<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>biosafety cabinet Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-tag/biosafety-cabinet/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-tag/biosafety-cabinet/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Mon, 07 Oct 2024 16:01:55 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>biosafety cabinet Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-tag/biosafety-cabinet/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Multi-functional Workstation</title>
		<link>https://keylaser.am/product/multi-functional-workstation/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 07 Oct 2024 15:58:09 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=10424</guid>

					<description><![CDATA[<p><strong>Introduction:</strong><br />
The Mini PCR Workstation is the world's exclusive nucleic acid detection workstation, specially developed for fever clinics and small clinical laboratories. Integrate traditional PCR laboratory functions into one device. Allow more small laboratories to have PCR detection capabilities.</p>
<p>The post <a href="https://keylaser.am/product/multi-functional-workstation/">Multi-functional Workstation</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>PCR1600 PCR2100 PCR2500</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
<p><strong>Features:</strong></p>
<p>1. Global exclusive.</p>
<p>2. Small dimension, save space, economical and convenient.</p>
<p>3. Automatic air speed adjustable with filter block.</p>
<p>4. With memory function in case of power-failure.</p>
<p>5. Interlock function: UV lamp and front window, UV lamp and blower, fluorescent lamp, blower and front window.</p>
<p>6. Audio and visual alarm: Filter replacement, window over height, abnormal air flow velocity etc.</p>
<p>7. Time reserve function: This can set the UV lamp and fan working time.</p>
<p><img fetchpriority="high" decoding="async" class="wp-image-10428 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/PCR1600.webp" alt="Multi-functional Workstation" width="1072" height="499" srcset="https://keylaser.am/wp-content/uploads/2024/10/PCR1600.webp 1072w, https://keylaser.am/wp-content/uploads/2024/10/PCR1600-300x140.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/PCR1600-1024x477.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/PCR1600-768x357.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/PCR1600-600x279.webp 600w" sizes="(max-width: 1072px) 100vw, 1072px" /> <img decoding="async" class="wp-image-10427 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/PCR.webp" alt="Multi-functional Workstation" width="946" height="519" srcset="https://keylaser.am/wp-content/uploads/2024/10/PCR.webp 946w, https://keylaser.am/wp-content/uploads/2024/10/PCR-300x165.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/PCR-768x421.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/PCR-600x329.webp 600w" sizes="(max-width: 946px) 100vw, 946px" /></p>
<p><strong>Reagent Preparation Area:</strong></p>
<p>Positive pressure, vertical laminar flow design, equipped with primary filter and HEPA filter, which can protect the reagent preparation from external pollution and protect the reagent.</p>
<p><strong>Specimen Preparation Area:</strong></p>
<p>Negative pressure, the air inlet is through the front window glass door, the bottom of the operation area is returned to the air, and the top is exhausted, the upper and lower two HEPA filters are equipped to protect personnel from harmful aerosol infection and protect samples from external pollution.</p>
<p><strong>Amplification Analysis Area:</strong></p>
<p>Negative pressure, the air inlet is through the front window glass door, the bottom of the operation area is returnedto the air, and the top is exhausted, and the HEPA filter can protect both the personnel and the environment.</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td colspan="2">Model</td>
<td>PCR1600</td>
<td>PCR2100</td>
<td>PCR2500</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">External Size(L*W*H)mm</td>
<td>1600*710*2100</td>
<td>2100*710*2000</td>
<td>2500*850*2100</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="5">Reagent Preparation Area</td>
<td>Operating Area Size(L*W*H)mm</td>
<td>440*560*510</td>
<td>640*560*510</td>
<td>640*710*610</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Pressure</td>
<td colspan="3">Positive</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Airflow Velocity(m/s)</td>
<td colspan="3">0.3~0.45</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Airflow Volume(m3/h)</td>
<td>190~290</td>
<td>290~430</td>
<td>380~560</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Exhaust Type</td>
