<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>faithful Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-tag/faithful/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-tag/faithful/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Thu, 26 Sep 2024 15:54:58 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>faithful Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-tag/faithful/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Climate Chamber with Humidity ControlPlant Growth Chamber</title>
		<link>https://keylaser.am/product/climate-chamber-with-humidity-controlplant-growth-chamber/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 26 Sep 2024 15:54:58 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=9220</guid>

					<description><![CDATA[<p>Light culture of microorganism, cell tissue, seedling, insect and small animal under the control of precise humidity</p>
<ul class="pro-itemspecifics-list fix">
<li><label>Model: </label>FPG250, FPG350, FPG450</li>
<li><label>Brand: </label>FAITHFUL</li>
</ul>
<p>The post <a href="https://keylaser.am/product/climate-chamber-with-humidity-controlplant-growth-chamber/">Climate Chamber with Humidity ControlPlant Growth Chamber</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>●Double door structure, with high quality stalinite to observe sample.</p>
<p>●7.0 inch true color touch screen display, convenient to view historical temperature data and appointment auto start and stop.</p>
<p>● Full spectrum Multi-stage adjustable, 30 sections programmed Temp. LUX ,RH controller.</p>
<p>●Full spectrum LED top light source design, high ilumination, low thermal radiation, long service life, removable Light partition, adjustable layer space.</p>
<p>●Internal humidification system. Small humidifier particles, high humidity uniformity, small water consumption, with automatic water intake, water shortage alarm function.</p>
<p>●The evaporator temperature is collectively controlled by the backflow valve and expansion valve, greatly prolonging the service life of the compressor.</p>
<p>●Imported high quality temperature sensor and compressor.</p>
<p>&nbsp;</p>
<table>
<colgroup>
<col />
<col span="4" /></colgroup>
<tbody>
<tr class="firstRow">
<td colspan="2">Model</td>
<td>FPG250</td>
<td>FPG350</td>
<td>FPG450</td>
</tr>
<tr>
<td colspan="2">Cycle Mode</td>
<td colspan="3">Forced convection, Rear micropore. Supply air in front of the plate</td>
</tr>
<tr>
<td rowspan="7">Function</td>
<td>Temp. Range</td>
<td colspan="3">Without illumination:0～65℃; With illumination:10～65℃</td>
</tr>
<tr>
<td>Temp. Resolution Ratio</td>
<td colspan="3">0.1℃</td>
</tr>
<tr>
<td>Temp.Motion</td>
<td colspan="3">±0.5℃</td>
</tr>
<tr>
<td>Temp. Uniformity</td>
<td colspan="3">±1.0℃</td>
</tr>
<tr>
<td>illumination(LX)</td>
<td colspan="3">Full spectrum 0-30000LX many degrees for adjusting</td>
</tr>
<tr>
<td>Humidity Range</td>
<td colspan="3">40%～95%RH</td>
</tr>
<tr>
<td>Humidity Motion</td>
<td colspan="3">±5% RH</td>
</tr>
<tr>
<td rowspan="11">Structure</td>
<td>Inner Chamber</td>
<td colspan="3">SUS304satinless steel sheet</td>
</tr>
<tr>
<td>Outer Shell</td>
<td colspan="3">Cold rolling steel electrostatic spraying exterior</td>
</tr>
<tr>
<td>Thermal Insulation Material</td>
<td colspan="3">Polyurethane</td>
</tr>
<tr>
<td>Light barrier</td>
<td colspan="3">Standard four layer full spectrum LED lamp board</td>
</tr>
<tr>
<td>Heater</td>
<td colspan="3">Stainless steel heating tube</td>
</tr>
<tr>
<td>Power Rating</td>
<td>2.0kw</td>
<td> 2.2kw</td>
<td>2.5kw</td>
</tr>
<tr>
<td>Compressor</td>
<td colspan="3">Air cooled hermetic compressor</td>
</tr>
<tr>
<td>Coolant</td>
<td colspan="3">R134A</td>
</tr>
<tr>
<td>Defrosting Structure</td>
<td colspan="3">Automatic</td>
</tr>
<tr>
<td>Humidity control mode</td>
<td colspan="3">Automatic</td>
</tr>
<tr>
<td>Leading wire hole</td>
<td colspan="3">The outer diameter of standard inflation port interface is 10mm</td>
</tr>
<tr>
<td rowspan="7">Controller</td>
<td>Temp. control mode</td>
<td colspan="3">30 sections program</td>
</tr>
<tr>
<td>Temp. setting mode</td>
<td colspan="3">Touch screen settings</td>
</tr>
<tr>
<td>Temp. display mode</td>
<td colspan="3">7.0 inch true color touch screen display</td>
</tr>
<tr>
<td>Operation function</td>
<td colspan="3">Fixed tempperature operation,timing function,auto stop. Appointment start, program operaiton</td>
</tr>
<tr>
<td>Program pattern</td>
<td colspan="3">Standard configuration</td>
</tr>
<tr>
<td>Sensor</td>
<td colspan="3">PT100 Temp. Sensor, Imported chip humidity sensor</td>
</tr>
<tr>
<td>Additional funciton</td>
<td colspan="3">Reservation switch,historical tempperature and humidity data curve query, U disk data storage and export,Deviation correction,menu locked,power failure back-up,power failure memory,intelligent defrosting</td>
</tr>
<tr>
<td colspan="2">  Safety device</td>
<td colspan="3">Over tempperature will automatically cut off the heating, long-term under tempperature cut off the refrigeration systemp, protect the sample; loop self diagnosis</td>
</tr>
<tr>
<td rowspan="8">Specification</td>
<td>Inner Chamber size(W*L*H)(mm)</td>
<td>600*500*840</td>
<td>630*580*960</td>
<td>630*670*1100</td>
</tr>
<tr>
<td>Exterior size (W*L*H)(mm)</td>
<td>794*726*1600</td>
<td>824*806*1720</td>
<td>824*896*1860</td>
</tr>
<tr>
<td>Packing size (W*L*H)(mm)</td>
<td>893*863*1850</td>
<td>943*923*1960</td>
<td>823*1033*2110</td>
</tr>
<tr>
<td>Volume</td>
<td>250L</td>
<td>350L</td>
<td>450L</td>
</tr>
<tr>
<td>Load per rack</td>
<td colspan="3">15kg</td>
</tr>
<tr>
<td>Shelf space</td>
<td colspan="3">120mm</td>
</tr>
<tr>
<td>Supply（50/60Hz）Current rating</td>
<td>AC220V/9.1A</td>
<td> AC220V/10A</td>
<td>AC220V/11.5A</td>
</tr>
<tr>
<td>NW/GW (kg）</td>
<td>225/255</td>
<td>260/300</td>
<td>310/350</td>
</tr>
<tr>
<td rowspan="2"> Accessory</td>
<td>Shelf</td>
<td colspan="3">4</td>
</tr>
<tr>
<td>Shelf plate</td>
<td colspan="3">8</td>
</tr>
<tr>
<td colspan="2" rowspan="2"> Optional accessories</td>
<td colspan="3" rowspan="2">Light barrier, USB interface and upper computer software, printer, wireless SMS alarm, CO2 concentration control</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p><a href="https://a2.leadongcdn.com/Climate+Chamber+with+Humidity+Control+Plant+Growth+Chamber+0808-aidjmBpjKjmRijSinqlpklji.pdf" target="_blank" rel="noopener">Climate Chamber with Humidity Control Plant Growth Chamber 0808.pdf</a></p>
<p>&nbsp;</p>
<div class="ast-oembed-container " style="height: 100%;"><iframe title="FPG Plant Growth Chamber/ Climate Chamber / Enviornment Chamber/ FAITHFUL" width="1778" height="1000" src="https://www.youtube.com/embed/un_N5tXoqYk?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
<p>The post <a href="https://keylaser.am/product/climate-chamber-with-humidity-controlplant-growth-chamber/">Climate Chamber with Humidity ControlPlant Growth Chamber</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Climate Chamber With Illumination</title>
		<link>https://keylaser.am/product/climate-chamber-with-illumination/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 26 Sep 2024 15:40:36 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=9209</guid>

					<description><![CDATA[<p>Light culture of microorganism, cell tissue, seedling, insect and small animal</p>
<ul class="pro-itemspecifics-list fix">
<li><label>Model: </label>FLI250, FLI350, FLI450</li>
<li><label>Brand: </label>FAITHFUL</li>
</ul>
<p>The post <a href="https://keylaser.am/product/climate-chamber-with-illumination/">Climate Chamber With Illumination</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>●Double door structure, with high quality stalinite to observe sample.</p>
<p>●7.0 inch true color touch screen display, convenient to view historical temperature data and appointment auto start and stop.</p>
<p>●Full spectrum 0-30000LX adjustable multiple levels, 30 sections programmed Temp. LUX and time controller.</p>
