<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Real-time Fluorescence Quantitative PCR Analyzer Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-tag/real-time-fluorescence-quantitative-pcr-analyzer/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-tag/real-time-fluorescence-quantitative-pcr-analyzer/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Thu, 05 Mar 2026 11:50:19 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>Real-time Fluorescence Quantitative PCR Analyzer Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-tag/real-time-fluorescence-quantitative-pcr-analyzer/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Fluorescent Quantitative PCR Detection System LEIA-X4 LEIA-X6</title>
		<link>https://keylaser.am/product/fluorescent-quantitative-pcr-detection-system-leia-x4-leia-x6/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 05 Mar 2026 11:42:41 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=14205</guid>

					<description><![CDATA[<p><label>Model: </label>LEIA-X4 LEIA-X6</p>
<p>Real-time PCR is used for sensitive, specific detection and quantification of nucleic acid targets. We have developed powerful assay design algorithms, optimized qPCR regent, intuitive data analysis software, and flexible instrumentation to help harness the power of qPCR across a rich and diverse set of applications. Explore our robust solutions for your qPCR-based research.</p>
<p>The post <a href="https://keylaser.am/product/fluorescent-quantitative-pcr-detection-system-leia-x4-leia-x6/">Fluorescent Quantitative PCR Detection System LEIA-X4 LEIA-X6</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Application:</strong></p>
<p>It can be widely used in infectious disease research, food pathogen detection, waterborne pathogen detection, drug analysis, stem cell research, pharmacogenomics research, tumor and genetic disease research, plant science and agricultural biotechnology.</p>
<p><strong>Working Principle:</strong></p>
<p>The temperature step change is controlled by the semiconductor Peltier to realize PCR amplification. Use high-sensitivity PD unit to detect fluorescence; Program control channel switching, non-contact excitation/detection on the top structure, coordinated with motor control X and Y axis movement to achieve 96-hole scanning. Finally, accurate analysis is carried out through powerful software.</p>
<figure id="attachment_14207" aria-describedby="caption-attachment-14207" style="width: 920px" class="wp-caption alignnone"><img fetchpriority="high" decoding="async" class="wp-image-14207 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/Fluorescent-Quantitative-Detection-System01.webp" alt="Fluorescent Quantitative PCR Detection System LEIA-X4 LEIA-X6" width="920" height="403" srcset="https://keylaser.am/wp-content/uploads/2026/03/Fluorescent-Quantitative-Detection-System01.webp 920w, https://keylaser.am/wp-content/uploads/2026/03/Fluorescent-Quantitative-Detection-System01-300x131.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/Fluorescent-Quantitative-Detection-System01-768x336.webp 768w, https://keylaser.am/wp-content/uploads/2026/03/Fluorescent-Quantitative-Detection-System01-600x263.webp 600w" sizes="(max-width: 920px) 100vw, 920px" /><figcaption id="caption-attachment-14207" class="wp-caption-text">Fluorescent Quantitative PCR Detection System LEIA-X4 LEIA-X6</figcaption></figure>
<p>&nbsp;</p>
<figure id="attachment_14208" aria-describedby="caption-attachment-14208" style="width: 1136px" class="wp-caption alignnone"><img decoding="async" class="wp-image-14208 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/Fluorescent-Quantitative-Detection-System02.webp" alt="Fluorescent Quantitative PCR Detection System LEIA-X4 LEIA-X6" width="1136" height="427" srcset="https://keylaser.am/wp-content/uploads/2026/03/Fluorescent-Quantitative-Detection-System02.webp 1136w, https://keylaser.am/wp-content/uploads/2026/03/Fluorescent-Quantitative-Detection-System02-300x113.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/Fluorescent-Quantitative-Detection-System02-1024x385.webp 1024w, https://keylaser.am/wp-content/uploads/2026/03/Fluorescent-Quantitative-Detection-System02-768x289.webp 768w, https://keylaser.am/wp-content/uploads/2026/03/Fluorescent-Quantitative-Detection-System02-600x226.webp 600w" sizes="(max-width: 1136px) 100vw, 1136px" /><figcaption id="caption-attachment-14208" class="wp-caption-text">Fluorescent Quantitative PCR Detection System LEIA-X4 LEIA-X6</figcaption></figure>
<p>&nbsp;</p>
