<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Freeze Dryer Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-category/scientz/freeze-dryer-2/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-category/scientz/freeze-dryer-2/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Wed, 08 Jul 2026 08:45:52 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.5</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>Freeze Dryer Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-category/scientz/freeze-dryer-2/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>SCIENTZ-10ND 12ND 18ND Electrical Heating LCD Display Freeze Dryer</title>
		<link>https://keylaser.am/product/scientz-10nd-12nd-18nd-electrical-heating-lcd-display-freeze-dryer/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Wed, 08 Jul 2026 08:45:52 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=16847</guid>

					<description><![CDATA[<p>Scientz-10NDElectric Heating Freeze-Drying Machine Scientz-10ND Ordinary Top-Press OrdinaryMulti-Manifolds Top-PressMulti-Manifolds No-load Temperature &#60;-56℃ &#60;-56℃ &#60;-56℃ &#60;-56℃ Temperature range -56℃-50℃ -56℃-50℃ -56℃-50℃ -56℃-50℃ Freeze Area 0.12 m2 0.076 m2 0.12 m2 0.076 m2 Plate Load Capacity 1.5 L 1 L 1.5 L 1 L Ability to Capture Water 3Kg 3 Kg 3 Kg 3 Kg Vacuum Degree &#60;10Pa &#60;10Pa &#60;10Pa &#60;10Pa Machine Dimension W450×D580×H(380+450) mm W450×D580×H(380+450) mm W450×D580×H(380+450) mm [&#8230;]</p>
<p>The post <a href="https://keylaser.am/product/scientz-10nd-12nd-18nd-electrical-heating-lcd-display-freeze-dryer/">SCIENTZ-10ND 12ND 18ND Electrical Heating LCD Display Freeze Dryer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Scientz-10N</strong><strong>D</strong><strong>E</strong><strong>le</strong><strong>ctric </strong><strong>H</strong><strong>eating </strong><strong>F</strong><strong>reeze</strong><strong>-D</strong><strong>rying </strong><strong>M</strong><strong>achine</strong></p>
<div class="table-responsive">
<table>
<tbody>
<tr class="firstRow">
<td><strong>Scientz-10ND</strong></td>
<td><strong>Ordinary</strong></td>
<td><strong>Top-Press</strong></td>
<td><strong>Ordinary</strong><strong>Multi-Manifolds</strong></td>
<td><strong>Top-Press</strong><strong>Multi-Manifolds</strong></td>
</tr>
<tr>
<td><strong>No-load Temperature</strong></td>
<td>&lt;-56℃</td>
<td>&lt;-56℃</td>
<td>&lt;-56℃</td>
<td>&lt;-56℃</td>
</tr>
<tr>
<td><strong>Temperature range</strong></td>
<td>-56℃-50℃</td>
<td>-56℃-50℃</td>
<td>-56℃-50℃</td>
<td>-56℃-50℃</td>
</tr>
<tr>
<td><strong>Freeze Area</strong></td>
<td>0.12 m<sup>2</sup></td>
<td>0.076 m<sup>2</sup></td>
<td>0.12 m<sup>2</sup></td>
<td>0.076 m<sup>2</sup></td>
</tr>
<tr>
<td><strong>Plate Load Capacity</strong></td>
<td>1.5 L</td>
<td>1 L</td>
<td>1.5 L</td>
<td>1 L</td>
</tr>
<tr>
<td><strong>Ability to Capture Water</strong></td>
<td>3Kg</td>
<td>3 Kg</td>
<td>3 Kg</td>
<td>3 Kg</td>
</tr>
<tr>
<td><strong>Vacuum Degree</strong></td>
<td>&lt;10Pa</td>
<td>&lt;10Pa</td>
<td>&lt;10Pa</td>
<td>&lt;10Pa</td>
</tr>
<tr>
<td><strong>Machine Dimension</strong></td>
<td>W450×D580×H(380+450) mm</td>
<td>W450×D580×H(380+450) mm</td>
<td>W450×D580×H(380+450) mm</td>
<td>W450×D580×H(380+450) mm</td>
</tr>
<tr>
<td><strong>Sample Tray Size</strong></td>
<td>4×Φ200mm</td>
<td>Ø 3×180 mm</td>
<td>4×Φ200mm</td>
<td>Ø 3×180 mm</td>
</tr>
<tr>
<td><strong>Power</strong></td>
<td>950W</td>
<td>950W</td>
<td>950W</td>
<td>950W</td>
</tr>
<tr>
<td><strong>Power Supply</strong></td>
<td>110V/60Hz or 220V/50Hz</td>
<td>110V/60Hz or 220V/50Hz</td>
<td>110V/60Hz or 220V/50Hz</td>
<td>110V/60Hz or 220V/50Hz</td>
</tr>
<tr>
<td><strong>interlayer spacing</strong></td>
<td>70 mm</td>
<td>70 mm</td>
<td>70 mm</td>
<td>70 mm</td>
</tr>
<tr>
<td><strong>Cold trap size</strong></td>
<td>Ø215×160 mm</td>
<td>Ø215×160 mm</td>
<td>Ø215×160 mm</td>
<td>Ø215×160 mm</td>
</tr>
<tr>
<td rowspan="3"><strong>The number</strong><strong> of </strong><strong>Schering bottles</strong></td>
<td>Ø22: 260</td>
<td>Ø22: 165</td>
<td>Ø22: 260</td>
<td>Ø22: 165</td>
</tr>
<tr>
<td>Ø16: 480</td>
<td>Ø16: 285</td>
<td>Ø16: 480</td>
<td>Ø16: 285</td>
</tr>
<tr>
<td>Ø12: 920</td>
<td>Ø12: 560</td>
<td>Ø12: 920</td>
<td>Ø12: 560</td>
</tr>
<tr>
<td><strong>N.W./ G.W</strong></td>
<td><strong>90KG/ 105KG</strong></td>
<td><strong>95KG/110KG</strong></td>
<td><strong>105KG/120KG</strong></td>
<td><strong>110KG/125KG</strong></td>
</tr>
</tbody>
</table>
</div>
<p><strong>Scientz-1</strong><strong>2</strong><strong>N</strong><strong>D </strong><strong>E</strong><strong>le</strong><strong>ctric </strong><strong>H</strong><strong>eating </strong><strong>F</strong><strong>reeze</strong><strong>-D</strong><strong>rying </strong><strong>M</strong><strong>achine</strong></p>
<div class="table-responsive">
<table>
<tbody>
<tr class="firstRow">
<td><strong>Scientz-12ND</strong></td>
<td><strong>Ordinary</strong></td>
<td><strong>Top-Press</strong></td>
<td><strong>Ordinary</strong><strong>Multi-Manifolds</strong></td>
<td><strong>Top-Press</strong><strong>Multi-Manifolds</strong></td>
</tr>
<tr>
<td><strong>No-load Temperature</strong></td>
<td>&lt;-56℃</td>
<td>&lt;-56℃</td>
<td>&lt;-56℃</td>
<td>&lt;-56℃</td>
</tr>
<tr>
<td><strong>Temperature range</strong></td>
<td>-56℃-50℃</td>
<td>-56℃-50℃</td>
<td>-56℃-50℃</td>
<td>-56℃-50℃</td>
</tr>
<tr>
<td><strong>Freeze Area</strong></td>
<td>0.12 m<sup>2</sup></td>
<td>0.076 m<sup>2</sup></td>
<td>0.12 m<sup>2</sup></td>
<td>0.076 m<sup>2</sup></td>
</tr>
<tr>
<td><strong>Plate Load Capacity</strong></td>
<td>1.5 L</td>
<td>1 L</td>
<td>1.5 L</td>
<td>1 L</td>
</tr>
<tr>
<td><strong>Ability to Capture Water</strong></td>
<td>4Kg</td>
<td>4Kg</td>
<td>4Kg</td>
<td>4Kg</td>
</tr>
<tr>
<td><strong>Vacuum Degree</strong></td>
<td>&lt;10Pa</td>
<td>&lt;10Pa</td>
<td>&lt;10Pa</td>
<td>&lt;10Pa</td>
</tr>
<tr>
<td><strong>Machine Dimension</strong></td>
<td>W600×D460×H(730+450) mm</td>
<td>W600×D460×H(730+450) mm</td>
<td>W600×D460×H(730+450) mm</td>
<td>W600×D460×H(730+450) mm</td>
</tr>
<tr>
<td><strong>Sample Tray Size</strong></td>
<td>4×Φ200mm</td>
<td>Ø 3×180 mm</td>
<td>4×Φ200mm</td>
<td>Ø 3×180 mm</td>
</tr>
<tr>
<td><strong>Power</strong></td>
<td>950W</td>
<td>950W</td>
<td>950W</td>
<td>950W</td>
</tr>
<tr>
<td><strong>Power Supply</strong></td>
<td>110V/60Hz or 220V/50Hz</td>
<td>110V/60Hz or 220V/50Hz</td>
<td>110V/60Hz or 220V/50Hz</td>
<td>110V/60Hz or 220V/50Hz</td>
</tr>
<tr>
<td><strong>interlayer spacing</strong></td>
<td>70 mm</td>
<td>70 mm</td>
<td>70 mm</td>
<td>70 mm</td>
</tr>
<tr>
<td><strong>Cold trap size</strong></td>
<td>Ø215×160 mm</td>
<td>Ø215×160 mm</td>
<td>Ø215×216 mm</td>
<td>Ø215×216 mm</td>
