<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Clinical &amp; Analytical Instrument Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-tag/clinical-analytical-instrument/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-tag/clinical-analytical-instrument/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Mon, 23 Mar 2026 09:11:13 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>Clinical &amp; Analytical Instrument Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-tag/clinical-analytical-instrument/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Flow Cytometer BioCyte-B5R3 BioCyte-B5R3V7</title>
		<link>https://keylaser.am/product/flow-cytometer-biocyte-b5r3-biocyte-b5r3v7/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 23 Mar 2026 09:11:04 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14993</guid>

					<description><![CDATA[<p><label>Model: </label>BioCyte-B5R3 BioCyte-B5R3V7</p>
<p>Flow cytometer is a high-precision analytical and sorting instrument widely used in life sciences, medicine, immunology, and other fields. It integrates fluid mechanics, optics, electronics, and computer technology to rapidly analyze and sort individual cells (or particles) in a liquid suspension. By detecting scattered light signals and fluorescent signals from cells labeled with specific probes, the instrument can quantitatively measure multiple physical and chemical properties of cells (such as size, granularity, surface antigens, and intracellular components) at a speed of thousands to tens of thousands of cells per second, enabling high-throughput, multi-parameter, and non-destructive cellular analysis.</p>
<p>The post <a href="https://keylaser.am/product/flow-cytometer-biocyte-b5r3-biocyte-b5r3v7/">Flow Cytometer BioCyte-B5R3 BioCyte-B5R3V7</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Feature</strong><strong>s</strong><strong>:</strong></p>
<p><strong>Configuration </strong><strong>U</strong><strong>pgrade</strong></p>
<p>Up to 3 lasers and 15 fluorescent channels are configured, with a maximum of 18 detection parameters for BioCyte-B5R3V7</p>
<p><strong>Powerful </strong><strong>F</strong><strong>unction</strong></p>
<p>High resolution, high sensitivity and high stability</p>
<p><strong>Automatic</strong></p>
<p>Full-automatic detection process, synchronous collection/analysis</p>
<p><strong>Automatic </strong><strong>A</strong><strong>nalysis</strong></p>
<p>Automatic fluorescence compensation adjustment function based on database, without changing the acquisition conditions</p>
<p><strong>Absolute </strong><strong>C</strong><strong>ount</strong><strong>ing</strong></p>
<p>The absolute counting method based on the volume method of plunger pump is more accurate</p>
<p><strong>Injection </strong><strong>O</strong><strong>ptions</strong></p>
<p>The autosampler supports 40-tube Rotary/96-well microplate, which is simple and efficient</p>
<p><strong>High sensitivity and high resolution</strong></p>
<p>Fluorescence sensitivity of Rainbow calibration particles(8 peaks)</p>
<figure id="attachment_14997" aria-describedby="caption-attachment-14997" style="width: 825px" class="wp-caption alignnone"><img fetchpriority="high" decoding="async" class="wp-image-14997 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-20.webp" alt="Flow Cytometer BioCyte-B5R3 BioCyte-B5R3V7" width="825" height="805" srcset="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-20.webp 825w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-20-300x293.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-20-768x749.webp 768w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-20-600x585.webp 600w" sizes="(max-width: 825px) 100vw, 825px" /><figcaption id="caption-attachment-14997" class="wp-caption-text">Resolution of Rainbow fluorescent particles</figcaption></figure>
<figure id="attachment_15000" aria-describedby="caption-attachment-15000" style="width: 797px" class="wp-caption alignnone"><img decoding="async" class="wp-image-15000 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/02.webp" alt="Flow Cytometer BioCyte-B5R3 BioCyte-B5R3V7" width="797" height="634" srcset="https://keylaser.am/wp-content/uploads/2026/03/02.webp 797w, https://keylaser.am/wp-content/uploads/2026/03/02-300x239.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/02-768x611.webp 768w, https://keylaser.am/wp-content/uploads/2026/03/02-600x477.webp 600w" sizes="(max-width: 797px) 100vw, 797px" /><figcaption id="caption-attachment-15000" class="wp-caption-text"><strong>BioCyte</strong><strong> D</strong><strong>esign </strong><strong>I</strong><strong>nnovation</strong><br />New WDM splitter module<br />The new WDM splitter module not only reduces the number of filters used but also reduces energy loss, further improving the sensitivity of fluorescence detection.</figcaption></figure>
<figure id="attachment_14998" aria-describedby="caption-attachment-14998" style="width: 1316px" class="wp-caption alignnone"><img decoding="async" class="wp-image-14998 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-9.webp" alt="BioCyte Design InnovationNew WDM splitter module The new WDM splitter module not only reduces the number of filters used but also reduces energy loss, further improving the sensitivity of fluorescence detection." width="1316" height="536" srcset="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-9.webp 1316w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-9-300x122.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-9-1024x417.webp 1024w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-9-768x313.webp 768w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-9-600x244.webp 600w" sizes="(max-width: 1316px) 100vw, 1316px" /><figcaption id="caption-attachment-14998" class="wp-caption-text">New autosampler with mixing function<br />Highly efficient and time-saving, compatible with 40-tube rotary/96-well microplate autosampler</figcaption></figure>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-14999 size-large" src="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-800-800-8-1024x216.webp" alt="" width="1024" height="216" srcset="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-800-800-8-1024x216.webp 1024w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-800-800-8-300x63.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-800-800-8-768x162.webp 768w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-800-800-8-1536x324.webp 1536w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-800-800-8-600x126.webp 600w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-800-800-8.webp 1604w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /></p>
