<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Clinical&amp;Analytical Instrument Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-tag/clinicalanalytical-instrument/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-tag/clinicalanalytical-instrument/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Mon, 23 Mar 2026 08:12:02 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>Clinical&amp;Analytical Instrument Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-tag/clinicalanalytical-instrument/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Automatic Chemistry &#038; Immunoassay Analyzer MT8600</title>
		<link>https://keylaser.am/product/automatic-chemistry-immunoassay-analyzer-mt8600/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 23 Mar 2026 08:05:51 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14958</guid>

					<description><![CDATA[<p><label>Model: </label>MT8600</p>
<p>The automatic chemistry &#38; immunoassay analyzer is a fully automated integrated platform that seamlessly connects the chemistry analyzer and immunoassay via a track system. It enables parallel processing of the same sample, completing both biochemical and immunoassay tests in a single operation.<br />
This system revolutionizes traditional workflows, significantly improving efficiency and minimizing manual operation and sample turnaround time. Simultaneously, by reducing human intervention, it effectively reduces result errors, ensuring a high degree of consistency and reliability in testing quality, making it a core piece of equipment in modern large-scale medical institution laboratories.</p>
<p>The post <a href="https://keylaser.am/product/automatic-chemistry-immunoassay-analyzer-mt8600/">Automatic Chemistry &#038; Immunoassay Analyzer MT8600</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img fetchpriority="high" decoding="async" class="wp-image-14969 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/MT8600.webp" alt="Automatic Chemistry &amp; Immunoassay Analyzer MT8600" width="959" height="779" srcset="https://keylaser.am/wp-content/uploads/2026/03/MT8600.webp 959w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-300x244.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-768x624.webp 768w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-600x487.webp 600w" sizes="(max-width: 959px) 100vw, 959px" /></p>
<p><strong>Flexible Combination Mode</strong></p>
<p><strong>Dual-module</strong></p>
<p><strong>Single Chemistry Module + Single Immunoassay Module</strong></p>
<p>Chemistry: 2000 Tests/hour; Immunoassay: 600 Tests/hour; Electrolytes: 600 Tests/hour</p>
<p><img decoding="async" class="wp-image-14963 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-8.webp" alt="Automatic Chemistry &amp; Immunoassay Analyzer MT8600" width="640" height="640" srcset="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-8.webp 640w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-8-300x300.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-8-150x150.webp 150w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-8-600x600.webp 600w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-8-100x100.webp 100w" sizes="(max-width: 640px) 100vw, 640px" /></p>
<p><strong>Triple-module</strong></p>
<p><strong>Dual Chemistry Modules + Single Immunoassay Module</strong></p>
<p>Chemistry: 4000 Tests/hour; Immunoassay: 600 Tests/hour; Electrolytes: 1200 Tests/hour</p>
<p><strong>Single Chemistry Module + Dual Immunoassay Modules</strong></p>
<p>Chemistry: 2000 Tests/hour; Immunoassay: 1200 Tests/hour; Electrolytes: 600 Tests/hour</p>
<figure id="attachment_14962" aria-describedby="caption-attachment-14962" style="width: 640px" class="wp-caption alignnone"><img decoding="async" class="wp-image-14962 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-19.webp" alt="Automatic Chemistry &amp; Immunoassay Analyzer MT8600" width="640" height="640" srcset="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-19.webp 640w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-19-300x300.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-19-150x150.webp 150w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-19-600x600.webp 600w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-1-19-100x100.webp 100w" sizes="(max-width: 640px) 100vw, 640px" /><figcaption id="caption-attachment-14962" class="wp-caption-text"><strong>Quadruple-module</strong><br /><strong>Dual Chemistry Modules + Dual Immunoassay Modules</strong><br />Chemistry: 4000 Tests/hour; Immunoassay: 1200 Tests/hour; Electrolytes: 1200 Tests/hour<br /><strong>Triple Chemistry Modules + Single Immunoassay Module</strong><br />Chemistry: 6000 Tests/hour; Immunoassay: 600 Tests/hour; Electrolytes: 1800 Tests/hour<br /><strong>Single Chemistry Module + Triple Immunoassay Modules</strong><br />Chemistry: 2000 Tests/hour; Immunoassay: 1800 Tests/hour; Electrolytes: 600 Tests/hour</figcaption></figure>
<p>&nbsp;</p>
<figure id="attachment_14961" aria-describedby="caption-attachment-14961" style="width: 640px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-14961 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-800-800-7.webp" alt="Automatic Chemistry &amp; Immunoassay Analyzer MT8600" width="640" height="640" srcset="https://keylaser.am/wp-content/uploads/2026/03/pt-main2-800-800-7.webp 640w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-800-800-7-300x300.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-800-800-7-150x150.webp 150w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-800-800-7-600x600.webp 600w, https://keylaser.am/wp-content/uploads/2026/03/pt-main2-800-800-7-100x100.webp 100w" sizes="auto, (max-width: 640px) 100vw, 640px" /><figcaption id="caption-attachment-14961" class="wp-caption-text"> </figcaption></figure>
<figure id="attachment_14968" aria-describedby="caption-attachment-14968" style="width: 839px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-14968 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/MT8600-1.webp" alt="Automatic Chemistry &amp; Immunoassay Analyzer MT8600" width="839" height="444" srcset="https://keylaser.am/wp-content/uploads/2026/03/MT8600-1.webp 839w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-1-300x159.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-1-768x406.webp 768w, https://keylaser.am/wp-content/uploads/2026/03/MT8600-1-600x318.webp 600w" sizes="auto, (max-width: 839px) 100vw, 839px" /><figcaption id="caption-attachment-14968" class="wp-caption-text"> </figcaption></figure>
<p><strong>Features</strong><strong>:</strong></p>
<p><strong>01/ Intelligent System Software</strong></p>
<p>Automatic retesting of abnormal samples</p>
<p>Intelligent sample scheduling</p>
<p>Automatic alarm handling</p>
<p>Automatic cleaning and maintenance</p>
<p>Reagent remaining level warning</p>
<p><strong>02/Sample Processing System</strong></p>
<p>Automatic sample rack type scanning</p>
<p>Sample quality identification (Optional)</p>