</tr>
<tr>
<td rowspan="3"><strong>The number</strong><strong> of </strong><strong>Schering bottles</strong></td>
<td>Ø22: 260</td>
<td>Ø22: 165</td>
<td>Ø22: 260</td>
<td>Ø22: 165</td>
</tr>
<tr>
<td>Ø16: 480</td>
<td>Ø16: 285</td>
<td>Ø16: 480</td>
<td>Ø16: 285</td>
</tr>
<tr>
<td>Ø12: 920</td>
<td>Ø12: 560</td>
<td>Ø12: 920</td>
<td>Ø12: 560</td>
</tr>
<tr>
<td><strong>N.W./ G.W</strong></td>
<td><strong>120KG/135KG</strong></td>
<td><strong>125KG/140KG</strong></td>
<td><strong>135KG/150KG</strong></td>
<td><strong>140KG/155KG</strong></td>
</tr>
</tbody>
</table>
</div>
<p><strong>Scientz-1</strong><strong>8</strong><strong>N</strong><strong>D </strong><strong>E</strong><strong>le</strong><strong>ctric </strong><strong>H</strong><strong>eating </strong><strong>F</strong><strong>reeze</strong><strong>-D</strong><strong>rying </strong><strong>M</strong><strong>achine</strong></p>
<div class="table-responsive">
<table>
<tbody>
<tr class="firstRow">
<td><strong>Scientz-18ND</strong></td>
<td><strong>Ordinary</strong></td>
<td><strong>Top-Press</strong></td>
<td><strong>Ordinary</strong><strong>Multi-Manifolds</strong></td>
<td><strong>Top-Press</strong><strong>Multi-Manifolds</strong></td>
</tr>
<tr>
<td><strong>No-load Temperature</strong></td>
<td>&lt;-56℃</td>
<td>&lt;-56℃</td>
<td>&lt;-56℃</td>
<td>&lt;-56℃</td>
</tr>
<tr>
<td><strong>Temperature range</strong></td>
<td>-56℃-50℃</td>
<td>-56℃-50℃</td>
<td>-56℃-50℃</td>
<td>-56℃-50℃</td>
</tr>
<tr>
<td><strong>Freeze Area</strong></td>
<td>0.18 m<sup>2</sup></td>
<td>0.09 m<sup>2</sup></td>
<td>0.18 m<sup>2</sup></td>
<td>0.09 m<sup>2</sup></td>
</tr>
<tr>
<td><strong>Plate Load Capacity</strong></td>
<td>2 L</td>
<td>1 L</td>
<td>2 L</td>
<td>1 L</td>
</tr>
<tr>
<td><strong>Ability to Capture Water</strong></td>
<td>6Kg</td>
<td>6Kg</td>
<td>6Kg</td>
<td>6Kg</td>
</tr>
<tr>
<td><strong>Vacuum Degree</strong></td>
<td>&lt;10Pa</td>
<td>&lt;10Pa</td>
<td>&lt;10Pa</td>
<td>&lt;10Pa</td>
</tr>
<tr>
<td><strong>Machine Dimension</strong></td>
<td>W700×D560×H(960+450) mm</td>
<td>W700×D560×H(960+450) mm</td>
<td>W700×D560×H(960+450) mm</td>
<td>W700×D560×H(960+450) mm</td>
</tr>
<tr>
<td><strong>Sample Tray Size</strong></td>
<td>4×Φ240mm</td>
<td>Ø 3×200 mm</td>
<td>4×Φ240mm</td>
<td>Ø 3×200 mm</td>
</tr>
<tr>
<td><strong>Power</strong></td>
<td>1300W</td>
<td>1300W</td>
<td>1300W</td>
<td>1300W</td>
</tr>
<tr>
<td><strong>Power Supply</strong></td>
<td>110V/60Hz or 220V/50Hz</td>
<td>110V/60Hz or 220V/50Hz</td>
<td>110V/60Hz or 220V/50Hz</td>
<td>110V/60Hz or 220V/50Hz</td>
</tr>
<tr>
<td><strong>interlayer spacing</strong></td>
<td>70 mm</td>
<td>70 mm</td>
<td>70 mm</td>
<td>70 mm</td>
</tr>
<tr>
<td><strong>Cold trap size</strong></td>
<td>Ø270×410 mm</td>
<td>Ø270×410 mm</td>
<td>Ø270×410 mm</td>
<td>Ø270×410 mm</td>
</tr>
<tr>
<td rowspan="3"><strong>The number</strong><strong> of </strong><strong>Schering bottles</strong></td>
<td>Ø22: 360</td>
<td>Ø22: 270</td>
<td>Ø22: 360</td>
<td>Ø22: 270</td>
</tr>
<tr>
<td>Ø16: 740</td>
<td>Ø16: 560</td>
<td>Ø16: 740</td>
<td>Ø16: 560</td>
</tr>
<tr>
<td>Ø12: 1320</td>
<td>Ø12: 990</td>
<td>Ø12: 1320</td>
<td>Ø12: 990</td>
</tr>
<tr>
<td><strong>N.W./ G.W</strong></td>
<td><strong>130KG/145KG</strong></td>
<td><strong>135KG/150KG</strong></td>
<td><strong>145KG/160KG</strong></td>
<td><strong>150KG/165KG</strong></td>
</tr>
</tbody>
</table>
</div>
<p><img decoding="async" title="300764528ec45b3aedee572c3b2fb165.jpg" src="https://www.scientzbio.com/Content/upload/2017213197/201707211521252381274.jpg" alt="product-1-1" /></p>
<p><img decoding="async" title="77e31feecf47441fb40e797c83cd8083.jpg" src="https://www.scientzbio.com/Content/upload/2017213197/201707211521266051850.jpg" alt="product-1-1" /></p>
<p><img decoding="async" title="3a16eb18dc5fbfa057a8301284f384df.jpg" src="https://www.scientzbio.com/Content/upload/2017213197/201707211521262195009.jpg" alt="product-1-1" /></p>
<p><img decoding="async" title="326bad26cbcf1c620ba7673b52db243e.jpg" src="https://www.scientzbio.com/Content/upload/2017213197/201707211521282136278.jpg" alt="product-1-1" /></p>
<p>The post <a href="https://keylaser.am/product/scientz-10nd-12nd-18nd-electrical-heating-lcd-display-freeze-dryer/">SCIENTZ-10ND 12ND 18ND Electrical Heating LCD Display Freeze Dryer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SCIENTZ-1LS Vacuum Centrifugal Concentrator</title>
		<link>https://keylaser.am/product/scientz-1ls-vacuum-centrifugal-concentrator/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Wed, 08 Jul 2026 08:44:14 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=16843</guid>

					<description><![CDATA[<p>SCIENTZ-1LS Vacuum centrifugal concentrator Spec Equipped with rotary frozen device, namely Scientz - 10LS centrifugal concentration meter, by adopting the combination of centrifugal force, vacuum and accelerate the method to make samples of solvent evaporation, so, reach the role of...</p>
<p>The post <a href="https://keylaser.am/product/scientz-1ls-vacuum-centrifugal-concentrator/">SCIENTZ-1LS Vacuum Centrifugal Concentrator</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>SCIENTZ-1LS</strong></p>
<p><strong>Vacuum centrifugal concentrator</strong></p>
<p><strong>Spec</strong></p>
<p>Equipped with rotary frozen device, namely Scientz &#8211; 10LS  centrifugal concentration meter, by adopting the combination of centrifugal force, vacuum and accelerate the method to make samples of solvent evaporation, so, reach the role of concentrated samples.It can be a variety of rotor, can provide large quantities of small volume concentration, which can be widely used in biology, microbiology, biochemistry, pharmaceutical research and analytical chemistry, and many other aspects.Depending on the rotor, the volume of a single sample can be from a few ml and 50 ml;At the same time also to enzyme standard rotor to pack in the enzyme label plate sample for enrichment.Scientz &#8211; more than N series manifold freeze drying machine to precool freeze-dried bottle samples and</p>
<p><strong>Model No:SCIENTZ-1LS</strong></p>
<p>1)Can adjust the speed.</p>
<p>2)The highest seepd  2000 r/min</p>
<p>3)Cold chamber temperateure &lt;-45 ℃ temperature range</p>
<p>4) The device size:640*770*330</p>
<p>5)Weight :50kg</p>
<p>6)Power:2.5kw</p>
<p>7)Total power :2.5kw</p>
<p>8 Power to 220 v + 22 v;50 hz + 10 hz</p>
<p>9)The input power 1500 w</p>
<p>10 Optional rotor type 62 x1. 2 ml and 5 ml / 12 x15ml / 10 ml,</p>
<p>6 x50ml, 2 x96 enzyme standard, 2 x48 hole to hole</p>
<p><img fetchpriority="high" decoding="async" title="product-800-865" src="https://www.scientzbio.com/Content/uploads/2022213197/20220908092834c2c5685f671d40d89622416a1225ee45.png" alt="06-05SCIENTZ-1LS【2】 " width="800" height="865" /></p>