<p><strong>Software Features</strong></p>
<p>Chinese and English software, easy to learn and operate, can be switched freely</p>
<p>Modular design, fully automatic detection, simultaneous acquisition and analysis</p>
<p>One-click import of templates, custom editing reports based on needs</p>
<p>Automatic fluorescence compensation adjustment function, no need to change acquisition conditions</p>
<figure id="attachment_14994" aria-describedby="caption-attachment-14994" style="width: 1024px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-14994 size-large" src="https://keylaser.am/wp-content/uploads/2026/03/05-1024x585.webp" alt="Flow Cytometer BioCyte-B5R3 BioCyte-B5R3V7" width="1024" height="585" srcset="https://keylaser.am/wp-content/uploads/2026/03/05-1024x585.webp 1024w, https://keylaser.am/wp-content/uploads/2026/03/05-300x171.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/05-768x439.webp 768w, https://keylaser.am/wp-content/uploads/2026/03/05-600x343.webp 600w, https://keylaser.am/wp-content/uploads/2026/03/05.webp 1269w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /><figcaption id="caption-attachment-14994" class="wp-caption-text"><strong>BioCyte Flow Cytometer Main applicationsOncology and Hematology</strong><br />• Analysis of 6-color human peripheral blood immune cell subsets<br />• Analysis of 9-color human peripheral blood immune cell subsets<br />• Detection of dendritic cells (DC)<br />• Phenotypic characterization of natural killer cell(NK) populations<br />• Characterization of PBMC T cell receptors<br />• Detection of CD62P Platelet Activation<br /><strong>Immunology</strong><br />• Detection of T cell proliferation(CFSE)<br />• Detection of B-cell antibody class<br />• NK cell-mediated clearance of spleen cells<br />• Detection of Treg cell subsets<br /><strong>Stem </strong><strong>C</strong><strong>ells</strong><br />• Flow cytometry analysis of hematopoietic stem cells from mouse bone marrow<br />• Detection of CAR-T extracellular tumor killing<br />• Analysis of mesenchymal stem cells from bone marrow and endometrium of mice<br />• Flow cytometry analysis of mouse hematopoietic progenitor cells<br /><strong>Cell </strong><strong>B</strong><strong>iology</strong><br />• Cell activity test<br />• Cell cycle detection<br />• Cell proliferation detection<br />• Cell apoptosis detection<br /><strong>Oceanography</strong><br />• Detection of quantity, size and morphology of marine microorganisms<br />• Detection of DNA content in marine microorganisms<br />• Determination of Liposome Content in Marine Microalgae<br />• Detection of marine bacterial activity and membrane integrity<br /><strong>Environmental </strong><strong>M</strong><strong>onitoring</strong><br />• Flow cytometric detection of bacterial life and death<br />• Absolute count of virus, bacteria and algae<br />• Detection of bacterial periodic ploidy<br />• Algae classification and counting<br /><strong>Clinical</strong><br />• Lymphocyte subgroup analysis<br />• HLA-B27 detection<br />• Monocyte HLA-DR detection<br />• Detection of neutrophil CD64<br />• Regulatory T cell detection<br />• T cell activation and diseases<br />• Th1 Th2 detection<br />• Th17 cell detection<br />• Blocking Antibody Detection<br />• Cytokine detection<br />• Platelet-leukocyte adhesion<br />• Platelet autoantibody detection<br />• Platelet activation and diseases<br />• Paroxysmal nocturnal hemoglobinuria<br />• Leukemia immunotyping test<br />• Detection of residual focus of leukemia<br />• MDS immune typing<br />• Hematopoietic stem cell count<br />• Lymphoma immunotyping<br />• Detection of cell cycle and ploidy<br /><strong>Flow Cytometry Laser/Channel/Fluorochrome Configuration Table</strong><br />Laser Wavelength<br />Channel<br />Filter<br />Recommended Fluorescent Dyes<br />BioCyte-B5R3V7<br />BioCyte-B5R3<br />488nm<br />BL1<br />525/40<br />FITC, EGFP、BB515, Alexa Fluor 488<br />✓<br />✓<br />BL2<br />575/30<br />PE, DsRed<br />✓<br />✓<br />BL3<br />620/30<br />PE-Texas Red, ECD, PE-CF594, PI, 7-AAD<br />✓<br />✓<br />BL4<br />697/60<br />PerCP, PE-Cy5, PerCP-Cy5.5, PE-Cy5.5, BB700, PerCP-eFluor710<br />✓<br />✓<br />BL5<br />780/60<br />PE-Cy7, PE-Alexa Fluor 750<br />✓<br />✓<br />638nm<br />RL1<br />670/20<br />APC, Cy5, Alexa Fluor 647<br />✓<br />✓<br />RL2<br />720/40<br />APC-R700, Alexa Fluor 680, Alexa Fluor 700<br />✓<br />✓<br />RL3<br />780/60<br />APC-Cy7, APC-eFluor780, APC-H7<br />✓<br />✓<br />405nm<br />VL1<br />425/20<br />BV421<br />✓<br />VL2<br />460/40<br />Pacific Blue, V450, BV480<br />✓<br />VL3<br />525/40<br />BV51, V500<br />✓<br />VL4<br />605/40<br />BV605<br />✓<br />VL5<br />660/40<br />BV650<br />✓<br />VL6<br />720/40<br />BV711<br />✓<br />VL7<br />780/60<br />BV786, BV750<br />✓<br /><strong>Technical Parameters:</strong><br />Model<br />BioCyte-B5R3<br />BioCyte-B5R3V7<br />Software<br />English/Chinese<br />PC<br />CPU i5/16G DDR4/1T hard disk+27 inches monitor<br />Power Supply<br />AC220/110V±10%, 50/60Hz<br />External Size(W*D*H)<br />530*450*470mm<br />Net Weight<br />35kg<br />Packing Size(W*D*H)<br />Main Instrument: 860*575*720mm<br />Accessories: 860*680*810mm<br />Reagent: 380*280*320mm<br />Gross Weight<br />Main Instrument: 67kg<br />Accessories: 53.5kg<br />Reagent: 16kg<br /><strong>Recommended Reagent Information:</strong><br />Item<br />Recommended Reagent<br />Application Department<br />Lymphocyte Subset T Analysis<br />CD45<br />CD4<br />CD3<br />CD8<br />Clinical Laboratory<br />Infectious Disease Department<br />Oncology Department<br />Department of Rheumatology and Immunology<br />Department of Pediatrics Blood Specialty<br />Lymphocyte Subset T/B/NK Analysis<br />CD45<br />CD3<br />CD16<br />CD56<br />CD19<br />Absolute Count of CD4+T Lymphocyte<br />CD45<br />CD4<br />CD3<br />CD8<br />CDC (AIDS)<br />Infectious Disease Department<br />Cytokine Th1/Th2/Th17 Analysis<br />Th1: IL-2, IFN-γ, TNF-α<br />Th2: IL-4, IL-6, IL-10<br />Th17: IL-17<br />Infectious Disease Department<br />Oncology Department<br />Department of Rheumatology and Immunology<br />Department of Organ Transplantation<br />Respiratory Department<br />HLA-B27 Detection for AS<br />HLA-B27-FITC<br />HLA-B7-PE<br />IgG2a-FITC<br />IgG1-PE<br />Department of Rheumatology and Immunology<br />Orthopedics<br />DFI Analysis<br />Acridine orange (AO) Staining Solution<br />Reproductive Department<br />Infertility Department<br />Reproductive Medicine Centre</figcaption></figure>
