<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Laboratory Equipments Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-tag/laboratory-equipments/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-tag/laboratory-equipments/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Mon, 23 Mar 2026 06:21:10 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>Laboratory Equipments Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-tag/laboratory-equipments/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>CO2 Incubator 50L 80L 160L 180L 220L 300L</title>
		<link>https://keylaser.am/product/co2-incubator-50l-80l-160l-180l-220l-300l/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 23 Mar 2026 06:21:10 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14878</guid>

					<description><![CDATA[<p><label>Model: </label>BJPX-C50D BJPX-C80D BJPX-C160D BJPX-C180D BJPX-C220D BJPX-C300D</p>
<p>Carbon dioxide(CO2) incubators provide optimal growing conditions and contamination prevention for valuable cell cultures. BIOBASE provides a wide range of CO2 incubators, ranging from a small capacity and volume to a large scale capacity cabinet.</p>
<p>The post <a href="https://keylaser.am/product/co2-incubator-50l-80l-160l-180l-220l-300l/">CO2 Incubator 50L 80L 160L 180L 220L 300L</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. IR infrared sensor, using dual-channel dual-filter infrared technology.</p>
<p>2. The inner tank is designed with full-radius corners and the surface is made of 304 mirror finish stainless steel.</p>
<p>3. Adopt double heating module, six side heating.</p>
<p>4. The cavity is uniformly heated by silicone rubber heating wire heater with aluminum foil-wrapped, offering rapid temperature rise and good uniformity.</p>
<p>5. Equipped with leakage current and over-voltage protectors. Features over-temperature, under-temperature, over-concentration and under-concentration alarms.</p>
<p>6. HEPA high-efficiency filter, with a filtration efficiency of 99.97%.</p>
<p>7. HermeSEAL<sup>®</sup> technology, with its patented encapsulated infrared assembly, resists high temperature, high humidity, and corrosive environments, ensuring long-term stability even in harsh conditions.</p>
<p>8. The sensor prevents condensation upon power-on, avoiding failures caused by moisture and ensuring more stable and reliable measurements.</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BJPX-C50D</td>
<td>BJPX-C80D</td>
<td>BJPX-C160D</td>
<td>BJPX-C180D</td>
<td>BJPX-C220D</td>
<td>BJPX-C300D</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Type</td>
<td colspan="6">Dry heat series, air jacket</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sterilization Type</td>
<td colspan="6">180℃ dry heat sterilization</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Capacity</td>
<td>50L</td>
<td>80L</td>
<td>160L</td>
<td>180L</td>
<td>220L</td>
<td>300L</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Sensor</td>
<td colspan="6">PT100</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temp. Range</td>
<td colspan="6">RT+5~60℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Fluctuation</td>
<td colspan="6">±0.5℃ (@37℃: ±0.3℃)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temp. Uniformity</td>
<td colspan="6">±1.0℃ (@37℃: ±0.5℃)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Precision</td>
<td colspan="6">0.1℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Timing Range</td>
<td colspan="6">0~999h59min or continuos</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Display</td>
<td colspan="6">7-inch touch screen</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>CO<sub>2</sub> Control</td>
<td colspan="6">IR infrared sensor with calibration certificate</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>CO<sub>2</sub> Range</td>
<td colspan="6">0~20vol%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>CO<sub>2</sub> Uniformity</td>
<td colspan="6">0.2vol%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>CO<sub>2</sub> Control Resolution</td>
<td colspan="6">0.1vol%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Ambient Temperature and Humidity</td>
<td colspan="6">Ambient temperature: 18~30℃ (Recommendation: 25±2℃)</p>
<p>Ambient humidity: ≤80%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Filter</td>
<td colspan="6">CO<sub>2 </sub>gas filter</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power Supply</td>
<td colspan="6">AC220V, 50/60Hz (Standard); 110V, 50/60Hz (Optional) (External transformer)</p>
<p>Wiring method: plug</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Consumption</td>
<td>1850W</td>
<td>1900W</td>
<td>1950W</td>
<td>2000W</td>
<td>2050W</td>
<td>2650W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Shelves</td>
<td colspan="6">2pcs, adjustable</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Standard Accessories</td>
<td colspan="6">Shelves, USB interface, CO<sub>2</sub> relief valve, water tank, CO<sub>2 </sub>gas filter</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Optional Accessory</td>
<td colspan="6">Three-way connector</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Internal Size(W*D*H)</td>
<td>332*326*496mm</td>
<td>401*352*576mm</td>
<td>551*462*646mm</td>
<td>451*506*716mm</td>
<td>502*545*786mm</td>
<td>534*565*996mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size(W*D*H)</td>
<td>660*552*764mm</td>
<td>688*622*850mm</td>
<td>870*710*958mm</td>
<td>770*722*992mm</td>
<td>820*762*1060mm</td>
<td>860*802*1260mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Package Size(W*D*H)</td>
<td>730*642*784mm</td>
<td>758*712*870mm</td>
<td>940*800*978mm</td>
<td>840*812*1012mm</td>
<td>890*852*1260mm</td>
<td>930*892*1460mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Net Weight</td>
<td>80kg</td>
<td>90kg</td>
<td>115kg</td>
<td>125kg</td>
<td>137kg</td>
<td>169.5kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>95kg</td>
<td>105kg</td>
<td>130kg</td>
<td>140kg</td>
<td>152kg</td>
<td>184.5kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/co2-incubator-50l-80l-160l-180l-220l-300l/">CO2 Incubator 50L 80L 160L 180L 220L 300L</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Large Capacity Vertical Type Shaking Incubator 610L</title>
		<link>https://keylaser.am/product/large-capacity-vertical-type-shaking-incubator-610l/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 19 Mar 2026 15:37:22 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14824</guid>

					<description><![CDATA[<p><label>Model: </label>BJPX-SL220-LI</p>
<p>The vertical dual-door single-control shaking incubator is a versatile laboratory instrument that integrates an incubator and an orbital shaker. The front double-door design offers greater flexibility in operation and handling. It is widely used for bacterial culture, fermentation, hybridization, biochemical reactions, as well as research on enzymes and tissues, where precise temperature and oscillation frequency control are critical.</p>
