<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>PCR Analyzer and Pretreatment Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-tag/pcr-analyzer-and-pretreatment/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-tag/pcr-analyzer-and-pretreatment/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Thu, 20 Mar 2025 18:53:47 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>PCR Analyzer and Pretreatment Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-tag/pcr-analyzer-and-pretreatment/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Real-time Fluorescence Quantitative PCR Detection System, RFQ16 Series</title>
		<link>https://keylaser.am/product/real-time-fluorescence-quantitative-pcr-detection-system-rfq16-series/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 20 Mar 2025 18:53:47 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=13623</guid>

					<description><![CDATA[<p><strong>Model : PCR-RFQ161; PCR-RFQ164</strong></p>
<div>
Sample Capacity : 16×0.2ml (2×8well, dual block)<br />
MAX. Ramp Rate : 6℃/s; 8℃/s<br />
Reaction Volume : 15-100μL</p>
<div>Sizes (W×D×H)(mm) : 300×267×198<br />
Compact and precise, the Real-time PCR System is designed to meet your lab's basic testing needs.</div>
</div>
<p>The post <a href="https://keylaser.am/product/real-time-fluorescence-quantitative-pcr-detection-system-rfq16-series/">Real-time Fluorescence Quantitative PCR Detection System, RFQ16 Series</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>This is a portable real-time quantitative PCR, incorporating several advanced technologies, with a dual-channel, dual 8-well module, which can run two different files simultaneously. win10 operating system with the analysis software, without a computer needing to complete the quantitative analysis and print reports.</p>
<h2><strong>Real-time Fluorescence Quantitative PCR Detection System Specifications:</strong></h2>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="714">
<thead>
<tr class="firstRow">
<th width="">Model</th>
<th width="">PCR-RFQ161</th>
<th width="">PCR-RFQ164</th>
</tr>
</thead>
<tbody>
<tr>
<td width="218">Sample Capacity</td>
<td colspan="2" width="395.33333333333337">16×0.2ml (2×8well, dual block)</td>
</tr>
<tr>
<td width="218">Consumable</td>
<td colspan="2" width="395.33333333333337">Clear 0.2 ml PCR tube /8-tube strips</td>
</tr>
<tr>
<td width="218">Reaction Volume</td>
<td colspan="2" width="395.33333333333337">15-100μL</td>
</tr>
<tr>
<td width="218">Temperature Control Technology</td>
<td colspan="2" width="395.33333333333337">Marlow customized peltier allow 1000000 cycles</td>
</tr>
<tr>
<td width="218">Temperature Range</td>
<td colspan="2" width="395.33333333333337">0-100℃ (Resolution: 0.1℃)</td>
</tr>
<tr>
<td width="218">MAX. Ramp Rate</td>
<td width="218">6℃/s</td>
<td width="218">8℃/s</td>
</tr>
<tr>
<td width="218">Temperature Fluctuation</td>
<td colspan="2" width="395.33333333333337">±0.1℃</td>
</tr>
<tr>
<td width="218">Uniformity</td>
<td colspan="2" width="395.33333333333337">±0.25℃</td>
</tr>
<tr>
<td width="218">Accuracy</td>
<td colspan="2" width="395.33333333333337">±0.25℃</td>
</tr>
<tr>
<td width="218">Hot Lid Temperature</td>
<td colspan="2" width="395.33333333333337">30-110℃ (Adjustable, default 105℃)</td>
</tr>
<tr>
<td width="218">Temperature Control</td>
<td colspan="2" width="395.33333333333337">Block/Tube</td>
</tr>
<tr>
<td width="218">Excitation Wavelength</td>
<td colspan="2" rowspan="1" width="395.33333333333337">300-800nm</td>
</tr>
<tr>
<td width="218">Emission Wavelength</td>
<td colspan="2" rowspan="1" width="395.33333333333337">500-800nm</td>
</tr>
<tr>
<td width="218">Factory Calibrated Dyes</td>
<td colspan="2" rowspan="1" width="395.33333333333337">F1: FAM/SYBR Green I</p>
<p>F2: HEX/VIC/JOE/TET</p>
<p>F3: ROX</p>
<p>F4: CY5</td>
</tr>
<tr>
<td width="218">Excitation</td>
<td colspan="2" width="395.33333333333337">Long life LED</td>
</tr>
<tr>
<td width="218">Detection</td>
<td colspan="2" width="395.33333333333337">High sensitivity photoelectric detector</td>
</tr>
<tr>
<td width="218">Dynamic Range</td>
<td colspan="2" width="395.33333333333337">1-10<sup>10</sup> Copies</td>
</tr>
<tr>
<td width="218">Sensitivity</td>
<td colspan="2" width="395.33333333333337">1 copy</td>
</tr>
<tr>
<td width="218">Feature Function</td>
<td colspan="2" width="395.33333333333337">Quantitative/Qualitative analysis, Melting curve, Genotyping</td>
</tr>
<tr>
<td width="218">Date Export Formats</td>
<td colspan="2" width="395.33333333333337">Excel, csv, txt</td>
</tr>
<tr>
<td width="218">Printing</td>