<p>The post <a href="https://keylaser.am/product/scientz-1ls-vacuum-centrifugal-concentrator/">SCIENTZ-1LS Vacuum Centrifugal Concentrator</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>10ND 12ND ,18ND Lyophilization Process Laboratory LCD Display Freeze Dryer</title>
		<link>https://keylaser.am/product/10nd-12nd-18nd-lyophilization-process-laboratory-lcd-display-freeze-dryer/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Wed, 08 Jul 2026 08:42:27 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=16838</guid>

					<description><![CDATA[<p>Features: 1.Prefreeze drying process at in situ situation, high transparent organic glass door to observe working procedure 2.Shelf temperature adjustable, controllable, detectable; its suitable for pilot scale and small production 3. LCD screen display, PID control, drying curve displayed on...</p>
<p>The post <a href="https://keylaser.am/product/10nd-12nd-18nd-lyophilization-process-laboratory-lcd-display-freeze-dryer/">10ND 12ND ,18ND Lyophilization Process Laboratory LCD Display Freeze Dryer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features: </strong></p>
<p>1.Prefreeze drying process at in situ situation, high transparent organic glass door to observe working procedure</p>
<p>2.Shelf temperature adjustable, controllable, detectable; its suitable for pilot scale and small production</p>
<p>3. LCD screen display, PID control, drying curve displayed on the screen</p>
<p>4.Square tray is shape not easily to deformed, easy to operate and clean</p>
<p>5.With Gas charging valve can fill with inert gases like nitrogen gas</p>
<p><strong>Main Technical Parameters: </strong></p>
<div class="table-responsive">
<table class="table" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr class="firstRow">
<td rowspan="7">Drying<br />
chamber</td>
<td>Model</td>
<td rowspan="2">Unit</td>
<td colspan="2">Scientz-10ND<br />
(In-situ)</td>
<td>Scientz-30ND<br />
(In-situ)</td>
<td>Scientz-50ND<br />
(In-situ)</td>
</tr>
<tr>
<td>Specification</td>
<td>Ordinary</td>
<td>Top-Press</td>
<td>Ordinary</td>
<td>Ordinary</td>
</tr>
<tr>
<td>Drying Area</td>
<td>m2</td>
<td>0.2</td>
<td>0.1</td>
<td>0.3</td>
<td>0.6</td>
</tr>
<tr>
<td>No.of Tray</td>
<td>layer</td>
<td>2</td>
<td>1</td>
<td>3</td>
<td>4</td>
</tr>
<tr>
<td>Temp. Range</td>
<td>°C</td>
<td colspan="2">-45~60</td>
<td>-45~60</td>
<td>45~60</td>
</tr>
<tr>
<td>Shelf Gap</td>
<td>mm</td>
<td colspan="2">70</td>
<td>70</td>
<td>70</td>
</tr>
<tr>
<td>Shelf Size</td>
<td>mm</td>
<td colspan="2">240*430*20</td>
<td>240*430*20</td>
<td>350*430*20</td>
</tr>
<tr>
<td rowspan="6">Capture<br />
water<br />
trap</td>
<td>φ22 Penicillin Vial</td>
<td>PC</td>
<td>370</td>
<td>185</td>
<td>546</td>
<td>1056</td>
</tr>
<tr>
<td>φ16 Penicillin Vial</td>
<td>PC</td>
<td>768</td>
<td>384</td>
<td>1080</td>
<td>2046</td>
</tr>
<tr>
<td>φ14 Penicillin Vial</td>
<td>PC</td>
<td>970</td>
<td>485</td>
<td>1452</td>
<td>&nbsp;</td>
</tr>
<tr>
<td>φ12 Penicillin Vial</td>
<td>PC</td>
<td>1300</td>
<td>650</td>
<td>1950</td>
<td>3690</td>
</tr>
<tr>
<td>Temperature</td>
<td>°C</td>
<td colspan="2">≤-55(No-load)</td>
<td>≤-55(No-load)</td>
<td>≤-55(No-load)</td>
</tr>
<tr>
<td>Ability to<br />
Capture Water</td>
<td>Kg/24h</td>
<td>3</td>
<td>1.5</td>
<td>6</td>
<td>10</td>
</tr>
<tr>
<td rowspan="7">Parameters</td>
<td>Power</td>
<td>KW</td>
<td colspan="2">1.0 kw</td>
<td>2.0 kw</td>
<td>3.0 kw</td>
</tr>
<tr>
<td>Power Supply</td>
<td>V/Hz</td>
<td colspan="2">110-115V or 220-240V 50/60Hz</td>
<td>110-115V or 220-240V 50/60Hz</td>
<td>380V/50Hz</td>
</tr>
<tr>
<td>Plate Load<br />
Capacity</td>
<td>L</td>
<td>2</td>
<td>1</td>
<td>3</td>
<td>6</td>
</tr>
<tr>
<td>Electric Defrost</td>
<td>&#8211;</td>
<td colspan="2">/</td>
<td>/</td>
<td>Y</td>
</tr>
<tr>
<td>Vacuum</td>
<td>Pa</td>
<td colspan="2">≤10</td>
<td>≤10</td>
<td>≤10</td>
</tr>
<tr>
<td>Cooling Mode</td>
<td>&#8211;</td>
<td colspan="2">Air cooling: well<br />
ventilated room<br />
temperature ≤25°C</td>
<td>Air cooling: well<br />
ventilated room<br />
temperature ≤25°C</td>
<td>Air cooling: well<br />
ventilated room<br />
temperature ≤25°C</td>
</tr>
<tr>
<td>Dimension</td>
<td>mm</td>
<td colspan="2">820*650*550</td>
<td>630*800*1400</td>
<td>630*800*1400</td>
</tr>
<tr>
<td>Drying<br />
chamber<br />
shape</td>
<td>&nbsp;</td>
<td>&nbsp;</td>
<td colspan="2">cylindrical</td>
<td>cylindrical</td>
<td>cylindrical</td>
</tr>
</tbody>
</table>
</div>
<p><img decoding="async" title="product-1-1" src="https://www.scientzbio.com/Content/upload/2017213197/201707031646368379583.jpg" alt="25_副本.jpg" /></p>
<p>&nbsp;</p>
<p>The post <a href="https://keylaser.am/product/10nd-12nd-18nd-lyophilization-process-laboratory-lcd-display-freeze-dryer/">10ND 12ND ,18ND Lyophilization Process Laboratory LCD Display Freeze Dryer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SCIENTZ-100F Lyophilization Dryer Laboratory LCD Display Freeze Dryer</title>
		<link>https://keylaser.am/product/scientz-100f-lyophilization-dryer-laboratory-lcd-display-freeze-dryer/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Wed, 08 Jul 2026 08:40:44 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=16835</guid>

					<description><![CDATA[<div class="pro-con">Vacuum centrifugal concentrator Spec Equipped with rotary frozen device, namely Scientz - 10LS centrifugal concentration meter, by adopting the combination of centrifugal force, vacuum and accelerate the method to make samples of solvent evaporation, so, reach the role of concentrated samples.It...</div>
<div class="a2a_kit a2a_kit_size_32 a2a_default_style"></div>
<p>The post <a href="https://keylaser.am/product/scientz-100f-lyophilization-dryer-laboratory-lcd-display-freeze-dryer/">SCIENTZ-100F Lyophilization Dryer Laboratory LCD Display Freeze Dryer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Scientz-100F</strong> <strong>Silicone </strong><strong>O</strong><strong>il </strong><strong>H</strong><strong>eating </strong><strong>F</strong><strong>reeze</strong><strong>-D</strong><strong>rying </strong><strong>M</strong><strong>achine</strong></p>
<p>●Pre-freeze drying process at in situ situation, reduce the complicate operation from drying process, become automatically;</p>
<p>● Shelf temperature differences ± 1 ℃, dry effect uniform;</p>
<p>● Intermediate medium circulation technique, shelf can refrigeration, heating, temperature adjustable, controllable, pilot scale test and production process;</p>
<p>● Due to drying chamber and cold trap for fission structure, special gas circuit designed, capture water ability is strong and drying time to be short;</p>