<p>The post <a href="https://keylaser.am/product/large-capacity-vertical-type-shaking-incubator-610l/">Large Capacity Vertical Type Shaking Incubator 610L</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img fetchpriority="high" decoding="async" class="wp-image-14826 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/BJPX-ZK50A-800-800-2.webp" alt="Large Capacity Vertical Type Shaking Incubator 610L" width="944" height="197" srcset="https://keylaser.am/wp-content/uploads/2026/03/BJPX-ZK50A-800-800-2.webp 944w, https://keylaser.am/wp-content/uploads/2026/03/BJPX-ZK50A-800-800-2-300x63.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/BJPX-ZK50A-800-800-2-768x160.webp 768w, https://keylaser.am/wp-content/uploads/2026/03/BJPX-ZK50A-800-800-2-600x125.webp 600w" sizes="(max-width: 944px) 100vw, 944px" /></p>
<p><strong>Features:</strong></p>
<p>1. Exterior material is powder-coated carbon steel, interior material is mirror finished stainless steel.</p>
<p>2. The temperature is controlled by a &#8216;Super Fuzzy PID&#8217; system, featuring smaller overshoot, faster stabilization time, and better temperature control accuracy.</p>
<p>3. High-quality DC brushless motor features minimal vibration, low noise, high efficiency, maintenance-free operation, energy saving, and long-lasting performance. Equipped with single-axis balanced drive technology for ultra-low silent operation.</p>
<p>4. Equipped with over/under temperature alarms and abnormal shutdown alarms.</p>
<p>5. Automatic audio and visual alarms are triggered in case of shaker(Motor) malfunction or if the door is not properly closed.</p>
<p>6. The motor rotation direction can be set to forward, reverse, or alternating forward/reverse.</p>
<p>7. Programmed mode, which allows for multi-stage settings, and constant mode, which runs continuously at the set temperature and speed after configuration.</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BJPX-SL220-LI</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Capacity</td>
<td>610L</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temperature Control Range</td>
<td>4~60℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature Control Accuracy</td>
<td>0.1℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temperature Uniformity</td>
<td>≤±1℃(@37℃)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature Fluctuation</td>
<td>≤±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Ambient Temperature</td>
<td>15~35℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Timing Range</td>
<td>0~999min(h)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Control Mode</td>
<td>PID microcomputer control</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Display</td>
<td>LCD touch screen</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Circulation Mode</td>
<td>Forced convection</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Oscillation Mode</td>
<td>Rotary shaking</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Speed Range</td>
<td>30~300rpm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Speed Accuracy</td>
<td>±1rpm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Swing Amplitude of The Plate</td>
<td>φ26mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Refrigerant</td>
<td>R290/150g</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Standard Capacity</td>
<td>250ml*64/500ml*48(Default shipping configuration)/1000ml*32/2000ml*20/3000ml*16/5000*12</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Max. Capacity</td>
<td>Clamp flask: 50ml*162/100ml*124/150ml*104/250ml*86/500ml*64/1000ml*32/2000ml*20/3000ml*16/5000ml*12</p>
<p>Tube rack*6</p>
<p>96-well plate*30</p>
<p>Clamp rod shaking plate*4</p>
<p>Horizontal thermostatic shaker spring plate*2</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Defrost Function</td>
<td>Automatic defrosting</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Consumption</td>
<td>1500W</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Power Supply</td>
<td>AC220V, 50Hz(Standard); 110V, 60Hz(Optional)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Shelf</td>
<td>970*460mm*2</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Standard Accessory</td>
<td>UV light*1, LED light*1</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Optional Accessory</td>
<td>Printer, USB interface</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Internal Size(W*D*H)</td>
<td>1198*520*990mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size(W*D*H)</td>
<td>1303*793*1564mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Package Size(W*D*H)</td>
<td>1450*980*1750mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Net Weight</td>
<td>550kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>580kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/large-capacity-vertical-type-shaking-incubator-610l/">Large Capacity Vertical Type Shaking Incubator 610L</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Large Capacity Vertical Type Shaking Incubator(Double Door &#038; Double Layer)</title>
		<link>https://keylaser.am/product/large-capacity-vertical-type-shaking-incubatordouble-door-double-layer/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 19 Mar 2026 15:33:30 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14819</guid>

					<description><![CDATA[<p><label>Model: </label>BJPX-SL220-LII</p>
<p>Vertical dual-door dual-control shaking incubator(Also known as an oscillator or constant temperature shaker) integrates an incubator and shaker into one unit. It is typically placed on the floor for mixing and culturing samples. The front-opening design provides greater operational flexibility compared to top-lift shakers. It meets the demands of modern laboratories with increasing sample volumes and supports large-scale production in bioengineering.</p>
<p>The post <a href="https://keylaser.am/product/large-capacity-vertical-type-shaking-incubatordouble-door-double-layer/">Large Capacity Vertical Type Shaking Incubator(Double Door &#038; Double Layer)</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. Exterior material is powder-coated carbon steel, interior material is stainless steel.</p>
<p>2. The unique airflow duct design ensures superior temperature uniformity within the chamber, enabling more accurate temperature sensor data acquisition.</p>
<p>3. The temperature is controlled by a &#8216;Super Fuzzy PID&#8217; system, featuring smaller overshoot, faster stabilization time, and better temperature control accuracy.</p>
<p>4. Features a brushless DC motor with PWM speed control. The acceleration control circuit ensures gentle startup, smooth acceleration, and safe handling of experimental samples.</p>
<p>5. Three-dimensional biased three-wheel drive mechanism provides exceptionally smooth, stable, durable, and reliable operation.</p>
