
<td colspan="2">LED lamp*2, UV lamp*2, Base stand, SS water tap*1, SS gas tap*1, Drain valve, Waterproof sockets*2, Stainless Steel IV Bar with 10 hooks, Remote control</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Optional Accessory</td>
<td colspan="2">Armrest, Airflow tester, Formalin fumigation sterilizer, Infrared sterilizer, Electric height adjustable base stand, Exhaust duct</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Package Size(W*D*H)</td>
<td colspan="2">1540*1080*1900mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Gross Weight</td>
<td colspan="2">340kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<p><strong>Note: </strong>Customers need to prepare an external exhaust fan or exhaust system by themselves.</p>
<p>The post <a href="https://keylaser.am/product/nsf-certified-class-ii-b2-biological-safety-cabinet-2/">NSF Certified Class II B2 Biological Safety Cabinet</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>EN Certified Biological Safety Cabinet with LCD Display</title>
		<link>https://keylaser.am/product/en-certified-biological-safety-cabinet-with-lcd-display/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 07 Oct 2024 14:56:38 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=10397</guid>

					<description><![CDATA[<p><strong>Introduction:</strong></p>
<p>The EN Class II A2 Biosafety Cabinet is a crucial piece of laboratory equipment designed to provide a safe working environment when handling biological materials that pose a moderate risk to the user and the environment.</p>
<p>The post <a href="https://keylaser.am/product/en-certified-biological-safety-cabinet-with-lcd-display/">EN Certified Biological Safety Cabinet with LCD Display</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BSC-3FA2 BSC-4FA2</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
<div class="ast-oembed-container " style="height: 100%;"><iframe loading="lazy" title="BIOBASE EN Certified Biological Safety Cabinet BSC-3FA2（3’）" width="1778" height="1000" src="https://www.youtube.com/embed/67UfDNSSS40?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
<p>&nbsp;</p>
<p><strong>Features: </strong></p>
<p>1. Large LCD display, all information displayed.</p>
<p>2. Automatic air speed adjustable with filter block</p>
<p>3. With memory function in case of power-failure.</p>
<p>4. Side &amp; back wall is made up of single piece stainless steel.</p>
<p>5. Interlock function: UV lamp and front window; UV lamp and blower, LED lamp; Blower and front window.</p>
<p>6. Front 10°slanted to offer operator comfort while working for long time, reduce glare and maximize reach into the work area.</p>
<p>&nbsp;</p>
<figure id="attachment_10398" aria-describedby="caption-attachment-10398" style="width: 1064px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-10398 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/3fa2.webp" alt="EN Certified Biological Safety Cabinet with LCD Display" width="1064" height="711" srcset="https://keylaser.am/wp-content/uploads/2024/10/3fa2.webp 1064w, https://keylaser.am/wp-content/uploads/2024/10/3fa2-300x200.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/3fa2-1024x684.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/3fa2-768x513.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/3fa2-600x401.webp 600w" sizes="auto, (max-width: 1064px) 100vw, 1064px" /><figcaption id="caption-attachment-10398" class="wp-caption-text"> </figcaption></figure>
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table border="1" align="left">
<tbody>
<tr class="firstRow">
<td colspan="2" valign="center">Model</td>
<td valign="center">BSC-3FA2</td>
<td valign="center">BSC-4FA2</td>
</tr>
<tr>
<td colspan="2" valign="center">External Size(W*D*H)</td>
<td valign="center">1087*775*2265mm</td>
<td valign="center">1383*775*2295mm</td>
</tr>
<tr>
<td colspan="2" valign="center">Internal Size(W*D*H)</td>
<td valign="center">910*600*660mm</td>
<td valign="center">1210*600*660mm</td>
</tr>
<tr>
<td colspan="2" valign="center">Work Surface Height</td>
<td colspan="2" valign="center">750mm</td>
</tr>
<tr>
<td colspan="2" valign="center">Max Opening</td>
<td valign="center">520mm (21&#8243;)</td>
<td valign="center">550mm (22&#8243;)</td>
</tr>
<tr>
<td colspan="2" valign="center">Tested Opening</td>
<td colspan="2" valign="center">Safety height 200mm (8&#8243;)</td>
</tr>
<tr>
<td rowspan="3" valign="center">Airflow Volume</td>
<td valign="center">Inflow</td>
<td valign="center">348m³/h(205cfm)</td>
<td valign="center">462m³/h(272cfm)</td>
</tr>
<tr>
<td valign="center">Down Flow</td>
<td valign="center">65%: 649m³/h(382cfm)</td>
<td valign="center">65%: 863m³/h(507cfm)</td>
</tr>
<tr>
<td valign="center">Exhaust</td>
<td valign="center">35%: 348m³/h(205cfm)</td>
<td valign="center">35%: 462m³/h(272cfm)</td>
</tr>
<tr>
<td colspan="2" valign="center">Front Window</td>
<td colspan="2" valign="center">Manual. Laminated toughened glass. Anti UV</td>
</tr>
<tr>
<td colspan="2" valign="center">HEPA Filter</td>
<td colspan="2" valign="center">Two, 99.995% efficiency at 0.3μm, filter life indicator</td>
</tr>
<tr>
<td colspan="2" valign="center">Filter Guard Type</td>
<td colspan="2" valign="center">Aluminum alloy frame</td>
</tr>
<tr>
<td colspan="2" valign="center">Noise</td>
<td colspan="2" valign="center">EN 12469≤65db</td>
</tr>
<tr>
<td colspan="2" valign="center">Illumination</td>
<td colspan="2" valign="center">≥1000Lux</td>
</tr>
<tr>
<td colspan="2" valign="center">Display</td>
<td colspan="2" valign="center">LCD display</td>
</tr>
<tr>
<td colspan="2" valign="center">Waterproof Socket</td>
<td colspan="2" valign="center">2, total consumption: ≤500W</td>
</tr>
<tr>
<td colspan="2" valign="center">Tap</td>
<td colspan="2" valign="center">Water tap*1, Gas tap *1</td>
</tr>
<tr>
<td colspan="2" valign="center">Ground Resistance</td>
<td colspan="2" valign="center">≤ 0.10Ω</td>
</tr>
<tr>
<td colspan="2" valign="center">Power Supply</td>
<td colspan="2" valign="center">AC230V, 50Hz</td>
</tr>
<tr>
<td colspan="2" valign="center">Consumption</td>
<td valign="center">≤550W</td>
<td valign="center">≤650W</td>
</tr>
<tr>
<td colspan="2" valign="center">Alarm</td>
<td colspan="2" valign="center">Abnormal airflow velocity, Filter replacement, Front window at unsafe height, High filter pressure alarm</td>
</tr>
<tr>
<td colspan="2" valign="center">AC Motor</td>
<td colspan="2" valign="center">One ECM motor, 230V acceptable, speed adjustable, high efficiency and low power consumption</td>
</tr>
<tr>