<p>The post <a href="https://keylaser.am/product/flow-cytometer-biocyte-b5r3-biocyte-b5r3v7/">Flow Cytometer BioCyte-B5R3 BioCyte-B5R3V7</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Flow Cytometer B7H FlowCyte B7</title>
		<link>https://keylaser.am/product/flow-cytometer-b7h-flowcyte-b7/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 23 Mar 2026 08:59:31 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14987</guid>

					<description><![CDATA[<p><label>Model: </label>B7H FlowCyte B7</p>
<p>Flow cytometer is a high-precision analytical and sorting instrument widely used in life sciences, medicine, immunology, and other fields. It integrates fluid mechanics, optics, electronics, and computer technology to rapidly analyze and sort individual cells (or particles) in a liquid suspension. By detecting scattered light signals and fluorescent signals from cells labeled with specific probes, the instrument can quantitatively measure multiple physical and chemical properties of cells (such as size, granularity, surface antigens, and intracellular components) at a speed of thousands to tens of thousands of cells per second, enabling high-throughput, multi-parameter, and non-destructive cellular analysis.</p>
<p>The post <a href="https://keylaser.am/product/flow-cytometer-b7h-flowcyte-b7/">Flow Cytometer B7H FlowCyte B7</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img loading="lazy" decoding="async" class="alignnone wp-image-14990 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-18.webp" alt="Flow Cytometer B7H FlowCyte B7" width="1139" height="894" srcset="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-18.webp 1139w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-18-300x235.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-18-1024x804.webp 1024w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-18-768x603.webp 768w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-18-600x471.webp 600w" sizes="auto, (max-width: 1139px) 100vw, 1139px" /></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Item</td>
<td>Recommended Reagent</td>
<td>Application Department</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Lymphocyte Subset T Analysis</td>
<td>CD45</p>
<p>CD4</p>
<p>CD3</p>
<p>CD8</td>
<td rowspan="2">Clinical Laboratory</p>
<p>Infectious Disease Department</p>
<p>Oncology Department</p>
<p>Department of Rheumatology and Immunology</p>
<p>Department of Pediatrics Blood Specialty</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Lymphocyte Subset T/B/NK Analysis</td>
<td>CD45</p>
<p>CD3</p>
<p>CD16</p>
<p>CD56</p>
<p>CD19</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Absolute Count of CD4+T Lymphocyte</td>
<td>CD45</p>
<p>CD4</p>
<p>CD3</p>
<p>CD8</td>
<td>CDC (AIDS)</p>
<p>Infectious Disease Department</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Cytokine Th1/Th2/Th17 Analysis</td>
<td>Th1: IL-2, IFN-γ, TNF-α</p>
<p>Th2: IL-4, IL-6, IL-10</p>
<p>Th17: IL-17</td>
<td>Infectious Disease Department</p>
<p>Oncology Department</p>
<p>Department of Rheumatology and Immunology</p>
<p>Department of Organ Transplantation</p>
<p>Respiratory Department</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>HLA-B27 Detection for AS</td>
<td>HLA-B27-FITC</p>
<p>HLA-B7-PE</p>
<p>IgG2a-FITC</p>
<p>IgG1-PE</td>
<td>Department of Rheumatology and Immunology</p>
<p>Orthopedics</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>DFI Analysis</td>
<td>Acridine orange (AO) Staining Solution</td>
<td>Reproductive Department</p>
<p>Infertility Department</p>
<p>Reproductive Medicine Centre</td>
</tr>
</tbody>
</table>
</div>
</div>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index1">
<div class="inner">
<table width="882">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>FlowCyte B7H</td>
<td>FlowCyte B7</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Laser</td>
<td colspan="2">488nm solid（60mW）</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Detector</td>
<td colspan="2">FSC, SSC, FL1-FL5</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Fluorescence Channel</td>
<td colspan="2">FL1:525/50（FITC）</p>
<p>FL2:585/40（PE）</p>
<p>FL3:630/30（PE-Texas Red/ECD/PI）</p>
<p>FL4:697/60（PerCP/PE-Cy5/PE-Cy5.5）</p>
<p>FL5:780/60（PE-Cy7）</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Fluorescence Sensitivity</td>
<td colspan="2">FITC≤50 MESF, PE≤30MESF</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Fluorescence Linearity</td>
<td colspan="2">≥0.99</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>FSC Sensitivity</td>
<td colspan="2">≤1μm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Test Particle Size</td>
<td colspan="2">0.2~50μm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Carry Over</td>
<td colspan="2">≤0.5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Instrument CV</td>
<td colspan="2">FSC and all FL channel CV less than 2%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>FSC and SSC CV</td>
<td colspan="2">Can separate red blood cells and platelet, can separate white blood cells into 3 groups</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Test Speed</td>
<td colspan="2">≥46000 cells/s</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Minimum Sample Vol</td>
<td colspan="2">90μL</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Measure Range</td>
<td colspan="2">Maximum Support 10⁷</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Threshold</td>