<p>● Embedded touch screen, PLC controlled and PID temperature controlled display lyophilized curve and history curve;</p>
<p>● Control system can be stored 40 freeze-dry process programs, each programcan have 40 temperature settings, and can choose the manual operation and automatic operation, the Top-Press type is equipped with an automatic defrost function;</p>
<p>● Optional eutectic point test device;</p>
<p>● U disk data available;</p>
<p>● Equipped with PC software can print curve, browsing curve, modify data;</p>
<p>●Square tray is shape not easily to deformed, easy to operate and clean;</p>
<p>● Can be configured charging valve, rechargeable dry inert gas.</p>
<p>● Drying chamber adopts high lightcolorless transparent organic glass door, in operation process can be observed clearly the change of material process;</p>
<p>●Refrigeration system using overlap refrigeration technology, low refrigeration temperature, large refrigerating capacity, and adopt imported closed compressor, high efficient and reliable, low noise.</p>
<p><img decoding="async" title="product-1-1" src="https://www.scientzbio.com/Content/upload/2017213197/201707211101058556848.jpg" alt="92f72f3cfeaedb74102e336d359baf66.jpg" /></p>
<p><strong>Technical Parameters</strong></p>
<div class="tabs-cont pro-detail-box">
<div class="tabs-item">
<div class="table-responsive">
<table class="table" border="1" cellspacing="1" cellpadding="1">
<tbody>
<tr class="firstRow">
<td>Drying chamber</td>
<td>Scientz-100F</td>
<td>Ordinary</td>
<td>Top-Press</td>
</tr>
<tr>
<td></td>
<td>DryingArea</td>
<td>1.08 m<sup>2</sup></td>
<td>1.08 m<sup>2</sup></td>
</tr>
<tr>
<td></td>
<td>No.of Tray</td>
<td>4+1 layer</td>
<td>4+1 layer</td>
</tr>
<tr>
<td></td>
<td>Temp. Range</td>
<td>-70～70℃</td>
<td>-70～70℃</td>
</tr>
<tr>
<td></td>
<td>Shelf Gap</td>
<td>70mm</td>
<td>70mm</td>
</tr>
<tr>
<td></td>
<td>Shelf Size</td>
<td>600mm×400mm</td>
<td>600mm×400mm</td>
</tr>
<tr>
<td>Capture water trap</td>
<td>φ22 <strong>Schering bottles</strong></td>
<td>2210</td>
<td>2210</td>
</tr>
<tr>
<td></td>
<td>φ16<strong>Schering bottles</strong></td>
<td>4190</td>
<td>4190</td>
</tr>
<tr>
<td></td>
<td>φ12<strong>Schering bottles</strong></td>
<td>7020</td>
<td>7020</td>
</tr>
<tr>
<td></td>
<td>Temperature</td>
<td>-70℃(No-load)</td>
<td>-70℃(No-load)</td>
</tr>
<tr>
<td></td>
<td>Ability to Capture Water</td>
<td>15Kg/24h</td>
<td>15Kg/24h</td>
</tr>
<tr>
<td>Parameters</td>
<td>Power</td>
<td>6.8 kw</td>
<td>7.4 kw</td>
</tr>
<tr>
<td></td>
<td>Power Supply</td>
<td>380V 50/60Hz</td>
<td>380V 50/60Hz</td>
</tr>
<tr>
<td></td>
<td>Plate Load Capacity</td>
<td>15 L</td>
<td>15 L</td>
</tr>
<tr>
<td></td>
<td>Electric Defrost</td>
<td></td>
<td>√</td>
</tr>
<tr>
<td></td>
<td>Vacuum</td>
<td>&lt;10Pa</td>
<td>&lt;10Pa</td>
</tr>
<tr>
<td></td>
<td>Dimension</td>
<td>1300×1000×1450mm</td>
<td>1500×12001600mm</td>
</tr>
<tr>
<td colspan="2">Drying chamber shape</td>
<td>square</td>
<td>square</td>
</tr>
<tr>
<td colspan="2"><strong>N.W./ G.W</strong></td>
<td><strong>610KG/690KG</strong></td>
<td><strong>780KG/880KG</strong></td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/scientz-100f-lyophilization-dryer-laboratory-lcd-display-freeze-dryer/">SCIENTZ-100F Lyophilization Dryer Laboratory LCD Display Freeze Dryer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SCIENTZ-50F Vacuum Big LCD Display Heating Function Freeze Dryer</title>
		<link>https://keylaser.am/product/scientz-50f-vacuum-big-lcd-display-heating-function-freeze-dryer/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Wed, 08 Jul 2026 08:38:40 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=16832</guid>

					<description><![CDATA[<p>hrysanthemi vacuum freeze dryer 1)Pre-Freeze drying process at in situ situation, reduce the complicate operation from drying process, become automatically;2)Shelf temperature differences ± 1 °C, dry effect uniform; 3)Intermediate medium circulation technique, shelf can refrigeration, heating,...</p>
<p>The post <a href="https://keylaser.am/product/scientz-50f-vacuum-big-lcd-display-heating-function-freeze-dryer/">SCIENTZ-50F Vacuum Big LCD Display Heating Function Freeze Dryer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The lyophilizer originated in the 1920s vacuum freeze-drying technology after decades of ups and downs, and made great progress in the last 20 years. In the 21st century, vacuum freeze-drying technology has become more and more popular with people due to the advantages that other drying methods cannot match. In addition to its wide application in the fields of medicine, biological products, food, blood products and active substances, its application scale and field Still expanding. To this end, vacuum freeze drying is bound to become an important application technology in the 21st century.</p>
<p>Ningbo Scientz Biotechnology specializes in the production of vacuum freeze dryers. There are many experienced professional senior engineers, independent production workshops, strict production according to standards, and careful and detailed factory inspection procedures to ensure the quality of each machine.</p>
<p>1)Pre-Freeze drying process at in situ situation, reduce the complicate operation from drying process, become automatically;2)Shelf temperature differences ± 1 °C, dry effect uniform;</p>
<p>3)Intermediate medium circulation technique, shelf can refrigeration, heating, temperature adjustable, controllable, pilot scale test and production process;</p>
<p>4)Due to drying chamber and cold trap for fission structure, special gas circuit designed, capture water ability is strong and drying time to be short;</p>
<p>5) Embedded touch screen, PLC controlled and PID temperature controlled display lyophilized</p>
<p>curve and history curve;</p>
<p>6)Control system can be stored 40 freeze-dry process programs, each program can have 40 temperature settings, and can choose the manual operation and automatic operation, the Top-Press type is equipped with an automatic defrost function;</p>
<p>7) Optional eutectic point test device;</p>
<p>8) U disk data available;</p>
<p>9) Equipped with PC software can print curve, browsing curve, modify data;</p>
<p>10)Square tray is shape not easily to deformed, easy to operate and clean;</p>
<div class="table-responsive">
<table class="table" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr class="firstRow">
<td rowspan="6">Drying chamber</td>
<td>Scientz-50F</td>
<td>Ordinary</td>
</tr>
<tr>
<td>Drying Area</td>
<td>0.5 m2</td>
</tr>
<tr>
<td>No.of Tray</td>
<td>4+1 layer</td>
</tr>
<tr>
<td>Temp. Range</td>
<td>-70~70 Degree</td>
</tr>
<tr>
<td>Shelf Gap</td>