<td colspan="2" valign="center">Material</td>
<td colspan="2" valign="center">Working area: 304 stainless steel</p>
<p>Frame and decorative plate: cold-rolled steel with anti-bacteria power coating</td>
</tr>
<tr>
<td colspan="2" rowspan="2" valign="center">UV Lamp</td>
<td valign="center">20W</td>
<td valign="center">30W</td>
</tr>
<tr>
<td colspan="2" valign="center">Germicidal UV lamp, Emission of 253.7 nanometers for most efficient decontamination, UV timer, UV life indicator</td>
</tr>
<tr>
<td colspan="2" valign="center">LED Lamp</td>
<td valign="center">10W*2</td>
<td valign="center">18W*2</td>
</tr>
<tr>
<td colspan="2" valign="center">Standard Accessory</td>
<td colspan="2" valign="center">LED lamp*2, UV lamp*2, Base stand, SS water tap*1, SS gas tap*1, Drain valve, Waterproof sockets*2, Stainless steel I.V. bar with 10 hooks, Remote control</td>
</tr>
<tr>
<td colspan="2" valign="center">Optional Accessory</td>
<td colspan="2" valign="center">Armrest, Airflow tester, Formalin fumigation sterilizer,Infrared sterilizer,<br />
Electric height adjustable base stand, Motorized front window</td>
</tr>
<tr>
<td colspan="2" valign="center">Package Size (W*D*H)</td>
<td valign="center">1240*1060*1900mm</td>
<td valign="center">1540*1080*1900mm</td>
</tr>
<tr>
<td colspan="2" valign="center">Gross Weight</td>
<td valign="center">270kg</td>
<td valign="center">340kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/en-certified-biological-safety-cabinet-with-lcd-display/">EN Certified Biological Safety Cabinet with LCD Display</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Radiation Protection Biological Safety Cabinet</title>
		<link>https://keylaser.am/product/radiation-protection-biological-safety-cabinet/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 07 Oct 2024 14:52:06 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=10393</guid>

					<description><![CDATA[<div><strong>Introduction:</strong></div>
<p>The Radiation Protection Biological Safety Cabinet is an essential piece of equipment designed to ensure the highest level of safety in environments where hazardous biological and radioactive materials are handled. This advanced cabinet provides a secure and controlled workspace, combining robust radiation shielding with comprehensive biological protection.</p>
<p>The post <a href="https://keylaser.am/product/radiation-protection-biological-safety-cabinet/">Radiation Protection Biological Safety Cabinet</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BSC-1500IIA2-R BSC-1800IIA2-R</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
<p><strong>Features:</strong><br />
1. Color key display: super large screen, more clearly and dynamically display the values of the safety cabinet, and has the function of reservation timing.</p>
<p>2. Automatic adjustment of wind speed.</p>
<p>3. With power failure memory function, the state before power failure is restored after power-on, and there is a visual warning.</p>
<p>4. Operation area integrated molding design, easy to disassemble and clean.</p>
<p>5. Separate the cabinet from the base. Adjustable base height can be customized.</p>
<p>6. Interlocking function: UV lamp and front window; UV lamp and fan; Fan and front window.</p>
<p>7. With the reservation timing function, it can automatically set the safety cabinet regular startup, shutdown and UV lamp, fan, socket operation time.</p>
<p>8. The front window is closed to trigger the double signal, so that the sterilization and disinfection function of the ultraviolet lamp can be opened normally.</p>
<p>9. The negative pressure air duct is equipped with a foreign body filtering structure to prevent foreign bodies such as paper scraps from entering the fan system and affecting the normal operation of the product.</p>
<p>10. The front window glass has a one-click lifting function</p>
<p>11. The cabinet adopts 10° tilt Angle design, which is in line with the ergonomic principle, the viewing Angle is larger, the operation is convenient and more humane.</p>
<p>12. The integrated hand shelf is changed to a large plane, and the contact area with the arm is larger and more comfortable.</p>
<p>13. The left and right sides of the work area and the bottom of the lead plate are respectively protected. The left and right sides of the work area contain a 10mm lead plate, and the bottom of the operation area is a 10mm lead plate.</p>
<p>14. The front side is equipped with a side-sliding protective screen with protective radiation window. The front of the safety cabinet contains a movable anti-radiation glass front window component, and 1 piece of anti-radiation glass has a thickness of 50mm thick *400mm wide, which can slide left and right; This component can be separated from the safety cabinet and can be removed when not in use to facilitate the placement of items in the operating area.</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BSC-1500IIA2-R</td>
<td>BSC-1800IIA2-R</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size(W*D*H)</td>
<td>1500*840*2200mm</td>
<td>1800*840*2200mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Internal Size(W*D*H)</td>
<td>1350*600*660mm</td>
<td>1625*600*660mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Tested Opening</td>
<td colspan="2">Safety height 200mm(8&#8243;)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Max Opening</td>
<td colspan="2">440mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Inflow Velocity</td>
<td colspan="2">0.53±0.025m/s</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Downflow Velocity</td>
<td colspan="2">0.33±0.025m/s</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>ULPA Filter</td>
<td colspan="2">Two, 99.9995% efficiency at 0.12μm, filter life indicator</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Front Window</td>
<td colspan="2">Motorized. Two-layer laminated toughened glass≥6mm. Anti UV</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Noise</td>
<td colspan="2">≤65dB</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="2">UV Lamp</td>
<td>40W*1</td>
<td>40W*1</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">UV timer, UV life indicator, emission of 235.7 nanometers for most efficient decontamination</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>LED lamp</td>
<td>16W*2</td>
<td>16W*2</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Illumination</td>
<td colspan="2">≥1000Lux</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Consumption</td>
<td>1600W</td>