<p>●Full spectrum LED top light source design, high ilumination, low thermal radiation, long service life, removable Light partition, adjustable layer space.</p>
<p>●The evaporator temperature is collectively controlled by the backflow valve and expansion valve, greatly prolonging the service life of the compressor.</p>
<p>●High precision digital independent temperature controller.</p>
<p>●Imported high quality temperature sensor and compressor.</p>
<p>&nbsp;</p>
<table>
<colgroup>
<col />
<col />
<col span="3" /></colgroup>
<tbody>
<tr class="firstRow">
<td colspan="2">Model</td>
<td>FLI250</td>
<td>FLI350</td>
<td>FLI450</td>
</tr>
<tr>
<td colspan="2">Cycle Mode</td>
<td colspan="3">Forced convection,Rear micropore. Supply air in front of the plate</td>
</tr>
<tr>
<td rowspan="5">Function</td>
<td>temp. Range</td>
<td colspan="3">Without illumination: 0～65℃: With illumination:10～65℃</td>
</tr>
<tr>
<td>temp. Resolution Ratio</td>
<td colspan="3">0.1℃</td>
</tr>
<tr>
<td>temp. Motion</td>
<td colspan="3">±1℃</td>
</tr>
<tr>
<td>temp. Uniformity</td>
<td colspan="3">±1.0℃</td>
</tr>
<tr>
<td>illumination(LX)</td>
<td colspan="3">Full spectrum0-30000LX many degrees for adjusting</td>
</tr>
<tr>
<td rowspan="10">Structure</td>
<td>Inner Chamber</td>
<td colspan="3">SUS304satinless steel sheet</td>
</tr>
<tr>
<td>Outer Shell</td>
<td colspan="3">Cold rolling steel electrostatic spraying exterior</td>
</tr>
<tr>
<td>Thermal Insulation Material</td>
<td colspan="3">Polyurethane</td>
</tr>
<tr>
<td>Light barrier</td>
<td colspan="3">Standard four layer full spectrum LED lamp board</td>
</tr>
<tr>
<td>Heater</td>
<td colspan="3">Stainless steel heating tube</td>
</tr>
<tr>
<td>Power Rating</td>
<td>2.0kw</td>
<td> 2.2kw</td>
<td>2.5kw</td>
</tr>
<tr>
<td>Compressor</td>
<td colspan="3">Air cooled hermetic compressor</td>
</tr>
<tr>
<td>Coolant</td>
<td colspan="3">R134A</td>
</tr>
<tr>
<td>Defrosting Structure</td>
<td colspan="3">Automatic</td>
</tr>
<tr>
<td>Leading wire hole</td>
<td colspan="3">The outer diameter of standard inflation port interface is 10mm</td>
</tr>
<tr>
<td rowspan="7">Controller</td>
<td>temp.. control mode</td>
<td colspan="3">30 sections program</td>
</tr>
<tr>
<td>temp.. setting mode</td>
<td colspan="3">Touch screen settings</td>
</tr>
<tr>
<td>temp.. display mode</td>
<td colspan="3">7.0 inch true color touch screen display</td>
</tr>
<tr>
<td>Operation function</td>
<td colspan="3">Fixed temp.perature operation,timing function,auto stop.</td>
</tr>
<tr>
<td>Program pattern</td>
<td colspan="3">Standard configuration</td>
</tr>
<tr>
<td>Sensor</td>
<td colspan="3">Pt100</td>
</tr>
<tr>
<td>Additional funciton</td>
<td colspan="3">Make an appointment to switch on and off, query the historical temp.perature data curve, store and export the U disk data, correct the deviation, lock the menu key, power failure compensation, power failure memory, circuit self diagnosis and intelligent defrosting</td>
</tr>
<tr>
<td colspan="2">  Safety device</td>
<td colspan="3">Over temperature will automatically cut off the heating, long-term under temp.perature cut off the refrigeration systemp., protect the sample; loop self diagnosis</td>
</tr>
<tr>
<td rowspan="8">Specification</td>
<td>Inner Chamber size(W*L*H)(mm)</td>
<td>600*500*840</td>
<td>630*580*960</td>
<td>630*670*1100</td>
</tr>
<tr>
<td>Exterior size (W*L*H)(mm)</td>
<td>794*726*1600</td>
<td>824*806*1720</td>
<td>824*896*1860</td>
</tr>
<tr>
<td>Packing size (W*L*H)(mm)</td>
<td>893*863*1850</td>
<td>943*923*1960</td>
<td>823*1033*2110</td>
</tr>
<tr>
<td>Volume</td>
<td>250L</td>
<td>350L</td>
<td>450L</td>
</tr>
<tr>
<td>Load per rack</td>
<td colspan="3">15kg</td>
</tr>
<tr>
<td>Shelf space</td>
<td colspan="3">120mm</td>
</tr>
<tr>
<td>Supply（50/60Hz）Current rating</td>
<td>AC220V/9.1A</td>
<td> AC220V/10A</td>
<td>AC220V/11.5A</td>
</tr>
<tr>
<td>NW/GW (kg）</td>
<td>220/250</td>
<td>250/290</td>
<td>300/340</td>
</tr>
<tr>
<td rowspan="2">  Accessory</td>
<td>Shelf</td>
<td colspan="3">4</td>
</tr>
<tr>
<td>Shelf plate</td>
<td colspan="3">8</td>
</tr>
<tr>
<td colspan="2" rowspan="2"> Optional accessories</td>
<td colspan="3" rowspan="2">Light barrier, USB interface and upper computer software, wire SMS alarm, co2 concentration control</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<div class="ast-oembed-container " style="height: 100%;"><iframe title="FLI Illumination chamber/ Climate Chmaber/ CE/ FAITHFUL" width="1778" height="1000" src="https://www.youtube.com/embed/HPhagAf3kao?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
<p>The post <a href="https://keylaser.am/product/climate-chamber-with-illumination/">Climate Chamber With Illumination</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Constant Temperature and Humidity Incubators</title>
		<link>https://keylaser.am/product/constant-temperature-and-humidity-incubators/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 26 Sep 2024 15:30:43 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=9203</guid>

					<description><![CDATA[<p>Constant temperature experiment and environmental test of humidity range</p>
<ul class="pro-itemspecifics-list fix">
<li><label>Model: </label>HWS-70B, HWS-150B, HWS-250B</li>
<li><label>Brand: </label>FAITHFUL</li>
</ul>
<p>The post <a href="https://keylaser.am/product/constant-temperature-and-humidity-incubators/">Constant Temperature and Humidity Incubators</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1. Unique internal wind circulation, breeze circulate fan circulation make inner chamber temperature uniformity.</p>
<p>2. Large LCD display,multiple data display at the same time,30-stage program control,round move,ladder operating,with function of loop self-diagnose and sensor fault alarm.</p>
<p>3. Intelligent PID temperature control system, high precise temperature control PT100 sensor equipped, high precise and stability import humidity sensor component to control humidity automaticlly.</p>
<p>4. Double door structure, with high quality stalinite to observe samples, outer door with magnetic strip, convenient to on and off,  good sealing.</p>
<p>5.Intelligent defrosting function ensure device long-time run without defrost. Standard mechanical independent temperature limiter provide double protection.</p>
<p>6.Inner humidifying system with small particles, good humidity uniformity, low water consumption and function of alarm when is short of water.</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<div class="ast-oembed-container " style="height: 100%;"><iframe title="Constant Temperature and Humidity Incubators" width="1778" height="1000" src="https://www.youtube.com/embed/wegBxwT_A8o?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
<p>The post <a href="https://keylaser.am/product/constant-temperature-and-humidity-incubators/">Constant Temperature and Humidity Incubators</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Mould Cultivation Cabinet</title>
		<link>https://keylaser.am/product/mould-cultivation-cabinet/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 26 Sep 2024 15:22:35 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=9198</guid>

					<description><![CDATA[<ul class="pro-itemspecifics-list fix">
<li><label>Model: </label>MJX-70BL, MJX-150BL, MJX-250BL</li>
<li><label>Brand: </label>FAITHFUL</li>
</ul>
<p>The post <a href="https://keylaser.am/product/mould-cultivation-cabinet/">Mould Cultivation Cabinet</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1.Unique internal wind circulation structure design, breeze circulate fan make inner chamber temperature uniformity.</p>
<p>2.LCD display 30-stage program control , round move , ladder operating, intelligent PID temperature control system, high precise temperature control PT100 sensor equipped, high precise and stability import humidity sensor component to control humidity automatically.</p>
<p>3.Double door structure, with high quality stalinite to observe samples，outer door with magnetic strip,convenient to on and off,good sealing.</p>