<p><strong>Features:</strong></p>
<p>1. Excellent temperature control performance of the instrument, Module Max heating rate heating rate 7.0℃/s.</p>
<p>2. No edge effect, no optical path correction, top excitation/detection, non-contact measurement.</p>
<p>3. Fluorescence detection adopts PD sensor with high sensitivity.</p>
<p>4. Long-life LED light source, stable emission wavelength, maintenance-free.</p>
<p>5. 4/6-channel fluorescence detection, no cross interference between channels.</p>
<p>6. User-friendly and fully functional software, flexible program setting, comprehensive analysis and reporting functions, all the parameters can be stored.</p>
<p>&nbsp;</p>
<figure id="attachment_14209" aria-describedby="caption-attachment-14209" style="width: 569px" class="wp-caption alignnone"><img decoding="async" class="wp-image-14209 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/Fluorescent-Quantitative-Detection-System03.webp" alt="Fluorescent Quantitative PCR Detection System LEIA-X4 LEIA-X6" width="569" height="440" srcset="https://keylaser.am/wp-content/uploads/2026/03/Fluorescent-Quantitative-Detection-System03.webp 569w, https://keylaser.am/wp-content/uploads/2026/03/Fluorescent-Quantitative-Detection-System03-300x232.webp 300w" sizes="(max-width: 569px) 100vw, 569px" /><figcaption id="caption-attachment-14209" class="wp-caption-text">Fluorescent Quantitative PCR Detection System LEIA-X4 LEIA-X6</figcaption></figure>
<p>&nbsp;</p>
<p><strong>Real-time PCR Hardware:</strong></p>
<p>Thermoelectric cooling module (TEM) is a semiconductor device composed of many tiny and effective heat pumps. By applying a low-voltage DC power supply, heat will be transferred from one side of the TEM to the other side, resulting in a phenomenon that one side of the TEM becomes hot and the other side becomes cold. Since this phenomenon is completely reversible, when the polarity of the DC power supply is changed, it will be the opposite. This product adopts a long-life series TEM, which provides longer life and more efficiency during thermal cycling.</p>
<p><img loading="lazy" decoding="async" class="wp-image-14211 size-full" style="font-style: inherit; font-weight: 600;" src="https://keylaser.am/wp-content/uploads/2026/03/leia-x4-1.webp" alt="Fluorescent Quantitative PCR Detection System LEIA-X4 LEIA-X6" width="640" height="640" srcset="https://keylaser.am/wp-content/uploads/2026/03/leia-x4-1.webp 640w, https://keylaser.am/wp-content/uploads/2026/03/leia-x4-1-300x300.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/leia-x4-1-150x150.webp 150w, https://keylaser.am/wp-content/uploads/2026/03/leia-x4-1-600x600.webp 600w, https://keylaser.am/wp-content/uploads/2026/03/leia-x4-1-100x100.webp 100w" sizes="auto, (max-width: 640px) 100vw, 640px" /></p>
<p>Fluorescent Quantitative PCR Detection System LEIA-X4 LEIA-X6&nbsp;</p>
<p>The integrated design of the scanning module and the heating cover module, relying on its own gravity to compress the heating plate and the reagent cover, and is supported by four compression springs to prevent the sample tube from being crushed by four; at the same time, the rubber pad around the heating cover is pressed to ensure that there is no external light source interference in the detection ; The bottom of the cam mechanism is used to support the space to ensure the smooth sliding of the heating module; the guide rail mechanism on both sides of the heating module prevents the module from shifting and ensures the accuracy of the mechanical scanning structure.</p>
<p>&nbsp;</p>
<figure id="attachment_14217" aria-describedby="caption-attachment-14217" style="width: 640px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-14217 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/leia-x4-800-800.webp" alt="Fluorescent Quantitative PCR Detection System LEIA-X4 LEIA-X6" width="640" height="640" srcset="https://keylaser.am/wp-content/uploads/2026/03/leia-x4-800-800.webp 640w, https://keylaser.am/wp-content/uploads/2026/03/leia-x4-800-800-300x300.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/leia-x4-800-800-150x150.webp 150w, https://keylaser.am/wp-content/uploads/2026/03/leia-x4-800-800-600x600.webp 600w, https://keylaser.am/wp-content/uploads/2026/03/leia-x4-800-800-100x100.webp 100w" sizes="auto, (max-width: 640px) 100vw, 640px" /><figcaption id="caption-attachment-14217" class="wp-caption-text">Fluorescent Quantitative PCR Detection System LEIA-X4 LEIA-X6</figcaption></figure>
<p>&nbsp;</p>