<td colspan="2">Double threshold, minimum cells fraction</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Fluorescence Compensation</td>
<td colspan="2">Support auto online compensation, offline compensation and visualized compensation</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Item Template</td>
<td colspan="2">Support Item template, acquisition conditions/fluorescence compensation one-click use</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Intake Method</td>
<td colspan="2">Manual intake</p>
<p>Rotary wheel auto-sampling with auto-mixing function:32tests/wheel</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Liquid Storage Station</td>
<td colspan="2">Sheath bottle, waste bottle, shutdown liquid bottle 2L,</p>
<p>cleaning liquid bottle 0.5L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Software</td>
<td colspan="2">English/Chinese</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>PC</td>
<td colspan="2">Dell（CPU i5/8G DDR4/1T hard disk）+Dell 27 inches monitor</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power Supply</td>
<td colspan="2">AC220/110V±10%, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Auto-sampler</td>
<td>/</td>
<td>32-postions autosampler(Stanndard)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size(W*D*H)</td>
<td>430*500*330mm</td>
<td>650*500*330mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>30kg</td>
<td>35kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Packing Size(W*D*H)</td>
<td colspan="2">Main Instrument: 860*635*648mm</p>
<p>Accessories: 860*680*810mm</p>
<p>Reagent: 405*270*400mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td colspan="2">Main Instrument: 56kg</p>
<p>Accessories: 54kg</p>
<p>Reagent: 16kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/flow-cytometer-b7h-flowcyte-b7/">Flow Cytometer B7H FlowCyte B7</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Flow Cytometer ZS-AE7S</title>
		<link>https://keylaser.am/product/flow-cytometer-zs-ae7s/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 23 Mar 2026 08:36:02 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14980</guid>

					<description><![CDATA[<p><label>Model: </label>ZS-AE7S</p>
<p>Flow cytometer is a high-precision analytical and sorting instrument widely used in life sciences, medicine, immunology, and other fields. It integrates fluid mechanics, optics, electronics, and computer technology to rapidly analyze and sort individual cells (or particles) in a liquid suspension. By detecting scattered light signals and fluorescent signals from cells labeled with specific probes, the instrument can quantitatively measure multiple physical and chemical properties of cells (such as size, granularity, surface antigens, and intracellular components) at a speed of thousands to tens of thousands of cells per second, enabling high-throughput, multi-parameter, and non-destructive cellular analysis.</p>
<p>The post <a href="https://keylaser.am/product/flow-cytometer-zs-ae7s/">Flow Cytometer ZS-AE7S</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img loading="lazy" decoding="async" class="wp-image-14982 size-large" src="https://keylaser.am/wp-content/uploads/2026/03/MT8600-2-1024x772.webp" alt="Flow Cytometer ZS-AE7S" width="1024" height="772" srcset="https://keylaser.am/wp-content/uploads/2026/03/MT8600-2-1024x772.webp 1024w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-2-300x226.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-2-768x579.webp 768w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-2-600x452.webp 600w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-2.webp 1199w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /></p>
<p><strong>Recommended Reagent Information:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Item</td>
<td>Recommended Reagent</td>
<td>Application Department</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Lymphocyte Subset T Analysis</td>
<td>CD45</p>
<p>CD4</p>
<p>CD3</p>
<p>CD8</td>
<td rowspan="2">Clinical Laboratory</p>
<p>Infectious Disease Department</p>
<p>Oncology Department</p>
<p>Department of Rheumatology and Immunology</p>
<p>Department of Pediatrics Blood Specialty</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Lymphocyte Subset T/B/NK Analysis</td>
<td>CD45</p>
<p>CD3</p>
<p>CD16</p>
<p>CD56</p>
<p>CD19</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Absolute Count of CD4+T Lymphocyte</td>
<td>CD45</p>
<p>CD4</p>
<p>CD3</p>
<p>CD8</td>
<td>CDC (AIDS)</p>
<p>Infectious Disease Department</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Cytokine Th1/Th2/Th17 Analysis</td>
<td>Th1: IL-2, IFN-γ, TNF-α</p>
<p>Th2: IL-4, IL-6, IL-10</p>
<p>Th17: IL-17</td>
<td>Infectious Disease Department</p>
<p>Oncology Department</p>
<p>Department of Rheumatology and Immunology</p>
<p>Department of Organ Transplantation</p>
<p>Respiratory Department</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>HLA-B27 Detection for AS</td>
<td>HLA-B27-FITC</p>
<p>HLA-B7-PE</p>
<p>IgG2a-FITC</p>
<p>IgG1-PE</td>
<td>Department of Rheumatology and Immunology</p>
<p>Orthopedics</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>DFI Analysis</td>
<td>Acridine orange (AO) Staining Solution</td>
<td>Reproductive Department</p>
<p>Infertility Department</p>
<p>Reproductive Medicine Centre</td>
</tr>
</tbody>
</table>
</div>
</div>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index1">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>ZS-AE7S</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Laser</td>
<td>488nm solid（60mW）</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Detector</td>
<td>FSC, SSC, FL1-FL5</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Fluorescence Channel</td>
<td>FL1:525/50（FITC）</p>
<p>FL2:585/40（PE）</p>
<p>FL3:630/30（PE-Texas Red/ECD/PI）</p>
<p>FL4:697/60（PerCP/PE-Cy5/PE-Cy5.5）</p>
<p>FL5:780/60（PE-Cy7）</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Fluorescence Sensitivity</td>
<td>FITC≤50 MESF, PE≤30MESF</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Fluorescence Linearity</td>
<td>≥0.99</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>FSC Sensitivity</td>
<td>≤1μm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Test Particle Size</td>