<p>6. The outer door utilizes insulated tempered electric heating glass that effectively prevents glass fogging and condensation around the door frame.</p>
<p>7. Our proprietary silicone sealing strip, made from eco-friendly silicone material, provides superior contact with the chamber surface for enhanced sealing and improved thermal insulation performance.</p>
<p>8. The motor rotation direction can be set to forward, reverse, or alternating forward/reverse.</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BJPX-SL220-LII</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Capacity</td>
<td>456L</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temperature Control Range</td>
<td>4~60℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature Control Accuracy</td>
<td>0.1℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temperature Uniformity</td>
<td>≤±1℃(@37℃)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature Fluctuation</td>
<td>≤±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Ambient Temperature</td>
<td>15~35℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Timing Range</td>
<td>0~9999min/h</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Control Mode</td>
<td>PID microcomputer control</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Display</td>
<td>LCD display</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Circulation Mode</td>
<td>Forced convection</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Oscillation Mode</td>
<td>Rotary shaking</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Speed Range</td>
<td>30~300rpm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Speed Accuracy</td>
<td>±1rpm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Swing Amplitude of The Plate</td>
<td>φ26mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Refrigerant</td>
<td>R290/150g</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Standard Capacity</td>
<td>Capacity per column:<br />
Upper layer: 250ml*20(Default shipping configuration)/500ml*12/</p>
<p>1000ml*9/2000ml*6<br />
Lower layer: universal spring clamps</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Max. Capacity</td>
<td>Upper layer:</p>
<p>Clamp flask: 100ml*72/250ml*50/500ml*32/1000ml*18/2000ml*16</p>
<p>Lower layer:</p>
<p>Clamp flask: 100ml*48/250ml*40/500ml*24/1000ml*18/2000ml*8</p>
<p>Tube rack*8</p>
<p>96-well plate*48</p>
<p>Clamp rod shaking plate*4</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Defrost Function</td>
<td>Automatic defrosting</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Consumption</td>
<td>2000W</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Power Supply</td>
<td>AC220V, 50Hz(Standard); 110V, 60Hz(Optional)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Shelf</td>
<td>503*463mm*4</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Standard Accessory</td>
<td>UV light*2, LED light*2</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Optional Accessory</td>
<td>Printer, USB interface</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Internal Size(W*D*H)</td>
<td>558*504*813mm(Per column)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size(W*D*H)</td>
<td>1303*784*1621mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Package Size(W*D*H)</td>
<td>1450*980*1750mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Net Weight</td>
<td>506kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>570kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/large-capacity-vertical-type-shaking-incubatordouble-door-double-layer/">Large Capacity Vertical Type Shaking Incubator(Double Door &#038; Double Layer)</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Vacuum Drying Oven 25L 50L 25L 50L</title>
		<link>https://keylaser.am/product/vacuum-drying-oven-25l-50l-25l-50l/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 19 Mar 2026 15:29:47 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14813</guid>

					<description><![CDATA[<p><label>Model: </label>BJPX-ZK25A BJPX-ZK50A BJPX-ZK25B BJPX-ZK50B</p>
<p>Vacuum drying ovens are widely used in biochemistry, chemical pharmaceuticals, healthcare, agricultural research, and environmental protection. They are suitable for powder drying, baking, and sterilization of glassware, as well as efficient drying of heat-sensitive, easily decomposable, oxidizable, and complex-component materials.</p>
<p>The post <a href="https://keylaser.am/product/vacuum-drying-oven-25l-50l-25l-50l/">Vacuum Drying Oven 25L 50L 25L 50L</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. The housing is made of cold-rolled steel plate with electrostatic spray coating, and the inner chamber has rounded corners for easy cleaning.</p>
<p>2. The door and chamber are sealed with a specially designed silicone gasket to maintain vacuum, while allowing easy opening in non-vacuum conditions.</p>
<p>3. The temperature control system uses a microcomputer PID design with an intelligent color LCD display, providing precise temperature regulation, timing, and over-temperature alarm functions.</p>
<p>4. The double-layered glass door allows clear observation of items inside the chamber.</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="1781">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td width="147">Model</td>
<td width="184">BJPX-ZK25A</td>
<td width="184">BJPX-ZK50A</td>
<td width="184">BJPX-ZK25B</td>
<td width="184">BJPX-ZK50B</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="147">Capacity</td>
<td width="184">25L</td>
<td width="184">50L</td>
<td width="184">25L</td>
<td width="184">50L</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="147">Temp. Range</td>
<td colspan="4">RT+10~250℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="147">Temp. Resolution</td>
<td colspan="4">0.1℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="147">Vacuum Degree</td>
<td colspan="4">＜133Pa</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="147">Working Chamber Material</td>
<td colspan="2">201 stainless steel</td>
<td colspan="2">304 stainless steel</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="184">Standard Accessory</td>
<td colspan="4">Shelf*2, vacuum tube</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="147">Optional Accessory</td>
<td colspan="4">Vacuum pump: 2XZ-2(AC220V, 50Hz; 220V, 60Hz; 110V, 60Hz), printer, RS485 interface, remote control function, USB interface, programmable temperature controller</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="184">Consumption</td>
<td width="184">600W</td>
<td width="184">1400W</td>
<td width="184">600W</td>
<td width="147">1400W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="184">Power Supply</td>
<td colspan="4">AC220V, 50/60Hz(Standard); 110V, 50/60Hz(Optional)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="184">Internal Size(W*D*H)</td>