<td colspan="3">/</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="5">Specimen Preparation Area</td>
<td>Operating Area Size(L*W*H)mm</td>
<td>560*560*510</td>
<td>660*560*510</td>
<td>1060*710*610</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Pressure</td>
<td colspan="3">Negative</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Airflow Velocity(m/s)</td>
<td colspan="3">Downflow: 0.33±0.025</p>
<p>Inflow: 0.53±0.025</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Airflow Volume(m3/h)</td>
<td>210</td>
<td>250</td>
<td>400</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Exhaust Type</td>
<td colspan="3">Type A2, 30% exhaust, 70% recirculation</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="5">Amplification Analysis Area</td>
<td>Operating Area Size(L*W*H)mm</td>
<td>440*560*510</td>
<td>640*560*510</td>
<td>640*710*610</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Pressure</td>
<td colspan="3">Negative</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Airflow Velocity(m/s)</td>
<td colspan="3">≥0.4</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Airflow Volume(m3/h)</td>
<td>≥160</td>
<td>≥180</td>
<td>≥180</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Exhaust Type</td>
<td>100% exhaust</td>
<td>100% exhaust</td>
<td>100% exhaust</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>ULPA Filter</td>
<td colspan="4">Four, 99.999% efficiency at 0.12μm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Clean Level</td>
<td colspan="2">Class 100(IS0 Class 5)</td>
<td colspan="2">Class 100, Except Amplification Analysis Area</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Front Window</td>
<td colspan="4">Manual, toughened glass, anti UV</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Max Opening</td>
<td colspan="3">400mm</td>
<td>480mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Noise</td>
<td colspan="4">≤67dB(A)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Vibration</td>
<td colspan="4">≤5μm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>UV Lamp</td>
<td colspan="2">8W*3, UV timer, UV life indicator</td>
<td>15W*3</td>
<td>30W*1, 15W*2</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>LED Lamp</td>
<td colspan="2">4W*6</td>
<td>8W*6</td>
<td>8W*4, 12W*2</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Illumination(lx)</td>
<td colspan="2">≥500( Each area)</td>
<td colspan="2">≥650(Each area)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sockets</td>
<td colspan="4">The load of two sockets(Each area): 500W, total 6 sockets</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Display</td>
<td colspan="4">Touch screen</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Control System</td>
<td colspan="4">Microprocessor</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Visual and Audio Alarm</td>
<td colspan="4">Filter replacement, window over height, abnormal air flow velocity</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Work Surface Height</td>
<td colspan="4">750mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Material</td>
<td colspan="4">Work Zone: 304 stainless steel</p>
<p>Main Body: Cold-rolled steel with anti-bacteria powder coating</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Power Supply</td>
<td colspan="4">AC220V±10%, 50/60Hz; 110V±10%, 60Hz</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Consumption</td>
<td colspan="3">600W, total 2100W(With load)</td>
<td>1000W, total 2500W</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Standard Accessory</td>
<td colspan="4">LED lamp*6, UV lamp*4, Windproof plate*2(Only for PCR2100/2500), Waterproof sockets*6</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size(W*D*H)mm</td>
<td colspan="2">1750*980*1400</td>
<td>2250*980*1400</td>
<td>2650*1120*1500</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td colspan="2">400kg</td>
<td>450kg</td>
<td>500kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p><strong>Multifunctional Workstation Product List</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index1">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Item</td>
<td>Name</td>
<td>Model</td>
<td>Quantity</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="9">Reagent Preparation Area</td>
<td>Pipette</td>
<td>0.5~10μl</td>
<td>1</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Pipette</td>
<td>10~100μl</td>
<td>1</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Pipette</td>
<td>100~1000μl</td>
<td>1</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Centrifuge</td>
<td>MINI-7</td>
<td>1</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Mixer</td>
<td>BJPX-VW</td>
<td>1</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Tips</td>