<p>Sample tube type identification</p>
<p>Maximum loading of 350 samples per batch</p>
<p>Emergency priority function</p>
<p><strong>03/Immunoassay System</strong></p>
<p>Tube-type magnetic microparticle enzymatic chemiluminescence</p>
<p>Non-contact mixing</p>
<p>Reagent and consumable loading and unloading without stopping the system</p>
<p>Single unit throughput 600 Tests/hour</p>
<p><strong>04/Chemistry System</strong></p>
<p>Reagent loading and unloading without system shutdown</p>
<p>Total reaction volume as low as 80μL</p>
<p>Single unit throughput 2000 Tests/hour</p>
<p>ISE module throughput 600 Tests/hour (Optional)</p>
<p>Emergency results reporting time as fast as 10min</p>
<p><strong>Technical Parameters</strong><strong>:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="882">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td colspan="2">Model</td>
<td>MT8600</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="13">Chemistry Analyzer Module</td>
<td>Throughput</td>
<td>2000 Tests/hour; Optional ISE module 600 Tests/hour</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Type</td>
<td>Serum, plasma, whole blood, urine, cerebrospinal fluid, semen, stool</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Loading Mode</td>
<td>Track loading, with emergency track</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Position</td>
<td>Maximum 350 samples loaded at one time, original tube loading with sample rack</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Position</td>
<td>250 positions, 2 cold storage functional reagent disks</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Volume</td>
<td>1~35μL, increasing by 0.1μL</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Volume</td>
<td>1~350μL</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Reaction Volume</td>
<td>80~350μL</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Probe</td>
<td>Liquid level sensing, random tracking, three-dimensional anti-collision protection</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Wavelength Range</td>
<td>340nm~850nm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reaction Temperature</td>
<td>Circulating water bath, constant temperature 37±0.1℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>External Dimensions(W*D*H)</td>
<td>1505*1225*1245mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Net Weight</td>
<td>500kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="11">Immunoassay Module</td>
<td>Throughput</td>
<td>600 Tests/hour</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reaction Principle</td>
<td>Tubular magnetic particle enzymatic chemiluminescence</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Type</td>
<td>Serum, plasma, urine</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Cleaning Module</td>
<td>Double cleaning module, triple magnetic separation cleaning technology, non-contact type mixing</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Reagent Position</td>
<td>Double reagent disks, 50 reagent positions, 2~8℃ cold storage</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reaction Tube Capacity</td>
<td>2000 reaction tubes, support random loading</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Incubation Position</td>
<td>A total of 238 incubation positions, 37±0.1℃, dry bath heating</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Sample Position</td>
<td>Maximum 350 samples loaded at one time, original tube loading with sample rack</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Other Functions</td>
<td>Reagent radio frequency identification, sample needle collision prevention, liquid level detection, automatic dilution, optional clot detection, etc.</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Dimensions(W*D*H)</td>
<td>1500*1225*1245mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>500kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4">Sample Loading Module</td>
<td>Sample Position</td>
<td>350 sample positions, 450 samples delivered per hour</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>STAT Function</td>
<td>Equipped with emergency priority function</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Dimensions(W*D*H)</td>
<td>972*1225*1495mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>160kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="3">Others</td>
<td>Power Supply</td>
<td>AC220 50/60Hz (Standard); AC110 50/60Hz (Optional), 4950VA</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Packing Size(W*D*H)</td>
<td>1685*1410*1460mm; 1685*1410*1460mm; 1410*1350*1170mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Gross Weight</td>
<td>670kg; 650kg; 360kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/automatic-chemistry-immunoassay-analyzer-mt8600/">Automatic Chemistry &#038; Immunoassay Analyzer MT8600</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Activated Partial Thromboplastin Time(APTT) Assay Kit</title>
		<link>https://keylaser.am/product/activated-partial-thromboplastin-timeaptt-assay-kit/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 19 Mar 2026 16:04:07 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14854</guid>

					<description><![CDATA[<p>Activated partial thromboplastin time(APTT) is a screening test to check endogenous coagulation factors, and is used to confirm the deficiencies of congenital or acquired coagulation factors VI, IX, XI or the presence of their corresponding inhibitors; At the same time, APTT can also be used to confirm the deficiency of coagulation factor XI, prokallikrein and high molecular weight prokallikrein; due to the high sensitivity of APTT and the action pathway of heparin is mainly the endogenous coagulation pathway, APTT has become the preferred indicator for monitoring unfractionated heparin, with a ratio of 1.5~2.5 being the best.<br />
This kit is used for the determination of activated partial thromboplastin time in human plasma in vitro for auxiliary diagnosis.</p>
<p>The post <a href="https://keylaser.am/product/activated-partial-thromboplastin-timeaptt-assay-kit/">Activated Partial Thromboplastin Time(APTT) Assay Kit</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. Convenient and efficient.</p>
<p>2. High accuracy.</p>
<p>3. Good repeatability.</p>
<p><strong>T</strong><strong>echnical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td colspan="2">Product Name</td>
<td>Activated Partial Thromboplastin Time(APTT) Assay Kit</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="2">Component</td>
<td>Reagent: 2ml*10, 2.5ml*10, 4ml*10</p>
<p>CaCl2: 25ml*1, 30ml*1, 45ml*1</p>
<p>QC(normal, abnormal): 0.5ml*1, 1.0ml*1</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Reagent Performance</td>
<td>Reference Range</td>
<td>≤35s</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Repeatability</td>
<td>CV≤5%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Batch Variations</td>
<td>R≤10%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="2">QC Performance</td>
