<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>ELISA Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-tag/elisa/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-tag/elisa/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Tue, 17 Mar 2026 11:51:30 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>ELISA Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-tag/elisa/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ELISA Microplate Reader BK-EL10E</title>
		<link>https://keylaser.am/product/elisa-microplate-reader-bk-el10e/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 17 Mar 2026 11:51:30 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14649</guid>

					<description><![CDATA[<p><label>Model: </label>BK-EL10E</p>
<p>Elisa reader is a kind of analytical instrument widely used in biology, clinical and other fields.</p>
<p>The post <a href="https://keylaser.am/product/elisa-microplate-reader-bk-el10e/">ELISA Microplate Reader BK-EL10E</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1. 96-well full wavelength scanning, wavelength range 190nm~1000nm.</p>
<p>2. No need to preheat when starting up, can be detected directly.</p>
<p>3. 10.1-inch color touch screen, visual free layout, improve user operation experience.</p>
<p>4. Comes with incubation heating function.</p>
<p>5. Comes with microplate oscillation mixing function, no need to use an external shaker.</p>
<p>6. Suitable for all light absorption and turbidity research applications, supports spectral scanning, endpoint method, and kinetic method.</p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BK-EL10E</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Detection Method</td>
<td>96-well full wavelength scanning</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Detection Speed</td>
<td>Complete 96-well plate detection within 20 seconds</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Plate Layout Method</td>
<td>Visual free layout</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Wavelength Range</td>
<td>190nm~1000nm(1nm step)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Light Source</td>
<td>Flashing xenon lamp</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Spectral Bandwidth</td>
<td>2.5nm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Accuracy</td>
<td>1.0%±0.005Abs(0~2.0Abs)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Precision</td>
<td>OD accuracy 1.0%+0.003OD(0~2.0 OD); 2.0%(2.0~2.5 OD)@450nm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Incubation Temperature</td>
<td>RT+2~65℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Shaking Function</td>
<td>Shaking mode, shaking speed and shaking time are adjustable</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Microplate Type</td>
<td>96-well microplate</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Display</td>
<td>10.1-inch color touch screen</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Storage Capacity</td>
<td>&gt;20,000 samples</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Power</td>
<td>120VA</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power Supply</td>
<td>AC100~240V, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Instrument Size(W*D*H)</td>
<td>340*430*400mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="1" rowspan="1">Package Size(W*D*H)</td>
<td colspan="1" rowspan="1">440*610*475mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net/Gross Weight</td>
<td>12/21kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/elisa-microplate-reader-bk-el10e/">ELISA Microplate Reader BK-EL10E</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Auto ELISA Processor BIOBASE8001</title>
		<link>https://keylaser.am/product/auto-elisa-processor-biobase8001/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 17 Mar 2026 09:12:49 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14604</guid>

					<description><![CDATA[<p><label>Model: </label>BIOBASE8001</p>
<p>Auto ELISA Processor BIOBASE8001 is a fully automatic detection equipment that integrates sample addition, incubation, shaking, washing, and reading. It is widely used in hospital laboratories, disease prevention and control centers, blood centers, and blood banks, animal and plant inspection and quarantine institutions, scientific research institutions, university laboratories and other places.</p>
<p>The post <a href="https://keylaser.am/product/auto-elisa-processor-biobase8001/">Auto ELISA Processor BIOBASE8001</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. 8 sampling channels, 16 incubation boards, 3 washers.</p>
<p>2. Adopt the principle of pressure type liquid detection.</p>
<p>3. With TIP detection, clot detection function.</p>
<p>4. High-precision pipetting, the lowest volume can reach 5μl.</p>
<p>5. Position sensing, real-time monitoring of gripper status.</p>
<p>6. Multi-spacing and multi-strength adjustable grippers can be adapted to grasp and place microplates and plate covers of different sizes.</p>
<p>7. Dual thread control, can run simultaneously with the sampling arm without interfering with each other.</p>
<figure id="attachment_14605" aria-describedby="caption-attachment-14605" style="width: 1200px" class="wp-caption alignnone"><img fetchpriority="high" decoding="async" class="wp-image-14605 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/8001.webp" alt="Auto ELISA Processor BIOBASE8001" width="1200" height="665" srcset="https://keylaser.am/wp-content/uploads/2026/03/8001.webp 1200w, https://keylaser.am/wp-content/uploads/2026/03/8001-300x166.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/8001-1024x567.webp 1024w, https://keylaser.am/wp-content/uploads/2026/03/8001-768x426.webp 768w, https://keylaser.am/wp-content/uploads/2026/03/8001-600x333.webp 600w" sizes="(max-width: 1200px) 100vw, 1200px" /><figcaption id="caption-attachment-14605" class="wp-caption-text">Auto ELISA Processor BIOBASE8001</figcaption></figure>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="2">BIOBASE8001</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="7">Sample&amp;Reagent Unit</td>
<td>Sample Racks</td>
<td>12*20 push-pull sample rack with detection</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sampling Channel</td>
<td>8 channels</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Liquid Level Detection</td>
<td>Air pressure level detection, needle blocking intelligent detection</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>TIP</td>
<td>5 TIP racks</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Pipetting</td>
<td>5~1000μl, capable of parallel sampling</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Pipetting Precision</td>