<td width="184">300*300*275mm</td>
<td width="147">415*370*345mm</td>
<td width="184">300*300*275mm</td>
<td width="184">415*370*345mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="184">External Size(W*D*H)</td>
<td width="184">595*455*455mm</td>
<td width="147">720*555*535mm</td>
<td width="184">595*455*455mm</td>
<td width="184">720*555*535mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="184">Package Size(W*D*H)</td>
<td width="184">670*530*550mm</td>
<td width="147">770*630*620mm</td>
<td width="184">670*530*550mm</td>
<td width="184">770*630*620mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="184">Net Weight</td>
<td width="184">40kg</td>
<td width="undefined">59kg</td>
<td width="undefined">40kg</td>
<td width="undefined">59kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="undefined">Gross Weight</td>
<td width="undefined">45kg</td>
<td width="undefined">65kg</td>
<td width="undefined">45kg</td>
<td width="undefined">65kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/vacuum-drying-oven-25l-50l-25l-50l/">Vacuum Drying Oven 25L 50L 25L 50L</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Portable Constant-Temperature Incubator</title>
		<link>https://keylaser.am/product/portable-constant-temperature-incubator/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 19 Mar 2026 15:25:25 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14809</guid>

					<description><![CDATA[<p><label>Model: </label>BJPX-H10</p>
<p>Suitable for scientific research departments such as industrial and mining enterprises, medical and health care, biochemistry, and agricultural science for bacterial cultivation, breeding, fermentation and other related experimental purposes.</p>
<p>The post <a href="https://keylaser.am/product/portable-constant-temperature-incubator/">Portable Constant-Temperature Incubator</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. LCD display shows multiple sets of data simultaneously.</p>
<p>2. Contactless circuit control system, features upper-limit alarm and timed auto power-off functions.</p>
<p>3. Acrylic material observation window with an independently switchable lighting system.</p>
<p>4. Four-sided surround heating technology ensures uniform temperature distribution inside the chamber.</p>
<p>5. Adjustable sliding shelves allow flexible height configuration.</p>
<p>6. Silicone rubber magnetic seal provides easy opening/closing and excellent airtightness.</p>
<p>7. Supports portable power supply for field operation.</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="100%">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td width="265">Model</td>
<td width="616">BJPX-H10</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="265">Capacity</td>
<td width="616">10L</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="265">Display</td>
<td width="616">LCD display</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="265">Circulation Mode</td>
<td width="616">Four-sided heating, natural convection</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="265">Temp. Range</td>
<td width="616">RT+5~65℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="265">Temp. Resolution</td>
<td width="616">0.1℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="265">Temp. Fluctuation</td>
<td width="616">±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="265">Timing Range</td>
<td width="616">99h59min</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="265">Standard Accessory</td>
<td width="616">Shelf*2</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="265">Consumption</td>
<td width="616">300W</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="265">Power Supply</td>
<td width="616">AC220V, 50/60Hz(Standard); 110V, 50/60Hz(Optional)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="265">Internal Size(W*D*H)</td>
<td width="616">200*220*230mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="265">External Size(W*D*H)</td>
<td width="616">300*280*350mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="265">Package Size(W*D*H)</td>
<td width="616">380*365*415mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="265">Net Weight</td>
<td width="616">9.5kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="265">Gross Weight</td>
<td width="616">12kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/portable-constant-temperature-incubator/">Portable Constant-Temperature Incubator</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Mould Incubator 100L 150L 200L 250L</title>
		<link>https://keylaser.am/product/mould-incubator-100l-150l-200l-250l/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 19 Mar 2026 15:19:21 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14801</guid>

					<description><![CDATA[<p><label>Model: </label>BJPX-MB100 BJPX-MB150 BJPX-MB200 BJPX-MB250</p>
<p>The post <a href="https://keylaser.am/product/mould-incubator-100l-150l-200l-250l/">Mould Incubator 100L 150L 200L 250L</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. 7.0-inch touch display screen, simple and easy to understand and operate, convenient for observation.</p>
<p>2. Double-layer glass door design, the outer door is equipped with an extra-large viewing window for easy observation.</p>
<p>3. Unique automatic defrost design, with minimal temperature fluctuation during defrosting.</p>
<p>4. Mirror-finished stainless steel interior, rounded corners, shelves are removable and height-adjustable, easy to clean, and helps maintain a clean working chamber environment.</p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BJPX-MB100</td>
<td>BJPX-MB150</td>
<td>BJPX-MB200</td>
<td>BJPX-MB250</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Capacity</td>
<td>100L</td>
<td>150L</td>
<td>200L</td>
<td>250L</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Sensor</td>
<td colspan="4">PT100</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temp. Range</td>
<td colspan="4">0~60℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Fluctuation</td>
<td colspan="4">±1℃(@37℃)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temp. Uniformity</td>
<td colspan="4">±2℃(@37℃)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Precision</td>
<td colspan="4">0.1℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Timing Range</td>
<td colspan="4">0~9999h59min</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Humidity Range</td>
<td colspan="4">50~90%RH(@20~50℃)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Humidity Control Accuracy</td>
<td colspan="4">1%RH</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Humidity Control Fluctuation</td>
<td colspan="4">≤±8%RH</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Refrigerant</td>
<td colspan="4">R134a(CFC-free environmentally friendly refrigerant)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sterilization Method</td>