<td>In-bottle Uniformity</td>
<td>CV≤10%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Uniformity Between Bottles</td>
<td>CV≤10%</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/activated-partial-thromboplastin-timeaptt-assay-kit/">Activated Partial Thromboplastin Time(APTT) Assay Kit</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Reagent for Electrolyte Analyzer(ISE)</title>
		<link>https://keylaser.am/product/reagent-for-electrolyte-analyzerise/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 19 Mar 2026 16:00:40 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14850</guid>

					<description><![CDATA[<div class="pro-this-prodBrief">Electrolyte reagents are suitable for BKE series (BKE-A, BKE-B, BKE-C, BKE-D) electrolyte analyzers. It is used for quantitative detection of K+, Na+, Cl-, Ca2+ and pH in serum.</div>
<p>The post <a href="https://keylaser.am/product/reagent-for-electrolyte-analyzerise/">Reagent for Electrolyte Analyzer(ISE)</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. High quality raw materials.</p>
<p>2. Stable performance.</p>
<p>3. Long shelf life.</p>
<p>4. Multiple specifications optional.</p>
<p><strong>T</strong><strong>echnical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Product Name</td>
<td>Reagent for Electrolyte Analyzer(ISE)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Component</td>
<td>Drift correction solution A(350ml)</p>
<p>Slope correction solution B(350ml)</p>
<p>Reference solution(10ml*2)</p>
<p>Filling solution in electrode(3ml)</p>
<p>Cleaning fluid E(100ml)</p>
<p>Electrode activation fluid(100ml)</p>
<p>Internal correction solution(100ml)</p>
<p>Electrode cleaning fluid(protease): Protease: 25mg*5; Diluent: 5ml*1</p>
<p>Drift correction solution(CO<sub>2</sub> standard 1): 100ml*1(only for BKE-E/F/L)</p>
<p>Slope correction solution(CO<sub>2</sub> standard 2): 100ml*1(only for BKE-E/F/L)</p>
<p>CO<sub>2 </sub>acidic washing: 100ml*1(only for BKE-E/F/L)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Precision</td>
<td>TCO<sub>2, </sub>Mg<sup>2+</sup> repeatability CV<a name="OLE_LINK7"></a><a name="OLE_LINK7"></a>≤3.5%; Batch variations R≤5%</p>
<p>iCa<sup>2+</sup><sub>, </sub>Li<sup>+</sup> repeatability CV≤1.5%; Batch variations R≤3%</p>
<p>Others repeatability CV≤1.5%; Batch variations R≤2%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Accuracy</td>
<td>K<sup>+</sup>, Na<sup>+</sup>, Cl<sup>&#8211;</sup>, pH<sup> </sup>relative deviation≤±3.0%</p>
<p>iCa<sup>2+</sup><sub>, </sub>Li<sup>+</sup>, Mg<sup>2+</sup><sup> </sup>relative deviation≤±5%, or≤±0.05mmol/L</p>
<p>TCO<sub>2</sub> relative deviation≤±5%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Linearity</td>
<td>r≥0.995</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size(L*W*H)mm</td>
<td>Commodity inspection reagent:</p>
<p>220*160*120(only for BKE-A/B/C/D), 280*135*210(only for BKE-E/F/L)</p>
<p>Non-commodity inspection reagent: 220*160*120</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight(kg)</td>
<td>Commodity inspection reagent:</p>
<p>1.7(only for BKE-A/B/C/D), 2.2(only for BKE-E/F/L)</p>
<p>Non-commodity inspection reagent:</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/reagent-for-electrolyte-analyzerise/">Reagent for Electrolyte Analyzer(ISE)</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Auto ELISA Processor BIOBASE1000</title>
		<link>https://keylaser.am/product/11358/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 14:14:08 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11358</guid>

					<description><![CDATA[<p><strong>Introduction:</strong></p>
<p>The auto elisa processor is an analytical instrument used in the field of hospital, laboratory. Its main function is to analyze sample pre-processing, sample analysis and data processing.</p>
<p>The post <a href="https://keylaser.am/product/11358/">Auto ELISA Processor BIOBASE1000</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BIOBASE 1000</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1. 1 robotic arm, 1 pipetting probe(10~1000μl).</p>
<p>2. 2 units 96 well microplates(independent incubating).</p>
<p>3. 1 unit reader&amp;washer(auto reading and washing).</p>
<p>&nbsp;</p>
<p><img loading="lazy" decoding="async" class="wp-image-11355 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/Biobase1000.webp" alt="Auto ELISA Processor BIOBASE1000" width="1247" height="451" srcset="https://keylaser.am/wp-content/uploads/2024/10/Biobase1000.webp 1247w, https://keylaser.am/wp-content/uploads/2024/10/Biobase1000-300x109.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/Biobase1000-1024x370.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/Biobase1000-768x278.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/Biobase1000-600x217.webp 600w" sizes="auto, (max-width: 1247px) 100vw, 1247px" /><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="2">BIOBASE1000</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="3">Sample Unit</td>
<td>Sample Racks</td>
<td>Standard 192 sample position (expandable, up to 384)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Pipetting</td>
<td>10~1000μl</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Dispensing System</td>
<td>1 aspirating-dispensing probe(X-Y-Z movement)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Reagent Unit</td>
<td>Reagent Racks</td>
<td>Universal reagent position: Standard 6 universal reagent positions(expandable, up to 32);</p>
<p>Original reagent bottle: Standard 20 reagent bottles position(expandable, up to 80)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Pipetting Range</td>
<td>10~1000μl, 1μl stepping</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Pipetting Precision</td>
<td>(100μl)CV≤0.5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Dispensing Time</td>
<td>5 minutes to whole 96 well microplates</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Incubation Unit</td>
<td>Incubation</td>
<td>2 independent incubators</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature Range</td>
<td>RT to 45 °C</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temperature Accuracy</td>
<td>±0.5°C</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="3">Washing Unit</td>
<td>Washing Probes</td>
<td>Two line 8-nozzle manifolds</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Wash Containers</td>
<td>2 wash buffers 2L, 1 distilled water, 1 waste water</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Washing Residual</td>
<td>&lt;2μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Reading Unit</td>
<td>Reading Channels</td>
<td>8 independent photometric channels, mono and dichromatic reading</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Absorbance</td>
<td>0.0~3.0OD</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Spectral Range</td>
<td>400~700nm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Optical Filters</td>
<td>2 standard filters(450, 630nm);</p>
