<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Elisa Reader and Washer Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-tag/elisa-reader-and-washer/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-tag/elisa-reader-and-washer/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Thu, 20 Mar 2025 16:29:35 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>Elisa Reader and Washer Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-tag/elisa-reader-and-washer/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Automatic Elisa Plate Reader, 96 Wells Plate</title>
		<link>https://keylaser.am/product/automatic-elisa-plate-reader-96-wells-plate/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 20 Mar 2025 16:29:35 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=13595</guid>

					<description><![CDATA[<p><strong>Model : ELMR-96; ELMR-96I</strong></p>
<div>
<div></div>
<div>Wavelength Range : 340～880nm<br />
Repeatability : [0, 3.0)≤0.3%, [3, 4.0)≤1%</div>
<div>Resolution : 0.001Abs</div>
<div>Accuracy : [0, 2.0)≤ ± 0.005, [2.0 ,3.0)≤ ± 1%, [3.0, 4.0)≤ ± 1.5%</div>
<div>Sizes(W×D×H)(mm) : 280x432x220</div>
<div>The elisa microplate reader is a fast and accurate way to read absorbance data from microplates and is suitable for use in biomedical research, clinical diagnostics, drug discovery and more.</div>
</div>
<p>The post <a href="https://keylaser.am/product/automatic-elisa-plate-reader-96-wells-plate/">Automatic Elisa Plate Reader, 96 Wells Plate</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2><strong>Elisa Plate Reader Specifications:</strong></h2>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="649">
<thead>
<tr class="firstRow">
<th width="210.33333333333334">Model</th>
<th width="396.3333333333333">ELMR-96/ELMR-96I</th>
</tr>
</thead>
<tbody>
<tr>
<td width="210.33333333333334">Light Source</td>
<td width="396.3333333333333">6V 10W halogen lamp</td>
</tr>
<tr>
<td width="210.33333333333334">Wavelength Range</td>
<td width="396.3333333333333">340～880nm</td>
</tr>
<tr>
<td width="210.33333333333334">Filter</td>
<td width="396.3333333333333">Standard configuration: 405, 450, 492, 630nm four filters; It can be loaded with up to eight filters</td>
</tr>
<tr>
<td width="210.33333333333334">Absorbance Range</td>
<td width="396.3333333333333">0.000-4.000Abs</td>
</tr>
<tr>
<td width="210.33333333333334">Resolution</td>
<td width="396.3333333333333">0.001Abs</td>
</tr>
<tr>
<td width="210.33333333333334">Linearity</td>
<td width="396.3333333333333">(0, 2.0)≤±1%; [2.0, 4.0)≤±2%</td>
</tr>
<tr>
<td width="210.33333333333334">Wavelength Indication Error</td>
<td width="396.3333333333333">≤±3nm</td>
</tr>
<tr>
<td width="210.33333333333334">Wavelength Repeatability</td>
<td width="396.3333333333333">≤±1.5nm</td>
</tr>
<tr>
<td width="210.33333333333334">Repeatability</td>
<td width="396.3333333333333">[0, 3.0)≤0.3%, [3, 4.0)≤1%</td>
</tr>
<tr>
<td width="210.33333333333334">Stability</td>
<td width="396.3333333333333">[0, 3.0)≤0.3%, [3.0, 4.0)≤1%</td>
</tr>
<tr>
<td width="210.33333333333334">Accuracy</td>
<td width="396.3333333333333">[0, 2.0)≤ ± 0.005, [2.0 ,3.0)≤ ± 1%, [3.0, 4.0)≤ ± 1.5%</td>
</tr>
<tr>
<td width="210.33333333333334">Sensitivity</td>
<td width="396.3333333333333">Sensitivity≥0.010</td>
</tr>
<tr>
<td width="210.33333333333334">Channel Difference</td>
<td width="396.3333333333333">&lt;0.01A(1.0Abs standard filter)</td>
</tr>
<tr>
<td width="210.33333333333334">Measuring Speed</td>
<td width="396.3333333333333">Single wavelength &lt;10s/96 wells, dual wavelengths &lt;16s/96 wells (normal mode)</td>
</tr>
<tr>
<td width="210.33333333333334">Incubation Temperature</td>
<td width="396.3333333333333">Room temperature+4℃-50℃ (ELMR-96I)</td>
</tr>
<tr>
<td width="210.33333333333334">Ambient Temperature</td>
<td width="396.3333333333333">4℃~ 45℃</td>
</tr>
<tr>
<td width="210.33333333333334">Relative Humidity</td>
<td width="396.3333333333333">≤70%</td>
</tr>
<tr>
<td width="210.33333333333334">Power Supply</td>
<td width="396.3333333333333">AC100-240V, 50/60Hz</td>
</tr>
<tr>
<td width="210.33333333333334">Sizes(W×D×H)(mm)</td>
<td width="396.3333333333333">280x432x220</td>
</tr>
<tr>
<td width="210.33333333333334">Shipping Size(W×D×H)(mm)</td>
<td width="396.3333333333333">580x430x360</td>
</tr>
<tr>
<td width="210.33333333333334">N.W./G.W. (kg)</td>
<td width="396.3333333333333">8.5/13</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>&nbsp;</p>
<h2><strong>Elisa Plate Reader Features:</strong></h2>
<p>The ELMR-96/ELMR-96I is a popular elisa plate reader capable of sensitively measuring absorbance signals on microtiter plates, accurately detecting and analyzing the concentration and activity of biomolecules.</p>
<ol class=" list-paddingleft-2">
<li>7-inch high-resolution LCD capacitive touch screen for simple operation and easy viewing of test results</li>
<li>Detection accuracy with single wavelength and dual wavelength detection for fast plate reading</li>
<li>A wavelength range of 340-880nm can meet a variety of applications</li>
<li>8-bit filter wheel, 4 filters as standard, with various other optional filters</li>
<li>With vibration plate function, vibration plate time and speed adjustable</li>