<td colspan="4">UV sterilization lamp(Timetable setting)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power Supply</td>
<td colspan="4">AC220V, 50Hz(Standard); 110V, 60Hz(Optional, external transformer)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Consumption</td>
<td colspan="2">1200W</td>
<td colspan="2">1500W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Shelves</td>
<td colspan="2">2</td>
<td colspan="2">3</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Standard Accessories</td>
<td colspan="4">UV sterilization lamp, printer, BOD waterproof socket, test port</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Optional Accessories</td>
<td colspan="4">USB interface, automatic water supply system</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Internal Size(W*D*H)</td>
<td>500*350*580mm</td>
<td>550*401*690mm</td>
<td>600*450*750mm</td>
<td>660*450*850mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size(W*D*H)</td>
<td>644*647*1170mm</td>
<td>690*692*1270mm</td>
<td>742*743*1340mm</td>
<td>802*743*1440mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Package Size(W*D*H)</td>
<td>769*772*1327mm</td>
<td>815*817*1327mm</td>
<td>865*867*1497mm</td>
<td>865*927*1597mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Net Weight</td>
<td>105kg</td>
<td>120kg</td>
<td>130kg</td>
<td>145kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>120kg</td>
<td>140kg</td>
<td>150kg</td>
<td>170kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/mould-incubator-100l-150l-200l-250l/">Mould Incubator 100L 150L 200L 250L</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Optional Shaking Incubator Accessories</title>
		<link>https://keylaser.am/product/optional-shaking-incubator-accessories/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 18 Mar 2026 17:46:47 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14774</guid>

					<description><![CDATA[<p>Enhance the versatility and functionality of your laboratory shakers with our range of Optional Shaker Accessories. Designed to fit seamlessly with a variety of shaker models, these accessories allow you to customize your equipment to meet specific experimental needs, ensuring optimal performance and efficiency in your lab.</p>
<p>The post <a href="https://keylaser.am/product/optional-shaking-incubator-accessories/">Optional Shaking Incubator Accessories</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" class=" lazyloaded" title="optional shaker accessories" src="https://img.waimaoniu.net/2587/2587-202405221103538233.png" alt="optional shaker accessories" data-original="https://img.waimaoniu.net/2587/2587-202405221103538233.png" /></p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="100%">
<colgroup>
<col />
<col />
<col />
<col />
<col />
<col /></colgroup>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td width="48">No.</td>
<td width="132">Material code</td>
<td width="214">Name</td>
<td width="77">No.</td>
<td width="221">Specifications</td>
<td width="189">Note</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="48">1</td>
<td width="132">18.01.09.00001</td>
<td rowspan="10" width="214">Flask Clamp</td>
<td width="77">BS-A10</td>
<td width="221">50ml</td>
<td rowspan="7" width="189">Suitable for<br />
BJPX-ST10/11/20<br />
BJPX-SL10/20<br />
BJPX-SDT10/20<br />
BJPX-SDL10/20<br />
BJPX-SDW10/20<br />
BJPX-SW10/20<br />
BJPX-SW10-L<br />
BJPX-SW20-L<br />
BJPX-SL10-L<br />
BJPX-SL20-L<br />
BJPX-ST10-L<br />
BJPX-ST11-L<br />
BJPX-SDW10-L<br />
BJPX-SDW20-L<br />
BJPX-SL220-LI<br />
BJPX-SL220-LII</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="48">2</td>
<td width="132">18.01.09.00002</td>
<td width="77">BS-A11</td>
<td width="221">100ml</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="48">3</td>
<td width="132">18.01.09.00003</td>
<td width="77">BS-A12</td>
<td width="221">150ml</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="48">4</td>
<td width="132">18.01.09.00004</td>
<td width="77">BS-A13</td>
<td width="221">200ml</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="48">5</td>
<td width="132">18.01.09.00005</td>
<td width="77">BS-A14</td>
<td width="221">250ml</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="48">6</td>
<td width="132">18.01.09.00006</td>
<td width="77">BS-A15</td>
<td width="221">500ml</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="48">7</td>
<td width="132">18.01.09.00007</td>
<td width="77">BS-A16</td>
<td width="221">1000ml</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="48">8</td>
<td width="132">18.01.09.00008</td>
<td width="77">BS-A17</td>
<td width="221">2000ml</td>
<td width="189">Suitable for<br />
BJPX-ST10/11/20<br />
BJPX-SDL10/20<br />
BJPX-SDT10/20<br />
BJPX-SW10/20<br />
BJPX-SW10-L<br />
BJPX-SW20-L<br />
BJPX-SDL10/20<br />
BJPX-SDW10/20<br />
BJPX-SDW10-L<br />
BJPX-SDW20-L<br />
BJPX-SL220-LI<br />
BJPX-SL220-LII</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="48">9</td>
<td width="132">18.01.09.00009</td>
<td width="77">BS-A18</td>
<td width="221">3000ml</td>
<td width="189">Suitable for<br />
BJPX-ST10/11/20<br />
BJPX-SW10/20<br />
BJPX-SDL10/20<br />
BJPX-SDW10/20<br />
BJPX-SDW10-L<br />
BJPX-SDW20-L<br />
BJPX-SL220-LI</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="48">10</td>
<td width="132">18.01.09.00010</td>
<td width="77">BS-A19</td>
<td width="221">5000ml</td>
<td width="189">Suitable for<br />
BJPX-SW10/20<br />
BJPX-SDL10/20<br />
BJPX-SW10-L<br />
BJPX-SW20-L<br />
BJPX-SL220-LI</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="48">11</td>
<td width="132">18.01.09.00011</td>
<td width="214">Microplate/96-well plate</td>
<td width="77">BS-A30</td>
<td width="221">130*87*52ml</td>
<td width="189">Suitable for<br />
BJPX-ST10/11/20<br />
BJPX-SW10/20<br />
BJPX-SL10/20<br />
BJPX-SDT10/20<br />
BJPX-SDL10/20<br />
BJPX-ST11-L<br />
BJPX-ST10-L<br />
BJPX-SL20-L<br />
BJPX-SL10-L<br />
BJPX-SW10-L<br />
BJPX-SW20-L<br />
BJPX-SDW10/20<br />
BJPX-SDW10-L<br />
BJPX-SDW20-L<br />
BJPX-SL220-LI<br />
BJPX-SL220-LII</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="48">12</td>
<td width="132">18.01.09.00012</td>
<td rowspan="13" width="214">Tube Rack</td>
<td width="77">BS-A20</td>
<td width="221">54*10ml</td>
<td rowspan="13" width="189">Suitable for<br />
BJPX-ST10/11/20<br />
BJPX-SL10/20<br />
BJPX-SW10/20<br />
BJPX-SDT10/20<br />
BJPX-SDL10/20<br />
BJPX-SDW10/20<br />
BJPX-SW10-L<br />
BJPX-SW20-L<br />
BJPX-SL10-L<br />
BJPX-SL20-L<br />
BJPX-SDW10-L<br />
BJPX-SDW20-L<br />
BJPX-SL220-LI<br />
BJPX-SL220-LII</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="48">13</td>
<td width="132">18.01.09.00013</td>
<td width="77">BS-A21</td>
<td width="221">54*15ml</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="48">14</td>
<td width="132">18.01.09.00014</td>
<td width="77">BS-A22</td>
<td width="221">28*50ml</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="48">15</td>