<p>2 more on request(405nm/450nm/492nm/630nm)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Data Management</td>
<td>Software</td>
<td>Windows 7</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>LIS System</td>
<td>Bi-direction, support HL7 protocol</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Results</td>
<td>Absorbance and results reviewable by software</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Printer</td>
<td>External optional</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Working Conditions</td>
<td>Power Supply</td>
<td>AC220V±10%, 50/60Hz; 110V±10%, 60Hz, 400W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature</td>
<td>10~30℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Humidity</td>
<td>30~80%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4">Size&amp;Weight</td>
<td>External Size (W*D*H)</td>
<td>933*685*860mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>130kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size (W*D*H)</td>
<td>1085*840*1318mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>180kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/11358/">Auto ELISA Processor BIOBASE1000</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Auto ELISA Processor BIOBASE2000</title>
		<link>https://keylaser.am/product/auto-elisa-processor-biobase2000/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 14:08:43 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11342</guid>

					<description><![CDATA[<p><strong>Introduction:</strong></p>
<p>The auto elisa processor is an analytical instrument used in the field of hospital, laboratory. Its main function is to analyze sample pre-processing, sample analysis and data processing.</p>
<p>The post <a href="https://keylaser.am/product/auto-elisa-processor-biobase2000/">Auto ELISA Processor BIOBASE2000</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BIOBASE 2000</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<div class="ast-oembed-container " style="height: 100%;"><iframe loading="lazy" title="BIOBASE 2000 Auto Elisa Processor" width="1778" height="1000" src="https://www.youtube.com/embed/B4J2hYPz2KI?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
<p>&nbsp;</p>
<p><strong>Features:</strong></p>
<p>1. 1 robotic arm, 2 pipetting probes(10~1000μl).</p>
<p>2. 4 units 96 well microplates(independent incubating).</p>
<p>3. 1 unit reader&amp;washer(auto reading and washing).</p>
</div>
<p>&nbsp;</p>
<p><img loading="lazy" decoding="async" class="wp-image-11343 size-large" src="https://keylaser.am/wp-content/uploads/2024/10/01-1-1024x374.webp" alt="Auto ELISA Processor BIOBASE2000" width="1024" height="374" srcset="https://keylaser.am/wp-content/uploads/2024/10/01-1-1024x374.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/01-1-300x110.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/01-1-768x281.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/01-1-600x219.webp 600w, https://keylaser.am/wp-content/uploads/2024/10/01-1.webp 1113w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /></p>
<div class="prodDetail-editor-container">
<p><strong>Technical Parameters:</strong></p>
<div>
<div>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="2">BIOBASE2000</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="3">Sample Unit</td>
<td>Sample Racks</td>
<td>Standard 192 sample positions(expandable, up to 552)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Pipetting</td>
<td>10~1000μl</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Dispensing System</td>
<td>2 aspirating and dispensing probe( X-Y-Z movement)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Reagent Unit</td>
<td>Reagent Position</td>
<td>23 reagent racks, editable</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Pipetting Range</td>
<td>10~1000μl,  1μl stepping</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Pipetting Precision</td>
<td>(100μl)CV≤0.5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="5">Washing Unit</td>
<td>Dispensing Time</td>
<td>4 minutes to whole 96 to microplates</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Washing Probes</td>
<td>Two line 8-nozzle manifolds</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Wash Containers</td>
<td>Cleaning fluid(15L), waste water(25L), Buffer 1(5L),  Buffer 2(2L),</p>
<p>Buffer 3(2L),  Buffer 4(2L), with liquid level-sensing, liquid shortage and full alarm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Waste Containers</td>
<td>25L with waste full sensor</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Washing Residual</td>
<td>&lt;2μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="5">Reading Unit</td>
<td>Reading Channels</td>
<td>8 independent photometric channels,  mono anddichromatic reading</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Absorbance</td>
<td>0.0~3.0OD</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Spectral Range</td>
<td>400~700nm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Optical Filters</td>
<td>2 standard filters(450, 630nm); 2 more on request (405nm/450nm/492nm/630nm)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Reading Accuracy</td>
<td>±1% from 0~1.5OD, ±2% from 1.5~3.0OD</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="3">Incubation Unit</td>
<td>Incubators</td>
<td>4 independent units</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temperature Range</td>
<td>RT to 45℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature Accuracy</td>
<td>±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Data Management</td>
<td>Software System</td>
<td>Above Windows 7 system</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>LIS System</td>
<td>Bi-direction, support HL7 protocol</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Results</td>
<td>Absorbance and results reviewable by software</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Printer</td>
<td>External optional</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Working Conditions</td>
<td>Power Supply</td>
<td>AC220V±10%, 50/60Hz; 110V±10%, 60Hz, 400W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature</td>
<td>10~30℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Humidity</td>
<td>30%~80%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4">Size&amp;Weight</td>
<td>External Size (W*D*H)</td>
<td>1235*705*875mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>146kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size (W*D*H)</td>
<td>1380*860*1435mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>220kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/auto-elisa-processor-biobase2000/">Auto ELISA Processor BIOBASE2000</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Auto ELISA Processor BIOBASE2001</title>
		<link>https://keylaser.am/product/auto-elisa-processor-biobase2001/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 14:05:16 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11333</guid>