<td colspan="2" width="395.33333333333337">Report can be printed (optional USB thermal printer)</td>
</tr>
<tr>
<td width="218">Control Method</td>
<td colspan="2" width="395.33333333333337">7 inch color TFT touch screen, Can be connected to computer control</td>
</tr>
<tr>
<td width="218">Communication</td>
<td colspan="2" width="395.33333333333337">USB2.0</td>
</tr>
<tr>
<td width="218">Power Supply</td>
<td colspan="2" width="395.33333333333337">AC220V, 50Hz</td>
</tr>
<tr>
<td width="218">Power</td>
<td colspan="2" width="395.33333333333337">DC15V, 255W</td>
</tr>
<tr>
<td width="218">Size(W×D×H)(mm)</td>
<td colspan="2" width="395.33333333333337">300×267×198</td>
</tr>
<tr>
<td width="218">Shipping Size(W×D×H)(mm)</td>
<td colspan="2" width="395.33333333333337">500×420×350</td>
</tr>
<tr>
<td width="218">N.W./G.W. (kg)</td>
<td colspan="2" width="395.33333333333337">8.5/13</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>&nbsp;</p>
<h2><strong>Real-time Fluorescence Quantitative PCR Detection System Features:</strong></h2>
<p>&nbsp;</p>
<p>&nbsp;</p>
<ol class=" list-paddingleft-2">
<li>The temperature control accuracy is ±0.1℃, ensuring the temperature stability of the reaction system and providing highly accurate experimental results.</li>
<li>The temperature uniformity reaches ±0.25℃, ensuring that the samples in the experiment are uniformly heated throughout the reaction process. The temperature range of the hot cover is adjustable, which can meet the needs of different experimental conditions and guarantee the experiment&#8217;s reliability.</li>
<li>The high sensitivity photoelectric sensor and the kinetic range of 1-10^10 parts make the product capable of reliable detection in multiple concentration ranges.</li>
<li>Supports block and tube mode temperature control to adapt to different experimental needs and provide more flexible operation options.</li>
<li>It can detect single-copy genes and is suitable for various experimental scenarios, providing users with more comprehensive gene detection and analysis.</li>
<li>Provide quantitative/qualitative melting curves, genotyping, and other software analysis functions to meet the user&#8217;s needs for various experimental results.</li>
<li>Directly printable report, optional USB thermal printer, convenient for users to record and share the experimental results.</li>
<li>7-inch color touchscreen and computer connection control can be achieved through a WIFI or USB 2.0 interface, making the operation more flexible and convenient.</li>
<li>Powerful software analysis function for quantitative analysis, melting curve analysis, genotyping and so on.</li>
<li>20G flash memory can save 40000 experimental data.</li>
</ol>
<p>&nbsp;</p>
<h2><strong>Details of Real-Time PCR System:</strong></h2>
<figure id="attachment_13629" aria-describedby="caption-attachment-13629" style="width: 1024px" class="wp-caption alignnone"><img fetchpriority="high" decoding="async" class="wp-image-13629 size-large" src="https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-1024x461.webp" alt="Real-time Fluorescence Quantitative PCR Detection System, RFQ16 Series" width="1024" height="461" srcset="https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-1024x461.webp 1024w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-300x135.webp 300w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-768x346.webp 768w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-1536x691.webp 1536w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-2048x922.webp 2048w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-600x270.webp 600w" sizes="(max-width: 1024px) 100vw, 1024px" /><figcaption id="caption-attachment-13629" class="wp-caption-text">Equipped with high resolution touch screen</figcaption></figure>
<figure id="attachment_13628" aria-describedby="caption-attachment-13628" style="width: 1024px" class="wp-caption alignnone"><img decoding="async" class="wp-image-13628 size-large" src="https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-5-1024x696.webp" alt="Real-time Fluorescence Quantitative PCR Detection System, RFQ16 Series" width="1024" height="696" srcset="https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-5-1024x696.webp 1024w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-5-300x204.webp 300w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-5-768x522.webp 768w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-5-1536x1044.webp 1536w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-5-2048x1392.webp 2048w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-5-600x408.webp 600w" sizes="(max-width: 1024px) 100vw, 1024px" /><figcaption id="caption-attachment-13628" class="wp-caption-text">The heat dissipation holes are reasonably designed to effectively ensure the temperature control of the device during long time operation. The power socket and switch are centralized underneath the device for easy operation.</figcaption></figure>