<li>With self-test and diagnostic functions for optical path, moving position, etc</li>
<li>Light source energy-saving design maximises the service life of the light source</li>
<li>There is no need to open the shell design; you can complete the replacement of light sources and filters</li>
</ol>
<h2><strong>Details of 96 well microplate reader:</strong></h2>
<figure id="attachment_13601" aria-describedby="caption-attachment-13601" style="width: 1024px" class="wp-caption alignnone"><img fetchpriority="high" decoding="async" class="wp-image-13601 size-large" src="https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-1024x975.webp" alt="Automatic Elisa Plate Reader, 96 Wells Plate" width="1024" height="975" srcset="https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-1024x975.webp 1024w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-300x286.webp 300w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-768x731.webp 768w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-1536x1462.webp 1536w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-600x571.webp 600w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I.webp 1836w" sizes="(max-width: 1024px) 100vw, 1024px" /><figcaption id="caption-attachment-13601" class="wp-caption-text">Automatic Elisa Plate Reader, 96 Wells Plate</figcaption></figure>
<figure id="attachment_13597" aria-describedby="caption-attachment-13597" style="width: 873px" class="wp-caption alignnone"><img decoding="async" class="wp-image-13597 size-large" src="https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-1-873x1024.webp" alt="Automatic Elisa Plate Reader, 96 Wells Plate" width="873" height="1024" srcset="https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-1-873x1024.webp 873w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-1-256x300.webp 256w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-1-768x901.webp 768w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-1-1310x1536.webp 1310w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-1-1746x2048.webp 1746w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-1-600x704.webp 600w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-1.webp 1836w" sizes="(max-width: 873px) 100vw, 873px" /><figcaption id="caption-attachment-13597" class="wp-caption-text">Power connector and data transfer port for easy connection of the 96 well microplate reader to power supply and external computer.</figcaption></figure>
<figure id="attachment_13598" aria-describedby="caption-attachment-13598" style="width: 1024px" class="wp-caption alignnone"><img decoding="async" class="wp-image-13598 size-large" src="https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-2-1024x461.webp" alt="Automatic Elisa Plate Reader, 96 Wells Plate" width="1024" height="461" srcset="https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-2-1024x461.webp 1024w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-2-300x135.webp 300w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-2-768x346.webp 768w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-2-1536x691.webp 1536w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-2-2048x922.webp 2048w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-2-600x270.webp 600w" sizes="(max-width: 1024px) 100vw, 1024px" /><figcaption id="caption-attachment-13598" class="wp-caption-text">This elisa reader is equipped with a high-definition color display for intuitive viewing of test results and device status</figcaption></figure>
<figure id="attachment_13599" aria-describedby="caption-attachment-13599" style="width: 1024px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-13599 size-large" src="https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-3-1024x789.webp" alt="Automatic Elisa Plate Reader, 96 Wells Plate" width="1024" height="789" srcset="https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-3-1024x789.webp 1024w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-3-300x231.webp 300w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-3-768x592.webp 768w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-3-1536x1184.webp 1536w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-3-2048x1579.webp 2048w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-3-600x463.webp 600w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /><figcaption id="caption-attachment-13599" class="wp-caption-text">Automatic Elisa Plate Reader, 96 Wells Plate</figcaption></figure>
<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-13600" src="https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-4-300x211.webp" alt="" width="300" height="211" srcset="https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-4-300x211.webp 300w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-4-1024x720.webp 1024w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-4-768x540.webp 768w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-4-1536x1080.webp 1536w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-4-2048x1441.webp 2048w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-96I-4-600x422.webp 600w" sizes="auto, (max-width: 300px) 100vw, 300px" /></p>