					<description><![CDATA[<p><strong>Introduction:</strong><br />
Auto ELISA Processor BIOBASE2001 is a fully automaticdetection equipment that integrates sample addition,incubation, shaking, washing, and reading. lt is widely usedin hospital laboratories, disease prevention and controlcenters, blood centers, and blood banks, animal and plantinspection and quarantine institutions, scientific researchinstitutions, university laboratories and other places.</p>
<p>The post <a href="https://keylaser.am/product/auto-elisa-processor-biobase2001/">Auto ELISA Processor BIOBASE2001</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BIOBASE2001</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1. Adopt the principle of pressure type liquid detection</p>
<p>2. With TIP detection, clot detection function</p>
<p>3. High-precision pipetting</p>
<p>4. Position sensing, real-time monitoring of gripper status</p>
<p>5. Multi-spacing and multi-strength adjustable grippers can be adapted to grasp and place microplates and plate covers of different sizes</p>
<p>6. Dual thread control, can run simultaneously with the sampling arm without interfering with each other</p>
<p>&nbsp;</p>
</div>
<figure id="attachment_11334" aria-describedby="caption-attachment-11334" style="width: 1212px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-11334 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/BIOBASE2001-1.webp" alt="Auto ELISA Processor BIOBASE2001" width="1212" height="816" srcset="https://keylaser.am/wp-content/uploads/2024/10/BIOBASE2001-1.webp 1212w, https://keylaser.am/wp-content/uploads/2024/10/BIOBASE2001-1-300x202.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/BIOBASE2001-1-1024x689.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/BIOBASE2001-1-768x517.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/BIOBASE2001-1-600x404.webp 600w" sizes="auto, (max-width: 1212px) 100vw, 1212px" /><figcaption id="caption-attachment-11334" class="wp-caption-text"> </figcaption></figure>
<p>&nbsp;</p>
<div class="prodDetail-editor-container">
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="2">BIOBASE2001</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="7">Sample&amp;Reagent Unit</td>
<td>Sample Racks</td>
<td>6*20 push-pull sample rack with detection</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Channel</td>
<td>2 channels</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Liquid Level Detection</td>
<td>Air pressure level detection, clot detection function</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Tip</td>
<td>1000μl, 3 tip racks</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Pipetting</td>
<td>10μl~1000μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Pipetting Precision</td>
<td>100μl: CV≤1%, Accuracy≤2.5%</p>
<p>1000μl: CV≤0.5%, Accuracy≤1%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Position</td>
<td>4 reagent racks, reagent tanks with detection</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Washing Unit</td>
<td>Washer</td>
<td>1 unit</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Washing Head</td>
<td>16-channel(32-pin), double row cleaning, hanging installation, with leakage recovery</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Injection Uniformity</td>
<td>CV&lt;1.5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Washing Residual</td>
<td>&lt;1μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="8">Reading Unit</td>
<td>Reading Channels</td>
<td>8 independent photometric channels</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Linear Range</td>
<td>0.000~3.000Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Repeatability</td>
<td>CV≤1.0%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Stability</td>
<td>≤±0.003Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Optical Filters</td>
<td>4 standard filters(405, 450, 492, 630nm);</p>
<p>Total 10 filters positions</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reading Accuracy</td>
<td>≤±0.02Abs from 0.0 to 1.0OD</p>
<p>≤±0.03Abs from 1.0 to 2.0OD</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sensitivity</td>
<td>≥0.01mg/L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Channel Difference</td>
<td>≤0.02Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="7">Incubation Unit</td>
<td>Incubators</td>
<td>8 shaking incubators</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Cover Positions</td>
<td>1(8 covers)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Heating Method</td>
<td>Dry heating with cover</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Shaking Function</td>
<td>Horizontal circular oscillation, 1-3 levels adjustable, amplitude 2.5mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temperature Range</td>
<td>RT to 60 °C</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature Uniformity</td>
<td>0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temperature Fluctuation</td>
<td>±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="5">Data Management</td>
<td>Software</td>
<td>Above Windows 7 system</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>LIS System</td>
<td>Bi-direction, support HL7 protocol</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Results</td>
<td>Absorbance and results reviewable by software</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Printer</td>
<td>External optional</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Built-in Scanner</td>
<td>Optional</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Other Function</td>
<td>Biosafety Protection</td>
<td>Optional (Negative pressure working zone, HEPA filter)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Disinfection</td>
<td>UV lamp</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Lighting</td>
<td>LED</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>IAP Function</td>
<td>Firmware can be upgraded online at any time</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Working Condition</td>
<td>Power Supply</td>
<td>AC220V±10%, 50/60Hz(Standard); 110V±10%, 60Hz( Optional)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature</td>
<td>10~40℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Humidity</td>
<td>30~80%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4">Size&amp;Weight</td>
<td>External Size (W*D*H)</td>
<td>1275*750*1650mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>330kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size(W*D*H)mm</td>
<td>Machine: 1445*1130*920</p>
<p>Base Stand: 1445*1005*920</p>
<p>Accessories: 1065*510*895</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight(kg)</td>
<td>Machine: 220</p>
<p>Base Stand: 125</p>
<p>Accessories: 30</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/auto-elisa-processor-biobase2001/">Auto ELISA Processor BIOBASE2001</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Auto ELISA Processor BIOBASE1001</title>