<td width="132">18.01.09.00015</td>
<td width="77">BS-A23</td>
<td width="221">24*100ml</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="48">16</td>
<td width="132">18.01.09.00016</td>
<td width="77">BS-A24</td>
<td width="221">54-well, suitable forΦ15*150 centrifuge tubes</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="48">17</td>
<td width="132">18.01.09.00017</td>
<td width="77">BS-A25</td>
<td width="221">54-well, suitable forΦ18*180 centrifuge tubes</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="48">18</td>
<td width="132">18.01.09.00018</td>
<td width="77">BS-A26</td>
<td width="221">54-well, suitable forΦ20*200 centrifuge tubes</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="48">19</td>
<td width="132">18.01.09.00019</td>
<td width="77">BS-A27</td>
<td width="221">32-well, suitable forΦ25mm*200mm centrifuge tubes</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="48">20</td>
<td width="132">18.01.09.00020</td>
<td width="77">BS-A28</td>
<td width="221">28-well, suitable forΦ30mm*200mm centrifuge tubes</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="48">21</td>
<td width="132">18.01.09.00021</td>
<td width="77">BS-A50</td>
<td width="221">54*7ml</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="48">22</td>
<td width="132">18.01.09.00022</td>
<td width="77">BS-A51</td>
<td width="221">54*10ml</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="48">23</td>
<td width="132">18.01.09.00023</td>
<td width="77">BS-A52</td>
<td width="221">54*20ml</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="48">24</td>
<td width="132">18.01.09.00024</td>
<td width="77">BS-A53</td>
<td width="221">54*30ml</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="48">25</td>
<td width="132">18.01.09.00025</td>
<td width="214">Universal attachment with 3 bars</td>
<td width="77">BS-A40</td>
<td width="221">320*300*70ml</td>
<td width="189">Suitable for 2000ml or larger beakers</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="48">26</td>
<td width="132">23.02.09999</td>
<td width="214">Horizontal thermostatic shaker spring plate</td>
<td width="77">SW20</td>
<td width="221">900*470ml</td>
<td width="189">Suitable for</p>
<p>BJPX-SW10</p>
<p>BJPX-SW10-L<br />
BJPX-SW20<br />
BJPX-SW20-L<br />
BJPX-SL220-LI</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="48">27</td>
<td width="132">23.02.10000</td>
<td width="214">Universal Spring plate(Stacked Large Capacity Shaking Incubator<br />
-A layer)</td>
<td width="77">SDT10</td>
<td width="221">420x400ml</td>
<td width="189">Suitable for</p>
<p>BJPX-SDT10</p>
<p>BJPX-SDT20</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="48">28</td>
<td width="132">23.02.10002</td>
<td width="214">Universal spring plate(Stacked Large Capacity Shaking Incubator<br />
&#8211; Two layers)</td>
<td width="77">SDL20</td>
<td width="221">460&#215;450(One layer spring plate, two layer flask clamp)</td>
<td width="189">Suitable for</p>
<p>BJPX-SDL10</p>
<p>BJPX-SDL20</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="48">29</td>
<td width="132">23.02.10003</td>
<td width="214">Universal spring plate(Stacked Large Capacity Shaking Incubator)</td>
<td width="77">SDW10</td>
<td width="221">720*490ml</td>
<td width="189">Suitable for</p>
<p>BJPX-SDW10</p>
<p>BJPX-SDW10-L BJPX-SDW20</p>
<p>BJPX-SDW20-L</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="48">30</td>
<td width="132">23.02.09013</td>
<td rowspan="2" width="214">Universal Spring plate(Small Capacity Thermostatic Shaking Incubator)</td>
<td width="77">ST10</td>
<td width="221">562*343ml</td>
<td width="189">Suitable for</p>
<p>BJPX-ST10</p>
<p>BJPX-ST11</p>
<p>BJPX-ST20</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="48">31</td>
<td width="132">23.02.09014</td>
<td width="77">ST10-L</td>
<td width="221">202*202ml</td>
<td width="189">Suitable for</p>
<p>BJPX-ST10-L</p>
<p>BJPX-ST11-L</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="48">32</td>
<td width="132">23.02.09016</td>
<td width="214">Universal Spring plate(Stacked Large Capacity Shaking Incubator)</td>
<td width="77">SL20-L</td>
<td width="221">446*393(Upper and lower spring plate)</td>
<td width="189">Suitable for</p>
<p>BJPX-SL20-L</p>
<p>BJPX-SL20</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="48">33</td>
<td width="132">23.02.10004</td>
<td width="214">Double-Layer flask plate(Stacked Large Capacity Shaking Incubator)</td>
<td width="77">SL20-L2</td>
<td width="221">446*393(Upper and lower Flask Clamp)</td>
<td width="189">Suitable for</p>
<p>BJPX-SL20-L</p>
<p>BJPX-SL20</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/optional-shaking-incubator-accessories/">Optional Shaking Incubator Accessories</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Vertical Type Shaking Incubator</title>
		<link>https://keylaser.am/product/vertical-type-shaking-incubator/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 16 Mar 2026 17:42:43 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14599</guid>

					<description><![CDATA[<p><label>Model: </label>BJPX-SL10-L BJPX-SL10 BJPX-SL20-L BJPX-SL20</p>
<p>The Vertical Type Shaking Incubator is a versatile laboratory device designed for cultivating microorganisms, cell cultures, and other biological samples that require controlled temperature and shaking conditions.</p>
<p>The post <a href="https://keylaser.am/product/vertical-type-shaking-incubator/">Vertical Type Shaking Incubator</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>1. Large hollow electric heating perspective window, anti-condensation, convenient for customers to check the running condition of the box.</p>
<p>2. The display interface has the functions of historical data, curve, alarm record can be queried, data can be saved and exported, password lock screen protection and Chinese and English switching.</p>
<p>3. Humanized design of the door stop function, to protect the safety of personnel.</p>
<p>4. Box padding foot height adjustable, standard universal casters, easy to move the box.</p>
<p>5. Professionally designed side air vents to meet the oxygen requirement of samples.</p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BJPX-SL10-L</td>
<td colspan="2">BJPX-SL10</td>
<td>BJPX-SL20-L</td>
<td>BJPX-SL20</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Display</td>
<td>LCD</td>
<td colspan="2">7 inch touch screen</td>
<td>LCD</td>
<td>7 inch touch screen</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Circulation Mode</td>
<td colspan="5">Forced convection</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Shaking Mode</td>
<td colspan="5">Rotary shaking</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Drive Mode</td>
<td colspan="5">Three axis balanced drive type</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Vibration Range</td>
<td colspan="5">Φ26mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Rotating Speed</td>