<td>50 mm</td>
</tr>
<tr>
<td>Shelf Size</td>
<td>450mm×300mm</td>
</tr>
<tr>
<td rowspan="5">Capture water trap</td>
<td>φ22  Schering bottles</td>
<td>1400</td>
</tr>
<tr>
<td>φ16  Schering bottles</td>
<td>2046</td>
</tr>
<tr>
<td>φ12  Schering bottles</td>
<td>3690</td>
</tr>
<tr>
<td>Temperature</td>
<td>-70°C(No-load)</td>
</tr>
<tr>
<td>Ability to Capture Water</td>
<td>10Kg/24h</td>
</tr>
<tr>
<td rowspan="5">Parameters</td>
<td>Power</td>
<td>4.5 kw</td>
</tr>
<tr>
<td>Power Supply</td>
<td>110-115V or 220-240V 50/60Hz</td>
</tr>
<tr>
<td>Plate Load Capacity</td>
<td>6 L</td>
</tr>
<tr>
<td>Electric Defrost</td>
<td>&nbsp;</td>
</tr>
<tr>
<td>Vacuum</td>
<td>&lt;10 Pa</td>
</tr>
</tbody>
</table>
</div>
<p><img decoding="async" title="product-337-446" src="https://www.scientzbio.com/Content/upload/2017213197/201707211059295069763.jpg" alt="QQ图片20170720140008_看图王.jpg" width="337" height="446" /></p>
<p>The post <a href="https://keylaser.am/product/scientz-50f-vacuum-big-lcd-display-heating-function-freeze-dryer/">SCIENTZ-50F Vacuum Big LCD Display Heating Function Freeze Dryer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SCIENTZ-30F Vacuum Function Big LCD Display Heating Function Freeze Dryer</title>
		<link>https://keylaser.am/product/16828/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Wed, 08 Jul 2026 08:35:21 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=16828</guid>

					<description><![CDATA[<p>hrysanthemi vacuum freeze dryer 1)Pre-Freeze drying process at in situ situation, reduce the complicate operation from drying process, become automatically;2)Shelf temperature differences ± 1 °C, dry effect uniform; 3)Intermediate medium circulation technique, shelf can refrigeration, heating,...</p>
<p>The post <a href="https://keylaser.am/product/16828/">SCIENTZ-30F Vacuum Function Big LCD Display Heating Function Freeze Dryer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Scientz-</strong><strong>3</strong><strong>0</strong><strong>F</strong><strong> </strong><strong>Silicone </strong><strong>O</strong><strong>il</strong><strong> </strong><strong>H</strong><strong>eating </strong><strong>F</strong><strong>reeze</strong><strong>-D</strong><strong>rying </strong><strong>M</strong><strong>achine</strong></p>
<p>●Pre-freeze drying process at in situ situation, reduce the complicate operation from drying process, become automatically;</p>
<p>● Shelf temperature differences ± 1 ℃, dry effect uniform;</p>
<p>● Intermediate medium circulation technique, shelf can refrigeration, heating, temperature adjustable, controllable, pilot scale test and production process;</p>
<p>● Due to drying chamber and cold trap for fission structure, special gas circuit designed, capture water ability is strong and drying time to be short;</p>
<p>● Embedded touch screen, PLC controlled and PID temperature controlled display lyophilized curve and history curve;</p>
<p>● Control system can be stored 40 freeze-dry process programs, each program can have 40 temperature settings, and can choose the manual operation and automatic operation, the Top-Press type is equipped with an automatic defrost function;</p>
<p>● Optional eutectic point test device;</p>
<p>● U disk data available;</p>
<p>● Equipped with PC software can print curve, browsing curve, modify data;</p>
<p>●Square tray is shape not easily to deformed, easy to operate and clean;</p>
<p>● Can be configured charging valve, rechargeable dry inert gas.</p>
<p>● Drying chamber adopts high light colorless transparent organic glass door, in operation process can be observed clearly the change of material process;</p>
<p>●Refrigeration system using overlap refrigeration technology, low refrigeration temperature, large refrigerating capacity, and adopt imported closed compressor, high efficient and reliable, low noise.</p>
<div class="table-responsive">
<table>
<tbody>
<tr class="firstRow">
<td rowspan="6">Drying chamber</td>
<td>Scientz-30F</td>
<td>Ordinary</td>
<td>Top-Press</td>
</tr>
<tr>
<td>Drying Area</td>
<td>0.3 m<sup>2</sup></td>
<td>0.3 m<sup>2</sup></td>
</tr>
<tr>
<td>No.of Tray</td>
<td>3+1 layer</td>
<td>3+1 layer</td>
</tr>
<tr>
<td>Temp. Range</td>
<td>-70～70 ℃</td>
<td>-70～70 ℃</td>
</tr>
<tr>
<td>Shelf Gap</td>
<td>50 mm</td>
<td>70 mm</td>
</tr>
<tr>
<td>Shelf Size</td>
<td>400mm×270mm</td>
<td>400mm×270mm</td>
</tr>
<tr>
<td rowspan="5">Capture water trap</td>
<td>φ22  <strong>Schering bottles</strong></td>
<td>540</td>
<td>540</td>
</tr>
<tr>
<td>φ16  <strong>Schering bottles</strong></td>
<td>1080</td>
<td>1080</td>
</tr>
<tr>
<td>φ12  <strong>Schering bottles</strong></td>
<td>1950</td>
<td>1950</td>
</tr>
<tr>
<td>Temperature</td>
<td>-70℃(No-load)</td>
<td>-70℃(No-load)</td>
</tr>
<tr>
<td>Ability to Capture Water</td>
<td>6Kg/24h</td>
<td>6Kg/24h</td>
</tr>
<tr>
<td rowspan="6">Parameters</td>
<td>Power</td>
<td>2.1 kw</td>
<td>2.1kw</td>
</tr>
<tr>
<td>Power Supply</td>
<td>380V 50/60Hz</td>
<td>380/60Hz</td>
</tr>
<tr>
<td>Plate Load Capacity</td>
<td>3 L</td>
<td>3 L</td>
</tr>
<tr>
<td>Electric Defrost</td>
<td></td>
<td>√</td>
</tr>
<tr>
<td>Vacuum</td>
<td>&lt;10 Pa</td>
<td>&lt;10 Pa</td>
</tr>
<tr>
<td>Dimension</td>
<td>630×800×1400 mm</td>
<td>1060×700×1500 mm</td>
</tr>
<tr>
<td colspan="2">Drying chamber shape</td>
<td>square</td>
<td>square</td>
</tr>
<tr>
<td colspan="2"><strong>N.W./ G.W</strong></td>
<td><strong>300KG/ 340KG</strong></td>
<td><strong>360KG/400KG</strong></td>
</tr>
</tbody>
</table>
</div>
<p><img decoding="async" title="图片2.jpg" src="https://www.scientzbio.com/Content/upload/2017213197/201707131428251524582.jpg" alt="product-1-1" /></p>
<p><img decoding="async" title="图片3.jpg" src="https://www.scientzbio.com/Content/upload/2017213197/201707131428252780478.jpg" alt="product-1-1" /></p>
<p>&nbsp;</p>
<p>The post <a href="https://keylaser.am/product/16828/">SCIENTZ-30F Vacuum Function Big LCD Display Heating Function Freeze Dryer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SCIENTZ-18N Lyophilizer Manufacturers Vacuum Function Freeze Dryer</title>
		<link>https://keylaser.am/product/scientz-18n-lyophilizer-manufacturers-vacuum-function-freeze-dryer/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Wed, 08 Jul 2026 08:33:04 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=16823</guid>

					<description><![CDATA[<p>Vacuum centrifugal concentrator Spec Equipped with rotary frozen device, namely Scientz - 10LS centrifugal concentration meter, by adopting the combination of centrifugal force, vacuum and accelerate the method to make samples of solvent evaporation, so, reach the role of concentrated samples.It...</p>