		<link>https://keylaser.am/product/auto-elisa-processor-biobase1001/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 14:00:03 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11324</guid>

					<description><![CDATA[<p><strong>Introduction:</strong><br />
The Auto ELISA Processor BIOBASE1001 is a fully automatic detection equipment that integrates sample addition, incubation, shaking, washing, and reading. It is widely used in hospital laboratories, disease prevention and control centers, blood centers, and blood banks. , animal and plant inspection and quarantine institutions, scientific research institutions, university laboratories and other places.</p>
<p>The post <a href="https://keylaser.am/product/auto-elisa-processor-biobase1001/">Auto ELISA Processor BIOBASE1001</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BIOBASE1001</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1. Adopt the principle of pressure type liquid detection</p>
<p>2. With TIP detection, clot detection function</p>
<p>3. High-precision pipetting, the lowest volume can reach 10μl</p>
<p>4. Position sensing, real-time monitoring of gripper status</p>
<p>5. Multi-spacing and multi-strength adjustable grippers can be adapted to grasp and place microplates and plate covers of different sizes</p>
<p>6. Dual thread control, can run simultaneously with the sampling arm without interfering with each other</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="882">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="2" width="71">BIOBASE1001</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="8" width="71">Sample&amp; Reagent Unit</td>
<td width="79">Sample Racks</td>
<td>6*20 push-pull sample rack</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Sampling Channel</td>
<td width="458">1 channel</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="221">Liquid Level Detection</td>
<td width="458">Air pressure level detection, clot detection function</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Tip</td>
<td width="458">1000μl, 2 tip racks</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Pipetting</td>
<td width="458">10μl~1000μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Pipetting Precision</td>
<td width="458">100μl: CV≤1%, Accuracy≤2.5%</p>
<p>1000μl: CV≤0.5%, Accuracy≤1%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Reagent Position</td>
<td width="458">2 reagent racks</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Dilution Plate Position</td>
<td width="458">1 dilution plate position with incubation and shaking</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4" width="71">Washing Unit</td>
<td width="79">Washer</td>
<td>1 unit</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Washing Head</td>
<td width="458">16-channel (32-pin), double row cleaning, hanging installation, with leakage recovery</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Injection Uniformity</td>
<td width="458">CV&lt;1.5%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Washing Residual</td>
<td width="458">&lt;2μl</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="10" width="71">Reading Unit</td>
<td width="79">Reading Channels</td>
<td>8 independent photometric channels, mono and dichromatic reading</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Absorbance Range</td>
<td width="458">0.000~4.000Abs</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Linear Range</td>
<td width="458">0.000~3.000Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Repeatability</td>
<td width="458">CV≤1.0%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Stability</td>
<td width="458">≤±0.003Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Spectral Range</td>
<td width="458">400~700nm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Optical Filters</td>
<td width="458">4 standard filters(405, 450, 492, 630nm);</p>
<p>Total 10 filters positions</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Reading Accuracy</td>
<td width="458">≤±0.02Abs from 0.0 to 1.0 OD,</p>
<p>≤±0.03Abs from 1.0 to 2.0 OD</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Sensitivity</td>
<td width="458">≥0.01mg/L</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Channel Difference</td>
<td width="458">≤0.02Abs</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="7" width="71">Incubation Unit</td>
<td width="79">Incubators</td>
<td>2 shaking incubators</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Cover Position</td>
<td width="458">1 (2 covers)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Heating Method</td>
<td width="458">Dry heating with cover</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Shaking Function</td>
<td width="458">Horizontal circular oscillation, 1-3 levels adjustable, amplitude 2.5mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Temperature Range</td>
<td width="458">RT to 60 °C</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Temperature Uniformity</td>
<td width="458">±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Temperature Fluctuation</td>
<td width="458">±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="5" width="71">Data Management</td>
<td width="79">Software</td>
<td>Above Windows 7 system</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">LIS System</td>
<td width="458">Bi-direction, support HL7 protocol</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Results</td>
<td width="458">Absorbance and results reviewable by software</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Printer</td>
<td width="458">External optional</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Built-in Scanner</td>
<td width="458">Optional</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4" width="71">Other Function</td>
<td width="79">Biosafety Protection</td>
<td>Optional (Negative pressure working zone, HEPA filter)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Disinfection</td>
<td width="458">UV lamp</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Lighting</td>
<td width="458">LED</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">IAP Function</td>
<td width="458">Firmware can be upgraded online at any time</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="3" width="71">Working Condition</td>
<td width="79">Power Supply</td>
<td>AC220V±10%, 50/60Hz(Standard); 110V±10%, 60Hz(Optional)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Temperature</td>
<td width="458">10~40℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Humidity</td>
<td width="458">30~80%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4" width="71">Size &amp; Weight</td>
<td width="79">External Size (W*D*H)</td>
<td>870*700*885mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Net Weight</td>
<td width="458">180kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Package Size(W*D*H)</td>
<td width="458">Machine: 1018*828*1130mm</p>
<p>Accessories: 750*1000*700mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Gross Weight</td>
