<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Electrolyte Analyzer Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-tag/electrolyte-analyzer/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-tag/electrolyte-analyzer/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Thu, 19 Mar 2026 16:00:40 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>Electrolyte Analyzer Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-tag/electrolyte-analyzer/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Reagent for Electrolyte Analyzer(ISE)</title>
		<link>https://keylaser.am/product/reagent-for-electrolyte-analyzerise/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 19 Mar 2026 16:00:40 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14850</guid>

					<description><![CDATA[<div class="pro-this-prodBrief">Electrolyte reagents are suitable for BKE series (BKE-A, BKE-B, BKE-C, BKE-D) electrolyte analyzers. It is used for quantitative detection of K+, Na+, Cl-, Ca2+ and pH in serum.</div>
<p>The post <a href="https://keylaser.am/product/reagent-for-electrolyte-analyzerise/">Reagent for Electrolyte Analyzer(ISE)</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. High quality raw materials.</p>
<p>2. Stable performance.</p>
<p>3. Long shelf life.</p>
<p>4. Multiple specifications optional.</p>
<p><strong>T</strong><strong>echnical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Product Name</td>
<td>Reagent for Electrolyte Analyzer(ISE)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Component</td>
<td>Drift correction solution A(350ml)</p>
<p>Slope correction solution B(350ml)</p>
<p>Reference solution(10ml*2)</p>
<p>Filling solution in electrode(3ml)</p>
<p>Cleaning fluid E(100ml)</p>
<p>Electrode activation fluid(100ml)</p>
<p>Internal correction solution(100ml)</p>
<p>Electrode cleaning fluid(protease): Protease: 25mg*5; Diluent: 5ml*1</p>
<p>Drift correction solution(CO<sub>2</sub> standard 1): 100ml*1(only for BKE-E/F/L)</p>
<p>Slope correction solution(CO<sub>2</sub> standard 2): 100ml*1(only for BKE-E/F/L)</p>
<p>CO<sub>2 </sub>acidic washing: 100ml*1(only for BKE-E/F/L)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Precision</td>
<td>TCO<sub>2, </sub>Mg<sup>2+</sup> repeatability CV<a name="OLE_LINK7"></a><a name="OLE_LINK7"></a>≤3.5%; Batch variations R≤5%</p>
<p>iCa<sup>2+</sup><sub>, </sub>Li<sup>+</sup> repeatability CV≤1.5%; Batch variations R≤3%</p>
<p>Others repeatability CV≤1.5%; Batch variations R≤2%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Accuracy</td>
<td>K<sup>+</sup>, Na<sup>+</sup>, Cl<sup>&#8211;</sup>, pH<sup> </sup>relative deviation≤±3.0%</p>
<p>iCa<sup>2+</sup><sub>, </sub>Li<sup>+</sup>, Mg<sup>2+</sup><sup> </sup>relative deviation≤±5%, or≤±0.05mmol/L</p>
<p>TCO<sub>2</sub> relative deviation≤±5%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Linearity</td>
<td>r≥0.995</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size(L*W*H)mm</td>
<td>Commodity inspection reagent:</p>
<p>220*160*120(only for BKE-A/B/C/D), 280*135*210(only for BKE-E/F/L)</p>
<p>Non-commodity inspection reagent: 220*160*120</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight(kg)</td>
<td>Commodity inspection reagent:</p>
<p>1.7(only for BKE-A/B/C/D), 2.2(only for BKE-E/F/L)</p>
<p>Non-commodity inspection reagent:</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/reagent-for-electrolyte-analyzerise/">Reagent for Electrolyte Analyzer(ISE)</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electrolyte Analyzer</title>
		<link>https://keylaser.am/product/electrolyte-analyzer/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 09:44:14 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11193</guid>

					<description><![CDATA[<p><strong>Introduction:</strong><br />
BKE series electrolyte analyzer adopts advanced ion selective electrode measurement technology, which can directly measure the concentration of K+, Na+, Cl-, Ca2+ and pH in serum, plasma, whole blood, cerebrospinal fluid and diluted urine. It is a fast, accurate, convenient and practical clinical testing instrument.</p>
<p>The post <a href="https://keylaser.am/product/electrolyte-analyzer/">Electrolyte Analyzer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="ast-oembed-container " style="height: 100%;"><iframe title="BIOBASE  Electrolyte Analyzer BKE Series  BKE A/C" width="1778" height="1000" src="https://www.youtube.com/embed/jsZnGbfGtaQ?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
<p>&nbsp;</p>
<p><strong>Features:</strong></p>
<p>1. The software supports automatic potential tracking correction to ensure stable performance</p>
<p>2. Automatic monitoring and filtering of tiny air bubbles to ensure measurement accuracy</p>
<p>3. Wave flushing and pipeline flushing can avoid blockage and cross-contamination</p>
<p>4. Power-off protection, can protect data storage, the result can be stored up to 50,000</p>
<p>5. Low consumption, effectively reducing the cost of consumables</p>
<p>6. 7-inch high-definition touch screen, comprehensive content display</p>
<p>7. With the function of automatic fault alarm and elimination, improve work efficiency</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BKE-A/B/C/D</td>
<td>BKE-E/F/L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Sample</td>
<td colspan="2">Serum, plasma, whole blood, cerebrospinal fluid and dilute urine</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Measuring Speed</td>
<td colspan="2">≤25s</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Analysis Method</td>
<td colspan="2">Ion selective electrode(ISE)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Volume</td>
<td>60~150μl</td>
<td>200μl</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Sample Position</td>
<td colspan="2">30 sample positions, 5 emergency positions(Only for BKE-B/D/F/L)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Injection Mode</td>