<td>0.2~50μm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Carry Over</td>
<td>≤0.5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Instrument CV</td>
<td>FSC and all FL channel CV less than 2%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>FSC and SSC CV</td>
<td>Can separate red blood cells and platelet, can separate white blood cells into 3 groups</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Test Speed</td>
<td>≥46000 cells/s</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Minimum Sample Vol</td>
<td>90μL</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Measure Range</td>
<td>Maximum Support 10⁷</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Threshold</td>
<td>Double threshold, minimum cells fraction</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Fluorescence Compensation</td>
<td>Support auto online compensation, offline compensation and visualized compensation</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Item Template</td>
<td>Support Item template, acquisition conditions/fluorescence compensation one-click use</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Intake Method</td>
<td>Manual intake</p>
<p>Rotary wheel auto-sampling with auto-mixing function:32tests/wheel</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Liquid Storage Station</td>
<td>Sheath bottle, waste bottle, shutdown liquid bottle 2L,</p>
<p>cleaning liquid bottle 0.5L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Software</td>
<td>English/Chinese</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>PC</td>
<td>Dell（CPU i5/8G DDR4/1T hard disk）+Dell 27 inches monitor</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power Supply</td>
<td>AC220/110V±10%, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Optional</td>
<td>Auto-sampler</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size(W*D*H)</td>
<td>430*500*330mm</p>
<p>650*500*330mm(with autosampler)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>30kg</p>
<p>35kg(with autosampler)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Packing Size(W*D*H)</td>
<td>Main Instrument: 860*635*648mm</p>
<p>Accessories: 860*680*810mm</p>
<p>Reagent: 405*270*400mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>Main Instrument: 56kg</p>
<p>Accessories: 54kg</p>
<p>Reagent: 16kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/flow-cytometer-zs-ae7s/">Flow Cytometer ZS-AE7S</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Portable Veterinary Fluorescence Immunoassay Analyzer</title>
		<link>https://keylaser.am/product/portable-veterinary-fluorescence-immunoassay-analyzer/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 23 Mar 2026 07:48:33 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14950</guid>

					<description><![CDATA[<p><label>Model: </label>BKP500VET</p>
<p>The BKP500VET portable veterinary fluorescence immunoassay analyzer uses fluorescence immunoassay to accurately quantify specific analytes in animal serum, plasma, whole blood, or urine samples. This instrument features fast detection speed, compact portability, long battery life, and supports barcode recognition and intelligent data management. It is suitable for use in research institutes, animal experimental centers, animal and plant quarantine departments, veterinary hospitals, and livestock and veterinary systems.</p>
<p>The post <a href="https://keylaser.am/product/portable-veterinary-fluorescence-immunoassay-analyzer/">Portable Veterinary Fluorescence Immunoassay Analyzer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. Lightweight and compact, handheld design.</p>
<p>2. Long battery life: built-in high-performance lithium battery, providing up to 4 hours of continuous operation.</p>
<p>3. Single test completed in just 8 seconds; supports multiple tests per card, significantly improving work efficiency.</p>
<p>4. Equipped with a 5.0-inch color touchscreen, user-friendly interface, rapid response, and intuitive workflow.</p>
<p>5. Large storage capacity: can store over 100,000 data entries.</p>
<p>6. Optional thermal printer available.</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BKP500VET</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reaction Principle</td>
<td>Fluorescence Immunoassay</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Detection Channel</td>
<td>Single Channel</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Detecting Animal</td>
<td>Cat, dog</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Detection Speed</td>
<td>&lt;8 seconds per test</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Detection Mode</td>
<td>Single-item per card; Multi-item combined detection per card</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Type</td>
<td>20 customizable sample types (Whole blood, serum, plasma, urine, etc.)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Screen Size</td>
<td>5.0-inch color touchscreen</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Data Storage Capacity</td>
<td>&gt;100,000pcs</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Printer</td>
<td>External (Bluetooth/USB) thermal printer (Optional)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Barcode Scanning</td>
<td>1D code, 2D code</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Battery Life (Full Charge)</td>
<td>Continuous operation for 4 hours</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Data Transmission</td>
<td>LIS, WIFI, USB, Bluetooth; 4G (Optional)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power Supply</td>
<td>AC100~240V, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Instrument Size(W*D*H)</td>
<td>210*90*45mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Net Weight</td>
<td>0.75kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Packing Size(W*D*H)</td>
<td>250*160*145mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Gross Weight</td>
<td>2.5kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/portable-veterinary-fluorescence-immunoassay-analyzer/">Portable Veterinary Fluorescence Immunoassay Analyzer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fibrinogen (FIB) Assay Kit</title>