<p>4.Intelligent defrosting function ensure device long-time run without frost.</p>
<p>5. Inner humidifying system with small particles , good humidity uniformity , low water consumption and function of alarm when is short of water.</p>
<p>&nbsp;</p>
<table width="675">
<colgroup>
<col width="72" />
<col width="146" />
<col width="205" />
<col width="72" />
<col width="72" /></colgroup>
<tbody>
<tr class="firstRow">
<td class="et2" colspan="2" rowspan="1">Model</td>
<td class="et2">MJX-70BL</td>
<td class="et2">MJX-150BL</td>
<td class="et2">MJX-250BL</td>
</tr>
<tr>
<td class="et2" colspan="2">Cycle Mode</td>
<td class="et2" colspan="3">Forced convection</td>
</tr>
<tr>
<td class="et2" rowspan="6">Function</td>
<td class="et2">Temp. range</td>
<td class="et2" colspan="3">No humidification<span class="font0">：</span><span class="font1">0</span><span class="font0">～</span><span class="font1">65</span><span class="font0">℃；</span><span class="font1"><br />
humidification</span><span class="font0">：</span><span class="font1">10 </span><span class="font0">～</span><span class="font1">65</span><span class="font0">℃</span></td>
</tr>
<tr>
<td class="et2">Temp. Resolution<br />
Ratio</td>
<td class="et2" colspan="3">0.1℃</td>
</tr>
<tr>
<td class="et2">Temp. Motion</td>
<td class="et2" colspan="3">High Temp.<span class="font0">：</span><span class="font1">±0.5</span><span class="font0">℃</span><span class="font1"><br />
Low Temp.</span><span class="font0">：</span><span class="font1">±1</span><span class="font0">℃</span></td>
</tr>
<tr>
<td class="et2">Temp. Uniformity</td>
<td class="et2" colspan="3">±1℃</td>
</tr>
<tr>
<td class="et2">Humidity Range</td>
<td class="et2" colspan="3">45%～95%RH</td>
</tr>
<tr>
<td class="et2">Humidity Stability</td>
<td class="et2" colspan="3">±5%RH</td>
</tr>
<tr>
<td class="et2" rowspan="22">Structure</td>
<td class="et2">Inner Chamber</td>
<td class="et2" colspan="3">Mirror Sainless Steel</td>
</tr>
<tr>
<td class="et2">Outer Shell</td>
<td class="et2" colspan="3">Cold rolling steel electrostatic<br />
spraying exterior</td>
</tr>
<tr>
<td class="et2">Insulation layer</td>
<td class="et2" colspan="3">Polyurethane</td>
</tr>
<tr>
<td class="et2">Heater</td>
<td class="et2" colspan="3">Stainless steel heater</td>
</tr>
<tr>
<td class="et2">Power rating</td>
<td class="et2">1.8kW</td>
<td class="et2"> 2.0kW</td>
<td class="et2"> 2.2kW</td>
</tr>
<tr>
<td class="et2">Compressor</td>
<td class="et2" colspan="3">Air cooled hermetic compressor</td>
</tr>
<tr>
<td class="et2">Cryogen</td>
<td class="et2" colspan="3">R134a</td>
</tr>
<tr>
<td class="et2">Defrost structure</td>
<td class="et2" colspan="3">Automatic control intelligent defrosting</td>
</tr>
<tr>
<td class="et2">Humidifying method</td>
<td class="et2" colspan="3">External</td>
</tr>
<tr>
<td class="et2">Test hole</td>
<td class="et2" colspan="3">plastic test hole φ 43mm</td>
</tr>
<tr>
<td class="et2" colspan="1" rowspan="1">      Sterlilzing lamp</td>
<td class="et2" colspan="3" rowspan="1">                Standard ozone-free type</td>
</tr>
<tr>
<td class="et2">Controlled external<br />
power supply</td>
<td class="et2" colspan="3">Universal socket (one)</td>
</tr>
<tr>
<td class="et2" colspan="1" rowspan="1">      Temp. control<br />
mode</td>
<td class="et2" colspan="3" rowspan="1">              30 segment LCD program</td>
</tr>
<tr>
<td class="et2">Temp. setting<br />
mode</td>
<td class="et2" colspan="3">Touch button setting</td>
</tr>
<tr>
<td class="et2">Temp. display<br />
mode</td>
<td class="et2" colspan="3">Measuring temperature: LCD upper row<span class="font0">；</span><span class="font1"><br />
Setting temperature: the lower row </span></td>
</tr>
<tr>
<td class="et2">Humidity control<br />
mode</td>
<td class="et2" colspan="3"><span class="font1">Auto</span></td>
</tr>
<tr>
<td class="et2">Timer</td>
<td class="et2" colspan="3"><span class="font1">0</span><span class="font0">～</span><span class="font1">99.9h×30 Segment<br />
</span><span class="font0">（</span><span class="font1">with timing wait function</span><span class="font0">）</span></td>
</tr>
<tr>
<td class="et2" rowspan="1">Operation Function</td>
<td class="et2" colspan="3">Fixed value operation、timing function,auto stop Program operation</td>
</tr>
<tr>
<td class="et2">Sensor</td>
<td class="et2" colspan="3">PT100</td>
</tr>
<tr>
<td class="et2">Humidity sensor</td>
<td class="et2" colspan="3">High precision anti-condensation</td>
</tr>
<tr>
<td class="et2" rowspan="2">Additional funciton</td>
<td class="et2" colspan="3"><span class="font1">Deviation correction,<br />
Menu key lock, Power failure parameter memory</span></td>
</tr>
<tr>
<td class="et2" colspan="3"> additional character<span class="font0">：</span><span class="font1"><br />
UV light, loop self diagnosis</span></td>
</tr>
<tr>
<td class="et2" colspan="2">Safety device</td>
<td class="et2" colspan="3">Over humidity alarm, water shortage alarm</p>
<p>Over temperature alarm</td>
</tr>
<tr>
<td class="et2" rowspan="9">Specification</td>
<td class="et2">Inner Chamber size<br />
(W*L*H)<br />
(mm)</td>
<td class="et2">415*350<br />
*500</td>
<td class="et2">490*400<br />
*750</td>
<td class="et2">500*500<br />
*950</td>
</tr>
<tr>
<td class="et2">Exterior size<br />
(W*L*H)<br />
(mm)</td>
<td class="et2">571*591<br />
*1051</td>
<td class="et2">646*641<br />
*1301</td>
<td class="et2">656*741<br />
*1501</td>
</tr>
<tr>
<td class="et2">Packing size (W*L*H)(mm)</td>
<td class="et2">680*676<br />
*1235</td>
<td class="et2">751*730<br />
*1490</td>
<td class="et2">761*830<br />
*1690</td>
</tr>
<tr>
<td class="et2">Volume</td>
<td class="et2">70L</td>
<td class="et2">150L</td>
<td class="et2">250L</td>
</tr>
<tr>
<td class="et2">Load per rack</td>
<td class="et2" colspan="3">15kg</td>
</tr>
<tr>
<td class="et2">Shelf number</td>
<td class="et2">5</td>
<td class="et2">9</td>
<td class="et2">12</td>
</tr>
<tr>
<td class="et2">Shelf space</td>
<td class="et2" colspan="3">35mm</td>
</tr>
<tr>
<td class="et2">Supply<br />
<span class="font0">（</span><span class="font1">50/60Hz</span><span class="font0">）</span><span class="font1">Current rating</span></td>
<td class="et2">AC220V/<br />
8.2A</td>
<td class="et2">AC220V/<br />
9.1A</td>
<td class="et2">AC220V/<br />
10A</td>
</tr>
<tr>
<td class="et2">NW/GW (kg）</td>
<td class="et2">69/92</td>
<td class="et2">86/114</td>
<td class="et2">100/139</td>
</tr>
<tr>
<td class="et2" colspan="1" rowspan="2" width="NaN"> Accessory</td>
<td class="et2">Shelf</td>
<td class="et2" colspan="3">2</td>
</tr>
<tr>
<td class="et2" colspan="1" rowspan="1">            Shelf rack</td>
<td class="et2" colspan="3" rowspan="1" width="NaN">                                  4</td>
</tr>
<tr>
<td class="et2" colspan="2" rowspan="2">optional accessories</td>
<td class="et2" colspan="3" rowspan="2">Spare shelf, RS485 interface USB interface and software,<br />
Printer, Recorder, Remote control, Wireless<br />
U-disk storage</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<div class="ast-oembed-container " style="height: 100%;"><iframe loading="lazy" title="Mould Cultivation Cabinet / MJX Incubator/ CE" width="1778" height="1000" src="https://www.youtube.com/embed/gpc0bjf0U_Q?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
<p>The post <a href="https://keylaser.am/product/mould-cultivation-cabinet/">Mould Cultivation Cabinet</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Cooling Incubator(Refrigerated Incubator/BOD Incubator)</title>
		<link>https://keylaser.am/product/cooling-incubatorrefrigerated-incubator-bod-incubator/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 25 Sep 2024 19:17:21 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=9192</guid>

					<description><![CDATA[<ul class="pro-itemspecifics-list fix">
<li><label>Model: </label>SPX-70BIII, SPX-150BIII, SPX-250BIII, SPX-70BX, SPX-150BX, SPX-250BX</li>
<li><label>Brand: </label>FAITHFUL</li>
</ul>