<p>&nbsp;</p>
<h2><strong>Absorbance assay:</strong></h2>
<p>Working Principle: Absorbance detection is used to quantitatively analyze the amount of biomolecules in a sample by measuring the light absorption value of the sample at a specific wavelength. When light passes through the sample, the sample absorbs a certain amount of light energy, and the remaining light energy is measured by the detector to calculate the absorbance value of the sample.</p>
<p>Application Scenario: Absorbance assay is widely used in enzyme-linked immunosorbent assay (ELISA) technology to determine the concentration of biological molecules such as nucleic acids and proteins. In addition, it is used in biological studies such as cell proliferation and toxicity detection.</p>
<p>The post <a href="https://keylaser.am/product/automatic-elisa-plate-reader-96-wells-plate/">Automatic Elisa Plate Reader, 96 Wells Plate</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Elisa Microplate Reader, 96/48-well Plate</title>
		<link>https://keylaser.am/product/elisa-microplate-reader-96-48-well-plate/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 20 Mar 2025 16:23:31 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=13586</guid>

					<description><![CDATA[<p><strong>Model : ELMR-200I</strong></p>
<div>
<div></div>
<div>Wavelength Range : 400-800nm<br />
Repeatability : ≤0.2%</div>
<div>Accuracy : ±0.008A</div>
<div>Sizes(W×D×H)(mm) : 475×350×210</div>
<div>This elisa microplate reader is suitable for research and routine ELISA applications.</div>
</div>
<p>The post <a href="https://keylaser.am/product/elisa-microplate-reader-96-48-well-plate/">Elisa Microplate Reader, 96/48-well Plate</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2><strong>Elisa Microplate Reader Specifications:</strong></h2>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="610">
<thead>
<tr class="firstRow">
<th>Model</th>
<th>ELMR-200I</th>
</tr>
</thead>
<tbody>
<tr>
<td>Microplate Types</td>
<td>96/48-well plate</td>
</tr>
<tr>
<td>Photodetector</td>
<td>Silicon photodiode</td>
</tr>
<tr>
<td>Light Source</td>
<td>8v/50w controlled tungsten halogen lamp</td>
</tr>
<tr>
<td>Wavelength Range</td>
<td>400nm~800nm</td>
</tr>
<tr>
<td>Standard Filters</td>
<td>405, 450, 492, 630nm &amp; 4 optional</td>
</tr>
<tr>
<td>Reading Range</td>
<td>0.000~4.000A</td>
</tr>
<tr>
<td>Resolution</td>
<td>0.001A</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±0.008A</td>
</tr>
<tr>
<td>Reproducibility</td>
<td>≤0.2%</td>
</tr>
<tr>
<td>Stability</td>
<td>±0.003A</td>
</tr>
<tr>
<td>Reading Speed</td>
<td>Single wavelength≤3s; Double wavelength≤6s</td>
</tr>
<tr>
<td>Shaking</td>
<td>Linear shaking, 3 speeds</td>
</tr>
<tr>
<td>Printer</td>
<td>Built-in thermal printer, optional external printer</td>
</tr>
<tr>
<td>Interface Connections</td>
<td>2×USB-A, 1×USB-B, 1×RS-232, 1×Printer</td>
</tr>
<tr>
<td>Power Supply</td>
<td>100~240V, 50~60Hz</td>
</tr>
<tr>
<td>Sizes(W×D×H)(mm)</td>
<td>475×350×210</td>
</tr>
<tr>
<td>Shipping Size(W×D×H)(mm)</td>
<td>590×450×350</td>
</tr>
<tr>
<td>N.W./G.W. (kg)</td>
<td>9/13</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>&nbsp;</p>
<h2><strong>Elisa Microplate Reader Features:</strong></h2>
<p>&nbsp;</p>
<p>This elisa microplate reader has high sensitivity and accuracy and is equipped with automation features to make experimental operations more convenient and efficient. It is widely used in medical, biological and biotechnological research for diagnosing diseases, monitoring protein interactions, drug screening and other fields.</p>
<ol class=" list-paddingleft-2">
<li>Ultra-fast readings for absorbance, transmission, concentration and qualitative studies. Self-diagnostic system and alarm.</li>
<li>10.4-inch capacitive touch screen that can work alone or through a PC.</li>
<li>Flexible board layout with blank, standard, sample, reference, and QC on one screen.</li>
<li>Equipped with 405nm, 450nm, 492nm, 630nm and 4 position mounting.</li>
<li>Over 20 different report formats.</li>
<li>Comprehensive qualitative and quantitative data evaluation capabilities with cut-offs, curve fitting and conversion formulas.</li>
<li>Eight-channel optics for fast readout.</li>
<li>Automatic light tuning and auto-calibration.</li>
<li>Reference channel with optimized light intensity ensures reliable results.</li>
</ol>
<h2><strong>Details of Elisa Microplate Reader:</strong></h2>
<figure id="attachment_13587" aria-describedby="caption-attachment-13587" style="width: 1024px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-13587 size-large" src="https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-1-1024x630.webp" alt="Elisa Microplate Reader, 96/48-well Plate" width="1024" height="630" srcset="https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-1-1024x630.webp 1024w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-1-300x184.webp 300w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-1-768x472.webp 768w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-1-1536x944.webp 1536w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-1-2048x1259.webp 2048w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-1-600x369.webp 600w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /><figcaption id="caption-attachment-13587" class="wp-caption-text">Elisa Microplate Reader, 96/48-well Plate</figcaption></figure>