<td>1800W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Waterproof Socket</td>
<td colspan="2">Two, total load of two sockets: 500W</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Display</td>
<td colspan="2">LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and downflow velocity, filter life, humidity and temperature, system working time etc.</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Control System</td>
<td colspan="2">Microprocessor</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Airflow System</td>
<td colspan="2">70% air recirculation, 30% air exhaust</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Visual and Audio Alarm</td>
<td colspan="2">Abnormal airflow velocity, filter replacement, front window at unsafe height, high filter pressure alarm,  abnormal power failure</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="2">Material</td>
<td colspan="2">Work Zone: 304 stainless steel</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Main Body: Cold-rolled steel with anti-bacteria powder coating</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Work Surface Height</td>
<td colspan="2">750mm(Size can be customized according to requirements)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Caster</td>
<td colspan="2">Footmaster caster</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Power Supply</td>
<td colspan="2">AC220V, 50/60Hz; 110V, 60Hz</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Standard Accessory</td>
<td colspan="2">LED lamp 2pcs, UV lamp 1pc, Base stand, Remote control, Foot switch, Drain valve, Waterproof socket 2pcs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Optional Accessory</td>
<td colspan="2">Water and gas tap, Electric height adjustable base stand, Armrest</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Gross Weight</td>
<td>350kg</td>
<td>450kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Package Size(W*D*H)</td>
<td>1630*1060*1840mm</td>
<td>1930*1060*1840mm</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/radiation-protection-biological-safety-cabinet/">Radiation Protection Biological Safety Cabinet</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Class II A2 Biological Safety Cabinet NSF Certified</title>
		<link>https://keylaser.am/product/class-ii-a2-biological-safety-cabinet-nsf-certified/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 07 Oct 2024 14:44:45 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=10381</guid>

					<description><![CDATA[<p><strong>Introduction:</strong></p>
<p>The NSF Certified Class II Biosafety Cabinet is a top-tier laboratory safety enclosure designed to provide maximum protection for operators, samples, and the environment when working with moderate-risk biological agents.</p>
<p>The post <a href="https://keylaser.am/product/class-ii-a2-biological-safety-cabinet-nsf-certified/">Class II A2 Biological Safety Cabinet NSF Certified</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BSC-2FA2-NA BSC-2FA2-GL</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
<div class="ast-oembed-container " style="height: 100%;"><iframe loading="lazy" title="BIOBASE NSF Certified Class II A2 Biological Safety Cabinet BSC 2FA2 NA" width="1778" height="1000" src="https://www.youtube.com/embed/dVk--sS9Mys?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
<p>&nbsp;</p>
<div>
<p><strong>Features:</strong></p>
</div>
<p>1. Motorized front window.</p>
<p>2. 7-inch large touch color display: touch operation, real-time and clearer display of various values of the safety cabinet, dynamic air flow pattern diagram, fault alarm sound and light prompt.</p>
<p>3. The power-on password can be set to prevent mis-operation by irrelevant personnel.</p>
<p>2. EC Fan, automatically adjust the wind speed.</p>
<p>3. With power-off memory function, the state before power-off will be restored after power-on and there will be visual prompts and alarms.</p>
<p>4. The integrated design of the operation area makes it easy to disassemble and clean.</p>
<p>5. The cabinet is separated from the base. The height of the adjustable base can be customized.</p>
<p>6. Interlocking function:UV lamp and front window; UV lamp and fan; fan and front window.</p>
<p>7. It has the function of appointment timing, which can automatically set the time of starting and shutting down the safety cabinet and the running time of ultraviolet lamps, fan and sockets.</p>
<p>8. The front window closes the trigger signal, so that the sterilization and disinfection function of the ultraviolet lamp is normally turned on.</p>
<p>9. The one-piece hand resting surface has a larger contact area with the arm and is more comfortable. air speed adjustable with filter block.</p>
<p>&nbsp;</p>
<p><img loading="lazy" decoding="async" class="wp-image-10382 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/BSC-2FA2-CL-1.webp" alt="Class II A2 Biological Safety Cabinet NSF Certified" width="1209" height="554" srcset="https://keylaser.am/wp-content/uploads/2024/10/BSC-2FA2-CL-1.webp 1209w, https://keylaser.am/wp-content/uploads/2024/10/BSC-2FA2-CL-1-300x137.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/BSC-2FA2-CL-1-1024x469.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/BSC-2FA2-CL-1-768x352.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/BSC-2FA2-CL-1-600x275.webp 600w" sizes="auto, (max-width: 1209px) 100vw, 1209px" /></p>
<p><img loading="lazy" decoding="async" class="wp-image-10383 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/BSC-2FA2-CL.webp" alt="Class II A2 Biological Safety Cabinet NSF Certified" width="306" height="527" srcset="https://keylaser.am/wp-content/uploads/2024/10/BSC-2FA2-CL.webp 306w, https://keylaser.am/wp-content/uploads/2024/10/BSC-2FA2-CL-174x300.webp 174w" sizes="auto, (max-width: 306px) 100vw, 306px" /></p>
<p>&nbsp;</p>
<table border="1" width="882">
<tbody>
<tr class="firstRow">
<td rowspan="2" valign="center" width="245">Model</td>
<td valign="center" width="594">BSC-2FA2-NA</td>
</tr>
<tr>
<td valign="center" width="814">BSC-2FA2-GL</td>
</tr>
<tr>
<td valign="center" width="257">External Size(W*D*H)</td>
<td valign="center" width="594">700*650*1920mm</td>
</tr>
<tr>
<td valign="center" width="257">Internal Size(W*D*H)</td>
<td valign="center" width="594">600*500*540mm</td>
</tr>
<tr>
<td valign="center" width="257">Work Surface Hight</td>
<td valign="center" width="594">750mm</td>
</tr>
<tr>
<td valign="center" width="257">Max Opening</td>
<td valign="center" width="594">370mm</td>
</tr>
<tr>