<p>The post <a href="https://keylaser.am/product/cooling-incubatorrefrigerated-incubator-bod-incubator/">Cooling Incubator(Refrigerated Incubator/BOD Incubator)</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1. Unique internal wind circulation structure design, breeze circulate fan make inner chamber temperature uniformity.</p>
<p>2. Double door seal; tempered glass silicon subber seal inner door and magnetic rubber seal outer door, which are convenient to on/off; inner chamber with light for convenient observation.</p>
<p>3.Intelligent defrosting function ensure device long-time run without frost. Fluoride-free refrigeration and gentle breeze circulation.</p>
<p>4.Test hole of  52mm at left side of container.</p>
<p>BX model additional characteristics:</p>
<p>1.LCD scree 30-stage program controller,round move,ladder operating.</p>
<p>2.Sensor failure alarm</p>
<p>&nbsp;</p>
<table width="745">
<tbody>
<tr class="firstRow">
<td colspan="2" rowspan="2" align="center" valign="middle" width="298">Model</td>
<td align="center" valign="middle" width="149">SPX-70BIII</td>
<td align="center" valign="middle" width="149">SPX-150BIII</td>
<td align="center" valign="middle" width="149">SPX-250BIII</td>
</tr>
<tr>
<td align="center" valign="middle" width="149">SPX-70BX</td>
<td align="center" valign="middle" width="149">SPX-150BX</td>
<td align="center" valign="middle" width="149">SPX-250BX</td>
</tr>
<tr>
<td colspan="2" align="center" valign="middle" width="298">Cycle Mode</td>
<td colspan="3" align="center" valign="middle" width="447">Forced convection</td>
</tr>
<tr>
<td rowspan="4" align="center" valign="middle" width="149">Function</td>
<td align="left" valign="middle" width="149">Temp. range</td>
<td colspan="3" align="center" valign="middle" width="447">0～65℃</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Temp. Resolution Ratio</td>
<td colspan="3" align="center" valign="middle" width="447">0.1℃</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Temp. Motion</td>
<td colspan="3" align="center" valign="middle" width="447">High Temp.：±0.5℃      Low Temp.：±1℃</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Temp. Uniformity</td>
<td colspan="3" align="center" valign="middle" width="447">±1.5℃</td>
</tr>
<tr>
<td rowspan="18" align="center" valign="middle" width="149">Structure</td>
<td align="left" valign="middle" width="149">Inner Chamber</td>
<td colspan="3" align="center" valign="middle" width="447">Mirror Stainless Steel</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Outer Shell</td>
<td colspan="3" align="center" valign="middle" width="447">Cold rolling steel electrostatic spraying exterior</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Insulation layer</td>
<td colspan="3" align="center" valign="middle" width="447">Polyurethane</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Heater</td>
<td colspan="3" align="center" valign="middle" width="447">Stainless steel heater</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Power rating</td>
<td align="center" valign="middle" width="149">0.8kW</td>
<td align="center" valign="middle" width="149">1.0kW</td>
<td align="center" valign="middle" width="149">1.2kW</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Compressor</td>
<td colspan="3" align="center" valign="middle" width="447">Air cooled hermetic compressor</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Cryogen</td>
<td colspan="3" align="center" valign="middle" width="447">R134a</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Defrost structure</td>
<td colspan="3" align="center" valign="middle" width="447">Automatic control intelligent defrosting</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Test hole</td>
<td colspan="3" align="center" valign="middle" width="447">Inner diameter 43mm(one)</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Controlled external power supply</td>
<td colspan="3" align="center" valign="middle" width="447">Outer universal socket (one), inner waterproof socket(one)</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Temp. setting mode</td>
<td colspan="3" align="center" valign="middle" width="447">Touch button setting</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Temp. display mode</td>
<td colspan="3" align="center" valign="middle" width="447">Measuring temperature: LCD upper screen; setting temperature: the lower row</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Timer</td>
<td colspan="3" align="center" valign="middle" width="447">BIII model：0～99.9h    BX model：0～99.9h×10 segment(with timing wait function)</td>
</tr>
<tr>
<td rowspan="2" align="left" valign="middle" width="149">Operation function</td>
<td colspan="3" align="center" valign="middle" width="447">BIII model：Fixed value operation、timing function,auto stop.</td>
</tr>
<tr>
<td colspan="3" align="center" valign="middle" width="447">BX model：Program operation</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Sensor</td>
<td colspan="3" align="center" valign="middle" width="447">PT100</td>
</tr>
<tr>
<td rowspan="2" align="left" valign="middle" width="149">Additional funciton</td>
<td colspan="3" align="center" valign="middle" width="447">BIII model：LED light, Deviation correction, Menu key lock, Power failure parameter memory</td>
</tr>
<tr>
<td colspan="3" align="center" valign="middle" width="447">BX model :Loop self diagnosis, sensor fault alarm</td>
</tr>
<tr>
<td colspan="2" align="center" valign="middle" width="298">Safety device</td>
<td colspan="3" align="center" valign="middle" width="447">Over temperature alarm,</td>
</tr>
<tr>
<td rowspan="9" align="center" valign="middle" width="149">Specification</td>
<td align="left" valign="middle" width="149">Inner Chamber size(W*L*H)(mm)</td>
<td align="center" valign="middle" width="149">415*350*500</td>
<td align="center" valign="middle" width="149">490*400*750</td>
<td align="center" valign="middle" width="149">500*500*950</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Exterior size (W*L*H)(mm)</td>
<td align="center" valign="middle" width="149">571*591*1051</td>
<td align="center" valign="middle" width="149">646*641*1301</td>
<td align="center" valign="middle" width="149">656*741*1501</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Packing size (W*L*H)(mm)</td>
<td align="center" valign="middle" width="149">680*676*1235</td>
<td align="center" valign="middle" width="149">751*730*1490</td>
<td align="center" valign="middle" width="149">761*830*1690</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Volume</td>
<td align="center" valign="middle" width="149">70L</td>
<td align="center" valign="middle" width="149">150L</td>
<td align="center" valign="middle" width="149">250L</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Load per rack</td>
<td colspan="3" align="center" valign="middle" width="447">15kg</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Shelf number</td>
<td align="center" valign="middle" width="149">5</td>
<td align="center" valign="middle" width="149">9</td>
<td align="center" valign="middle" width="149">12</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Shelf space</td>
<td colspan="3" align="center" valign="middle" width="447">60mm</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Power Supply Current rating</td>
<td align="center" valign="middle" width="149">AC220V/2.3A</td>
<td align="center" valign="middle" width="149">AC220V/3.6A</td>
<td align="center" valign="middle" width="149">AC220V/5.5A</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">NW/GW (kg）</td>
<td align="center" valign="middle" width="149">69/92</td>
<td align="center" valign="middle" width="149">86/114</td>
<td align="center" valign="middle" width="149">100/139</td>
</tr>
<tr>
<td rowspan="2" align="center" valign="middle" width="149">Accessory</td>
<td align="left" valign="middle" width="149">Shelf</td>
<td colspan="3" align="center" valign="middle" width="447">2</td>
</tr>
<tr>