<td>100μl: CV≤1.0%, accuracy≤2.5%</p>
<p>1000μl: CV≤0.5%, accuracy≤1.0%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Position</td>
<td>6 reagent positions, 40 quality control positions +12 reagent bottles +25 reagent tanks(reagent tank with code identification)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Washing Unit</td>
<td>Washer</td>
<td>3 units with on plate detection function</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Washing Head</td>
<td>16-channel(32-pin), double row cleaning, hanging installation, with leakage recovery</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Injection Uniformity</td>
<td>CV&lt;1.5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Washing Residual</td>
<td>&lt;1μl(residual volume per well)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="8">Reading Unit</td>
<td>Reading Channel</td>
<td>8 independent photometric channels</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Linear Range</td>
<td>0.000~3.000Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Repeatability</td>
<td>CV≤1.0%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Stability</td>
<td>≤±0.003Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Optical Filters</td>
<td>4 standard filters(405, 450, 492, 630nm)</p>
<p>Total 10 filters positions</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reading Accuracy</td>
<td>≤±0.02Abs from 0.0 to 1.0 OD,</p>
<p>≤±0.03Abs from 1.0 to 2.0 OD</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sensitivity</td>
<td>≥0.01mg/L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Channel Difference</td>
<td>≤0.02Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="7">Incubation Unit</td>
<td>Incubators</td>
<td>16 shaking incubators</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Cover Positions</td>
<td>4(16 covers)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Heating Method</td>
<td>Dry heating with cover</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Shaking Function</td>
<td>Horizontal circular oscillation, 1~3 levels adjustable, amplitude 2.5mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temperature Range</td>
<td>RT~60 °C</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature Uniformity</td>
<td>±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temperature Fluctuation</td>
<td>±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="5">Data Management</td>
<td>Software</td>
<td>Above Windows 7 system</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>LIS System</td>
<td>Bi-direction, support HL7 protocol</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Results</td>
<td>Absorbance and results reviewable by software</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Printer</td>
<td>External optional</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Built-in Scanner</td>
<td>Optional</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Other Function</td>
<td>Biosafety Protection</td>
<td>Optional(Negative pressure working zone, HEPA filter)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Disinfection</td>
<td>UV lamp</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Lighting</td>
<td>LED</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>IAP Function</td>
<td>Firmware can be upgraded online at any time</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Working Condition</td>
<td>Power Supply</td>
<td>AC100~240V, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature</td>
<td>10~30℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Humidity</td>
<td>40~70%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4">Size&amp;Weight</td>
<td>External Size(W*D*H)</td>
<td>Machine: 1925*824*1652mm</p>
<p>Base Stand: 1925*792*777mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Package Size(W*D*H)</td>
<td>Machine: 2095*950*1160mm</p>
<p>Base stand: 2095*950*1005mm</p>
<p>Accessories: 1560*930*530mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Net Weight</td>
<td>Machine: 320kg</p>
<p>Base stand: 153kg</p>
<p>Accessories: 68kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>Machine: 420kg</p>
<p>Base stand: 245kg</p>
<p>Accessories: 122kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/auto-elisa-processor-biobase8001/">Auto ELISA Processor BIOBASE8001</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Auto ELISA Processor BIOBASE1000</title>
		<link>https://keylaser.am/product/11358/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 14:14:08 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11358</guid>

					<description><![CDATA[<p><strong>Introduction:</strong></p>
<p>The auto elisa processor is an analytical instrument used in the field of hospital, laboratory. Its main function is to analyze sample pre-processing, sample analysis and data processing.</p>
<p>The post <a href="https://keylaser.am/product/11358/">Auto ELISA Processor BIOBASE1000</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BIOBASE 1000</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1. 1 robotic arm, 1 pipetting probe(10~1000μl).</p>
<p>2. 2 units 96 well microplates(independent incubating).</p>
<p>3. 1 unit reader&amp;washer(auto reading and washing).</p>
<p>&nbsp;</p>
<p><img decoding="async" class="wp-image-11355 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/Biobase1000.webp" alt="Auto ELISA Processor BIOBASE1000" width="1247" height="451" srcset="https://keylaser.am/wp-content/uploads/2024/10/Biobase1000.webp 1247w, https://keylaser.am/wp-content/uploads/2024/10/Biobase1000-300x109.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/Biobase1000-1024x370.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/Biobase1000-768x278.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/Biobase1000-600x217.webp 600w" sizes="(max-width: 1247px) 100vw, 1247px" /><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="2">BIOBASE1000</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="3">Sample Unit</td>
<td>Sample Racks</td>
<td>Standard 192 sample position (expandable, up to 384)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Pipetting</td>
<td>10~1000μl</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Dispensing System</td>
<td>1 aspirating-dispensing probe(X-Y-Z movement)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Reagent Unit</td>
<td>Reagent Racks</td>
<td>Universal reagent position: Standard 6 universal reagent positions(expandable, up to 32);</p>
<p>Original reagent bottle: Standard 20 reagent bottles position(expandable, up to 80)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Pipetting Range</td>
<td>10~1000μl, 1μl stepping</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Pipetting Precision</td>