<td valign="center" width="257">Tested Opening</td>
<td valign="center" width="594">Safety height 254mm(10&#8243;)</td>
</tr>
<tr>
<td valign="center" width="257">Inflow</td>
<td valign="center" width="594">290m³/h (170cfm)</td>
</tr>
<tr>
<td valign="center" width="257">Downflow</td>
<td valign="center" width="594">55%: 360m³/h (211cfm)</td>
</tr>
<tr>
<td valign="center" width="257">Exhausl</td>
<td valign="center" width="594">45%: 290m³/h (170cfm)</td>
</tr>
<tr>
<td valign="center" width="257">Front Window</td>
<td valign="center" width="594">Two-layer laminated toughened glass&gt;6mm, Anti UV</td>
</tr>
<tr>
<td valign="center" width="257">U PA Filter</td>
<td valign="center" width="594">≥99.9995% efficiency at 0.12μm</td>
</tr>
<tr>
<td valign="center" width="257">Filter Guard Type</td>
<td valign="center" width="594">Aluminum alloy frame</td>
</tr>
<tr>
<td valign="center" width="257">Noise</td>
<td valign="center" width="594">NSF 49≤67dB</td>
</tr>
<tr>
<td valign="center" width="257">Ilumination</td>
<td valign="center" width="594">≥1000Lux</td>
</tr>
<tr>
<td valign="center" width="257">Display</td>
<td valign="center" width="594">Capacitive touch screen</td>
</tr>
<tr>
<td valign="center" width="257">Waterproof Socket</td>
<td valign="center" width="594">Two, total consumption≤500W</td>
</tr>
<tr>
<td valign="center" width="257">Ground Resistance</td>
<td valign="center" width="594">≤0.1Ω</td>
</tr>
<tr>
<td valign="center" width="257">Power Supply</td>
<td valign="center" width="594">AC230V, 50/60Hz; AC115V, 60Hz, Full load Amps: 9A, BTU/Hr: 1689</td>
</tr>
<tr>
<td valign="center" width="257">Consumption</td>
<td valign="center" width="594">≤500W</td>
</tr>
<tr>
<td valign="center" width="257">Alarn</td>
<td valign="center" width="594">Abnormal airlow velocity; Filter replacement; Front window at unsafe height</td>
</tr>
<tr>
<td valign="center" width="257">Motor</td>
<td valign="center" width="594">One EC fan, 115V&amp;230V acceptable, Speed adjustable, High efficiency and low power consumplion</td>
</tr>
<tr>
<td rowspan="2" valign="center" width="257">Material</td>
<td valign="center" width="594">Working area: 304 stainless steel</td>
</tr>
<tr>
<td valign="center" width="814">Frame and decoratve plate: cold-rolled steel with anti-bacteria power coating</td>
</tr>
<tr>
<td valign="center" width="257">UV Lamp</td>
<td valign="center" width="594">15W</td>
</tr>
<tr>
<td valign="center" width="257">LED  Lamp</td>
<td valign="center" width="594">10W*2</td>
</tr>
<tr>
<td valign="center" width="257">Standard Accessory</td>
<td valign="center" width="594">LED Lamp*2, UV lamp*2, Base stand, Drain valve, Waterproof sockets, Remote control</td>
</tr>
<tr>
<td valign="center" width="257">Optional Accessory</td>
<td valign="center" width="594">Armrest, Airlow tester, Formalin fumigation sterlizer, Infrared sterlizer, Remote control, SS water tap*1&amp;gas tap*1</td>
</tr>
<tr>
<td valign="center" width="257">Net Weight</td>
<td valign="center" width="594">150kg</td>
</tr>
<tr>
<td valign="center" width="257">Package Size(W*D*H)</td>
<td valign="center" width="594">Carton: 820*910*1500mm</td>
</tr>
<tr>
<td valign="center" width="257">Gross Weight</td>
<td valign="center" width="594">190kg</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://keylaser.am/product/class-ii-a2-biological-safety-cabinet-nsf-certified/">Class II A2 Biological Safety Cabinet NSF Certified</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Double-side Class II A2 Biological Safety Cabinet</title>
		<link>https://keylaser.am/product/double-side-class-ii-a2-biological-safety-cabinet/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 07 Oct 2024 14:37:38 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=10375</guid>

					<description><![CDATA[<p><strong>Introduction:</strong></p>
<p>Biosafety cabinet is a box-type air purification negative pressure safety device that can prevent the aerosol escape of some dangerous or unknown biological particles in the process of experimental operation. It is widely used in scientific research, teaching, clinical testing and production in the fields of microbiology, genetic engineering and biological products, and is the most basic safety protection equipment in the first-level protective barrier of laboratory biosafety.</p>
<p>The post <a href="https://keylaser.am/product/double-side-class-ii-a2-biological-safety-cabinet/">Double-side Class II A2 Biological Safety Cabinet</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BSC-1500IIA2-S</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
<div class="ast-oembed-container " style="height: 100%;"><iframe loading="lazy" title="BSC-1500IIA2-S Double-side Class II A2 Biological Safety Cabinet" width="1778" height="1000" src="https://www.youtube.com/embed/hwpHlTEp3Fw?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
<p>&nbsp;</p>
<p><strong>Features:</strong></p>
<p>1. There are two front openings for easy operation, which can be operated by two people at the same time.</p>
<p>2. It is convenient for the installation and replacement of high-efficiency filters.</p>
<p>3. The cabinet is designed with an inclined angle, which conforms to the principle of ergonomics and has a larger viewing angle.</p>
<p>4. The working area adopts a negative pressure surround design, which is safer.</p>
<p>5. The workbench adopts a basin-shaped design, even if the waste liquid overflows in the experiment, it will not flow into the liquid accumulation tank, which is easy to clean.</p>
<p>6. The integrated design of casters and brackets can be fixed and leveled by adjusting the legs of the casters.</p>
<p>7. The cabinet and bracket can be separated, and the height of the bracket can be customized.</p>
<p>8. The maintenance and replacement of the filter and fan of the safety cabinet can be carried out at the front side of the safety cabinet, which is more convenient.</p>
<p>9. The glass adopts double-layer laminated explosion-proof safety glass, even if the glass is broken, it will not hurt people.</p>
<p>10. 7-inch touch screen, displaying the dynamics of airflow, downflow velocity, inflow velocity, temperature, humidity, clock, resistance of supply and exhaust filters.</p>
<p>11. Power-off recovery function: key memory function, fan, sunlight, lighting with power-off memory function.</p>
<p>12. Screen lock function: touch the lock screen button, the operation interface is locked, and other function keys are locked at the same time.</p>