<p>The software includes functions such as absolute quantification experiment, melting curve experiment, relative quantification (AACT) experiment, and genotyping experiment. Enter the attribute setting interface and select different function modules. Guided flow operation, convenient for users to quickly complete experimental settings. The software can open the recent experiment record template for easy viewing and the creation of new experiments.</p>
<p>&nbsp;</p>
<figure id="attachment_14210" aria-describedby="caption-attachment-14210" style="width: 1400px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-14210 size-full" src="https://keylaser.am/wp-content/uploads/2026/03/Fluorescent-Quantitative-Detection-System05.webp" alt="Fluorescent Quantitative PCR Detection System LEIA-X4 LEIA-X6" width="1400" height="862" srcset="https://keylaser.am/wp-content/uploads/2026/03/Fluorescent-Quantitative-Detection-System05.webp 1400w, https://keylaser.am/wp-content/uploads/2026/03/Fluorescent-Quantitative-Detection-System05-300x185.webp 300w, https://keylaser.am/wp-content/uploads/2026/03/Fluorescent-Quantitative-Detection-System05-1024x630.webp 1024w, https://keylaser.am/wp-content/uploads/2026/03/Fluorescent-Quantitative-Detection-System05-768x473.webp 768w, https://keylaser.am/wp-content/uploads/2026/03/Fluorescent-Quantitative-Detection-System05-600x369.webp 600w" sizes="auto, (max-width: 1400px) 100vw, 1400px" /><figcaption id="caption-attachment-14210" class="wp-caption-text">Fluorescent Quantitative PCR Detection System LEIA-X4 LEIA-X6</figcaption></figure>
<p>&nbsp;</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>LEIA-X4</td>
<td colspan="4">LEIA-X6</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Sample Capacity</td>
<td colspan="5">96*0.1ml PCR plate, 12*8-strip tubes, 96*0.1ml single tube (Transparent Cover)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Reaction System</td>
<td colspan="5">5~50μl</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Dynamics Range</td>
<td colspan="5">1~10¹⁰ copies</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Channel</td>
<td colspan="4">4</td>
<td>6</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Emission Light</td>
<td colspan="5">LED</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Detector</td>
<td colspan="5">PD</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Detection Path</td>
<td>F1: FAM/SYBR GREEN;</p>
<p>F2: VIC/JOE/HEX/TET;</p>
<p>F3: ROX/TEXAS-RED;</p>
<p>F4: Cy5</td>
<td colspan="4">F1: FAM/SYBR GREEN;</p>
<p>F2: VIC/JOE/HEX/TET;</p>
<p>F3:CY3;</p>
<p>F4: ROX/TEXAS RED;</p>
<p>F5: CY5;</p>
<p>F6: CY5.5</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Excitation Wavelength</td>
<td colspan="3">455~650nm</td>
<td colspan="2">455~685nm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Detection Wavelength</td>
<td colspan="2">510~710nm</td>
<td colspan="3">510~740nm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Fluorescence Detection Repeatability</td>
<td colspan="5">CV≤3%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Fluorescence Detection Accuracy</td>
<td colspan="5">CV≤5%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Fluorescence Detection Linearity</td>
<td colspan="5">r≥0.995</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Module Temp. Range</td>
<td colspan="5">4~105℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Ramp Rate</td>
<td colspan="5">7.0℃/s(max)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temp. Accuracy</td>
<td colspan="5">±0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temp. Uniformity</td>
<td colspan="5">≤±1℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temp. Control Mode</td>
<td colspan="5">Block and tube</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gradient Temp. Range</td>
<td colspan="5">It can be set within the temperature range of 30°C to 105°C, with a temperature gradient span of 1°C to 36°C</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Hot-Lid Temp. Range</td>
<td colspan="5">100℃, automatic hot-lid</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Scanning Mode</td>
<td colspan="5">Top scanning</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Operation Mode</td>
<td colspan="5">Continuous</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Scanning Time</td>
<td colspan="5">8.5s</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Special Function</td>
<td colspan="5">Absolute quantitative automatic analysis, relative quantification, SNP Analysis, melting curve analysis, etc.</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Operation System</td>