<td>(100μl)CV≤0.5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Dispensing Time</td>
<td>5 minutes to whole 96 well microplates</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Incubation Unit</td>
<td>Incubation</td>
<td>2 independent incubators</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature Range</td>
<td>RT to 45 °C</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temperature Accuracy</td>
<td>±0.5°C</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="3">Washing Unit</td>
<td>Washing Probes</td>
<td>Two line 8-nozzle manifolds</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Wash Containers</td>
<td>2 wash buffers 2L, 1 distilled water, 1 waste water</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Washing Residual</td>
<td>&lt;2μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Reading Unit</td>
<td>Reading Channels</td>
<td>8 independent photometric channels, mono and dichromatic reading</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Absorbance</td>
<td>0.0~3.0OD</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Spectral Range</td>
<td>400~700nm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Optical Filters</td>
<td>2 standard filters(450, 630nm);</p>
<p>2 more on request(405nm/450nm/492nm/630nm)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Data Management</td>
<td>Software</td>
<td>Windows 7</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>LIS System</td>
<td>Bi-direction, support HL7 protocol</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Results</td>
<td>Absorbance and results reviewable by software</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Printer</td>
<td>External optional</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Working Conditions</td>
<td>Power Supply</td>
<td>AC220V±10%, 50/60Hz; 110V±10%, 60Hz, 400W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature</td>
<td>10~30℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Humidity</td>
<td>30~80%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4">Size&amp;Weight</td>
<td>External Size (W*D*H)</td>
<td>933*685*860mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>130kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size (W*D*H)</td>
<td>1085*840*1318mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>180kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/11358/">Auto ELISA Processor BIOBASE1000</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Auto ELISA Processor BIOBASE2000</title>
		<link>https://keylaser.am/product/auto-elisa-processor-biobase2000/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 14:08:43 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11342</guid>

					<description><![CDATA[<p><strong>Introduction:</strong></p>
<p>The auto elisa processor is an analytical instrument used in the field of hospital, laboratory. Its main function is to analyze sample pre-processing, sample analysis and data processing.</p>
<p>The post <a href="https://keylaser.am/product/auto-elisa-processor-biobase2000/">Auto ELISA Processor BIOBASE2000</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BIOBASE 2000</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<div class="ast-oembed-container " style="height: 100%;"><iframe title="BIOBASE 2000 Auto Elisa Processor" width="1778" height="1000" src="https://www.youtube.com/embed/B4J2hYPz2KI?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
<p>&nbsp;</p>
<p><strong>Features:</strong></p>
<p>1. 1 robotic arm, 2 pipetting probes(10~1000μl).</p>
<p>2. 4 units 96 well microplates(independent incubating).</p>
<p>3. 1 unit reader&amp;washer(auto reading and washing).</p>
</div>
<p>&nbsp;</p>
<p><img loading="lazy" decoding="async" class="wp-image-11343 size-large" src="https://keylaser.am/wp-content/uploads/2024/10/01-1-1024x374.webp" alt="Auto ELISA Processor BIOBASE2000" width="1024" height="374" srcset="https://keylaser.am/wp-content/uploads/2024/10/01-1-1024x374.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/01-1-300x110.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/01-1-768x281.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/01-1-600x219.webp 600w, https://keylaser.am/wp-content/uploads/2024/10/01-1.webp 1113w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /></p>
<div class="prodDetail-editor-container">
<p><strong>Technical Parameters:</strong></p>
<div>
<div>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="2">BIOBASE2000</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="3">Sample Unit</td>
<td>Sample Racks</td>
<td>Standard 192 sample positions(expandable, up to 552)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Pipetting</td>
<td>10~1000μl</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Dispensing System</td>
<td>2 aspirating and dispensing probe( X-Y-Z movement)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Reagent Unit</td>
<td>Reagent Position</td>
<td>23 reagent racks, editable</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Pipetting Range</td>
<td>10~1000μl,  1μl stepping</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Pipetting Precision</td>
<td>(100μl)CV≤0.5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="5">Washing Unit</td>
<td>Dispensing Time</td>
<td>4 minutes to whole 96 to microplates</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Washing Probes</td>
<td>Two line 8-nozzle manifolds</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Wash Containers</td>
<td>Cleaning fluid(15L), waste water(25L), Buffer 1(5L),  Buffer 2(2L),</p>
<p>Buffer 3(2L),  Buffer 4(2L), with liquid level-sensing, liquid shortage and full alarm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Waste Containers</td>
<td>25L with waste full sensor</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Washing Residual</td>
<td>&lt;2μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="5">Reading Unit</td>
<td>Reading Channels</td>
<td>8 independent photometric channels,  mono anddichromatic reading</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Absorbance</td>
<td>0.0~3.0OD</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Spectral Range</td>
<td>400~700nm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Optical Filters</td>
<td>2 standard filters(450, 630nm); 2 more on request (405nm/450nm/492nm/630nm)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Reading Accuracy</td>
<td>±1% from 0~1.5OD, ±2% from 1.5~3.0OD</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="3">Incubation Unit</td>
<td>Incubators</td>
<td>4 independent units</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temperature Range</td>
<td>RT to 45℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature Accuracy</td>