<td colspan="5">30~300rpm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Rotating Accuracy</td>
<td colspan="5">±1r/min</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Range</td>
<td colspan="3">RT+5~60℃</td>
<td colspan="2">4~60℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temp. Control Accuracy</td>
<td colspan="5">0.1℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Uniformity</td>
<td colspan="5">≤±1℃(37℃）</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temp. Fluctuation</td>
<td colspan="5">≤±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Timing Range</td>
<td>0~9999min(h)</td>
<td colspan="2">0~999h59min</td>
<td>0~9999min(h)</td>
<td>0~999h59min</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Shaking Plate Size</td>
<td colspan="5">413*466mm(Two layers)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Max. Capacity</td>
<td colspan="5">Upper Layer: 100ml*25 or 250ml*16 or 500ml*12 or 1000ml*9(Flask clamp)</p>
<p>Lower Layer: 100ml*20 or 250ml*12 or 500ml*9 or 1000ml*6(Flask clamp)</p>
<p>Tube Rack*2</p>
<p>96-well Plate*16</p>
<p>Clamping Rod Shaking Plate*2</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Standard. Capacity</td>
<td colspan="5">Upper Layer: 250ml*12 or 500ml*9 or 1000ml*6(Flask clamp)</p>
<p>Lower Layer: Universal spring rack</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Lighting Mode</td>
<td colspan="5">LED lamp*1</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Sterilization Mode</td>
<td colspan="5">UV lamp*1</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Refrigerant</td>
<td colspan="2">/</td>
<td colspan="3">R134A</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Ambient Temp.</td>
<td colspan="5">15~35℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Curve Programming</td>
<td>Fixed value</td>
<td colspan="2">Fixed and multi-stage</td>
<td>Fixed value</td>
<td>Fixed and multi-stage</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Internal Material</td>
<td colspan="5">304 stainless steel</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Consumption</td>
<td colspan="3">850W</td>
<td colspan="2">1000W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power Supply</td>
<td colspan="5">AC220V, 50/60Hz(Standard); 110V, 50/60Hz(Optional)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Internal Size(W*D*H)</td>
<td colspan="5">495*505*630mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size(W*D*H)</td>
<td colspan="5">650*785*1135mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Package Size(W*D*H)</td>
<td colspan="5">780*920*1290mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Net Weight</td>
<td colspan="3">120kg</td>
<td colspan="2">145kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td colspan="3">140kg</td>
<td colspan="2">165kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/vertical-type-shaking-incubator/">Vertical Type Shaking Incubator</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Constant Temperature And Humidity Incubator BJPX-HT1000(PC)</title>
		<link>https://keylaser.am/product/constant-temperature-and-humidity-incubator-bjpx-ht1000pc/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 09 Mar 2026 12:18:19 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14453</guid>

					<description><![CDATA[<p><label>Model: </label>BJPX-HT1000(PC)</p>
<p>The constant temperature and humidity incubator has a precise temperature and humidity control system. It provides various environmental simulation conditions required for industrial research and biotechnology testing. Therefore, it can be widely used in sterile tests and stability inspections for textiles, and food processing. As well as testing of raw material properties, product packaging, and product life of industrial products.</p>
<p>The post <a href="https://keylaser.am/product/constant-temperature-and-humidity-incubator-bjpx-ht1000pc/">Constant Temperature And Humidity Incubator BJPX-HT1000(PC)</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. The 7-inch color LCD touch screen can monitor temperature and humidity curves in real-time and query operation history records on one screen.</p>
<p>2. The PID microcomputer-controlled temperature allows fixed-value and segmented operations.  It has a parameter memory function and can resume operation automatically after power-on.</p>
<p>3. There are a built-in steam humidification system and an independent PID humidity control system.</p>
<p>4. Three levels of operation interface permissions(administrator, experimenter, operator) prevent test interruption or equipment malfunction caused by unauthorized operations.</p>
<p>5. The inner liners are made of high-quality stainless steel with a semi-circular and four-corner design.</p>
<p>6. The unique refrigeration system has an automatic defrosting function and a blower for forced convection to make the temperature more uniform.</p>
<p>7. Equipped with an alarm system: high temperature alarm, low water level alarm, independent overheat protection device, and over-current protection.</p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BJPX-HT1000(PC)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Capacity</td>
<td>1000L</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Sensor</td>
<td>PT100</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temp. Range</td>
<td>5~60℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Fluctuation</td>
<td>±2.0℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temp. Uniformity</td>
<td>±2.0℃(@37℃)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Precision</td>
<td>0.1℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Humidity Range</td>
<td>50~95％RH</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Humidity Fluctuation</td>
<td>±5~8%RH</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Humidity Precision</td>
<td>1.0%RH</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Humidification Method</td>
<td>Built-in humidification system</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Refrigerant</td>
<td>R404a</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Heating System</td>
<td>Stainless steel heater</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Timing Range</td>
<td>0~5999min</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Control Type</td>
<td>Microcomputer PID controller</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Display</td>
<td>7.0-inch color LCD touch screen</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Material</td>
<td>External cold-rolled steel with painting; internal stainless steel</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Power Supply</td>
<td>AC220V, 50Hz(Standard); 110V, 60Hz(Optional)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Consumption</td>
<td>1800W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Shelves</td>
<td>2pcs/adjustable</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Standard Accessories</td>