<td colspan="5">Microsoft: Windows 10</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Port Method</td>
<td colspan="5">USB Port</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Power Supply</td>
<td colspan="5">AC100~240V, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Dimension(W*D*H)</td>
<td colspan="5">375*505*375mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td colspan="5">28kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Packing Size(W*D*H)</td>
<td colspan="5">645*565*605mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td colspan="5">49kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>&nbsp;</p>
<p>The post <a href="https://keylaser.am/product/fluorescent-quantitative-pcr-detection-system-leia-x4-leia-x6/">Fluorescent Quantitative PCR Detection System LEIA-X4 LEIA-X6</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Novel Coronavirus (2019-nCoV) Nucleic Acid Detection Kit (Fluorescence PCR)</title>
		<link>https://keylaser.am/product/novel-coronavirus-2019-ncov-nucleic-acid-detection-kit-fluorescence-pcr/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 07 Oct 2024 17:56:34 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=10529</guid>

					<description><![CDATA[<p><strong>Introduction:</strong></p>
<p>This product selects the ORF1ab and N gene regions of 2019-novel coronavirus, and designs two sets of specific primers and fluorescent probes that cover two sites of the gene at the same time. In order to control the entire extraction and detection process, human <span style="font-family: 宋体;">β</span><span style="font-family: Calibri;">-Globin gene was act as a non-competitive internal control during the extraction and detection process. The RT-PCR reaction solution is pre-mixed, which is convenient, efficient and easy to operate. It utilizes high-efficiency Taq DNA Polymerase and has strong stability. The kit could be used for auxiliary diagnosis and epidemiological surveillance of 2019-novel coronavirus infection.</span></p>
<p>The post <a href="https://keylaser.am/product/novel-coronavirus-2019-ncov-nucleic-acid-detection-kit-fluorescence-pcr/">Novel Coronavirus (2019-nCoV) Nucleic Acid Detection Kit (Fluorescence PCR)</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<ul class="pro-itemspecifics-list fix">
<li><label>Model:</label>2019-nCoV) RT-QPCR Detection Kit</li>
<li><label>Brand:</label>BIOBASE</li>
</ul>
<p><strong>Advantages：</strong></p>
<p>1. Internal control: Human β-Globin gene as the internal control is included into the reagent to verify the validity of the experiment.</p>
<p>2. High sensitivity: The lowest detection limit is 500 copies/ml.</p>
<p>3. High specificity: Primers and probes are designed for specific fragments of two gene regions, which confirm each other to make the results more accurate. No cross-reactivity with other pathogens with the same site of infection or similar infection characteristics.</p>
<p>4. Strong stability: CV of each channel is all &lt;3%.</p>
<p>5. Multiple Real-time RT-PCR detection: Each channel does not interfere with each other, and the amplification curve is S-shaped.</p>
<p>6. Simple operation: One-step method to complete RT-PCR, The whole procedure can be detected within 80min.</p>
<p>7.Fast speed: The PCR amplification time is less than 80 minutes.</p>
<p>&nbsp;</p>
<figure id="attachment_10530" aria-describedby="caption-attachment-10530" style="width: 785px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-10530 size-full" src="https://keylaser.am/wp-content/uploads/2024/10/DATA.webp" alt="Novel Coronavirus (2019-nCoV) Nucleic Acid Detection Kit (Fluorescence PCR)" width="785" height="304" srcset="https://keylaser.am/wp-content/uploads/2024/10/DATA.webp 785w, https://keylaser.am/wp-content/uploads/2024/10/DATA-300x116.webp 300w, https://keylaser.am/wp-content/uploads/2024/10/DATA-768x297.webp 768w, https://keylaser.am/wp-content/uploads/2024/10/DATA-600x232.webp 600w" sizes="auto, (max-width: 785px) 100vw, 785px" /><figcaption id="caption-attachment-10530" class="wp-caption-text"> </figcaption></figure>
<p>&nbsp;</p>
<p><strong>Technical Parameters:</strong></p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="866">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td width="294">Product Name</td>
<td width="571">Novel Coronavirus(2019-nCoV) Nucleic Acid Detection Kit(Fluorescence PCR)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="294">Detection Principle</td>