<p>13. It has the timer switch function of fan, ultraviolet and socket, and the timer shutdown function; it saves working time.</p>
<p>14. User password modification, the user can set the power-on password of the safety cabinet.</p>
<p>15. Through the selection of high-quality fans and high-efficiency filters, and the reasonable design of the air duct structure, the air velocity of the biological safety cabinet must meet the requirements.</p>
<figure id="attachment_10377" aria-describedby="caption-attachment-10377" style="width: 727px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-10377 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/BSC-1500IIA2-S.webp" alt="Double-side Class II A2 Biological Safety Cabinet" width="727" height="383" srcset="https://keylaser.am/wp-content/uploads/2024/10/BSC-1500IIA2-S.webp 727w, https://keylaser.am/wp-content/uploads/2024/10/BSC-1500IIA2-S-300x158.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/BSC-1500IIA2-S-600x316.webp 600w" sizes="auto, (max-width: 727px) 100vw, 727px" /><figcaption id="caption-attachment-10377" class="wp-caption-text"> </figcaption></figure>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BSC-1500IIA2-S</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size(W*D*H)</td>
<td>1500*785*2220mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Internal Size(W*D*H)</td>
<td>1220*700*660mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Tested Opening</td>
<td>Safety height 200mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Max Opening</td>
<td>450mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Inflow Velocity</td>
<td>0.48±0.025m/s</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Downflow Velocity</td>
<td>0.33±0.025m/s</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>ULPA Filter</td>
<td>Two, 99.9995% efficiency at 0.12μm, filter life indicator</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Front Window</td>
<td>Two-layer laminated toughened glass≥5mm. Anti UV.</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Noise</td>
<td>≤67dB</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>UV Lamp</td>
<td>15W*2</p>
<p>UV timer, UV life indicator, emission of 253.7 nanometers for most efficient decontamination</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>LED Lamp</td>
<td>16W*2</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Illumination</td>
<td>≥1000Lux</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Consumption</td>
<td>1300W</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Socket</td>
<td>Two, total consumption: 500W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Display</td>
<td>LCD display</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Control System</td>
<td>70% air recirculation, 30% air exhaust</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Visual and Audio Alarm</td>
<td>Filter replacement, window over height, abnormal air flow velocity; High filter pressure alarm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Material</td>
<td>Work Zone: 304 stainless steel</p>
<p>Main Body: Cold-rolled steel with anti-bacteria powder coating</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Work Surface Height</td>
<td>750mm with base stand</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Power Supply</td>
<td>AC220V, 50/60Hz; 110V, 60Hz</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Standard Accessory</td>
<td>Cabinet*1, Base stand*1, Fan*1, Supply filter*1, Exhaust filter*1, LED lamp*2, UV lamp*2, Drain ball valve*1, Socket*2</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Optional Accessory</td>
<td>Arm rest, Formalin fumigation sterilizer, Infrared sterilizer, S.S. water tap, S.S. gas tap</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size(W*D*H)</td>
<td>1770*930*1850mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>325kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/double-side-class-ii-a2-biological-safety-cabinet/">Double-side Class II A2 Biological Safety Cabinet</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>NSF Certified Class II A2 Biological Safety Cabinet BSC-2FA2</title>
		<link>https://keylaser.am/product/nsf-certified-class-ii-a2-biological-safety-cabinet-bsc-2fa2/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 07 Oct 2024 14:12:09 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=10366</guid>

					<description><![CDATA[<p>The cabinet is separated from the base. The height of the adjustable base can be customized.</p>
<p>The post <a href="https://keylaser.am/product/nsf-certified-class-ii-a2-biological-safety-cabinet-bsc-2fa2/">NSF Certified Class II A2 Biological Safety Cabinet BSC-2FA2</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BSC-2FA2</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
<p><strong>ADVANTAGE</strong></p>
<p>1. Motorized front window.</p>
<p>2. 7-inch large touch color display: touch operation, real-time and clearer display of various values of the safety cabinet, dynamic air flow pattern diagram, fault alarm sound and light prompt.</p>
<p>3. The power-on password can be set to prevent mis-operation by irrelevant personnel.</p>
<p>2. EC Fan, automatically adjust the wind speed.</p>
<p>3. With power-off memory function, the state before power-off will be restored after power-on and there will be visual prompts and alarms.</p>
<p>4. The integrated design of the operation area makes it easy to disassemble and clean.</p>
<p>5. The cabinet is separated from the base. The height of the adjustable base can be customized.</p>
<p>6. Interlocking function: UV lamp and front window; UV lamp and fan; fan and front window.</p>
<p>7. It has the function of appointment timing, which can automatically set the time of starting and shutting down the safety cabinet and the running time of ultraviolet lamps, fan and sockets.</p>
<p>8. The front window closes the trigger signal, so that the sterilization and disinfection function of the ultraviolet lamp is normally turned on.</p>
<p>9. The one-piece hand resting surface has a larger contact area with the arm and is more comfortable.air speed adjustable with filter block.</p>
<p>&nbsp;</p>
<p><strong>TECHNICAL PARAMETERS</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="866">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td width="161">Model</td>
<td width="704">BSC-2FA2</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="161">External Size（W*D*H）</td>
<td width="704">700*650*1920mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="161">Internal Size（W*D*H）</td>