<figure id="attachment_13627" aria-describedby="caption-attachment-13627" style="width: 1024px" class="wp-caption alignnone"><img decoding="async" class="wp-image-13627 size-large" src="https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-4-1024x879.webp" alt="Real-time Fluorescence Quantitative PCR Detection System, RFQ16 Series" width="1024" height="879" srcset="https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-4-1024x879.webp 1024w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-4-300x257.webp 300w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-4-768x659.webp 768w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-4-1536x1318.webp 1536w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-4-2048x1757.webp 2048w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-4-600x515.webp 600w" sizes="(max-width: 1024px) 100vw, 1024px" /><figcaption id="caption-attachment-13627" class="wp-caption-text">A temperature control module surrounds the sample plate tray, ensuring that each sample is heated evenly during amplification.</figcaption></figure>
<figure id="attachment_13626" aria-describedby="caption-attachment-13626" style="width: 1024px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-13626 size-large" src="https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-3-1024x1009.webp" alt="Real-time Fluorescence Quantitative PCR Detection System, RFQ16 Series" width="1024" height="1009" srcset="https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-3-1024x1009.webp 1024w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-3-300x295.webp 300w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-3-768x756.webp 768w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-3-1536x1513.webp 1536w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-3-600x591.webp 600w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-3-100x100.webp 100w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-3.webp 1864w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /><figcaption id="caption-attachment-13626" class="wp-caption-text">Real-time Fluorescence Quantitative PCR Detection System, RFQ16 Series</figcaption></figure>
<figure id="attachment_13625" aria-describedby="caption-attachment-13625" style="width: 1024px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-13625 size-large" src="https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-2-1024x461.webp" alt="Real-time Fluorescence Quantitative PCR Detection System, RFQ16 Series" width="1024" height="461" srcset="https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-2-1024x461.webp 1024w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-2-300x135.webp 300w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-2-768x346.webp 768w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-2-1536x691.webp 1536w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-2-2048x922.webp 2048w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-2-600x270.webp 600w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /><figcaption id="caption-attachment-13625" class="wp-caption-text">Real-time Fluorescence Quantitative PCR Detection System, RFQ16 Series</figcaption></figure>
<figure id="attachment_13624" aria-describedby="caption-attachment-13624" style="width: 1024px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-13624 size-large" src="https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-1-1024x776.webp" alt="Real-time Fluorescence Quantitative PCR Detection System, RFQ16 Series" width="1024" height="776" srcset="https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-1-1024x776.webp 1024w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-1-300x227.webp 300w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-1-768x582.webp 768w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-1-1536x1165.webp 1536w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-1-2048x1553.webp 2048w, https://keylaser.am/wp-content/uploads/2025/03/PCR-RFQ161-1-600x455.webp 600w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /><figcaption id="caption-attachment-13624" class="wp-caption-text">Real-time Fluorescence Quantitative PCR Detection System, RFQ16 Series</figcaption></figure>