		<link>https://keylaser.am/product/fibrinogen-fib-assay-kit/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 23 Mar 2026 06:17:49 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14872</guid>

					<description><![CDATA[<p><label>Model: </label>FIB</p>
<p>Fibrinogen is the main protein in the coagulation process. In addition to the stress response under physiological conditions and the third trimester of pregnancy, FIB increase mainly occurs in acute infections, burns, atherosclerosis, acute myocardial infarction, autoimmune diseases, multiple Myeloma, diabetes, pregnancy-induced hypertension and acute nephritis, uremia, etc.; FIB reduction is mainly seen in DIC, primary hyperthyroidism, severe hepatitis, liver cirrhosis and thrombolytic therapy.<br />
This kit is used to quantitatively determine the content of fibrinogen in human plasma in vitro for auxiliary diagnosis.</p>
<p>The post <a href="https://keylaser.am/product/fibrinogen-fib-assay-kit/">Fibrinogen (FIB) Assay Kit</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. Stable performance.</p>
<p>2. Good precision.</p>
<p>3. Easy to transport.</p>
<p><strong>T</strong><strong>echnical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td colspan="2">Product Name</td>
<td>Fibrinogen(FIB) Assay Kit</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Component</td>
<td>Reagent: 2ml*5, 2.5ml*5, 1ml*10</p>
<p>Diluent: 50ml*2</p>
<p>Calibrator: 0.5ml*1, 1.0ml*1</p>
<p>QC(normal, abnormal): 0.5 ml*1, 1.0 ml*1</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Reagent Performance</td>
<td>Accuracy</td>
<td>R≤15%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Linearity</td>
<td>R&gt;0.98@80~500mg/dl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Repeatability</td>
<td>CV≤8%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Batch Variations</td>
<td>CV≤15%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Calibrator Performance</td>
<td>Correctness</td>
<td>|En| ≤1</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>In-bottle Uniformity</td>
<td>CV≤10%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Uniformity Between Bottles</td>
<td>CV≤10%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="2">QC Performance</td>
<td>In-bottle Uniformity</td>
<td>CV≤10%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Uniformity between Bottles</td>
<td>CV≤10%</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/fibrinogen-fib-assay-kit/">Fibrinogen (FIB) Assay Kit</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Thrombin Time (TT) Assay Kit</title>
		<link>https://keylaser.am/product/thrombin-time-tt-assay-kit/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 23 Mar 2026 06:14:26 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14866</guid>

					<description><![CDATA[<p>&#160;</p>
<p><label>Model: </label>TT</p>
<p>Activated partial thromboplastin time(APTT) is a screening test to check endogenous coagulation factors, and is used to confirm the deficiencies of congenital or acquired coagulation factors VI, IX, XI or the presence of their corresponding inhibitors; At the same time, APTT can also be used to confirm the deficiency of coagulation factor XI, prokallikrein and high molecular weight prokallikrein; due to the high sensitivity of APTT and the action pathway of heparin is mainly the endogenous coagulation pathway, APTT has become the preferred indicator for monitoring unfractionated heparin, with a ratio of 1.5~2.5 being the best.<br />
This kit is used for the determination of activated partial thromboplastin time in human plasma in vitro for auxiliary diagnosis.</p>
<p>The post <a href="https://keylaser.am/product/thrombin-time-tt-assay-kit/">Thrombin Time (TT) Assay Kit</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. Good stability.</p>
<p>2. Complete specifications.</p>
<p>3. High precision.</p>
<p><strong>T</strong><strong>echnical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td colspan="2">Product Name</td>
<td>Thrombin Time(TT) Assay Kit</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Component</td>
<td>Reagent: 2ml*10, 2.5ml*10, 4ml*10</p>
<p>Reconstitution solution: 25ml*1, 30ml*1, 45ml*1</p>
<p>QC(normal, abnormal): 0.5ml*1, 1.0ml*1</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Reagent Performance</td>
<td>Reference Range</td>
<td>≤20s</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Repeatability</td>
<td>CV≤5%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Batch Variations</td>
<td>R≤10%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="2">QC Performance</td>
<td>In-bottle Uniformity</td>
<td>CV≤10%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Uniformity Between Bottles</td>
<td>CV≤10%</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/thrombin-time-tt-assay-kit/">Thrombin Time (TT) Assay Kit</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Prothrombin Time(PT) Assay Kit</title>
		<link>https://keylaser.am/product/prothrombin-timept-assay-kit/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 23 Mar 2026 06:10:18 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14860</guid>

					<description><![CDATA[<p>Activated partial thromboplastin time(APTT) is a screening test to check endogenous coagulation factors, and is used to confirm the deficiencies of congenital or acquired coagulation factors VI, IX, XI or the presence of their corresponding inhibitors; At the same time, APTT can also be used to confirm the deficiency of coagulation factor XI, prokallikrein and high molecular weight prokallikrein; due to the high sensitivity of APTT and the action pathway of heparin is mainly the endogenous coagulation pathway, APTT has become the preferred indicator for monitoring unfractionated heparin, with a ratio of 1.5~2.5 being the best.<br />
This kit is used for the determination of activated partial thromboplastin time in human plasma in vitro for auxiliary diagnosis.</p>
<p>The post <a href="https://keylaser.am/product/prothrombin-timept-assay-kit/">Prothrombin Time(PT) Assay Kit</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. High precision.</p>
<p>2. Stable performance.</p>
<p>3. Strong anti-interference.</p>