<td width="704">600*500*540mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="161">Work Surface Hight</td>
<td width="704">750mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="161">Max Opening</td>
<td width="704">370mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="161">Tested Opening</td>
<td width="704">Safety height 254mm（10&#8243;）</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="161">Inflow</td>
<td width="704">290m³/h  (170cfm）</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="161">Downflow</td>
<td width="704">55%: 360m³/h  (211cfm）</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="161">Exhaust</td>
<td width="704">45%: 290m³/h  (170cfm）</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="161">Front Window</td>
<td width="704">Two-layer laminated toughened glass&gt;6mm, Anti UV</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="161">ULPA Filter</td>
<td width="704">≥99.9995% efficiency at 0.12μm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="161">Filter Guard Type</td>
<td width="704">Aluminum alloy frame</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="161">Noise</td>
<td width="704">NSF 49≤67 dB</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="161">Illumination</td>
<td width="704">≥1000Lux</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="161">Display</td>
<td width="704">Capacitive touch screen</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="161">Waterproof Socket</td>
<td width="704">Two, Total consumption≤500W</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="161">Ground Resistance</td>
<td width="704">≤0.1Ω</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="161">Power Supply</td>
<td width="704">AC230V, 50/60Hz; AC115V, 60Hz, Full load Amps: 9A, BTU/Hr: 1689</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="161">Consumption</td>
<td width="704">≤500W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="161">Alarm</td>
<td width="704">Abnormal airflow velocity; Filter replacement; Front window at unsafe height</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="161">Motor</td>
<td width="704">One EC fan, 115V＆230V acceptable, Speed adjustable, High efficiency and low power consumption</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="161">Material</td>
<td width="704">Working area: 304 stainless steel</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="161">UV Lamp</td>
<td width="704">Frame and Decorative Plate: cold-rolled steel with anti-bacteria power coating</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="161">LED Lamp</td>
<td width="704">15W</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="161">Standard Accessory</td>
<td width="704">10W*2</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="161">Optional Accessory</td>
<td width="704">LED Lamp*2, UV lamp, Base stand, Drain valve, Waterproof sockets</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="161">Net Weight</td>
<td width="704">Armrest, Airflow tester, Formalin fumigation sterilizer, Infrared sterilizer, Remote control, SS water tap*1&amp; gas tap*1</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="161">Package Size（W*D*H）</td>
<td width="704">150kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="161">Gross Weight</td>
<td width="704">Carton: 800*850*1350mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="161">External Size（W*D*H）</td>
<td width="704">170kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/nsf-certified-class-ii-a2-biological-safety-cabinet-bsc-2fa2/">NSF Certified Class II A2 Biological Safety Cabinet BSC-2FA2</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AC Series Class II B2 Biological Safety Cabinet B2-X</title>
		<link>https://keylaser.am/product/ac-series-class-ii-b2-biological-safety-cabinet-b2-x/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 07 Oct 2024 14:06:59 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=10355</guid>

					<description><![CDATA[<div><strong>Introduction:</strong></div>
<p>The AC Series Class II B2 Biological Safety Cabinet is a high-performance containment unit designed for laboratories handling hazardous biological materials and chemical compounds. Unlike traditional Class II cabinets, the B2 model provides 100% total exhaust, ensuring that all potentially harmful air is completely expelled from the laboratory, making it ideal for applications requiring both biological and chemical safety.</p>
<p>The post <a href="https://keylaser.am/product/ac-series-class-ii-b2-biological-safety-cabinet-b2-x/">AC Series Class II B2 Biological Safety Cabinet B2-X</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BSC-1100IIB2-X BSC-1300IIB2-X BSC-1500IIB2-X BSC-1800IIB2-X</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
<div class="ast-oembed-container " style="height: 100%;"><iframe loading="lazy" title="AC Series Class II B2 Biological Safety Cabinet BSC-1100 II B2-X" width="1778" height="1000" src="https://www.youtube.com/embed/AjAbzk2aV5Y?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
<p>&nbsp;</p>
<p><strong>Features:</strong><br />
1. Color key display: large screen, more clear and dynamic display of various values of the safety cabinet, and has the function of appointment timing.</p>
<p>2. Automatically adjust the wind speed.</p>
<p>3. With power-off memory function, the state before power-off will be restored after power-on, and there will be visual prompts and alarms.</p>
<p>4. The integrated design of the operation area makes it easy to disassemble and clean.</p>
<p>5. The cabinet is separated from the base. The height of the adjustable base can be customized.</p>
<p>6. Interlocking function: UV lamp and front window; UV lamp and fan, LED lamp; fan and front window.</p>
<p>7. It has the function of appointment timing, which can automatically set the time of starting and shutting down the safety cabinet and the running time of ultraviolet lamps, fans and sockets.</p>
<p>8. The front window closes the double trigger signal, so that the sterilization and disinfection function of the ultraviolet lamp is normally turned on.</p>
<p>9. The negative pressure air duct is equipped with a foreign matter filtering structure to prevent foreign matter such as paper scraps from entering the fan system and affecting the normal operation of the product.</p>
<p>10. The front window glass has a one-key lift function.</p>
<p>11. The cabinet is designed with a 10° inclination angle, which is in line with ergonomic principles, with a larger viewing angle, convenient operation and more humanization.<br />