<td>USB port/LAN interface</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Optional Accessories</td>
<td>UV lamp/LED lamp/Printer/Shelves /Automatic water supply system</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Internal Size(W*D*H)</td>
<td>1200*600*1400mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size(W*D*H)</td>
<td>1343*1046*1985mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Package Size(W*D*H)</td>
<td>1420*1070*2150mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Net Weight</td>
<td>227.5kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>300kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/constant-temperature-and-humidity-incubator-bjpx-ht1000pc/">Constant Temperature And Humidity Incubator BJPX-HT1000(PC)</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CO2 Incubator 100L 160L 200L 300L</title>
		<link>https://keylaser.am/product/co2-incubator-100l-160l-200l-300l/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 06 Mar 2026 17:32:56 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14289</guid>

					<description><![CDATA[<p><label>Model: </label>BJPX-C100M, BJPX-C160M, BJPX-C200M, BJPX-C300M</p>
<p>The CO2 incubator simulates the growth environment of cells/tissues in vivo by simulating in the incubator. The incubator requires a stable temperature(37°C), a stable CO2, level(5%), a constant pH(pH: 7.2~7.4), and a high relative saturated humidity(95%). It is a device for cell/tissue culture in vitro.</p>
<p>The post <a href="https://keylaser.am/product/co2-incubator-100l-160l-200l-300l/">CO2 Incubator 100L 160L 200L 300L</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Application:</strong></p>
<p>It is suitable for a wide range of fields such as cytology, biology, oncology, genetics, immunology, virus research and genetic engineering research. It is an ideal device for the cultivation of cells, tissues and bacteria in scientific research units and industrial production departments such as biochemistry and agricultural science.</p>
<p><strong>Features:</strong></p>
<p>1. IR infrared sensor, using dual-channel dual-filter infrared technology.</p>
<p>2. The design of multiple small doors reduces the amount of air exchange between the outside space and the inside of the incubator during the opening process.</p>
<p>3. Inner tank is made of 304 mirror finish stainless steel, featuring a semi-circular corner design for faster and more effective bottom cleaning and sterilization.</p>
<p>4. The design of the 3D airflow channel ensures uniform CO2 distribution, enhancing the accuracy of IR sensor data collection.</p>
<p>5. The interior is heated uniformly by aluminum foil-wrapped silicone heating wires, ensuring rapid temperature increase and excellent uniformity.</p>
<p>6. High quality HEPA filter ensures the inside gas quality.</p>
<p>7. SMC brand solenoid valves ensure more stable gas concentration and less consumption of gas.</p>
<p>8. Equipped with leakage current and over-voltage protectors. Features over-temperature, under-temperature, over-concentration and under-concentration alarms.</p>
<p>9. The water reservoir in the bottom chamber ensures high humidity.</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<colgroup>
<col span="5" /></colgroup>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>BJPX-C100M</td>
<td>BJPX-C160M</td>
<td>BJPX-C200M</td>
<td>BJPX-C300M</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Type</td>
<td colspan="4">Medical series, air jacket</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Sterilization Type</td>
<td colspan="4">90℃ moist heat sterilization</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Capacity</td>
<td>100L</td>
<td>160L</td>
<td>200L</td>
<td>300L</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Sensor</td>
<td colspan="4">PT100</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temp. Range</td>
<td colspan="4">RT＋5~60℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Fluctuation</td>
<td colspan="4">±0.3℃(@37℃)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temp. Uniformity</td>
<td colspan="4">±0.5℃(@37℃)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Precision</td>
<td colspan="4">0.1℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Timing Range</td>
<td colspan="4">0~999h or continuous</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Display</td>
<td colspan="4">7-inch touch screen</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>CO2 Control</td>
<td colspan="4">IR infrared sensor with calibration certificate</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>CO2 Range</td>
<td colspan="4">0~20vol%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>CO2 Uniformity</td>
<td colspan="4">0.2vol%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>CO2 Control Resolution</td>
<td colspan="4">0.1vol%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td rowspan="2">Ambient Temperature and Humidity</td>
<td colspan="4">Ambient Temperature: 5~30℃(Recommendation: 25±2℃)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td colspan="4">Ambient Humidity: ≤80%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Filter</td>
<td colspan="4">CO2 gas filter</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td rowspan="2">Power Supply</td>
<td colspan="4">AC220V, 50/60Hz(Standard); 110V, 50/60Hz(Optional)(External transformer)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td colspan="4">Wiring Method: plug</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Consumption</td>
<td>800W</td>
<td>820W</td>
<td>840W</td>
<td>1800W</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Shelves</td>
<td colspan="2">2pcs, adjustable</td>
<td colspan="2">3pcs, adjustable</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Standard Accessories</td>
<td colspan="4">Shelves, USB interface, CO2 relief valve, CO2 gas filter</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Optional Accessory</td>
<td colspan="4">Water pump</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Internal Size(W*D*H)</td>
<td>407*415*615mm</td>
<td>457*470*753mm</td>
<td>505*470*857mm</td>
<td>567*500*1068mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size(W*D*H)</td>
<td>632*740*894mm</td>
<td>682*796*1030mm</td>
<td>730*796*1134mm</td>
<td>792*830*1344mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Package Size(W*D*H)</td>
<td>757*865*1055mm</td>
<td>807*921*1190mm</td>
<td>855*921*1294mm</td>
<td>917*955*1504mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Net Weight</td>
<td>95kg</td>
<td>110kg</td>
<td>130kg</td>
<td>185kg</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>120kg</td>
<td>135kg</td>
<td>155kg</td>
<td>210kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/co2-incubator-100l-160l-200l-300l/">CO2 Incubator 100L 160L 200L 300L</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