<td>10μl, 100μl, 1000μl</td>
<td>/</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Centrifuge tube</td>
<td>1.5ml</td>
<td>/</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>8-strip tube</td>
<td>0.2ml</td>
<td>/</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>QPCR kit</td>
<td>Covid-19</td>
<td>/</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="9">Specimen Preparation Area</td>
<td>Pipette</td>
<td>0.5~10μl</td>
<td>1</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Pipette</td>
<td>10~100μl</td>
<td>1</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Pipette</td>
<td>100~1000μl</td>
<td>1</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Disposable virus sampling collector(One step method)</td>
<td>/</td>
<td>/</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Tips</td>
<td>10μl, 100μl, 1000μl</td>
<td>/</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Centrifuge tube</td>
<td>1.5ml</td>
<td>/</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Centrifuge</td>
<td>MINI-7</td>
<td>1</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Mixer</td>
<td>BJPX-VW</td>
<td>1</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Nucleic acid extraction system(only for PCR2500)</td>
<td>BNP32 or BNP8</td>
<td>1</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Amplification Analysis Area</td>
<td>QPCR</td>
<td>LEIA-X4</td>
<td>1</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Other Related Equipment</td>
<td>Biosafety transport box</td>
<td>BTB-L5</td>
<td>1</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>-25℃ freezer</td>
<td>BDF-25V270</td>
<td>1</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>-86℃ freezer</td>
<td>BDF-86V158</td>
<td>1</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/multi-functional-workstation/">Multi-functional Workstation</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PCR Cabinet</title>
		<link>https://keylaser.am/product/pcr-cabinet/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 07 Oct 2024 15:55:23 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=10416</guid>

					<description><![CDATA[<p>                       LED Display                                                             Waterproof Socket LED display(not including PCR-1000,                   [&#8230;]</p>
<p>The post <a href="https://keylaser.am/product/pcr-cabinet/">PCR Cabinet</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" class=" lazyloaded" src="http://www.biobase.cc/sys_manager/Images/proImg/20160702115112_1853.jpg" alt="" data-original="http://www.biobase.cc/sys_manager/Images/proImg/20160702115112_1853.jpg" />                      <img decoding="async" class=" lazyloaded" src="http://www.biobase.cc/sys_manager/Images/proImg/20160702115123_2889.jpg" alt="" data-original="http://www.biobase.cc/sys_manager/Images/proImg/20160702115123_2889.jpg" /></p>
<p><strong>LED Display           </strong>                                        <strong>          Waterproof Socket</strong><br />
LED display(not including PCR-1000,                         2 waterproof sockets are located in the back wall,</p>
<p>PCR-1000&#8217;s display is LED)                                        for optimum convenience of using small devices inside</p>
<p>the cabinet.</p>
<p><img decoding="async" class=" lazyloaded" src="http://www.biobase.cc/sys_manager/Images/proImg/20160702115131_8644.jpg" alt="" data-original="http://www.biobase.cc/sys_manager/Images/proImg/20160702115131_8644.jpg" />                      <img decoding="async" class=" lazyloaded" src="http://www.biobase.cc/sys_manager/Images/proImg/20160702115140_2059.jpg" alt="" data-original="http://www.biobase.cc/sys_manager/Images/proImg/20160702115140_2059.jpg" /><br />
<strong>UV Lamp                                                               Side Glass Window</strong><br />
Emission of 253.7 nanometers for most                   Side glass windows maximize light and visibility</p>
<p>efficient decontamination.                                       inside the cabinet, providing a bright and open</p>
<p>working environment.</p>
<p><img decoding="async" class=" lazyloaded" src="http://www.biobase.cc/sys_manager/Images/proImg/20160702115147_0863.jpg" alt="" data-original="http://www.biobase.cc/sys_manager/Images/proImg/20160702115147_0863.jpg" /><br />
<strong>Shelf with IV bar      </strong></p>
<p>Air Pattern</p>
<p><img decoding="async" class=" lazyloaded" src="http://www.biobase.cc/sys_manager/Images/proImg/20160702115249_5269.jpg" alt="" data-original="http://www.biobase.cc/sys_manager/Images/proImg/20160702115249_5269.jpg" /></p>
<p><strong>ADVANTAGE:</strong></p>
<p>1. LED display(LED display for PCR1000).</p>
<p>2. UV sterilization system.</p>