<p><strong>T</strong><strong>echnical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td colspan="2">Product Name</td>
<td>Prothrombin Time(PT) Assay Kit</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Component</td>
<td>Reagent: 2ml*10, 2.5ml*10, 4ml*10</p>
<p>Reconstitution Solution: 25ml*1, 30ml*1, 45ml*1</p>
<p>QC(normal, abnormal): 0.5ml*1, 1.0ml*1</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Reagent Performance</td>
<td>Reference Range</td>
<td>≤14s</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Repeatability</td>
<td>CV≤5%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Batch Variations</td>
<td>R≤10%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="2">QC Performance</td>
<td>In-bottle Uniformity</td>
<td>CV≤10%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Uniformity Between Bottles</td>
<td>CV≤10%</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/prothrombin-timept-assay-kit/">Prothrombin Time(PT) Assay Kit</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>3-Part Auto Hematology Analyzer Reagent</title>
		<link>https://keylaser.am/product/3-part-auto-hematology-analyzer-reagent/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 18 Mar 2026 17:56:25 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14792</guid>

					<description><![CDATA[<p><label>Model: </label>SFL SFL-1 10×SFL-1 SFL-DM (Veterinary) SFL-TK (Veterinary) Probe Cleaning Fluid II E-Z Cleaning Fluid</p>
<p>Lyse SFL、SFL-DM、SFL-TK: used to destroy red blood cells, dissolve hemoglobin, and maintain the required morphology of analyzed cells before blood cell analysis, so as to facilitate cell classification and counting or hemoglobin quantitative determination.</p>
<p>The post <a href="https://keylaser.am/product/3-part-auto-hematology-analyzer-reagent/">3-Part Auto Hematology Analyzer Reagent</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Introduction:</strong></p>
<p>Lyse SFL/SFL-DM/SFL-TK: used to destroy red blood cells, dissolve hemoglobin, and maintain the required morphology of analyzed cells before blood cell analysis, so as to facilitate cell classification and counting or hemoglobin quantitative determination.</p>
<p>Diluent SFL-1: used to dilute samples and prepare cell suspensions before blood cell analysis.</p>
<p>Diluent 10×SFL-1: used to dilute samples and prepare cell suspensions before blood cell analysis. Concentrated version of diluent SFL-1: which needs to be diluted before use.</p>
<p>Probe Cleaning Fluid II: used to cleaning the instrument regularly.</p>
<p>E-Z Cleaning Fluid: used to clean and rinse the injector, valve and piping system. Cleaning the instrument regularly.</p>
<p><strong>Features:</strong></p>
<p>1. It is highly versatile and can be used in various types of three-classification blood cell analyzers.</p>
<p>2. It has high stability. The reagent should be stored indoors away from light at a temperature of 8~30°C. The validity period is 24 months(SFL-DM, SFL-TK is 18 months). The validity period after opening the bottle is 60 days.</p>
<p>3. It has high safety, cyanide-free formula, non-toxic and harmless, and protects the environment.</p>
<p>4. SFL is applicable to 3-Part Hematology Analyzer BH-HA310.</p>
<p>5. SFL-DM is applicable to 3-Part Hematology Analyzer BH-HA310VET.</p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>SFL</td>
<td>SFL-1</td>
<td>10×SFL-1</td>
<td>SFL-DM(Veterinary)</td>
<td>SFL-TK(Veterinary)</td>
<td>Probe</p>
<p>Cleaning Fluid II</td>
<td>E-Z Cleaning Fluid</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Specification</td>
<td>1l, 500ml, 300ml, 250ml, 200ml, 120ml</td>
<td colspan="2">1l, 2l, 3l, 5l, 10l, 18l, 20l</td>
<td colspan="2">1l, 500ml, 300ml, 250ml, 200ml, 120ml</td>
<td colspan="2">50ml, 100ml</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Component</td>
<td>Na2HPO4, KH2PO4, Hexadecyltrimethylammonium bromide, Triton X-100, NaNO2, BSA</td>
<td colspan="2">NaCl, Na2HPO4, KH2PO4, KCl,</p>
<p>Ethylenediaminetetraacetic acid disodium salt, Ethelene glycol monophenyl ether</td>
<td>Citric acid,</p>
<p>Hexadecyltrimethylammonium bromide, Triton X-100, BSA</td>
<td>Na2HPO4, KH2PO4, Hexadecyltrimethylammonium bromide, Triton X-100, BSA</td>
<td>Surfactants, Trisodium citrate dihydrate,Na2HPO4，NaH2PO4</td>
<td>Surfactants, Antibacterial agents, Proteolytic enzymes, etc</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/3-part-auto-hematology-analyzer-reagent/">3-Part Auto Hematology Analyzer Reagent</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>5-Part Auto Hematology Analyzer Reagent</title>
		<link>https://keylaser.am/product/5-part-auto-hematology-analyzer-reagent/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 18 Mar 2026 17:51:40 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14783</guid>

					<description><![CDATA[<p>Reagents used in conjunction with the 5-part hematology analyzer.</p>
<p>The post <a href="https://keylaser.am/product/5-part-auto-hematology-analyzer-reagent/">5-Part Auto Hematology Analyzer Reagent</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Introduction:</strong></p>
<p>Lyse WFL-LH: used to destroy red blood cells, dissolve hemoglobin, and maintain the morphology of the cells to be analyzed before blood cell analysis, so as to facilitate cell classification and counting or hemoglobin quantitative determination.</p>
<p>Lyse WFL-LD: used to maintain cell morphology and perform white.</p>
<p>Diluent WFL-2: used to dilute samples and prepare cell suspensions before blood cell analysis.</p>
<p>Diluent 10×WFL-2: used to dilute samples and prepare cell suspensions before blood cell analysis. Concentrated version of diluent WFL-2, which needs to be diluted before use.</p>
<p>Probe Cleaning Fluid II: used to cleaning the instrument regularly.</p>
<p>E-Z Cleaning Fluid: used to clean and rinse the injector, valve and piping system. Cleaning the instrument regularly.</p>
<p><strong>Features:</strong></p>
<p>1. High accuracy, dedicated machine, benchmarked against national standard substances.</p>
<p>2. High stability, the reagent is stored indoors away from light, the temperature is 8~30℃, the validity period is 24 months, the validity period after opening the bottle is 60 days.</p>