<td width="458">Machine: 160kg</p>
<p>Accessories: 80kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/auto-elisa-processor-biobase1001/">Auto ELISA Processor BIOBASE1001</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Auto ELISA Processor BIOBASE4001</title>
		<link>https://keylaser.am/product/auto-elisa-processor-biobase4001/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 13:51:25 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11314</guid>

					<description><![CDATA[<p><strong>Introduction:</strong><br />
Auto ELISA Processor BIOBASE4001 is a fully automatic detection equipment that integrates sample addition, incubation, shaking, washing, and reading. It is widely used in hospital laboratories, disease prevention and control centers, blood centers, and blood banks, animal and plant inspection and quarantine institutions, scientific research institutions, university laboratories and other places.</p>
<p>The post <a href="https://keylaser.am/product/auto-elisa-processor-biobase4001/">Auto ELISA Processor BIOBASE4001</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BIOBASE4001</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1. Adopt the principle of pressure type liquid detection</p>
<p>2. With TIP detection, clot detection function</p>
<p>3. High-precision pipetting, the lowest volume can reach 5μl</p>
<p>4. Position sensing, real-time monitoring of gripper status</p>
<p>5. Multi-spacing and multi-strength adjustable grippers can be adapted to grasp and place microplates and plate covers of different sizes</p>
<p>6. Dual thread control, can run simultaneously with the sampling arm without interfering with each other</p>
</div>
<p>&nbsp;</p>
</div>
<figure id="attachment_11315" aria-describedby="caption-attachment-11315" style="width: 1276px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-11315 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/02-2.webp" alt="Auto ELISA Processor BIOBASE4001" width="1276" height="853" srcset="https://keylaser.am/wp-content/uploads/2024/10/02-2.webp 1276w, https://keylaser.am/wp-content/uploads/2024/10/02-2-300x201.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/02-2-1024x685.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/02-2-768x513.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/02-2-600x401.webp 600w" sizes="auto, (max-width: 1276px) 100vw, 1276px" /><figcaption id="caption-attachment-11315" class="wp-caption-text"> </figcaption></figure>
<p><strong style="font-size: 16px;">T</strong><strong style="font-size: 16px;">echnical Parameters:</strong></p>
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="2">BIOBASE4001</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="7">Sample&amp;Reagent Unit</td>
<td>Sample Racks</td>
<td>12*16 push-pull sample rack with detection</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sampling Channel</td>
<td>4 channels</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Liquid Level Detection</td>
<td>Air pressure level detection, clot detection function</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Tip</td>
<td>1000μl, 5 tip racks</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Pipetting</td>
<td>5μl~1000μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Pipetting Precision</td>
<td>100μl: CV≤0.5%, Accuracy≤2.0%</p>
<p>1000μl: CV≤0.5%, Accuracy≤0.5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Position</td>
<td>6 reagent racks, reagent tanks with detection</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Washing Unit</td>
<td>Washer</td>
<td>2 units</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Washing Head</td>
<td>16-channel(32-pin), double row cleaning, hanging installation, with leakage recovery</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Injection Uniformity</td>
<td>CV&lt;1.5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Washing Residual</td>
<td>&lt;1μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="8">Reading Unit</td>
<td>Reading Channels</td>
<td>8 independent photometric channels, mono and dichromatic reading</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Linear Range</td>
<td>0.000~3.000Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Repeatability</td>
<td>CV≤1.0%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Stability</td>
<td>≤±0.003Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Optical Filters</td>
<td>4 standard filters(405, 450, 492, 630nm)</p>
<p>Total 10 filters positions</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reading Accuracy</td>
<td>≤±0.02Abs from 0.0 to 1.0OD</p>
<p>≤±0.03Abs from 1.0 to 2.0OD</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sensitivity</td>
<td>≥0.01mg/L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Channel Difference</td>
<td>≤0.02Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="7">Incubation Unit</td>
<td>Incubators</td>
<td>12 shaking incubators</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Cover Positions</td>
<td>2(12 covers)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Heating Method</td>
<td>Dry heating with cover</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Shaking Function</td>
<td>Horizontal circular oscillation, 1~3 levels adjustable, amplitude 2.5mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temperature Range</td>
<td>RT to 60 °C</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature Uniformity</td>
<td>0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temperature Fluctuation</td>
<td>±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="5">Data Management</td>
<td>Software</td>
<td>Above Windows 7 system</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>LIS System</td>
<td>Bi-direction, support HL7 protocol</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Results</td>
<td>Absorbance and results reviewable by software</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Printer</td>
<td>External optional</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Built-in Scanner</td>
<td>Optional</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Other Function</td>
<td>Biosafety Protection</td>
<td>Optional(Negative pressure working zone, HEPA filter)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Disinfection</td>
<td>UV lamp</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Lighting</td>
<td>LED</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>IAP Function</td>
<td>Firmware can be upgraded online at any time</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Working Condition</td>
<td>Power Supply</td>
<td>AC220V±10%, 50/60Hz(Standard); 110V±10%, 60Hz(Optional)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature</td>
<td>10~40℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Humidity</td>
<td>30~80%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4">Size&amp;Weight</td>
<td>External Size (W*D*H)</td>
<td>1775*190*1683mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>445kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size(W*D*H)mm</td>