<td colspan="2">Manual or automatic injection can be selected(Only for BKE-B/D/F/L), BKE-A/C/E is manually injection</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Storage</td>
<td colspan="2">Up to 50,000 test results</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Printer</td>
<td colspan="2">Build-in thermal printer</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Interface</td>
<td colspan="2">RS232 port for LIS</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Display</td>
<td colspan="2">7-inch high-definition touch screen</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Language</td>
<td colspan="2">Chinese and English, other languages can be customized</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Calibration</td>
<td colspan="2">Automatic and Manual calibration</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Other Function</td>
<td colspan="2">Sample volume detection</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Power Supply</td>
<td colspan="2">AC100~240V, 50/60Hz, 70VA</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature</td>
<td colspan="2">+10~+40℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Relative Humidity</td>
<td colspan="2">≤80%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Atmospheric Pressure</td>
<td colspan="2">86~106kPa</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="sliderTable mt10 mb10 sliderTable-index1">
<div class="inner">
<table width="882">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BKE-A</td>
<td>BKE-B</td>
<td>BKE-C</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Test Items</td>
<td>K+, Na+, Cl-</td>
<td>K+, Na+, Cl-</td>
<td>K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Tray</td>
<td>No</td>
<td>Yes</td>
<td>No</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size(W*D*H)mm</td>
<td>405*214*471</td>
<td>628*287*471</td>
<td>405*214*471</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight(kg)</td>
<td>12.48</td>
<td>15.11</td>
<td>12.48</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size(W*D*H)mm</td>
<td>Instrument:</p>
<p>500*390*520</p>
<p>Reagent:</p>
<p>220*160*120</p>
<p>220*160*120</td>
<td>Instrument:</p>
<p>500*390*720</p>
<p>Reagent:</p>
<p>220*160*120</p>
<p>220*160*120</td>
<td>Instrument:</p>
<p>500*390*530</p>
<p>Reagent:</p>
<p>220*160*120</p>
<p>220*160*120</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight(kg)</td>
<td>Instrument: 16.08</p>
<p>Reagent: 1.7, 0.9</td>
<td>Instrument: 19.31</p>
<p>Reagent: 1.7, 0.9</td>
<td>Instrument: 16.08</p>
<p>Reagent: 1.7, 0.9</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Model</td>
<td>BKE-D</td>
<td>BKE-E</td>
<td>BKE-F</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Test Items</td>
<td>K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH</td>
<td>K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH, TCO2, AG</td>
<td>K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH, TCO2, AG</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Sample Tray</td>
<td>Yes</td>
<td>No</td>
<td>Yes</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>External Size(W*D*H)mm</td>
<td>682*287*471</td>
<td>405*214*471</td>
<td>682*287*471</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Net Weight(kg)</td>
<td>15.11</td>
<td>13.13</td>
<td>15.76</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Package Size(W*D*H)mm</td>
<td>Instrument:</p>
<p>500*390*720</p>
<p>Reagent:</p>
<p>220*160*120</p>
<p>220*160*120</td>
<td>Instrument:</p>
<p>500*390*530</p>
<p>Reagent:</p>
<p>280*135*210<br />
220*160*120</td>
<td>Instrument:</p>
<p>500*390*720</p>
<p>Reagent:</p>
<p>280*135*210<br />
220*160*120</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Gross Weight(kg)</td>
<td>Instrument: 19.31</p>
<p>Reagent: 1.7, 0.9</td>
<td>Instrument: 16.73</p>
<p>Reagent: 2.2, 1.2</td>
<td>Instrument: 19.96</p>
<p>Reagent: 2.2, 1.2</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Model</td>
<td>BKE-L</td>
<td colspan="2" rowspan="1" width="NaN"></td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Test Items</td>
<td colspan="3">K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH, TCO2, AG, Li+, Mg2+</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Tray</td>
<td colspan="3">Yes</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size(W*D*H)mm</td>
<td colspan="3">682*287*471</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight(kg)</td>
<td colspan="3">15.76</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size(W*D*H)mm</td>
<td colspan="3">Instrument:</p>
<p>500*390*720</p>
<p>Reagent:</p>
<p>280*135*210</p>
<p>220*160*120</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight(kg)</td>
<td colspan="3">Instrument: 19.96</p>
<p>Reagent: 2.2, 1.2</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="sliderTable mt10 mb10 sliderTable-index2">
<div class="inner">
<table width="100%">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td width="177">Items</td>
<td width="400">Measuring Range</td>
<td width="304">Resolution</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="177">K+</td>
<td width="400">0.5~20.0mmol/L</td>
<td width="304">0.01mmol/L</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="177">Na+</td>
<td width="400">15~200mmol/L</td>
<td width="304">0.01mmol/L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="177">Cl-</td>
<td width="400">15~200mmol/L</td>
<td width="304">0.01mmol/L</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="177">Ca2+</td>
<td width="400">0.1~6.0mmol/L</td>
<td width="304">0.01mmol/L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="177">pH</td>
<td width="400">4~9pH</td>
<td width="304">0.01pH</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="177">TCO2</td>
<td width="400">2.0~70.0mmol/L</td>
<td width="304">0.1mmol/L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="177">Li+</td>
<td width="400">0.1~6.0mmol/L</td>
<td width="304">0.01mmol/L</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="177">Mg2+</td>
<td width="400">0.1~4.0mmol/L</td>
<td width="304">0.01mmol/L</td>
</tr>