<td>±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Data Management</td>
<td>Software System</td>
<td>Above Windows 7 system</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>LIS System</td>
<td>Bi-direction, support HL7 protocol</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Results</td>
<td>Absorbance and results reviewable by software</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Printer</td>
<td>External optional</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Working Conditions</td>
<td>Power Supply</td>
<td>AC220V±10%, 50/60Hz; 110V±10%, 60Hz, 400W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature</td>
<td>10~30℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Humidity</td>
<td>30%~80%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4">Size&amp;Weight</td>
<td>External Size (W*D*H)</td>
<td>1235*705*875mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>146kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size (W*D*H)</td>
<td>1380*860*1435mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>220kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/auto-elisa-processor-biobase2000/">Auto ELISA Processor BIOBASE2000</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Auto ELISA Processor BIOBASE2001</title>
		<link>https://keylaser.am/product/auto-elisa-processor-biobase2001/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 14:05:16 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11333</guid>

					<description><![CDATA[<p><strong>Introduction:</strong><br />
Auto ELISA Processor BIOBASE2001 is a fully automaticdetection equipment that integrates sample addition,incubation, shaking, washing, and reading. lt is widely usedin hospital laboratories, disease prevention and controlcenters, blood centers, and blood banks, animal and plantinspection and quarantine institutions, scientific researchinstitutions, university laboratories and other places.</p>
<p>The post <a href="https://keylaser.am/product/auto-elisa-processor-biobase2001/">Auto ELISA Processor BIOBASE2001</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BIOBASE2001</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1. Adopt the principle of pressure type liquid detection</p>
<p>2. With TIP detection, clot detection function</p>
<p>3. High-precision pipetting</p>
<p>4. Position sensing, real-time monitoring of gripper status</p>
<p>5. Multi-spacing and multi-strength adjustable grippers can be adapted to grasp and place microplates and plate covers of different sizes</p>
<p>6. Dual thread control, can run simultaneously with the sampling arm without interfering with each other</p>
<p>&nbsp;</p>
</div>
<figure id="attachment_11334" aria-describedby="caption-attachment-11334" style="width: 1212px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-11334 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/BIOBASE2001-1.webp" alt="Auto ELISA Processor BIOBASE2001" width="1212" height="816" srcset="https://keylaser.am/wp-content/uploads/2024/10/BIOBASE2001-1.webp 1212w, https://keylaser.am/wp-content/uploads/2024/10/BIOBASE2001-1-300x202.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/BIOBASE2001-1-1024x689.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/BIOBASE2001-1-768x517.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/BIOBASE2001-1-600x404.webp 600w" sizes="auto, (max-width: 1212px) 100vw, 1212px" /><figcaption id="caption-attachment-11334" class="wp-caption-text"> </figcaption></figure>
<p>&nbsp;</p>
<div class="prodDetail-editor-container">
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="2">BIOBASE2001</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="7">Sample&amp;Reagent Unit</td>
<td>Sample Racks</td>
<td>6*20 push-pull sample rack with detection</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sample Channel</td>
<td>2 channels</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Liquid Level Detection</td>
<td>Air pressure level detection, clot detection function</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Tip</td>
<td>1000μl, 3 tip racks</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Pipetting</td>
<td>10μl~1000μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Pipetting Precision</td>
<td>100μl: CV≤1%, Accuracy≤2.5%</p>
<p>1000μl: CV≤0.5%, Accuracy≤1%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Position</td>
<td>4 reagent racks, reagent tanks with detection</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Washing Unit</td>
<td>Washer</td>
<td>1 unit</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Washing Head</td>
<td>16-channel(32-pin), double row cleaning, hanging installation, with leakage recovery</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Injection Uniformity</td>
<td>CV&lt;1.5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Washing Residual</td>
<td>&lt;1μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="8">Reading Unit</td>
<td>Reading Channels</td>
<td>8 independent photometric channels</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Linear Range</td>
<td>0.000~3.000Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Repeatability</td>
<td>CV≤1.0%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Stability</td>
<td>≤±0.003Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Optical Filters</td>
<td>4 standard filters(405, 450, 492, 630nm);</p>
<p>Total 10 filters positions</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reading Accuracy</td>
<td>≤±0.02Abs from 0.0 to 1.0OD</p>
<p>≤±0.03Abs from 1.0 to 2.0OD</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sensitivity</td>
<td>≥0.01mg/L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Channel Difference</td>
<td>≤0.02Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="7">Incubation Unit</td>
<td>Incubators</td>
<td>8 shaking incubators</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Cover Positions</td>
<td>1(8 covers)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Heating Method</td>
<td>Dry heating with cover</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Shaking Function</td>
<td>Horizontal circular oscillation, 1-3 levels adjustable, amplitude 2.5mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temperature Range</td>
<td>RT to 60 °C</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature Uniformity</td>
<td>0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temperature Fluctuation</td>
<td>±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="5">Data Management</td>
<td>Software</td>
<td>Above Windows 7 system</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>LIS System</td>
<td>Bi-direction, support HL7 protocol</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Results</td>