<p>The post <a href="https://keylaser.am/product/scientz-18n-lyophilizer-manufacturers-vacuum-function-freeze-dryer/">SCIENTZ-18N Lyophilizer Manufacturers Vacuum Function Freeze Dryer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Freeze-drying characteristics of vegetables:</strong></p>
<p>1. Cold-dried vegetables retain the nutrients and color, aroma and taste of fresh vegetables to the utmost extent. The drying of freeze-dried vegetables is carried out under low temperature and vacuum conditions, which greatly reduces the loss of some heat sensitive and highly oxidizable substances, and maximizes the preservation of various nutrients in vegetables.</p>
<p>2. freeze-dried fruit does not lose the skeleton structure of the original vegetables, maintaining the original shape of the fruit.</p>
<p>3. rehydration performance is good, closer to the quality of fresh vegetables.</p>
<p>4. There is no surface hardening problem caused by general drying methods.</p>
<p>5. easy to store and transport.</p>
<p><img decoding="async" title="product-816-1043" src="https://www.scientzbio.com/Content/upload/2018213197/201811131357498685580.jpg" alt="product-816-1043" width="816" height="1043" /></p>
<p><strong>Freeze-dried spinach</strong></p>
<p><img decoding="async" title="product-1-1" src="https://www.scientzbio.com/Content/upload/2018213197/201811131355356970287.png" alt="image" /></p>
<p><img decoding="async" title="product-1-1" src="https://www.scientzbio.com/Content/upload/2018213197/201811131356044520334.png" alt="image" /></p>
<p><img decoding="async" title="product-1-1" src="https://www.scientzbio.com/Content/upload/2017213197/201707211013153976956.jpg" alt="scientz-18N压盖型.jpg" /></p>
<p>The post <a href="https://keylaser.am/product/scientz-18n-lyophilizer-manufacturers-vacuum-function-freeze-dryer/">SCIENTZ-18N Lyophilizer Manufacturers Vacuum Function Freeze Dryer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Easy Operation Scientz-N Series Mini Freeze Drying Machine For Sale, Freeze Dryer</title>
		<link>https://keylaser.am/product/easy-operation-scientz-n-series-mini-freeze-drying-machine-for-sale-freeze-dryer/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Tue, 07 Jul 2026 17:43:53 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=16814</guid>

					<description><![CDATA[<div class="pro-con">The characteristics of freeze dryer ● The machine uses international brand Secop ( Danfoss) compressor refrigeration, rapid cooling, cold trap temperature is low. ● 7-inch true color touch LCD screen control system, easy to operate, and powerful. ● Industrial embedded operating system, ARM9 core...</div>
<div class="a2a_kit a2a_kit_size_32 a2a_default_style"></div>
<p>The post <a href="https://keylaser.am/product/easy-operation-scientz-n-series-mini-freeze-drying-machine-for-sale-freeze-dryer/">Easy Operation Scientz-N Series Mini Freeze Drying Machine For Sale, Freeze Dryer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>The characteristics of freeze dryer </strong></p>
<p>● The machine uses international brand Secop ( Danfoss) compressor refrigeration, rapid cooling, cold trap temperature is low.</p>
<p>● 7-inch true color touch LCD screen control system, easy to operate, and powerful.</p>
<p>● Industrial embedded operating system, ARM9 core control circuit design 32M memory 128M FLASH, the operation response speed,</p>
<p><strong>Large amount of stored data.</strong></p>
<p>● The control system automatically saves the freeze-dried data and can be viewed in real-time and historical curves. The entire freeze-drying process is clear.</p>
<p>● dry room color with a colorless transparent injection molding polycarbonate drying room, corrosion-resistant, non-friable, non-adhesive, high transparency, strong sealing, the sample is clear and intuitive, can observe the whole process of freeze-dried.</p>
<p>● Vacuum pump and host connection using the international standard KF quick connector, simple and reliable.</p>
<p>● The machine can store many freeze-drying curve, and use U disk to extract data to the computer, with the host computer software in the computer to browse print and a variety of options.</p>
<p>● equipped with inflatable valve, can be filled with dry inert gas.</p>
<p>● can set the cold trap temperature, lower than the temperature set value to open the vacuum pump to protect the vacuum pump to protect the vacuum pump life.</p>
<p><strong>N series freeze dryer</strong></p>
<p>FREEZE-DRYING SYSTEM</p>
<p>N series freeze-drying machine is compact, with large-scale freeze dryer flexibility, less space, can handle more flexible samples, cost-effective. Suitable for small laboratory, and can choose a variety of configurations:</p>
<p>Common type: suitable for bulk materials, liquid and solid dry</p>
<p>Gland type: suitable for Schering bottled material drying, can achieve sample vacuum pressure package. Contains general type of use function.</p>
<p>Ordinary multi-manifold type: suitable for a variety of different materials, small freeze-dried, and can be linked to freeze-dried bottles, eggplant bottles, jars.</p>
<p>Grip multi-manifold type: Contains the function of ordinary multi-manifold type, can achieve the sample vacuum pressure package, to meet the vast majority of the laboratory technical requirements.</p>
<p>T-frame: for fungal ampoule tube package.</p>
<p>main feature:</p>
<p>(1) The machine uses international brands Danfoss compressor refrigeration, refrigeration quickly, cold trap temperature is low.</p>
<p>(2) 7-inch true color touch LCD screen control system, easy to operate, and powerful.</p>
<p>(3) industrial embedded operating system, ARM9 core control circuit design, 32M memory 128M FLASH, the operation response speed, large amount of stored data.</p>
<p>(4) the control system automatically saves the freeze-dried data, and can be real-time curve and historical curve in the form of view, the entire freeze-drying process clear.</p>
<p>(5) drying room with a colorless transparent injection molding polycarbonate drying trap, corrosion-resistant, non-friable, non-adhesive, high transparency, strong sealing, the sample is clear and intuitive, can observe the freeze-drying of the whole product.</p>
<p>(6) vacuum pump and host connection using international standard KF quick connector, simple and reliable.</p>
<p>(7) The machine can store multiple freeze-drying curve, and use U disk to extract data to the computer, with the host computer software in the computer to browse print and a variety of options.</p>
<p>(8) equipped with inflatable valve, can be filled with dry inert gas.</p>
<p>Second, the optional function:</p>
<p>* Eutectic point test function, master the material better sublimation temperature;</p>