12. The one-piece hand rest has a large fat surface, which has a larger contact area with the arm and is more comfortable.</p>
<figure id="attachment_10362" aria-describedby="caption-attachment-10362" style="width: 737px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-10362 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/BSC-11001B2.webp" alt="AC Series Class II B2 Biological Safety Cabinet B2-X" width="737" height="505" srcset="https://keylaser.am/wp-content/uploads/2024/10/BSC-11001B2.webp 737w, https://keylaser.am/wp-content/uploads/2024/10/BSC-11001B2-300x206.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/BSC-11001B2-600x411.webp 600w" sizes="auto, (max-width: 737px) 100vw, 737px" /><figcaption id="caption-attachment-10362" class="wp-caption-text"> </figcaption></figure>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td colspan="2">Model</td>
<td>BSC-1100IIB2-X</td>
<td>BSC-1300IIB2-X</td>
<td>BSC-1500IIB2-X</td>
<td>BSC-1800IIB2-X</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">External Size(W*D*H)</td>
<td>1100*775*2250mm</td>
<td>1300*775*2250mm</td>
<td>1500*775*2250mm</td>
<td>1800*775*2250mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">Internal Size(W*D*H)</td>
<td>940*600*660mm</td>
<td>1150*600*660mm</td>
<td>1350*600*660mm</td>
<td>1625*600*660mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Tested Opening</td>
<td colspan="4">Safety height 200mm(8&#8243;)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">Max Opening</td>
<td colspan="4">480mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Inflow Velocity</td>
<td colspan="4">0.53±0.025m/s</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">Downflow Velocity</td>
<td colspan="4">0.33±0.025m/s</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">ULPA Filter</td>
<td colspan="4">Two, 99.9995% efficiency at0.12μm, filter life indicator</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">Front Window</td>
<td colspan="4">Motorized. Two-layer laminated toughened glass≥6mm. Anti UV</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Noise</td>
<td colspan="4">≤65dB</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2" rowspan="2">UV Lamp</td>
<td>30W*1</td>
<td>30W*1</td>
<td>40W*1</td>
<td>40W*1</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="4">UV timer, UV life indicator, emission of 235.7 nanometers for most efficient decontamination</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">LED Lamp</td>
<td>12W*2</td>
<td>14W*2</td>
<td>16W*2</td>
<td>16W*2</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Illumination</td>
<td colspan="4">≥1000Lux</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">Consumption</td>
<td>1300W</td>
<td>1300W</td>
<td>1300W</td>
<td>1300W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Waterproof Socket</td>
<td colspan="4">Two, total load of two sockets: 500W</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">Display</td>
<td colspan="4">LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and downflow velocity, filter life, humidity and temperature, system working time etc.</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Control System</td>
<td colspan="4">Microprocessor</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">Airflow System</td>
<td colspan="4">0% air recirculation, 100% air exhaust</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Visual and Audio Alarm</td>
<td colspan="4">Abnormal airflow velocity, Filter replacement, Front window at unsafe height, High filter pressure alarm, abnormal power failure</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2" rowspan="2">Material</td>
<td colspan="4">Work Zone: 304 stainless steel</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="4">Main Body: Cold-rolled steel with anti-bacteria powder coating</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">Work Surface Height</td>
<td colspan="3">770mm(can be customized)</td>
<td>800mm(Can be customized)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Caster</td>
<td colspan="4">Footmaster caster</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">Power Supply</td>
<td colspan="4">AC220V, 50/60Hz; 110V, 60Hz</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Standard Accessory</td>
<td colspan="4">LED lamp 2pcs, UV lamp 2pcs, Base stand, Remote control, Foot switch, Drain valve, Waterproof socket 2pcs, Exhaust blower, Exhaust duct</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="2">Optional Accessory</td>
<td colspan="4">Water and gas tap, Electric height adjustable base stand, Armrest</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Gross Weight</td>
<td>243kg; 52kg</td>
<td>282kg; 64kg</td>
<td>300kg; 64kg</td>
<td>408kg; 64kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="2">Package</td>
<td rowspan="2">Main Body Exhaust Blower(W*D*H)</td>
<td>1230*990*1840mm</td>
<td>1430*990*1840mm</td>
<td>1630*990*1840mm</td>
<td>1930*990*1840mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>930*800*700mm</td>
<td>930*860*740mm</td>
<td>930*860*740mm</td>
<td>930*860*740mm</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/ac-series-class-ii-b2-biological-safety-cabinet-b2-x/">AC Series Class II B2 Biological Safety Cabinet B2-X</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AC Series Class II A2 Biological Safety Cabinet BSC-700IIA2-Z</title>
		<link>https://keylaser.am/product/ac-series-class-ii-a2-biological-safety-cabinet-bsc-700iia2-z/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 07 Oct 2024 13:56:57 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=10348</guid>

					<description><![CDATA[<div><strong>Introduction:</strong></div>
<div>Biological safety cabinet is a box-type air purification negative pressure safety device that can prevent the aerosol escape of some dangerous or unknown biological particles in the process of experimental operation. It is widely used in scientific research, teaching, clinical testing and production in the fields of microbiology, genetic engineering and biological products, and is the most basic safety protection equipment in the first-level protective barrier of laboratory biosafety.</div>
<p>The post <a href="https://keylaser.am/product/ac-series-class-ii-a2-biological-safety-cabinet-bsc-700iia2-z/">AC Series Class II A2 Biological Safety Cabinet BSC-700IIA2-Z</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BSC-700IIA2-Z</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