<td>Absorbance and results reviewable by software</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Printer</td>
<td>External optional</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Built-in Scanner</td>
<td>Optional</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Other Function</td>
<td>Biosafety Protection</td>
<td>Optional (Negative pressure working zone, HEPA filter)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Disinfection</td>
<td>UV lamp</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Lighting</td>
<td>LED</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>IAP Function</td>
<td>Firmware can be upgraded online at any time</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Working Condition</td>
<td>Power Supply</td>
<td>AC220V±10%, 50/60Hz(Standard); 110V±10%, 60Hz( Optional)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature</td>
<td>10~40℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Humidity</td>
<td>30~80%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4">Size&amp;Weight</td>
<td>External Size (W*D*H)</td>
<td>1275*750*1650mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>330kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size(W*D*H)mm</td>
<td>Machine: 1445*1130*920</p>
<p>Base Stand: 1445*1005*920</p>
<p>Accessories: 1065*510*895</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight(kg)</td>
<td>Machine: 220</p>
<p>Base Stand: 125</p>
<p>Accessories: 30</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/auto-elisa-processor-biobase2001/">Auto ELISA Processor BIOBASE2001</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Auto ELISA Processor BIOBASE1001</title>
		<link>https://keylaser.am/product/auto-elisa-processor-biobase1001/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 14:00:03 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11324</guid>

					<description><![CDATA[<p><strong>Introduction:</strong><br />
The Auto ELISA Processor BIOBASE1001 is a fully automatic detection equipment that integrates sample addition, incubation, shaking, washing, and reading. It is widely used in hospital laboratories, disease prevention and control centers, blood centers, and blood banks. , animal and plant inspection and quarantine institutions, scientific research institutions, university laboratories and other places.</p>
<p>The post <a href="https://keylaser.am/product/auto-elisa-processor-biobase1001/">Auto ELISA Processor BIOBASE1001</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BIOBASE1001</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1. Adopt the principle of pressure type liquid detection</p>
<p>2. With TIP detection, clot detection function</p>
<p>3. High-precision pipetting, the lowest volume can reach 10μl</p>
<p>4. Position sensing, real-time monitoring of gripper status</p>
<p>5. Multi-spacing and multi-strength adjustable grippers can be adapted to grasp and place microplates and plate covers of different sizes</p>
<p>6. Dual thread control, can run simultaneously with the sampling arm without interfering with each other</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="882">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="2" width="71">BIOBASE1001</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="8" width="71">Sample&amp; Reagent Unit</td>
<td width="79">Sample Racks</td>
<td>6*20 push-pull sample rack</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Sampling Channel</td>
<td width="458">1 channel</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="221">Liquid Level Detection</td>
<td width="458">Air pressure level detection, clot detection function</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Tip</td>
<td width="458">1000μl, 2 tip racks</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Pipetting</td>
<td width="458">10μl~1000μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Pipetting Precision</td>
<td width="458">100μl: CV≤1%, Accuracy≤2.5%</p>
<p>1000μl: CV≤0.5%, Accuracy≤1%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Reagent Position</td>
<td width="458">2 reagent racks</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Dilution Plate Position</td>
<td width="458">1 dilution plate position with incubation and shaking</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4" width="71">Washing Unit</td>
<td width="79">Washer</td>
<td>1 unit</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Washing Head</td>
<td width="458">16-channel (32-pin), double row cleaning, hanging installation, with leakage recovery</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Injection Uniformity</td>
<td width="458">CV&lt;1.5%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Washing Residual</td>
<td width="458">&lt;2μl</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="10" width="71">Reading Unit</td>
<td width="79">Reading Channels</td>
<td>8 independent photometric channels, mono and dichromatic reading</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Absorbance Range</td>
<td width="458">0.000~4.000Abs</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Linear Range</td>
<td width="458">0.000~3.000Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Repeatability</td>
<td width="458">CV≤1.0%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Stability</td>
<td width="458">≤±0.003Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Spectral Range</td>
<td width="458">400~700nm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Optical Filters</td>
<td width="458">4 standard filters(405, 450, 492, 630nm);</p>
<p>Total 10 filters positions</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Reading Accuracy</td>
<td width="458">≤±0.02Abs from 0.0 to 1.0 OD,</p>
<p>≤±0.03Abs from 1.0 to 2.0 OD</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Sensitivity</td>
<td width="458">≥0.01mg/L</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Channel Difference</td>
<td width="458">≤0.02Abs</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="7" width="71">Incubation Unit</td>
<td width="79">Incubators</td>
<td>2 shaking incubators</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Cover Position</td>
<td width="458">1 (2 covers)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Heating Method</td>
<td width="458">Dry heating with cover</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Shaking Function</td>
<td width="458">Horizontal circular oscillation, 1-3 levels adjustable, amplitude 2.5mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Temperature Range</td>
<td width="458">RT to 60 °C</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Temperature Uniformity</td>