<p>* Vacuum control function to maximize heat transfer;</p>
<p>* Double-stack refrigeration system, mature technology, low temperature, for -80 ℃ freeze dryer;</p>
<p>* Wide mouth manifold freeze-dried bottle configuration, easy to install the material, with the import standard freeze-dried bottle valve supporting the connection. Standard 6 tubes;</p>
<p>* Optional power defrost function, speed up the defrost speed, shorten the drying cycle;</p>
<p>* Optional multi-brand imported vacuum pump.</p>
<p><strong>N series freeze dryer parameter</strong></p>
<div class="table-responsive">
<table cellspacing="0" cellpadding="0">
<tbody>
<tr class="firstRow">
<td colspan="3">Model</td>
<td colspan="8">SCIENTZ-10N</td>
<td colspan="7">SCIENTZ-12N</td>
<td colspan="5">SCIENTZ-18N</td>
</tr>
<tr>
<td colspan="2">Type</td>
<td colspan="3">Ordinary</td>
<td>Top press</td>
<td colspan="2">Ordinary multi-pipline</td>
<td colspan="4">Top-press multi-pipeline</td>
<td>Ordinary</td>
<td>Top press</td>
<td colspan="2">Ordinary multi-pipline</td>
<td colspan="2">Top-press multi-pipeline</td>
<td>Ordinary</td>
<td>Top press</td>
<td colspan="2">Ordinary multi-pipline</td>
<td>Top-press multi-pipeline</td>
</tr>
<tr>
<td colspan="2">Dryer area(㎡)</td>
<td colspan="3">0.125</td>
<td>0.076</td>
<td colspan="2">0.125</td>
<td colspan="4">0.076</td>
<td>0.125</td>
<td>0.076</td>
<td colspan="2">0.125</td>
<td colspan="2">0.076</td>
<td>0.18</td>
<td>0.09</td>
<td colspan="2">0.18</td>
<td>0.09</td>
</tr>
<tr>
<td colspan="2">Ability to capture water(㎏/batch)</td>
<td colspan="3">3</td>
<td>3</td>
<td colspan="2">3</td>
<td colspan="4">3</td>
<td>3.5</td>
<td>3.5</td>
<td colspan="2">3.5</td>
<td colspan="2">3.5</td>
<td>4</td>
<td>4</td>
<td colspan="2">4</td>
<td>4</td>
</tr>
<tr>
<td rowspan="3"><a href="http://www.so.com/link?url=http://dict.youdao.com/search?q=penicillin%20bottle&amp;keyfrom=hao360&amp;q=%E8%A5%BF%E6%9E%97%E7%93%B6%E8%8B%B1%E8%AF%AD&amp;ts=1509518957&amp;t=6228008ccbeb1b149cd5a2b4ae6b258" target="https://www.so.com/_blank">Schering bottle</a> quantity</td>
<td>φ12mm</td>
<td colspan="3">920</td>
<td>560</td>
<td colspan="2">920</td>
<td colspan="4">560</td>
<td>920</td>
<td>560</td>
<td colspan="2">920</td>
<td colspan="2">560</td>
<td>1320</td>
<td>990</td>
<td colspan="2">1320</td>
<td>990</td>
</tr>
<tr>
<td>φ16mm</td>
<td colspan="3">480</td>
<td>285</td>
<td colspan="2">480</td>
<td colspan="4">285</td>
<td>480</td>
<td>285</td>
<td colspan="2">480</td>
<td colspan="2">285</td>
<td>698</td>
<td>349</td>
<td colspan="2">698</td>
<td>349</td>
</tr>
<tr>
<td>φ22mm</td>
<td colspan="3">260</td>
<td>165</td>
<td colspan="2">260</td>
<td colspan="4">165</td>
<td>260</td>
<td>165</td>
<td colspan="2">260</td>
<td colspan="2">165</td>
<td>360</td>
<td>184</td>
<td colspan="2">360</td>
<td>184</td>
</tr>
<tr>
<td colspan="2">Eggplant shape bottle</td>
<td colspan="3">0</td>
<td>0</td>
<td colspan="2">8</td>
<td colspan="4">8</td>
<td>0</td>
<td>0</td>
<td colspan="2">8</td>
<td colspan="2">8</td>
<td>0</td>
<td>0</td>
<td colspan="2">8</td>
<td>8</td>
</tr>
<tr>
<td colspan="2">Plate load capacity (L)</td>
<td colspan="3">3</td>
<td>3</td>
<td colspan="2">3</td>
<td colspan="4">3</td>
<td>3.5</td>
<td>3.5</td>
<td colspan="2">3.5</td>
<td colspan="2">3.5</td>
<td>4</td>
<td>4</td>
<td colspan="2">4</td>
<td>4</td>
</tr>
<tr>
<td colspan="2">Plate size(mm)</td>
<td colspan="3">φ200</td>
<td>φ180</td>
<td colspan="2">φ200</td>
<td colspan="4">φ180</td>
<td>φ200</td>
<td>φ180</td>
<td colspan="2">φ200</td>
<td colspan="2">φ180</td>
<td>φ240</td>
<td>φ200</td>
<td colspan="2">φ240</td>
<td>φ200</td>
</tr>
<tr>
<td colspan="2">Plate distance (mm)</td>
<td colspan="21">70</td>
</tr>
<tr>
<td colspan="2">Plate size(pc)</td>
<td colspan="2">4</td>
<td colspan="3">3</td>
<td colspan="2">4</td>
<td>3</td>
<td colspan="3">4</td>
<td>3</td>
<td>4</td>
<td colspan="2">3</td>
<td colspan="2">4</td>
<td>3</td>
<td>4</td>
<td colspan="2">3</td>
</tr>
<tr>
<td colspan="2">Cold chmaber size(mm)</td>
<td colspan="8">φ250×150</td>
<td colspan="7">φ250×250</td>
<td colspan="6">φ300×405</td>
</tr>
<tr>
<td colspan="2">Cold trap the lowest temperature(℃)</td>
<td colspan="21">≤-56(no load)</td>
</tr>
<tr>
<td colspan="2">Ultimate vacuum(Pa)</td>
<td colspan="21">≤5(no load)</td>
</tr>
<tr>
<td colspan="2">Power Kw(220V50Hz)</td>
<td colspan="8">0.95</td>
<td colspan="7">1</td>
<td colspan="6">1.3</td>
</tr>
<tr>
<td colspan="2">Amibient temperature℃)</td>
<td colspan="21">≤25</td>
</tr>
<tr>
<td colspan="2">Overall dimension(mm)</td>
<td colspan="8">590(L)×460(W)×400(H) ＋440</td>
<td colspan="7">600(L)×450(W)×720(H) ＋440</td>
<td colspan="6">670(L)×525(W)×910(H) ＋480</td>
</tr>
<tr>
<td colspan="2">weight(㎏)</td>
<td colspan="2">55</td>
<td colspan="3">61</td>
<td colspan="2">57</td>
<td>63</td>
<td colspan="3">63</td>
<td>70</td>
<td>65</td>
<td colspan="2">72</td>
<td colspan="2">79</td>
<td>85</td>
<td>81</td>
<td colspan="2">87</td>
</tr>
<tr>
<td colspan="2">Special note</td>
<td colspan="21">The device size   and weight not included in the external vacuum pump</p>
<p>Top press model height not included in   manual gland handle (The handle height 701mm)</td>
</tr>
<tr>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
</tbody>
</table>
</div>
<p>☛Optional function：▂double refrigeration system ,cold trap up to -80℃▃defrost function▄import vacuum pump ▅automatic nitrogen filling interface</p>
<p>▆T-type ampoule bottle rack</p>
<p><strong> <img decoding="async" title="product-1-1" src="https://www.scientzbio.com/Content/upload/2018213197/201808100948481985545.jpg" alt="photobank(29).jpg" /></strong></p>
<p><strong><img decoding="async" title="product-1-1" src="https://www.scientzbio.com/Content/upload/2018213197/201808100949029790286.jpg" alt="photobank(32).jpg" /></strong></p>
<p><strong><img decoding="async" title="product-1-1" src="https://www.scientzbio.com/Content/upload/2018213197/201808100949146837660.jpg" alt="photobank(30).jpg" /></strong></p>
<p><strong><img decoding="async" title="product-1-1" src="https://www.scientzbio.com/Content/upload/2018213197/201808100949231116766.jpg" alt="photobank(31).jpg" /></strong></p>
<p>The post <a href="https://keylaser.am/product/easy-operation-scientz-n-series-mini-freeze-drying-machine-for-sale-freeze-dryer/">Easy Operation Scientz-N Series Mini Freeze Drying Machine For Sale, Freeze Dryer</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Scientz-10N Lab Lyophilizer Vacuum Freeze Dryer Machine With Competitive Prices</title>
		<link>https://keylaser.am/product/scientz-10n-lab-lyophilizer-vacuum-freeze-dryer-machine-with-competitive-prices/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Tue, 07 Jul 2026 17:40:27 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=16806</guid>