<td align="left" valign="middle" width="149">Shelf Frame</td>
<td colspan="3" align="center" valign="middle" width="447">4</td>
</tr>
<tr>
<td colspan="2" rowspan="2" align="center" valign="middle" width="298">optional accessories</td>
<td colspan="3" rowspan="2" align="center" valign="middle" width="447">Shelf, RS485 port, Printer, Recorder, Remote control, wireless messaging alarm, U-Disk data storage</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>The post <a href="https://keylaser.am/product/cooling-incubatorrefrigerated-incubator-bod-incubator/">Cooling Incubator(Refrigerated Incubator/BOD Incubator)</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Precision cooling  Incubator /Refrigerated Incubator/BOD Incubator</title>
		<link>https://keylaser.am/product/precision-cooling-incubator-refrigerated-incubator-bod-incubator/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 25 Sep 2024 19:12:31 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=9185</guid>

					<description><![CDATA[<ul class="pro-itemspecifics-list fix">
<li><label>Model: </label>SPX-70BIV, SPX-150BIV, SPX-250BIV,SPX-70BL, SPX-150BL, SPX-250BL</li>
<li><label>Brand: </label>FAITHFUL</li>
</ul>
<p>The post <a href="https://keylaser.am/product/precision-cooling-incubator-refrigerated-incubator-bod-incubator/">Precision cooling  Incubator /Refrigerated Incubator/BOD Incubator</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1.Unique internal wind circulation structure design, fan breeze circulation.</p>
<p>2. The double door structure, with high quality glass easy to observe the samples, the outer door with magnetic strip, good sealing.</p>
<p>3. Colour LCD display  and 30-stage program temperature control, double evaporators and automatic control intelligent defrosting to ensure long-term operating without defrost. Standard independent temperature limiter, double protection for test safety.</p>
<p>BL model additional characteristics：</p>
<p>1.5.0 inch touch display 30-stage program control, round move, ladder operating.</p>
<p>2.Sensor failure alarm.</p>
<p>3.UV Lamp</p>
<p>&nbsp;</p>
<table width="745">
<colgroup>
<col width="149" />
<col width="149" />
<col span="3" width="149" /></colgroup>
<tbody>
<tr class="firstRow">
<td colspan="2" rowspan="2" align="center" valign="middle" width="298">Model</td>
<td align="center" valign="middle" width="149">SPX-70BIV</td>
<td align="center" valign="middle" width="149">SPX-150BIV</td>
<td align="center" valign="middle" width="149">SPX-250BIV</td>
</tr>
<tr>
<td align="center" valign="middle" width="149">SPX-70BL</td>
<td align="center" valign="middle" width="149">SPX-150BL</td>
<td align="center" valign="middle" width="149">SPX-250BL</td>
</tr>
<tr>
<td colspan="2" align="center" valign="middle" width="298">Cycle Mode</td>
<td colspan="3" align="center" valign="middle" width="447">Forced convection</td>
</tr>
<tr>
<td rowspan="4" align="center" valign="middle" width="149">Function</td>
<td width="149">Temp. range</td>
<td colspan="3" align="center" valign="middle" width="447">0～65℃</td>
</tr>
<tr>
<td width="149">Temp. Resolution Ratio</td>
<td colspan="3" align="center" valign="middle" width="447">0.1℃</td>
</tr>
<tr>
<td width="149">Temp. Motion</td>
<td colspan="3" align="center" valign="middle" width="447">High Temp.：±0.5℃      Low Temp.：±1℃</td>
</tr>
<tr>
<td width="149">Temp. Uniformity</td>
<td colspan="3" align="center" valign="middle" width="447">±1℃</td>
</tr>
<tr>
<td rowspan="18" align="center" valign="middle" width="149">Structure</td>
<td width="149">Inner Chamber</td>
<td colspan="3" align="center" valign="middle" width="447">Mirror Stainless Steel</td>
</tr>
<tr>
<td width="149">Outer Shell</td>
<td colspan="3" align="center" valign="middle" width="447">Cold rolling steel electrostatic spraying exterior</td>
</tr>
<tr>
<td width="149">Insulation layer</td>
<td colspan="3" align="center" valign="middle" width="447">Polyurethane</td>
</tr>
<tr>
<td width="149">Heater</td>
<td colspan="3" align="center" valign="middle" width="447">Stainless steel heating tube</td>
</tr>
<tr>
<td width="149">Power rating</td>
<td align="center" valign="middle" width="149">0.8kW</td>
<td align="center" valign="middle" width="149">1.0kW</td>
<td align="center" valign="middle" width="149"> 1.2kW</td>
</tr>
<tr>
<td width="149">Compressor</td>
<td colspan="3" align="center" valign="middle" width="447">Air cooled hermetic compressor</td>
</tr>
<tr>
<td width="149">Cryogen</td>
<td colspan="3" align="center" valign="middle" width="447">R134a</td>
</tr>
<tr>
<td width="149">Defrost structure</td>
<td colspan="3" align="center" valign="middle" width="447">Double evaporator switching defrosting</td>
</tr>
<tr>
<td width="149">Test hole</td>
<td colspan="3" align="center" valign="middle" width="447">43mm</td>
</tr>
<tr>
<td width="149">Controlled external power supply</td>
<td colspan="3" align="center" valign="middle" width="447">Universal socket (one) Built in waterproof socked (one)</td>
</tr>
<tr>
<td width="149">Temp.Control mode</td>
<td colspan="3" align="center" valign="middle" width="447">BIV:Color screen LCD program  BL:5.0 inch touch screen</td>
</tr>
<tr>
<td width="149">Temp. setting mode</td>
<td colspan="3" align="center" valign="middle" width="447">Touch button setting or Touch screen type</td>
</tr>
<tr>
<td width="149">Temp. display mode</td>
<td colspan="3" align="center" valign="middle" width="447">Measuring temperature: LCD upper screen; setting temperature: the lower row</td>
</tr>
<tr>
<td width="149">Timer</td>
<td colspan="3" align="center" valign="middle" width="447">0～99.9h×30 Segment</td>
</tr>
<tr>
<td width="149">Operation function</td>
<td colspan="3" align="center" valign="middle" width="447">Program operation</td>
</tr>
<tr>
<td width="149">Sensor</td>
<td colspan="3" align="center" valign="middle" width="447">PT100</td>
</tr>
<tr>
<td rowspan="2" width="149">Additional funciton</td>
<td colspan="3" align="center" valign="middle" width="447">BIV model：LED light, Deviation correction, Menu key lock, Power failure parameter memory</td>
</tr>
<tr>
<td colspan="3" align="center" valign="middle" width="447">BL model additional character： loop self diagnosis</td>
</tr>
<tr>
<td colspan="2" align="center" valign="middle" width="298"> Safety device</td>
<td colspan="3" align="center" valign="middle" width="447">Over temperature alarm, digital  temperature limiter</td>
</tr>
<tr>
<td rowspan="9" align="center" valign="middle" width="149">Specification</td>
<td width="149">Inner Chamber size(W*L*H)(mm)</td>
<td align="center" valign="middle" width="149">420*350*500</td>
<td align="center" valign="middle" width="149">500*500*600</td>
<td align="center" valign="middle" width="149">600*500*840</td>
</tr>
<tr>
<td width="149">Exterior size (W*L*H)(mm)</td>
<td align="center" valign="middle" width="149">580*610*1190</td>
<td align="center" valign="middle" width="149">660*760*1290</td>
<td align="center" valign="middle" width="149">760*760*1530</td>
</tr>
<tr>
<td width="149">Packing size (W*L*H)(mm)</td>
<td align="center" valign="middle" width="149">706*698*1358</td>
<td align="center" valign="middle" width="149">856*778*1458</td>
<td align="center" valign="middle" width="149">878*865*1698</td>
</tr>
<tr>
<td width="149">Volume</td>
<td align="center" valign="middle" width="149">70L</td>
<td align="center" valign="middle" width="149">150L</td>
<td align="center" valign="middle" width="149">250L</td>
</tr>
<tr>
<td width="149">Load per rack</td>
<td colspan="3" align="center" valign="middle" width="447">15kg</td>
</tr>
<tr>
<td width="149">Shelf number</td>
<td align="center" valign="middle" width="149">9</td>
<td align="center" valign="middle" width="149">12</td>
<td align="center" valign="middle" width="149">18</td>
</tr>
<tr>
<td width="149">Shelf space</td>
<td colspan="3" align="center" valign="middle" width="447">35mm</td>
</tr>
<tr>
<td width="149">Power Supply Current rating</td>
<td align="center" valign="middle" width="149">AC220V/2.3A</td>