<td width="458">±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Temperature Fluctuation</td>
<td width="458">±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="5" width="71">Data Management</td>
<td width="79">Software</td>
<td>Above Windows 7 system</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">LIS System</td>
<td width="458">Bi-direction, support HL7 protocol</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Results</td>
<td width="458">Absorbance and results reviewable by software</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Printer</td>
<td width="458">External optional</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Built-in Scanner</td>
<td width="458">Optional</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4" width="71">Other Function</td>
<td width="79">Biosafety Protection</td>
<td>Optional (Negative pressure working zone, HEPA filter)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Disinfection</td>
<td width="458">UV lamp</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Lighting</td>
<td width="458">LED</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">IAP Function</td>
<td width="458">Firmware can be upgraded online at any time</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="3" width="71">Working Condition</td>
<td width="79">Power Supply</td>
<td>AC220V±10%, 50/60Hz(Standard); 110V±10%, 60Hz(Optional)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Temperature</td>
<td width="458">10~40℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Humidity</td>
<td width="458">30~80%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4" width="71">Size &amp; Weight</td>
<td width="79">External Size (W*D*H)</td>
<td>870*700*885mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Net Weight</td>
<td width="458">180kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="71">Package Size(W*D*H)</td>
<td width="458">Machine: 1018*828*1130mm</p>
<p>Accessories: 750*1000*700mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="71">Gross Weight</td>
<td width="458">Machine: 160kg</p>
<p>Accessories: 80kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/auto-elisa-processor-biobase1001/">Auto ELISA Processor BIOBASE1001</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Auto ELISA Processor BIOBASE4001</title>
		<link>https://keylaser.am/product/auto-elisa-processor-biobase4001/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 13:51:25 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11314</guid>

					<description><![CDATA[<p><strong>Introduction:</strong><br />
Auto ELISA Processor BIOBASE4001 is a fully automatic detection equipment that integrates sample addition, incubation, shaking, washing, and reading. It is widely used in hospital laboratories, disease prevention and control centers, blood centers, and blood banks, animal and plant inspection and quarantine institutions, scientific research institutions, university laboratories and other places.</p>
<p>The post <a href="https://keylaser.am/product/auto-elisa-processor-biobase4001/">Auto ELISA Processor BIOBASE4001</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BIOBASE4001</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1. Adopt the principle of pressure type liquid detection</p>
<p>2. With TIP detection, clot detection function</p>
<p>3. High-precision pipetting, the lowest volume can reach 5μl</p>
<p>4. Position sensing, real-time monitoring of gripper status</p>
<p>5. Multi-spacing and multi-strength adjustable grippers can be adapted to grasp and place microplates and plate covers of different sizes</p>
<p>6. Dual thread control, can run simultaneously with the sampling arm without interfering with each other</p>
</div>
<p>&nbsp;</p>
</div>
<figure id="attachment_11315" aria-describedby="caption-attachment-11315" style="width: 1276px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-11315 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/02-2.webp" alt="Auto ELISA Processor BIOBASE4001" width="1276" height="853" srcset="https://keylaser.am/wp-content/uploads/2024/10/02-2.webp 1276w, https://keylaser.am/wp-content/uploads/2024/10/02-2-300x201.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/02-2-1024x685.webp 1024w, https://keylaser.am/wp-content/uploads/2024/10/02-2-768x513.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/02-2-600x401.webp 600w" sizes="auto, (max-width: 1276px) 100vw, 1276px" /><figcaption id="caption-attachment-11315" class="wp-caption-text"> </figcaption></figure>
<p><strong style="font-size: 16px;">T</strong><strong style="font-size: 16px;">echnical Parameters:</strong></p>
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td colspan="2">BIOBASE4001</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="7">Sample&amp;Reagent Unit</td>
<td>Sample Racks</td>
<td>12*16 push-pull sample rack with detection</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sampling Channel</td>
<td>4 channels</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Liquid Level Detection</td>
<td>Air pressure level detection, clot detection function</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Tip</td>
<td>1000μl, 5 tip racks</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Pipetting</td>
<td>5μl~1000μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Pipetting Precision</td>
<td>100μl: CV≤0.5%, Accuracy≤2.0%</p>
<p>1000μl: CV≤0.5%, Accuracy≤0.5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reagent Position</td>
<td>6 reagent racks, reagent tanks with detection</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Washing Unit</td>
<td>Washer</td>
<td>2 units</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Washing Head</td>
<td>16-channel(32-pin), double row cleaning, hanging installation, with leakage recovery</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Injection Uniformity</td>
<td>CV&lt;1.5%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Washing Residual</td>
<td>&lt;1μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="8">Reading Unit</td>
<td>Reading Channels</td>
<td>8 independent photometric channels, mono and dichromatic reading</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Linear Range</td>
<td>0.000~3.000Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Repeatability</td>
<td>CV≤1.0%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Stability</td>
<td>≤±0.003Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Optical Filters</td>
<td>4 standard filters(405, 450, 492, 630nm)</p>
<p>Total 10 filters positions</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Reading Accuracy</td>
<td>≤±0.02Abs from 0.0 to 1.0OD</p>
<p>≤±0.03Abs from 1.0 to 2.0OD</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sensitivity</td>