<td width="571">Fluorescence PCR</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="294">Detection Target</td>
<td width="571">Novel coronavirus (2019-Ncov) ORF1ab and N gene</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="294">Applicable Instrument</td>
<td width="571">Fluorescence quantitative PCR instrument</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="294">Storage Conditions</td>
<td width="571">-20±5℃, keep away from light</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="294">Valid Period</td>
<td width="571">Unopened ≥6 months; Opened≥90 days</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="294">Sample Volume</td>
<td width="571">7μl</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="294">Reaction Volume</td>
<td width="571">20μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="294">Detection Limit</td>
<td width="571">500 copies/ml</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="294">Stability</td>
<td width="571">CV&lt;3%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="294">Interpretation of Positive Results</td>
<td width="571">CT≤38</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="294">Packing Specification</td>
<td width="571">48T/box; 60 boxes/carton</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td width="294">Packet Size</td>
<td width="571">500*500*500mm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td width="294">Gross Weight</td>
<td width="571">23kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>*Not Available in the U.S.</p>
<p>The post <a href="https://keylaser.am/product/novel-coronavirus-2019-ncov-nucleic-acid-detection-kit-fluorescence-pcr/">Novel Coronavirus (2019-nCoV) Nucleic Acid Detection Kit (Fluorescence PCR)</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Gene Amplification Instrument TEC01</title>
		<link>https://keylaser.am/product/gene-amplification-instrument-tec01/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 07 Oct 2024 17:52:03 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=10525</guid>

					<description><![CDATA[<div><strong>Introduction:</strong></div>
<p>The gene amplification instrument is an instrument that performs nucleic acid amplfication by polymerase chain reaction.<br />
Mainly used in Medical institutions, clinical gene amplification testing laboratories that meet the requirements, scientific research institutes, universities, etc.</p>
<p>The post <a href="https://keylaser.am/product/gene-amplification-instrument-tec01/">Gene Amplification Instrument TEC01</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. Reliable performance of heating and cooling elements, high-performance temperature control system.<br />
2. High-performance digital signal processor for precise temperature control.<br />
3. Excellent temperature uniformity.</p>
<p>4. Rapid heating and cooling.</p>
<p>5. 7-inch color touch panel, easy to operate.<br />
6. Support large-capacity program storage.</p>
<p><strong>Technical Parameters:</strong></p>
<div>
<div>
<div>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table align="left">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td>Model</td>
<td>TEC01</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Capacity</td>
<td>96</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Reaction Volume</td>
<td>10~200μl</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Tube Type</td>
<td>96*0.2ml PCR plate, 8*0.2ml PCR tube</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Block Temperature Range</td>
<td>4℃~105℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Heat Lid Temperature Range</td>
<td>30℃~110℃, When the set temperature is lower than 30°, the heat lid will be closed automatically</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Display Resolution</td>
<td>±0.1℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature Accuracy</td>
<td>≤0.5℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Temperature Uniformity</td>
<td>≤1℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Block Material</td>
<td>Aluminum</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gradient Range</td>
<td>30~99℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Temperature Differential Range</td>
<td>1~42℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Program</td>
<td>A single program can be up to 30 steps, 99 cycles</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Display</td>
<td>7&#8243; LCD</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Power Supply</td>