<p>The post <a href="https://keylaser.am/product/real-time-fluorescence-quantitative-pcr-detection-system-rfq16-series/">Real-time Fluorescence Quantitative PCR Detection System, RFQ16 Series</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hybridization Instrument</title>
		<link>https://keylaser.am/product/hybridization-instrument/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 20 Mar 2025 18:47:22 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=13619</guid>

					<description><![CDATA[<p><strong>Model : HYI-2000</strong></p>
<p>Temp. Control Range : RT+5~100 ℃<br />
Temp. Accuracy : ≤ ± 1℃<br />
Heating Time : ≤2min (From 37℃ to 95℃)<br />
Cooling Time : ≤6min (From 95℃ to 45℃)<br />
Size(W×D×H)(mm)(Without the Heating Block) : 440x220x120</p>
<div>From the detection of RNA and DNA to the study of proteins, this hybridization instrument offers you a variety of application scenarios to meet the needs of different experiments.</div>
<p>The post <a href="https://keylaser.am/product/hybridization-instrument/">Hybridization Instrument</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The hybridization instrument features a variety of hybridization modes and temperature control options for different types of nucleic acid hybridization experiments. From RNA and DNA detection to protein research, the hybridization instrument offers a wide range of application scenarios to meet the needs of different experiments. It has a simple and intuitive user interface with an intelligent control system that makes setting the temperature, time, and hybridization mode easy. Pre-programmed and programmable options allow you to ensure efficient and smooth experiments.</p>
<h2><strong>Hybridization Instrument Specifications:</strong></h2>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="491">
<thead>
<tr class="firstRow">
<th width="237.33333333333334">Model</th>
<th width="211.33333333333334">HYI-2000</th>
</tr>
</thead>
<tbody>
<tr>
<td width="237.33333333333334">Temp. Control Range</td>
<td width="211.33333333333334">RT+5~100 ℃</td>
</tr>
<tr>
<td width="237.33333333333334">Temp. Setting Range</td>
<td width="211.33333333333334">0℃~100℃</td>
</tr>
<tr>
<td width="237.33333333333334">Time Range</td>
<td width="211.33333333333334">1min ~ 99h 59min</td>
</tr>
<tr>
<td width="237.33333333333334">Temp. Accuracy</td>
<td width="211.33333333333334">≤ ± 1℃</td>
</tr>
<tr>
<td width="237.33333333333334">Temp. Uniformity</td>
<td width="211.33333333333334">≤ ± 1℃</td>
</tr>
<tr>
<td width="237.33333333333334">Heating Time</td>
<td width="211.33333333333334">≤2min (From 37℃ to 95℃)</td>
</tr>
<tr>
<td width="237.33333333333334">Cooling Time</td>
<td width="211.33333333333334">≤6min (From 95℃ to 45℃)</td>
</tr>
<tr>
<td width="237.33333333333334">Capacity</td>
<td width="211.33333333333334">12 Slides</td>
</tr>
<tr>
<td width="237.33333333333334">Consumption</td>
<td width="211.33333333333334">350W</td>
</tr>
<tr>
<td width="237.33333333333334">Power Supply</td>
<td width="211.33333333333334">AC220/110V, 50/60Hz</td>
</tr>
<tr>
<td width="237.33333333333334">Size (W×D×H)(mm)(Without the Heating Block)</td>
<td width="211.33333333333334">440x220x120</td>
</tr>
<tr>
<td width="237.33333333333334">Shipping Size (W×D×H)(mm)</td>
<td width="211.33333333333334">600x410x320</td>
</tr>
<tr>
<td width="237.33333333333334">N.W./G.W. (kg)</td>
<td width="211.33333333333334">4.5/7</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>&nbsp;</p>
<h2><strong>Hybridization Instrument Feature:</strong></h2>
<ol class=" list-paddingleft-2">
<li>Hybridisation instrument allows the reaction time to be set, eliminating the need for manual adjustments.</li>
<li>Constant temperature ensures that a constant temperature is maintained throughout the reaction, eliminating the need for frequent adjustments and improving operational convenience.</li>
<li>The FISH processing step reduces the manual operation time, improving operation efficiency and experimental precision.</li>
<li>Touch screen makes the operation more convenient.</li>
<li>Power failure protection function supports automatic backup and operation after power recovery.</li>
<li>Automatic cooling, automatic warm-up and other functions greatly improve the convenience of operation.</li>
<li>Support 105 sets of data storage, easy to view and compare data.</li>
<li>High-temperature control accuracy and low fluctuation</li>
</ol>
<p>The post <a href="https://keylaser.am/product/hybridization-instrument/">Hybridization Instrument</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