<td align="center" valign="middle" width="149">AC220V/3.6A</td>
<td align="center" valign="middle" width="149">AC220V/5.5A</td>
</tr>
<tr>
<td width="149">NW/GW (kg）</td>
<td align="center" valign="middle" width="149">69/92</td>
<td align="center" valign="middle" width="149">86/114</td>
<td align="center" valign="middle" width="149">100/139</td>
</tr>
<tr>
<td colspan="2" align="center" valign="middle" width="298">Shelf</td>
<td colspan="3" align="center" valign="middle" width="447">2</td>
</tr>
<tr>
<td colspan="2" rowspan="2" align="center" valign="middle" width="298">optional accessories</td>
<td colspan="3" rowspan="2" align="center" valign="middle" width="447">Spare Shelf, RS485 interface, Printer, Program controller, Remote control, U-disk storage</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>The post <a href="https://keylaser.am/product/precision-cooling-incubator-refrigerated-incubator-bod-incubator/">Precision cooling  Incubator /Refrigerated Incubator/BOD Incubator</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>-10°C cooling  Incubator /BOD Incubator/Refrigerated Incubator</title>
		<link>https://keylaser.am/product/10c-cooling-incubator-bod-incubator-refrigerated-incubator/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 25 Sep 2024 19:05:45 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=9180</guid>

					<description><![CDATA[<ul class="pro-itemspecifics-list fix">
<li><label>Model: </label>SPX-70BV, SPX-150BV, SPX-250BV,SPX-70BLT, SPX-150BLT, SPX-250BLT</li>
<li><label>Brand: </label>FAITHFUL</li>
</ul>
<p>The post <a href="https://keylaser.am/product/10c-cooling-incubator-bod-incubator-refrigerated-incubator/">-10°C cooling  Incubator /BOD Incubator/Refrigerated Incubator</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1.Unique internal wind circulation structure design, fan breeze circulation.</p>
<p>2. The double door structure, with high quality glass easy to observe the samples, the outer door with magnetic strip, good sealing.</p>
<p>3. Colour LCD display  and 30-stage program temperature control, double evaporators and automatic control intelligent defrosting to ensure long-term operating without defrost. Standard independent temperature limiter, double protection for test safety.</p>
<p>BLTmodel additional characteristics：</p>
<p>1.5.0 inch touch display 30-stage program control, round move, ladder operating.</p>
<p>2.Sensor failure alarm.</p>
<p>3.UV Lamp</p>
<p>&nbsp;</p>
<table width="745">
<colgroup>
<col width="149" />
<col width="149" />
<col span="3" width="149" /></colgroup>
<tbody>
<tr class="firstRow">
<td colspan="2" rowspan="2" align="center" valign="middle" width="298">Model</td>
<td align="center" valign="middle" width="149">SPX-70BV</td>
<td align="center" valign="middle" width="149">SPX-150BV</td>
<td align="center" valign="middle" width="149">SPX-250BV</td>
</tr>
<tr>
<td align="center" valign="middle" width="149">SPX-70BLT</td>
<td align="center" valign="middle" width="149">SPX-150BLT</td>
<td align="center" valign="middle" width="149">SPX-250BLT</td>
</tr>
<tr>
<td colspan="2" align="center" valign="middle" width="298">Cycle Mode</td>
<td colspan="3" align="center" valign="middle" width="447">Forced convection</td>
</tr>
<tr>
<td rowspan="4" align="center" valign="middle" width="149">Function</td>
<td width="149">Temp. range</td>
<td colspan="3" align="center" valign="middle" width="447">-10～65℃</td>
</tr>
<tr>
<td width="149">Temp. Resolution Ratio</td>
<td colspan="3" align="center" valign="middle" width="447">0.1℃</td>
</tr>
<tr>
<td width="149">Temp. Motion</td>
<td colspan="3" align="center" valign="middle" width="447">High Temp.：±0.5℃      Low Temp.：±1℃</td>
</tr>
<tr>
<td width="149">Temp. Uniformity</td>
<td colspan="3" align="center" valign="middle" width="447">±1℃</td>
</tr>
<tr>
<td rowspan="18" align="center" valign="middle" width="149">Structure</td>
<td width="149">Inner Chamber</td>
<td colspan="3" align="center" valign="middle" width="447">Mirror Stainless Steel</td>
</tr>
<tr>
<td width="149">Outer Shell</td>
<td colspan="3" align="center" valign="middle" width="447">Cold rolling steel electrostatic spraying exterior</td>
</tr>
<tr>
<td width="149">Insulation layer</td>
<td colspan="3" align="center" valign="middle" width="447">Polyurethane</td>
</tr>
<tr>
<td width="149">Heater</td>
<td colspan="3" align="center" valign="middle" width="447">Stainless steel heating tube</td>
</tr>
<tr>
<td width="149">Power rating</td>
<td align="center" valign="middle" width="149">0.8kW</td>
<td align="center" valign="middle" width="149">1.0kW</td>
<td align="center" valign="middle" width="149"> 1.2kW</td>
</tr>
<tr>
<td width="149">Compressor</td>
<td colspan="3" align="center" valign="middle" width="447">Air cooled hermetic compressor</td>
</tr>
<tr>
<td width="149">Cryogen</td>
<td colspan="3" align="center" valign="middle" width="447">R134a</td>
</tr>
<tr>
<td width="149">Defrost structure</td>
<td colspan="3" align="center" valign="middle" width="447">Double evaporator switching defrosting</td>
</tr>
<tr>
<td width="149">Test hole</td>
<td colspan="3" align="center" valign="middle" width="447">43mm</td>
</tr>
<tr>
<td width="149">Controlled external power supply</td>
<td colspan="3" align="center" valign="middle" width="447">Universal socket (one) Built in waterproof socked (one)</td>
</tr>
<tr>
<td width="149">Temp.Control mode</td>
<td colspan="3" align="center" valign="middle" width="447">BIV:Color screen LCD program  BL:5.0 inch touch screen</td>
</tr>
<tr>
<td width="149">Temp. setting mode</td>
<td colspan="3" align="center" valign="middle" width="447">Touch button setting or Touch screen type</td>
</tr>
<tr>
<td width="149">Temp. display mode</td>
<td colspan="3" align="center" valign="middle" width="447">Measuring temperature: LCD upper screen; setting temperature: the lower row</td>
</tr>
<tr>
<td width="149">Timer</td>
<td colspan="3" align="center" valign="middle" width="447">0～99.9h×30 Segment</td>
</tr>
<tr>
<td width="149">Operation function</td>
<td colspan="3" align="center" valign="middle" width="447">Program operation</td>
</tr>
<tr>
<td width="149">Sensor</td>
<td colspan="3" align="center" valign="middle" width="447">PT100</td>
</tr>
<tr>
<td rowspan="2" width="149">Additional funciton</td>
<td colspan="3" align="center" valign="middle" width="447">BIV model：LED light, Deviation correction, Menu key lock, Power failure parameter memory</td>
</tr>
<tr>
<td colspan="3" align="center" valign="middle" width="447">BL model additional character： loop self diagnosis</td>
</tr>
<tr>
<td colspan="2" align="center" valign="middle" width="298"> Safety device</td>
<td colspan="3" align="center" valign="middle" width="447">Over temperature alarm, digital  temperature limiter</td>
</tr>
<tr>
<td rowspan="9" align="center" valign="middle" width="149">Specification</td>
<td width="149">Inner Chamber size(W*L*H)(mm)</td>
<td align="center" valign="middle" width="149">420*350*500</td>
<td align="center" valign="middle" width="149">500*500*600</td>
<td align="center" valign="middle" width="149">600*500*840</td>
</tr>
<tr>
<td width="149">Exterior size (W*L*H)(mm)</td>
<td align="center" valign="middle" width="149">580*610*1190</td>
<td align="center" valign="middle" width="149">660*760*1290</td>
<td align="center" valign="middle" width="149">760*760*1530</td>
</tr>
<tr>
<td width="149">Packing size (W*L*H)(mm)</td>
<td align="center" valign="middle" width="149">706*698*1358</td>
<td align="center" valign="middle" width="149">856*778*1458</td>
<td align="center" valign="middle" width="149">878*865*1698</td>
</tr>
<tr>
<td width="149">Volume</td>
<td align="center" valign="middle" width="149">70L</td>
<td align="center" valign="middle" width="149">150L</td>
<td align="center" valign="middle" width="149">250L</td>
</tr>
<tr>
<td width="149">Load per rack</td>
<td colspan="3" align="center" valign="middle" width="447">15kg</td>
</tr>
<tr>
<td width="149">Shelf number</td>