<p>3. High safety, cyanide-free formula, non-toxic and harmless, environmental protection.</p>
<p>4. Applicable to 5-Part Auto Hematology Analyzer BK-6310, BK-6500.</p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>WFL-LH</td>
<td>WFL-LD</td>
<td>WFL-2</td>
<td>10×WFL-2</td>
<td>Probe Cleaning Fluid II</td>
<td>E-Z Cleaning Fluid</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Specification</td>
<td colspan="2">1l, 500ml, 300ml, 250ml, 200ml, 120ml</td>
<td colspan="2">1l, 2l, 3l, 5l, 10l, 18l, 20l</td>
<td colspan="2">50ml, 100ml</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Component</td>
<td>Na2HPO4, KH2PO4, NaCl, Hexadecyl trimethyl ammonium chloride, BSA</td>
<td>Na2HPO4, KH2PO4, Hexadecyl trimethyl ammonium bromide, Triton X-100, NaNO2, BSA</td>
<td colspan="2">NaCl, Na2HPO4, KH2PO4, KCl, Formaldehyde, Ethelene glycol monophenyl ether</td>
<td>Surfactants, Trisodium citrate dihydrate, Na2HPO4，NaH2PO4</td>
<td>Surfactants, Antibacterial agents, Proteolytic enzymes, etc.</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/5-part-auto-hematology-analyzer-reagent/">5-Part Auto Hematology Analyzer Reagent</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Rapid Test Kit(Colloidal Gold)</title>
		<link>https://keylaser.am/product/rapid-test-kitcolloidal-gold/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 18 Mar 2026 16:38:13 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14728</guid>

					<description><![CDATA[<p>Hospitals, customs, health and epidemic prevention departments, personal and family use, etc.</p>
<p>The post <a href="https://keylaser.am/product/rapid-test-kitcolloidal-gold/">Rapid Test Kit(Colloidal Gold)</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Test Items:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>No.</td>
<td>Name</td>
<td>Packing Parameters</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>1</td>
<td>Chikungunya IgG/IgM Combo Rapid Test Kit(Colloidal Gold)</td>
<td>Packaging Information: 25 pieces/box, 36 boxes/carton</p>
<p>Packaging Size: 630*460*250mm</p>
<p>Gross Weight: 12kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>2</td>
<td>Combined Detection Kit For Influenza A/B(Colloidal Gold)</td>
<td>Packaging Information: 25 pieces/box, 36 boxes/carton</p>
<p>Packaging Size: 630*460*250mm</p>
<p>Gross Weight: 12kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>3</td>
<td>Dengue Rapid Test Kit(Colloidal Gold)</td>
<td>Packaging Information: 25 pieces/box, 36 boxes/carton</p>
<p>Packaging Size: 630*460*250mm</p>
<p>Gross Weight: 12kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>4</td>
<td>Helicobacter Pylori Antibody Rapid Test Kit(Colloidal Gold)</td>
<td>Packaging Information: 25 pieces/box, 36 boxes/carton</p>
<p>Packaging Size: 630*460*250mm</p>
<p>Gross Weight: 12kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>5</td>
<td>Malaria P.Falciparum/P.Vivax Rapid Test Kit(Colloidal Gold)</td>
<td>Packaging Information: 25 pieces/box, 36 boxes/carton</p>
<p>Packaging Size: 630*460*250mm</p>
<p>Gross Weight: 12kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>6</td>
<td>Typhoid Rapid Test Kit(Colloidal Gold)</td>
<td>Packaging Information: 25 pieces/box, 36 boxes/carton</p>
<p>Packaging Size: 630*460*250mm</p>
<p>Gross Weight: 12kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>7</td>
<td>6-Monoacetylmorphine Test Kit(Colloidal Gold)</td>
<td>Packaging Information: 25 pieces/box, 36 boxes/carton</p>
<p>Packaging Size: 630*460*250mm</p>
<p>Gross Weight: 12kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>8</td>
<td>Amphetamine Test Kit(Colloidal Gold)</td>
<td>Packaging Information: 25 pieces/box, 36 boxes/carton</p>
<p>Packaging Size: 630*460*250mm</p>
<p>Gross Weight: 12kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>9</td>
<td>Benzodiazepine Test Kit(Colloidal Gold)</td>
<td>Packaging Information: 25 pieces/box, 36 boxes/carton</p>
<p>Packaging Size: 630*460*250mm</p>
<p>Gross Weight: 12kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>10</td>
<td>Buprenorphine Test Kit(Colloidal Gold)</td>
<td>Packaging Information: 25 pieces/box, 36 boxes/carton</p>
<p>Packaging Size: 630*460*250mm</p>
<p>Gross Weight: 12kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>11</td>
<td>MDMA Test Kit(Colloidal Gold)</td>
<td>Packaging Information: 25 pieces/box, 36 boxes/carton</p>
<p>Packaging Size: 630*460*250mm</p>
<p>Gross Weight: 12kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>12</td>
<td>Cocaine Test Kit(Colloidal Gold)</td>
<td>Packaging Information: 25 pieces/box, 36 boxes/carton</p>
<p>Packaging Size: 630*460*250mm</p>
<p>Gross Weight: 12kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>13</td>
<td>Ketamine Test Kit(Colloidal Gold)</td>
<td>Packaging Information: 25 pieces/box, 36 boxes/carton</p>
<p>Packaging Size: 630*460*250mm</p>
<p>Gross Weight: 12kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>14</td>
<td>Morphine Test Kit(Colloidal Gold)</td>
<td>Packaging Information: 25 pieces/box, 36 boxes/carton</p>
<p>Packaging Size: 630*460*250mm</p>
<p>Gross Weight: 12kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>15</td>
<td>Tetrahydrocannabinolic Acid Test Kit(Colloidal Gold)</td>
<td>Packaging Information: 25 pieces/box, 36 boxes/carton</p>
<p>Packaging Size: 630*460*250mm</p>
<p>Gross Weight: 12kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>16</td>
<td>Luteinizing Hormone(LH) Test Kit(Colloidal Gold)</td>
<td>Packaging Information: 25 pieces/box, 36 boxes/carton</p>
<p>Packaging Size: 630*460*250mm</p>
<p>Gross Weight: 12kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>17</td>
<td>Follicle-Stimulating Hormone(FSH) Test Kit(Colloidal Gold)</td>
<td>Packaging Information: 25 pieces/box, 36 boxes/carton</p>
<p>Packaging Size: 630*460*250mm</p>
<p>Gross Weight: 12kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>18</td>
<td>Beta-Human Chorionic Gonadotropin(β-HCG) Test Kit(Colloidal Gold)</td>
<td>Packaging Information: 25 pieces/box, 36 boxes/carton</p>
<p>Packaging Size: 630*460*250mm</p>
<p>Gross Weight: 12kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/rapid-test-kitcolloidal-gold/">Rapid Test Kit(Colloidal Gold)</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>