<td>Machine: 1945*950*1150</p>
<p>Base Stand: 1945*950*995</p>
<p>Accessories: 1370*930*530</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight(kg)</td>
<td>Machine: 364.5</p>
<p>Base Stand: 208.5</p>
<p>Accessories: 97</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/auto-elisa-processor-biobase4001/">Auto ELISA Processor BIOBASE4001</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Microplate Shaker BK-MS300</title>
		<link>https://keylaser.am/product/microplate-shaker-bk-ms300/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 13:47:45 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11310</guid>

					<description><![CDATA[<p><strong>Introduction:</strong><br />
BK-MS300 Thermo Shaker for Microplates is a multipurpose thermostatic shaker controlled by brushless DC motor and PID intelligent temperature control technology.The PID fuzzy control technology can be accurate to ensure that the temperature control precision and automatically adjust the heating rate, reduce waiting time.</p>
<p>The post <a href="https://keylaser.am/product/microplate-shaker-bk-ms300/">Microplate Shaker BK-MS300</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BK-MS300</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1. Easy to set up and use, all information real-time display and snowing set up operation, convenient to observe equipment running status.</p>
<p>2. Support standard microplates and deep well plates.</p>
<p>3. Brushless DC motor, low noise, small interference, free maintenance.</p>
<p>4. Automatic preheating function.</p>
<p>5. Automatic power recovery function.</p>
<p>6. Temperature calibration function.</p>
<p>7.Built-in software and hardware over temperature protection device, will use more reliable.</p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BK-MS300</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temp. Setting Range</td>
<td>0~80℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Control Range</td>
<td>RT+5℃~80℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Timing Range</td>
<td>1min~99h59min/∞</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Accuracy</td>
<td>≤±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Display Accuracy</td>
<td>0.1℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp Uniformity</td>
<td>≤±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Shaking Speed</td>
<td>200~1350rpm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Orbit</td>
<td>3mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Auto Preheating</td>
<td>Yes</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Auto Resume to Run</td>
<td>Yes</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Capacity</td>
<td>4 microplates or deep-well plates</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Power Supply</td>
<td>300W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Voltage</td>
<td>AC220V or AC110V, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Heating Time</td>
<td>≤15min(from 25℃ to 80℃)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Dimension</td>
<td>340*320*200mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>9.5kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size(W*D*H)</td>
<td>490*450*315mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>11.5kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/microplate-shaker-bk-ms300/">Microplate Shaker BK-MS300</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Microplate Shaker BK-MS200 BK-MS300</title>
		<link>https://keylaser.am/product/microplate-shaker-bk-ms200/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 13:45:40 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11306</guid>

					<description><![CDATA[<p><label>Model: </label>BK-MS200 BK-MS300</p>
<p>It is with technique of brushless DC motor and PID intelligent temperature control. Mainly used for shaking and cultivation in Elisa plates (96/384 wells) or 96 wells tissue culture plates.</p>
<p>The post <a href="https://keylaser.am/product/microplate-shaker-bk-ms200/">Microplate Shaker BK-MS200 BK-MS300</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features for BK-MS200:</strong></p>
<p>1. LCD displays system status and parameters.</p>
<p>2. Stable and reliable operation with high quality switch.</p>
<p>3. Easy to operate with one touch knob.</p>
<p>4. Set-up the time within 0~100 hours, instrument will make alarm voice when completing.</p>
<p>5. With power recovery, instrument will be continuous to run when power recovers from outage.</p>
<p><strong>Features for BK-MS300:</strong></p>
<p>1. Easy to set up and use, all information real-time display and showing setup operation, convenient to observe equipment running status.</p>
<p>2. Support standard microplates and deep well plates.</p>
<p>3. Brushless DC motor, low noise, small interference, free maintenance.</p>
<p>4. Automatic preheating function.</p>
<p>5. Automatic power recovery function.</p>
<p>6. Temperature calibration function.</p>
<p>7. Built-in software and hardware over temperature protection device, will use more reliable.</p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BK-MS200</td>
<td>BK-MS300</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temp. Setting Range</td>
<td colspan="2">0~80℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Control Range</td>
<td colspan="2">RT+5~80℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Timing Range</td>
<td colspan="2">1min~99h59min/∞</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Accuracy</td>
<td colspan="2">≤±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Display Accuracy</td>
<td colspan="2">0.1℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Uniformity</td>
<td colspan="2">≤±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Shaking Speed</td>
<td>200~1600rpm</td>
<td>200~1350rpm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Orbit</td>
<td colspan="2">3mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Capacity</td>
<td>2pcs of microplates or culture plates</td>
<td>4pcs of microplates or deep-well plates</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Heating Time</td>
<td>≤10min(from RT. to 80℃)</td>
<td>≤15min(from 25℃ to 80℃)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power</td>
<td>150W</td>
<td>300W</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Power Supply</td>
<td colspan="2">220V, 50/60Hz; 110V, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Dimension</td>
<td>280*270*140mm</td>
<td>340*320*200mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>7.0kg</td>
<td>9.5kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Packing Size</td>
<td>410*350*240mm</td>
<td>460*440*300mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>7.8kg</td>
<td>11.08kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/microplate-shaker-bk-ms200/">Microplate Shaker BK-MS200 BK-MS300</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