					<description><![CDATA[<div class="pro-con">N series freeze dryer FREEZE-DRYING SYSTEM N series freeze-drying machine is compact, with large-scale freeze dryer flexibility, less space, can handle more flexible samples, cost-effective. Suitable for small laboratory, and can choose a variety of configurations: Common type: suitable for bulk...</div>
<p>The post <a href="https://keylaser.am/product/scientz-10n-lab-lyophilizer-vacuum-freeze-dryer-machine-with-competitive-prices/">Scientz-10N Lab Lyophilizer Vacuum Freeze Dryer Machine With Competitive Prices</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Freeze dryer application</strong></p>
<p>In the laboratory, lyophilization has many different uses and is indispensable in many biochemical and pharmaceutical applications. It is used to obtain biological materials that can be preserved for a long period of time, such as microbial culture, enzymes, blood, and pharmaceuticals, in addition to the long-term preservation stability, retaining its inherent biological activity and structure.</p>
<p>To this end, lyophilization is used to prepare tissue samples for structural studies (eg, electron microscopy studies). Freeze drying is also used in chemical analysis to obtain dried samples or to concentrate samples to increase analytical sensitivity. Freeze-drying stabilizes the sample composition without changing the chemical composition, which is an ideal analytical aid.</p>
<p><strong>Freeze drying example</strong></p>
<p><img decoding="async" title="product-1-1" src="https://www.scientzbio.com/Content/upload/2018213197/201809301632387083668.png" alt="image.png" /></p>
<p>Before drying                                                     After drying</p>
<p><img decoding="async" title="product-1-1" src="https://www.scientzbio.com/Content/upload/2018213197/201808151356515442838.jpg" alt="photobank(42).jpg" /></p>
<p>The post <a href="https://keylaser.am/product/scientz-10n-lab-lyophilizer-vacuum-freeze-dryer-machine-with-competitive-prices/">Scientz-10N Lab Lyophilizer Vacuum Freeze Dryer Machine With Competitive Prices</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Good Quality Freeze Dryer Dryer Area 0.125 Scientz-10N</title>
		<link>https://keylaser.am/product/good-quality-freeze-dryer-dryer-area-0-125-scientz-10n/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Tue, 07 Jul 2026 17:36:27 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=16798</guid>

					<description><![CDATA[<p>N series freeze dryer FREEZE-DRYING SYSTEM N series freeze-drying machine is compact, with large-scale freeze dryer flexibility, less space, can handle more flexible samples, cost-effective. Suitable for small laboratory, and can choose a variety of configurations: Common type: suitable for bulk...</p>
<p>The post <a href="https://keylaser.am/product/good-quality-freeze-dryer-dryer-area-0-125-scientz-10n/">Good Quality Freeze Dryer Dryer Area 0.125 Scientz-10N</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong> N series freeze-drying machine is compact, with large-scale freeze dryer flexibility, less space, can handle more flexible samples,cost effective. Suitable for small laboratory, and can choose a variety of configurations:Common type: suitable for bulk materials, liquid and solid dryGland type: suitable for $chexins, bottled material drying, can achieve sample vacuum pressure packagc. Contains general type ofuse function.<br />
Ordinary multi-manifold type: suitable for a variety of different materials, small freeze-dried, and can be linked to freeze-driedbottles,cggplant bottles,jars.Grip multi-manifold type: Contains the function of ordinary multi manifold type, can achieve the sample vacuum pressure package,to meet the vast majority of the laboratory technical requirements.T-frane:for fumgal anpoule tube packagc.<br />
main feature :<br />
(1) The machine uses international brands Danfoss, compressor refrigeration, refrigeration quickly, cold trap temperature is low(2)7-inch true color touch LCD screen control system,easy to operate, and powerful.(3) industrial embedded operating system, hRl9 core control circuit design, 32 memory 128 FLASH, the operation response speed,large amount of stored data.<br />
(4) the control system automatically saves the freezedried data, and can be real-time curve and historical curve in the form of<br />
view,the entire freeze-drying process clear.(5) drying room with a colorless transparent injection molding polycarbonate drying trap, corrosionresistant, non-friable,non-adhesive, high transparency, strong sealing, the sample is clear and intuitive, can cbserve the freeze-drying of the whole product(6) vacuum puup and host cornection using international standard Kf quick cornector, simple and reliable.(7) The machine can store multiple freeze&#8221;drying curve, anduse U disk to extract data to the computer, with the host computer softwarein the computer to browse print and a variety of options.(8)equipped with inflatable valve, can be filled with dry inert gas.Second,the optional function:<br />
* Eutectic point test function, master the material better sublimation temperature,<br />
*acuum control function to maximize heat transfer.<br />
* Double-stack refrigeration system, mature technology, low temperature, for -80 (&#8216;freeze dryer.<br />
* Wide mouth manifold freeze-dried bottle configuration, easy to install the material, with the import standard freeze-dried bottle<br />
valve supporting the connection. Standard 6 tubes;<br />
* Optional power defrost function, speed up the defrost speed, shorten the drying cycle,<br />
40ptional multi-brand imported vacu pup.</strong></p>
<p>The lyophilizers produced by Ningbo Scientz are as follows:</p>
<p>1.Scientz-F series silicone oil in-situ freeze dryer (air-cooled)</p>
<p>2.Scientz-F series silicone oil in-situ lyophilizer (water-cooled)</p>
<p>3.Scientz-ND series electric heating in situ freeze dryer</p>
<p>4.Scientz-ND series heated bell lyophilizer</p>
<p>This series of machines is divided into four configurations: normal type, gland type, multi-manifold common type, multi-manifold gland type with pre-freezing function</p>
<p>5.Scientz-N series bell freeze freeze dryer</p>
<p>This series of machines is divided into four configurations: normal type, gland type, multi-manifold common type, multi-manifold gland type with pre-freezing function</p>
<p>The post <a href="https://keylaser.am/product/good-quality-freeze-dryer-dryer-area-0-125-scientz-10n/">Good Quality Freeze Dryer Dryer Area 0.125 Scientz-10N</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>