<td>≥0.01mg/L</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Channel Difference</td>
<td>≤0.02Abs</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="7">Incubation Unit</td>
<td>Incubators</td>
<td>12 shaking incubators</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Cover Positions</td>
<td>2(12 covers)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Heating Method</td>
<td>Dry heating with cover</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Shaking Function</td>
<td>Horizontal circular oscillation, 1~3 levels adjustable, amplitude 2.5mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temperature Range</td>
<td>RT to 60 °C</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature Uniformity</td>
<td>0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temperature Fluctuation</td>
<td>±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="5">Data Management</td>
<td>Software</td>
<td>Above Windows 7 system</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>LIS System</td>
<td>Bi-direction, support HL7 protocol</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Results</td>
<td>Absorbance and results reviewable by software</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Printer</td>
<td>External optional</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Built-in Scanner</td>
<td>Optional</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="4">Other Function</td>
<td>Biosafety Protection</td>
<td>Optional(Negative pressure working zone, HEPA filter)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Disinfection</td>
<td>UV lamp</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Lighting</td>
<td>LED</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>IAP Function</td>
<td>Firmware can be upgraded online at any time</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="3">Working Condition</td>
<td>Power Supply</td>
<td>AC220V±10%, 50/60Hz(Standard); 110V±10%, 60Hz(Optional)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature</td>
<td>10~40℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Humidity</td>
<td>30~80%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="4">Size&amp;Weight</td>
<td>External Size (W*D*H)</td>
<td>1775*190*1683mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>445kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size(W*D*H)mm</td>
<td>Machine: 1945*950*1150</p>
<p>Base Stand: 1945*950*995</p>
<p>Accessories: 1370*930*530</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight(kg)</td>
<td>Machine: 364.5</p>
<p>Base Stand: 208.5</p>
<p>Accessories: 97</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/auto-elisa-processor-biobase4001/">Auto ELISA Processor BIOBASE4001</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Microplate Shaker BK-MS300</title>
		<link>https://keylaser.am/product/microplate-shaker-bk-ms300/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 13:47:45 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11310</guid>

					<description><![CDATA[<p><strong>Introduction:</strong><br />
BK-MS300 Thermo Shaker for Microplates is a multipurpose thermostatic shaker controlled by brushless DC motor and PID intelligent temperature control technology.The PID fuzzy control technology can be accurate to ensure that the temperature control precision and automatically adjust the heating rate, reduce waiting time.</p>
<p>The post <a href="https://keylaser.am/product/microplate-shaker-bk-ms300/">Microplate Shaker BK-MS300</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BK-MS300</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1. Easy to set up and use, all information real-time display and snowing set up operation, convenient to observe equipment running status.</p>
<p>2. Support standard microplates and deep well plates.</p>
<p>3. Brushless DC motor, low noise, small interference, free maintenance.</p>
<p>4. Automatic preheating function.</p>
<p>5. Automatic power recovery function.</p>
<p>6. Temperature calibration function.</p>
<p>7.Built-in software and hardware over temperature protection device, will use more reliable.</p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BK-MS300</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temp. Setting Range</td>
<td>0~80℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Control Range</td>
<td>RT+5℃~80℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Timing Range</td>
<td>1min~99h59min/∞</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Accuracy</td>
<td>≤±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Display Accuracy</td>
<td>0.1℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp Uniformity</td>
<td>≤±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Shaking Speed</td>
<td>200~1350rpm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Orbit</td>
<td>3mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Auto Preheating</td>
<td>Yes</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Auto Resume to Run</td>
<td>Yes</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Capacity</td>
<td>4 microplates or deep-well plates</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Power Supply</td>
<td>300W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Voltage</td>
<td>AC220V or AC110V, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Heating Time</td>
<td>≤15min(from 25℃ to 80℃)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Dimension</td>
<td>340*320*200mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>9.5kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size(W*D*H)</td>
<td>490*450*315mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>11.5kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/microplate-shaker-bk-ms300/">Microplate Shaker BK-MS300</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Microplate Shaker BK-MS200 BK-MS300</title>
		<link>https://keylaser.am/product/microplate-shaker-bk-ms200/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 13:45:40 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11306</guid>

					<description><![CDATA[<p><label>Model: </label>BK-MS200 BK-MS300</p>
<p>It is with technique of brushless DC motor and PID intelligent temperature control. Mainly used for shaking and cultivation in Elisa plates (96/384 wells) or 96 wells tissue culture plates.</p>
<p>The post <a href="https://keylaser.am/product/microplate-shaker-bk-ms200/">Microplate Shaker BK-MS200 BK-MS300</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features for BK-MS200:</strong></p>
<p>1. LCD displays system status and parameters.</p>
<p>2. Stable and reliable operation with high quality switch.</p>