<p><img loading="lazy" decoding="async" class="wp-image-10350 size-full" style="font-style: inherit; font-weight: 600;" src="https://keylaser.am/wp-content/uploads/2024/10/13-14-AC-Series-Class-II-A2-Biological-Safety-Cabinet-BSC-700-II-A2-Z.jpg" alt="AC Series Class II A2 Biological Safety Cabinet BSC-700 II A2-Z" width="2516" height="1719" srcset="https://keylaser.am/wp-content/uploads/2024/10/13-14-AC-Series-Class-II-A2-Biological-Safety-Cabinet-BSC-700-II-A2-Z.jpg 2516w, https://keylaser.am/wp-content/uploads/2024/10/13-14-AC-Series-Class-II-A2-Biological-Safety-Cabinet-BSC-700-II-A2-Z-300x205.jpg 300w, https://keylaser.am/wp-content/uploads/2024/10/13-14-AC-Series-Class-II-A2-Biological-Safety-Cabinet-BSC-700-II-A2-Z-1024x700.jpg 1024w, https://keylaser.am/wp-content/uploads/2024/10/13-14-AC-Series-Class-II-A2-Biological-Safety-Cabinet-BSC-700-II-A2-Z-768x525.jpg 768w, https://keylaser.am/wp-content/uploads/2024/10/13-14-AC-Series-Class-II-A2-Biological-Safety-Cabinet-BSC-700-II-A2-Z-1536x1049.jpg 1536w, https://keylaser.am/wp-content/uploads/2024/10/13-14-AC-Series-Class-II-A2-Biological-Safety-Cabinet-BSC-700-II-A2-Z-2048x1399.jpg 2048w, https://keylaser.am/wp-content/uploads/2024/10/13-14-AC-Series-Class-II-A2-Biological-Safety-Cabinet-BSC-700-II-A2-Z-600x410.jpg 600w" sizes="auto, (max-width: 2516px) 100vw, 2516px" /></p>
<p><strong>Features:</strong><br />
1. Color key display: large screen, more clear and dynamic display of various values of the safety cabinet, and has the function of appointment timing.<br />
2. Automatically adjust the wind speed.<br />
3. With power-off memory function, the state before power-off will be restored after power-on, and there will be visual prompts and alarms.<br />
4. The integrated design of the operation area makes it easy to disassemble and clean.<br />
5. The cabinet is separated from the base. The height of the adjustable base can be customized.<br />
6. Interlocking function: UV lamp and front window, UV lamp and fan, LED lamp, fan and front window.<br />
7. It has the function of appointment timing, which can automatically set the time of starting and shutting down the safety cabinet and the running time of ultraviolet lamps, fans and sockets.<br />
8. The front window closes the double trigger signal, so that the sterilization and disinfection function of the ultraviolet lamp is normally turned on.<br />
9. The negative pressure air duct is equipped with a foreign matter filtering structure to prevent foreign matter such as paper scraps from entering the fan system and affecting the normal operation of the product.<br />
10. The front window glass has a one-key lift function.<br />
11. The one-piece hand resting surface has a larger contact area with the arm and is more comfortable.</p>
<p>&nbsp;</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="882">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td width="210">Model</td>
<td width="630">BSC-700IIA2-Z</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="208">External Size(W*D*H)</td>
<td width="630">700*650*1920mm(700*650*1280mm without base stand)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="209">Internal Size(W*D*H)</td>
<td width="630">600*500*540mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="210">Tested Opening</td>
<td width="630">Safety height 200mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="210">Max Opening</td>
<td width="630">380mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="210">Inflow Velocity</td>
<td width="630">0.53±0.025m/s</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="210">Down Flow Velocity</td>
<td width="630">0.33±0.025m/s</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="210">ULPA Filter</td>
<td width="630">Two, 99.9995% efficiency at 0.12μm, filter life indicator</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="210">Front Window</td>
<td width="630">Motorized</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="210">Noise</td>
<td width="630">≤65dB</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="210">UV Lamp</td>
<td width="630">15W*1</p>
<p>UV timer, UV life indicator, emission of 253.7 nanometers for most efficient decontamination</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="210">LED Lamp</td>
<td width="630">8W*2</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="210">Illumination</td>
<td width="630">≥1000Lux</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="210">Consumption</td>
<td width="630">≤500W</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="210">Socket</td>
<td width="630">Two, total load of two sockets: 500W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="210">Display</td>
<td width="630">LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and downflow velocity, filter life, humidity and temperature, system working time, etc</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="210">Control System</td>
<td width="630">70% air recirculation, 30% air exhaust</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="210">Visual and Audio Alarm</td>
<td width="630">Filter replacement, window over height, abnormal air flow velocity, high filter pressure alarm, abnormal power failure</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="210">Material</td>
<td width="630">Work Zone: 304 stainless steel</p>
<p>Main Body: Cold-rolled steel with anti-bacteria power coating</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="210">Work Surface Height</td>
<td width="630">750mm with base stand</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="210">Power Supply</td>
<td width="630">AC220V, 50/60Hz; 110V, 60Hz</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="210">Standard Accessory</td>
<td width="630">Cabinet*1, LED lamp*2, UV lamp*2, Remote control, Drain valve*1, Waterproof socket*2, Foot swith</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="210">Optional Accessory</td>
<td width="630">Water and gas tap, Electric height adjustable base stand, Armrest, Base stand*1</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="210">Package Size(W*D*H)</td>
<td width="630">Carton: 820*910*1500mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="210">Gross Weight</td>
<td width="630">165kg(145kg without base stand)</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>&nbsp;</p>
<p>The post <a href="https://keylaser.am/product/ac-series-class-ii-a2-biological-safety-cabinet-bsc-700iia2-z/">AC Series Class II A2 Biological Safety Cabinet BSC-700IIA2-Z</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>