<td align="center" valign="middle" width="149">9</td>
<td align="center" valign="middle" width="149">12</td>
<td align="center" valign="middle" width="149">18</td>
</tr>
<tr>
<td width="149">Shelf space</td>
<td colspan="3" align="center" valign="middle" width="447">35mm</td>
</tr>
<tr>
<td width="149">Power Supply Current rating</td>
<td align="center" valign="middle" width="149">AC220V/2.3A</td>
<td align="center" valign="middle" width="149">AC220V/3.6A</td>
<td align="center" valign="middle" width="149">AC220V/5.5A</td>
</tr>
<tr>
<td width="149">NW/GW (kg）</td>
<td align="center" valign="middle" width="149">69/92</td>
<td align="center" valign="middle" width="149">86/114</td>
<td align="center" valign="middle" width="149">100/139</td>
</tr>
<tr>
<td colspan="2" align="center" valign="middle" width="298">Shelf</td>
<td colspan="3" align="center" valign="middle" width="447">2</td>
</tr>
<tr>
<td colspan="2" rowspan="2" align="center" valign="middle" width="298">optional accessories</td>
<td colspan="3" rowspan="2" align="center" valign="middle" width="447">Spare Shelf, RS485 interface, Printer, Program controller, Remote control, U-disk storage</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p><a href="https://a0.leadongcdn.com/-10%C2%B0C+cooling+%C2%A0Incubator+BOD+IncubatorRefrigerated%C2%A0Incubator-aidjqBpjKjmRijSpplmnjljj.pdf?dp=GvUApKfKKUAU">Catalogue</a></p>
<p>&nbsp;</p>
<p>The post <a href="https://keylaser.am/product/10c-cooling-incubator-bod-incubator-refrigerated-incubator/">-10°C cooling  Incubator /BOD Incubator/Refrigerated Incubator</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Portable Incubator</title>
		<link>https://keylaser.am/product/portable-incubator/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 25 Sep 2024 18:51:59 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=9172</guid>

					<description><![CDATA[<ul class="pro-itemspecifics-list fix">
<li><label>Model: </label>DH2500AB ,DH3000AB</li>
<li><label>Brand: </label>FAITHFUL</li>
</ul>
<p>The post <a href="https://keylaser.am/product/portable-incubator/">Portable Incubator</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1. Internal naturally air convection,four sides heating method, to make inner temperature uniformity.</p>
<p>2. Mirror stainless steel inner chamber, four corners arc transition easy to clean.</p>
<p>3. PID controller, with over-temperature protection function, with over-temperature alarm, sensor fault alarm,fixed value operation, regular operation, deviation correction ,menu locking and other functions.</p>
<p>4. With high quality glass window and installed LED light on the door, easy to observe the sample inside, especially under dark conditions.</p>
<p>5. Portable design, the top handle is easy to move,optional 12V vehicle power supply, vehicle 12V, 100-240V can be used.</p>
<p>&nbsp;</p>
<div class="detial-cont-tabscont">
<div class="fix prodDesc hide">
<div class="prodDetail-editor-container">
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="883">
<colgroup>
<col />
<col />
<col span="2" /></colgroup>
<tbody>
<tr class="firstRow">
<td colspan="2">Model</td>
<td>DH2500AB</td>
<td>DH3000AB</td>
</tr>
<tr>
<td colspan="2">Cycle Mode</td>
<td colspan="2">Natural convection</td>
</tr>
<tr>
<td rowspan="4">Function</td>
<td>Tem. Range</td>
<td colspan="2">RT+5-65℃</td>
</tr>
<tr>
<td>Tem. Resolution Ratio</td>
<td colspan="2">0.1℃</td>
</tr>
<tr>
<td>Tem. Motion</td>
<td colspan="2">±0.5℃</td>
</tr>
<tr>
<td>Tem. Uniformity</td>
<td colspan="2">±1.5℃</td>
</tr>
<tr>
<td rowspan="5">Structure</td>
<td>Inner Chamber</td>
<td colspan="2">Mirror stainless steel</td>
</tr>
<tr>
<td>Outer Shell</td>
<td colspan="2">Cold rolling steel electrostatic spraying exterior</td>
</tr>
<tr>
<td>Insulation layer</td>
<td colspan="2">Polyurethane</td>
</tr>
<tr>
<td>Heater</td>
<td colspan="2">Heating Wire</td>
</tr>
<tr>
<td>Power Rating</td>
<td>0.08kW</td>
<td>0.12kW</td>
</tr>
<tr>
<td rowspan="7">Controller</td>
<td>Tem. control mode</td>
<td colspan="2">PID Intelligent</td>
</tr>
<tr>
<td>Tem. setting mode</td>
<td colspan="2">Touch button setting</td>
</tr>
<tr>
<td>Tem. display mode</td>
<td colspan="2">Measuring temperature: LED upper row;Setting temperature: the lower row</td>
</tr>
<tr>
<td>Timer</td>
<td colspan="2">0-9999min (with timing wait function)</td>
</tr>
<tr>
<td>Operation function</td>
<td colspan="2">Fixed temperature operation, timing function,auto stop.</td>
</tr>
<tr>
<td>Additional funciton</td>
<td colspan="2">Sensor deviation correction, temperature overshoot self-tuning, internal parameter locking, power-off parameter memory</td>
</tr>
<tr>
<td>Sensor</td>
<td colspan="2">PT100</td>
</tr>
<tr>
<td colspan="2">Safety device</td>
<td colspan="2">Over temperature sound-light alarm</td>
</tr>
<tr>
<td rowspan="9">Specification</td>
<td>Inner Chamber size(W*L*H)(mm)</td>
<td>230*200*200</td>
<td>230*200*280</td>
</tr>
<tr>
<td>Exterior size (W*L*H)(mm)</td>
<td>310*276*298</td>
<td>310*276*378</td>
</tr>
<tr>
<td>Packing size (W*L*H)(mm)</td>
<td>350*312*377</td>
<td>350*312*457</td>
</tr>
<tr>
<td>Volume</td>
<td>9.2L</td>
<td>12.8L</td>
</tr>
<tr>
<td>Shelf Number</td>
<td colspan="2">2</td>
</tr>
<tr>
<td>Load Per Rack</td>
<td colspan="2">5kg</td>
</tr>
<tr>
<td>Shelf Space</td>
<td colspan="2">35mm</td>
</tr>
<tr>
<td>Supply(50/60HZ)<br />
Current rating</td>
<td>AC220V/0.36A</td>
<td>AC220V/0.36A</td>
</tr>
<tr>
<td>NW/GW (kg）</td>
<td>8/10</td>
<td>12/14</td>
</tr>
<tr>
<td colspan="2">Optional Accessories</td>
<td colspan="2">Vehicular/DC12V/AC110V/AC220VSupply</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
</div>
<div class="ast-oembed-container " style="height: 100%;"><iframe loading="lazy" title="Portable Incubator/ Vehicle incubator/DH2500AB DH3000AB" width="1778" height="1000" src="https://www.youtube.com/embed/cB5bptmKQg4?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/portable-incubator/">Portable Incubator</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Constant-temperature Incubator</title>
		<link>https://keylaser.am/product/constant-temperature-incubator/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 25 Sep 2024 18:42:54 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=9167</guid>

					<description><![CDATA[<ul class="pro-itemspecifics-list fix">
<li><label>Model: </label>WPL-30BE,WPL-45BE, WPL-65BE, WPL-85BE, WPL-125BE, WPL-230BE,WPL-30BE(304), WPL-45BE(304), WPL-65BE(304), WPL-85BE(304), WPL-125BE(304)</li>
<li><label>Brand: </label>FAITHFUL</li>
</ul>
<p>The post <a href="https://keylaser.am/product/constant-temperature-incubator/">Constant-temperature Incubator</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1. Unique vertical double duct supply horizontal air circularly.</p>
<p>2. 4 grades 3 speed adjustable speed fan, LED running indicator light.</p>
<p>3. Over-temperature protection system: LED red light on meanwhile cut off heating circuit to improve product safety when workroom temperature exceed the alarm value.</p>
<p>4. High precision digital independent temperature limiter.</p>
<p>5. 304:SUS304 Stainless Steel Body.</p>
<table width="868">
<colgroup>
<col width="72" />
<col width="72" />
<col width="72" />
<col width="72" />
<col width="72" />
<col width="72" />
<col width="72" />
<col width="72" /></colgroup>
<tbody>
<tr class="firstRow">
<td class="et2" colspan="2" rowspan="2">Model</td>
<td class="et2" width="93">WPL-<br />
30BE</td>
<td class="et2" width="93">WPL-<br />
45BE</td>
<td class="et2" width="93">WPL-<br />
65BE</td>
<td class="et2" width="82">WPL-<br />
85BE</td>
<td class="et2" width="82">WPL-<br />
125BE</td>
<td class="et2" width="92">WPL-<br />
230BE</td>
</tr>
<tr>
<td class="et2" colspan="1" rowspan="1" align="center" valign="middle" width="93">WPL-<br />
30BE(304)</td>
<td class="et2" colspan="1" rowspan="1" align="center" valign="middle" width="93">WPL-<br />
45BE(304)</td>
<td class="et2" colspan="1" rowspan="1" align="center" valign="middle" width="93">WPL-<br />