<p>3. Easy to operate with one touch knob.</p>
<p>4. Set-up the time within 0~100 hours, instrument will make alarm voice when completing.</p>
<p>5. With power recovery, instrument will be continuous to run when power recovers from outage.</p>
<p><strong>Features for BK-MS300:</strong></p>
<p>1. Easy to set up and use, all information real-time display and showing setup operation, convenient to observe equipment running status.</p>
<p>2. Support standard microplates and deep well plates.</p>
<p>3. Brushless DC motor, low noise, small interference, free maintenance.</p>
<p>4. Automatic preheating function.</p>
<p>5. Automatic power recovery function.</p>
<p>6. Temperature calibration function.</p>
<p>7. Built-in software and hardware over temperature protection device, will use more reliable.</p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BK-MS200</td>
<td>BK-MS300</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temp. Setting Range</td>
<td colspan="2">0~80℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Control Range</td>
<td colspan="2">RT+5~80℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Timing Range</td>
<td colspan="2">1min~99h59min/∞</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Accuracy</td>
<td colspan="2">≤±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Display Accuracy</td>
<td colspan="2">0.1℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Uniformity</td>
<td colspan="2">≤±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Shaking Speed</td>
<td>200~1600rpm</td>
<td>200~1350rpm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Orbit</td>
<td colspan="2">3mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Capacity</td>
<td>2pcs of microplates or culture plates</td>
<td>4pcs of microplates or deep-well plates</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Heating Time</td>
<td>≤10min(from RT. to 80℃)</td>
<td>≤15min(from 25℃ to 80℃)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power</td>
<td>150W</td>
<td>300W</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Power Supply</td>
<td colspan="2">220V, 50/60Hz; 110V, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Dimension</td>
<td>280*270*140mm</td>
<td>340*320*200mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>7.0kg</td>
<td>9.5kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Packing Size</td>
<td>410*350*240mm</td>
<td>460*440*300mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>7.8kg</td>
<td>11.08kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/microplate-shaker-bk-ms200/">Microplate Shaker BK-MS200 BK-MS300</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Elisa Microplate Washer</title>
		<link>https://keylaser.am/product/elisa-microplate-washer/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 10 Oct 2024 13:43:27 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=11298</guid>

					<description><![CDATA[<p><strong>Introduction:</strong></p>
<p>The microplate washer is a medical device specially used for cleaning the microplate, and it is generally used in conjunction with the microplate reader. It is mainly used to clean some residues after the detection of the ELISA plate, thereby reducing the error caused by residues in the subsequent detection process. It has been widely used in the cleaning of enzyme-labeled plates in hospitals, blood stations, sanitation and epidemic prevention stations, reagent factories, and research laboratories.</p>
<p>The post <a href="https://keylaser.am/product/elisa-microplate-washer/">Elisa Microplate Washer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="detial-cont-divsions detial-cont-itemspecifics">
<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>BK-9622 BK-9613</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
<div class="ast-oembed-container " style="height: 100%;"><iframe loading="lazy" title="Elisa Microplate Washer BK-9622" width="1778" height="1000" src="https://www.youtube.com/embed/ffHv1kXUEng?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
</div>
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Features:</strong></p>
<p>1. Microcmputer control, automatically complete the plate washing operation.</p>
<p>2. The liquid level sensing function automatically detects the liquid level, and automatically alarms when the cleaning liquid is insufficient and the waste liquid is overflowing.</p>
<p>3. The user-friendly operating system allows users to customize the plate type, set the number of washes, the amount of wash solution, the way to wash the plate, the suction point, the soaking and shaking time and other parameters.</p>
<p>4. The wash head is self-balancing, has two-point aspiration, and performs bottom flushing.</p>
<p>5. 2 kinds of Automatic washing, Soaking and Shaking, to reduce the interference adsorption during the reaction;  time adjustable.</p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BK-9622</td>
<td>BK-9613</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Cleaning Head</td>
<td>8 channels and 12 channels</td>
<td>96 pins, single row controllable</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Microplate Types</td>
<td colspan="2">Four kinds, flat bottom, U bottom, V bottom, round bottom</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Average Residue</td>
<td>&lt;1μl(per hole)</td>
<td>&lt;0.7μl(per hole)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Liquid Suction Time</td>
<td colspan="2">0.1~999.9 seconds adjustable, with an interval of 0.1 seconds</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Line Flush Time</td>
<td colspan="2">1~999 seconds, adjustable</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Washing Programs</td>
<td colspan="2">Up to 200 programs</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Display</td>
<td colspan="2">7-inch touch display</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Liquid Injection Channels</td>
<td colspan="2">3(2 types of lotion and 1 type of distilled water)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Cleaning Needle Position</td>
<td colspan="2">6 types(horizontal, left, middle, right, bottom, hole spacing)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Consumption</td>
<td>80W</td>
<td>350W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power Supply</td>
<td colspan="2">AC220V±10%, 50/60Hz; 110±10%, 60Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Packing Size(W*D*H)</td>
<td>720*480*400mm</td>
<td>740*675*562mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Gross Weight</td>
<td>20kg</td>
<td>42kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/elisa-microplate-washer/">Elisa Microplate Washer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