<figure id="attachment_13588" aria-describedby="caption-attachment-13588" style="width: 1024px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-13588 size-large" src="https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-2-1024x656.webp" alt="Elisa Microplate Reader, 96/48-well Plate" width="1024" height="656" srcset="https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-2-1024x656.webp 1024w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-2-300x192.webp 300w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-2-768x492.webp 768w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-2-1536x983.webp 1536w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-2-2048x1311.webp 2048w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-2-600x384.webp 600w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /><figcaption id="caption-attachment-13588" class="wp-caption-text">Elisa Microplate Reader, 96/48-well Plate</figcaption></figure>
<figure id="attachment_13589" aria-describedby="caption-attachment-13589" style="width: 1024px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-13589 size-large" src="https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-3-1024x461.webp" alt="Elisa Microplate Reader, 96/48-well Plate" width="1024" height="461" srcset="https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-3-1024x461.webp 1024w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-3-300x135.webp 300w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-3-768x346.webp 768w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-3-1536x691.webp 1536w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-3-2048x922.webp 2048w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-3-600x270.webp 600w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /><figcaption id="caption-attachment-13589" class="wp-caption-text">Elisa Microplate Reader, 96/48-well Plate</figcaption></figure>
<figure id="attachment_13590" aria-describedby="caption-attachment-13590" style="width: 1024px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-13590 size-large" src="https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-4-1024x461.webp" alt="Elisa Microplate Reader, 96/48-well Plate" width="1024" height="461" srcset="https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-4-1024x461.webp 1024w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-4-300x135.webp 300w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-4-768x346.webp 768w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-4-1536x691.webp 1536w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-4-2048x922.webp 2048w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-4-600x270.webp 600w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /><figcaption id="caption-attachment-13590" class="wp-caption-text">Elisa Microplate Reader, 96/48-well Plate</figcaption></figure>
<figure id="attachment_13591" aria-describedby="caption-attachment-13591" style="width: 1024px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-13591 size-large" src="https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-5-1024x461.webp" alt="Elisa Microplate Reader, 96/48-well Plate" width="1024" height="461" srcset="https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-5-1024x461.webp 1024w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-5-300x135.webp 300w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-5-768x346.webp 768w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-5-1536x691.webp 1536w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-5-2048x922.webp 2048w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-5-600x270.webp 600w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /><figcaption id="caption-attachment-13591" class="wp-caption-text">Elisa Microplate Reader, 96/48-well Plate</figcaption></figure>
<figure id="attachment_13592" aria-describedby="caption-attachment-13592" style="width: 1024px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-13592 size-large" src="https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-6-1024x760.webp" alt="Elisa Microplate Reader, 96/48-well Plate" width="1024" height="760" srcset="https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-6-1024x760.webp 1024w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-6-300x223.webp 300w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-6-768x570.webp 768w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-6-1536x1140.webp 1536w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-6-2048x1520.webp 2048w, https://keylaser.am/wp-content/uploads/2025/03/ELMR-200I-6-600x445.webp 600w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /><figcaption id="caption-attachment-13592" class="wp-caption-text">Elisa Microplate Reader, 96/48-well Plate</figcaption></figure>
<p>The post <a href="https://keylaser.am/product/elisa-microplate-reader-96-48-well-plate/">Elisa Microplate Reader, 96/48-well Plate</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