65BE(304)</td>
<td class="et2" colspan="1" rowspan="1" align="center" valign="middle" width="82">WPL-<br />
85BE(304)</td>
<td class="et2" colspan="1" rowspan="1" align="center" valign="middle" width="82">WPL-<br />
125BE(304)</td>
<td class="et2" colspan="1" rowspan="1" width="113"></td>
</tr>
<tr>
<td class="et2" colspan="2"> Cycle Mode</td>
<td class="et2" colspan="6">Forced convection</td>
</tr>
<tr>
<td class="et2" rowspan="4" width="217">Function</td>
<td class="et2" width="217">Temp. range</td>
<td class="et2" colspan="6">RT+5-120℃</td>
</tr>
<tr>
<td class="et2" width="217">Temp. Resolution Ratio</td>
<td class="et2" colspan="6">0.1℃</td>
</tr>
<tr>
<td class="et2" width="217">Temp. Motion</td>
<td class="et2" colspan="6">±1℃</td>
</tr>
<tr>
<td class="et2" width="217">Temp. Uniformity</td>
<td class="et2" colspan="6">±1.0℃</td>
</tr>
<tr>
<td class="et2" rowspan="6" width="93">Structure</td>
<td class="et2" width="93">Inner Chamber</td>
<td class="et2" colspan="6">Mirror Stainless Steel</td>
</tr>
<tr>
<td class="et2" width="82">Outer Shell</td>
<td class="et2" colspan="6">Cold rolling steel electrostatic spraying exterior</td>
</tr>
<tr>
<td class="et2" width="217">Insulation layer</td>
<td class="et2" colspan="6">High quaility foam board</td>
</tr>
<tr>
<td class="et2" width="217">Heater</td>
<td class="et2" colspan="6">Stainless steel electric heating tube</td>
</tr>
<tr>
<td class="et2" width="217">Power rating</td>
<td class="et2" width="217">0.4kW</td>
<td class="et2" width="217">0.5kW</td>
<td class="et2" width="217">0.7kW</td>
<td class="et2" width="217">0.9kW</td>
<td class="et2" width="217">1.1kW</td>
<td class="et2" width="113">1.5kW</td>
</tr>
<tr>
<td class="et2" width="217">Exhaust hole</td>
<td class="et2" colspan="6">φ35mm top( with function of test hole)</td>
</tr>
<tr>
<td class="et2" colspan="1" rowspan="8" width="93">Controller</td>
<td class="et2" width="93">Temp control mode</td>
<td class="et2" colspan="6">Two temperature section intelligent PID</td>
</tr>
<tr>
<td class="et2" width="82">Temp. setting mode</td>
<td class="et2" colspan="6">Touch button setting</td>
</tr>
<tr>
<td class="et2" width="217">Temp. display mode</td>
<td class="et2" colspan="6">Measuring temperature: LCD upper screen;<br />
setting temperature: the lower row</td>
</tr>
<tr>
<td class="et2" width="93">Timer</td>
<td class="et2" colspan="6">0-9999min(with timing wait function)</td>
</tr>
<tr>
<td class="et2" width="93">Operation function</td>
<td class="et2" colspan="6">Fixed temperature operation,<br />
timing function, auto stop.</td>
</tr>
<tr>
<td class="et2" width="82">Additional function</td>
<td class="et2" colspan="6">Digital Independent temp.limiter.4 grades 3 speed ajustable speed fan (230 without fan speed adjuor)</p>
<p>Sensor deviation correction,temperature overshoot self-tuning,internal parameter locking,power-off parameter memory</td>
</tr>
<tr>
<td class="et2" width="92">Sensor</td>
<td class="et2" colspan="6">pt100</td>
</tr>
<tr>
<td class="et2" colspan="1" rowspan="1" width="93">          Safety device</td>
<td class="et2" colspan="6" rowspan="1">Over temp. sound-light alarm, digital independent temp, limiter</td>
</tr>
<tr>
<td class="et2" rowspan="9" width="82">Specification</td>
<td class="et2" width="82">Inner Chamber size(W*L*H)(mm)</td>
<td class="et2" width="217">310*310<br />
*310</td>
<td class="et2" width="92">350*350<br />
*350</td>
<td class="et2" width="93">400*360<br />
*450</td>
<td class="et2" width="93">450*420<br />
*450</td>
<td class="et2" width="93">500*450<br />
*550</td>
<td class="et2" width="82">600*500<br />
*750</td>
</tr>
<tr>
<td class="et2" width="82">Exterior size (W*L*H)(mm)</td>
<td class="et2" width="217">460*510<br />
*695</td>
<td class="et2" width="92">500*550<br />
*735</td>
<td class="et2" width="93">550*550<br />
*840</td>
<td class="et2" width="93">590*610<br />
*830</td>
<td class="et2" width="93">636*680<br />
*915</td>
<td class="et2" width="82">735*835<br />
*1115</td>
</tr>
<tr>
<td class="et2" width="82">Packing size (W*L*H)(mm)</td>
<td class="et2" width="217">540*575<br />
*855</td>
<td class="et2" width="217">580*615<br />
*895</td>
<td class="et2" width="217">635*625<br />
*995</td>
<td class="et2" width="92">680*685<br />
*1000</td>
<td class="et2" width="93">710*730<br />
*1100</td>
<td class="et2" width="93">857*885<br />
*1287</td>
</tr>
<tr>
<td class="et2" width="93">Volume</td>
<td class="et2" width="82">30L</td>
<td class="et2" width="82">45L</td>
<td class="et2" width="217">65L</td>
<td class="et2" width="92">85L</td>
<td class="et2" width="93">125L</td>
<td class="et2" width="93">230L</td>
</tr>
<tr>
<td class="et2" width="93">Shelf number</td>
<td class="et2" width="82">5</td>
<td class="et2" width="82">6</td>
<td class="et2" width="113">8</td>
<td class="et2" width="217">8</td>
<td class="et2" width="92">11</td>
<td class="et2" width="93">17</td>
</tr>
<tr>
<td class="et2" width="93">Load per rack</td>
<td class="et2" colspan="6">15kg</td>
</tr>
<tr>
<td class="et2" width="82">Shelf space</td>
<td class="et2" colspan="6">40mm</td>
</tr>
<tr>
<td class="et2" width="113">Current rating</td>
<td class="et2" width="217">220V/<br />
1.8A</td>
<td class="et2" width="undefined">220V/<br />
2.3A</td>
<td class="et2" width="undefined">220V/<br />
3.2A</td>
<td class="et2" width="undefined">220V/<br />
4.1A</td>
<td class="et2" width="undefined">220V/<br />
5A</td>
<td class="et2" width="undefined">220V/<br />
6.8A</td>
</tr>
<tr>
<td class="et2" width="undefined">NW/GW (kg）</td>
<td class="et2" width="undefined">33/37</td>
<td class="et2" width="undefined">37/43</td>
<td class="et2" width="undefined">44/49</td>
<td class="et2" width="undefined">50/56</td>
<td class="et2" width="undefined">60/66</td>
<td class="et2" width="undefined">94/120</td>
</tr>
<tr>
<td class="et2" colspan="1" rowspan="1" width="undefined"></td>
<td class="et2" colspan="1" rowspan="1" width="undefined">Shelf fame</td>
<td class="et2" colspan="6" rowspan="1" width="NaN">                                                      4</td>
</tr>
<tr>
<td class="et3" width="undefined"></td>
<td class="et2" width="undefined">Shelf</td>
<td class="et2" colspan="6">2</td>
</tr>
<tr>
<td class="et2" colspan="2">optional accessories</td>
<td class="et2" colspan="6">Shelf, U-disk storage, Printer, 3.5 inch color touch screen temperature controller</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<div class="ast-oembed-container " style="height: 100%;"><iframe loading="lazy" title="High Temperature Incubator/ WPL Incubator/ Lab equipment" width="1778" height="1000" src="https://www.youtube.com/embed/LU8u-pYemAc?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
<p>The post <a href="https://keylaser.am/product/constant-temperature-incubator/">Constant-temperature Incubator</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Constant-Temperature Incubator DH-BII</title>
		<link>https://keylaser.am/product/constant-temperature-incubator-dh-bii/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 25 Sep 2024 18:14:54 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=9148</guid>

					<description><![CDATA[<p><label>Model: </label>DH3600Ⅱ, DH4000Ⅱ, DH5000Ⅱ, DH6000Ⅱ,DH3600BⅡ, DH4000BⅡ, DH5000BⅡ, DH6000BⅡ</p>
<p><label>Brand: </label>FAITHFUL</p>
<p>The post <a href="https://keylaser.am/product/constant-temperature-incubator-dh-bii/">Constant-Temperature Incubator DH-BII</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1. New panel 5 degree angle, new glass inner door knob switch.</p>
<p>2. The double door structure adopts high quality glass, easy to observe samples, the door with magnetic strip is easy to be opened and closed, good sealing and open door power-off function.</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>The post <a href="https://keylaser.am/product/constant-temperature-incubator-dh-bii/">Constant-Temperature Incubator DH-BII</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