<p>3. HEPA filter efficiency 99.999% at 0.3μm.</p>
<p>4. Interlock function: UV lamp only can be switched on when the front window is closed, ensuring operator safety.</p>
<p>5. UV timer (0-90 minutes): When the setting time expires, the UV lamp automatically switches off in preparation</p>
<p>for the next experiment.</p>
<p><strong>Models:</strong></p>
<p>&nbsp;</p>
<p>TECHNICAL PARAMETERS:</p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="firstRow">
<td>Model</td>
<td>PCR-800</td>
<td>PCR-1000</td>
<td>PCR-1200</td>
<td>PCR-1300</td>
<td>PCR-1500</td>
</tr>
<tr>
<td>External Size (W*D*H)</td>
<td>800*700</p>
<p>*1770mm</td>
<td>1000*705</p>
<p>*1770mm</td>
<td>1200*700</p>
<p>*1770mm</td>
<td>1300*700</p>
<p>*1770mm</td>
<td>1500*700</p>
<p>*1770mm</td>
</tr>
<tr>
<td>Internal Size (W*D*H)</td>
<td>700*595</p>
<p>*550mm</td>
<td>900*595</p>
<p>*560mm</td>
<td>1100*595</p>
<p>*550mm</td>
<td>1200*595</p>
<p>*550mm</td>
<td>1400*595</p>
<p>*550mm</td>
</tr>
<tr>
<td>Work Surface Height</td>
<td colspan="5">750mm</td>
</tr>
<tr>
<td rowspan="2">Material</td>
<td colspan="5">Main Body: Cold-rolled steel with anti-bacteria powder coating</td>
</tr>
<tr>
<td colspan="5">Work Table: 304 stainless steel</td>
</tr>
<tr>
<td rowspan="2">Front &amp; Side Windows</td>
<td colspan="5">5mm toughened glass , anti-UV</td>
</tr>
<tr>
<td>Motorized</td>
<td>Manual</td>
<td>Motorized</td>
<td>Motorized</td>
<td>Motorized</td>
</tr>
<tr>
<td>Max Opening</td>
<td>300mm</td>
<td>320mm</td>
<td>300mm</td>
<td>300mm</td>
<td>300mm</td>
</tr>
<tr>
<td>Pre-Filter</td>
<td colspan="5">Polyester fiber, Washable</td>
</tr>
<tr>
<td>HEPA Filter</td>
<td colspan="5">99.999% efficiency at 0.3μm.</td>
</tr>
<tr>
<td>Airflow Velocity</td>
<td colspan="5">0.3-0.5m/s, speed adjustable</td>
</tr>
<tr>
<td>Noise</td>
<td colspan="5">≤65dB</td>
</tr>
<tr>
<td rowspan="2">UV Lamp</td>
<td>20W*1</td>
<td>20W*2</td>
<td>30W*1</td>
<td>30W*1</td>
<td>40W*1</td>
</tr>
<tr>
<td colspan="5">Emission of 253.7 nanometers, with UV timer</td>
</tr>
<tr>
<td>Illumination Lamp</td>
<td>LED 8W*2</td>
<td>40W*1</td>
<td colspan="3">LED 12W*2</td>
</tr>
<tr>
<td>Illumination</td>
<td colspan="5">≥1000Lux</td>
</tr>
<tr>
<td>Shelf with IV bar</td>
<td colspan="5">Stainless steel, 502*150*50mm (W*D*H)</td>
</tr>
<tr>
<td>caster</td>
<td colspan="5">Universal caster with leveling feet</td>
</tr>
<tr>
<td>Consumption</td>
<td>400W</td>
<td>300W</td>
<td>600W</td>
<td>600W</td>
<td>600W</td>
</tr>
<tr>
<td>Waterproof Socket</td>
<td colspan="5">Two, total load≤500W</td>
</tr>
<tr>
<td>Power Supply</td>
<td colspan="5">AC 220V±10%, 50/60Hz;110V±10%,60Hz</td>
</tr>
<tr>
<td>Standard Accessory</td>
<td colspan="5">UV lamp, Fluorescent lamp, Base stand, Waterproof socket*2, Shelf with IV bar</td>
</tr>
<tr>
<td>Gross Weight</td>
<td>168kg</td>
<td>178kg</td>
<td>220kg</td>
<td>231kg</td>
<td>250kg</td>
</tr>
<tr>
<td>Package Size (W*D*H)</td>
<td>960*940</p>
<p>*1450mm</td>
<td>1150*930</p>
<p>*1450mm</td>
<td>1350*930</p>
<p>*1450mm</td>
<td>1450*930</p>
<p>*1450mm</td>
<td>1650*930</p>
<p>*1450mm</td>
</tr>
</tbody>
</table>
</div>
</div>
<p><strong>Standard Accessory:</strong></p>
<p>UV lamp                              1pcs</p>
<p>Fluorescent lamp                  1pc</p>
<p>Base stand                          1pc</p>
<p>Waterproof socket               2pc</p>
<p>Shelf with IV bar                  1pc</p>
<p><strong><br />
</strong></p>
<p>The post <a href="https://keylaser.am/product/pcr-cabinet/">PCR Cabinet</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CLASS II A2 Biosafety Cabinet</title>
		<link>https://keylaser.am/product/class-ii-a2-biosafety-cabinet/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 16 Sep 2024 15:27:06 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=8847</guid>

					<description><![CDATA[<p><label>Model:</label></p>
<p>FS-600IIA2, FS-950IIA2, FS-1350IIA2, FS-1550IIA2,FS-1850IIA2</p>
<p>The post <a href="https://keylaser.am/product/class-ii-a2-biosafety-cabinet/">CLASS II A2 Biosafety Cabinet</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1. Color 7.0 inch touch screen controller</p>
<p>2. Standard with high precision thermal wind sensor</p>
<p>3. With reservation timing sterilization function, three-level authority management function, high efficiency filter, sterilization lamp service life display, built-in socket instrument controllable switch function, front window status display function, can set three position interlock function, cumulative work timing function.</p>
<p>&nbsp;</p>
<p>The post <a href="https://keylaser.am/product/class-ii-a2-biosafety-cabinet/">CLASS II A2 Biosafety Cabinet</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		