<td>110V~220V, 50/60Hz</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>External Size(L*W*H)</td>
<td>398*280*257mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Net Weight</td>
<td>11kg</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td>Package Size(L*W*H)</td>
<td>495*380*380mm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td>Gross Weight</td>
<td>17kg</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/gene-amplification-instrument-tec01/">Gene Amplification Instrument TEC01</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluorescence Quantitative PCR Detection System</title>
		<link>https://keylaser.am/product/fluorescence-quantitative-pcr-detection-system/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 07 Oct 2024 17:44:08 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=10511</guid>

					<description><![CDATA[<p>Features * Whole block scanning and formulated line scanning mode, 96-well double-colour scaning takes only 5.5s * 6 channels fluorescencedetection,no cross talk between different channels. * Unique bottom detection,compatible to reaction volume down to 5μl * New automatic hot lid,automatic open and close which is prevenT reagent evaporation * LED excitation light source with super long service life [&#8230;]</p>
<p>The post <a href="https://keylaser.am/product/fluorescence-quantitative-pcr-detection-system/">Fluorescence Quantitative PCR Detection System</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features</strong></p>
<p>* Whole block scanning and formulated line scanning mode, 96-well double-colour scaning takes only 5.5s</p>
<p>* 6 channels fluorescencedetection,no cross talk between different channels.</p>
<p>* Unique bottom detection,compatible to reaction volume down to 5μl</p>
<p>* New automatic hot lid,automatic open and close which is prevenT reagent evaporation</p>
<p>* LED excitation light source with super long service life</p>
<p>* New TE module with special technique to ensure long service life</p>
<p>* Available for a variety of scientific research and clinical applications.</p>
<p><strong>Models:</strong></p>
<p>Technical Parameters</p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table>
<tbody>
<tr class="firstRow">
<td>Product Name</td>
<td colspan="6">Fluorescence Quantitative PCR Detection System</td>
</tr>
<tr>
<td>Model</td>
<td colspan="6">FQD-96A</td>
</tr>
<tr>
<td>Sample Capacity</td>
<td colspan="6">96&#215;0.2ml PCR plate, 12&#215;8-strip tubes, 96*0.2ml single tube(Transparent Bottom)</td>
</tr>
<tr>
<td>Reaction system</td>
<td colspan="6">5~100μl</td>
</tr>
<tr>
<td>Dynamics Range</td>
<td colspan="6">1-1010</td>
</tr>
<tr>
<td>Medical instrument registration certificate</td>
<td colspan="6">G.X.Z. 20153400273</td>
</tr>
<tr>
<td>Channel</td>
<td colspan="6">4</td>
</tr>
<tr>
<td>Emission Wavelength</td>
<td colspan="6">500-800nm</td>
</tr>
<tr>
<td>Detection path</td>
<td>F1</td>
<td>F2</td>
<td>F3</td>
<td>F4</td>
<td>F5</td>
<td>F6</td>
</tr>
<tr>
<td>Suitable probe.dye</td>
<td>FAM,SYBR GREEN I</td>
<td>HEX/VIC/TET/JOE/CY3/NED/TAMRA</td>
<td>ROX,TEXAS-RED</td>
<td>Cy5</td>
<td>Cy5.5</td>
<td>Reserved path</td>
</tr>
<tr>
<td>Excitation wavelength</td>
<td colspan="6">300~800nm</td>
</tr>
<tr>
<td>Detection wavelength</td>
<td colspan="6">500~800nm</td>
</tr>
<tr>
<td>Module temp. range</td>
<td colspan="6">4-105℃(resolution:0.1℃) withSOAK Low Temp.storage Function</td>
</tr>
<tr>
<td>RampRate</td>
<td colspan="6">4.0℃/s(max)</td>
</tr>
<tr>
<td>Temp. Control accuracy</td>
<td colspan="6">±0.1℃</td>
</tr>
<tr>
<td>Temp. uniformity</td>
<td colspan="6">≤ ±0.3℃</td>
</tr>
<tr>
<td>Temp. control mode</td>
<td colspan="6">Block mode andTube Mode</p>
<p>(Automaticcontrolbasedonliquid level)</td>
</tr>
<tr>
<td>Operation mode</td>
<td colspan="6">Continuous operation</td>
</tr>
<tr>
<td>Gradient Temp. Range</td>
<td colspan="6">1-36℃</td>
</tr>
<tr>
<td>Hot-lid Temp. Range</td>
<td colspan="6">30-110℃(Adjustable, Defaultby105℃ and Automatic Hot-lid)</td>
</tr>
<tr>
<td>FluorescenceintenseDetection Repeatability</td>
<td colspan="6">5%</td>
</tr>
<tr>
<td>Scanning Mode</td>
<td colspan="6">Full plate scanning and designated line scanning</td>
</tr>
<tr>
<td>Programming</td>
<td colspan="6">Max 20 Segments for Each Program, Max 99 Cycles</td>
</tr>
<tr>
<td>Operation Mode</td>
<td colspan="6">Continuous</td>
</tr>
<tr>
<td>Scanning time</td>
<td colspan="6">5.5s</td>
</tr>
<tr>
<td>Special function</td>
<td colspan="6">Absolute quantitative automatic analysis, relative quantification, SNP Analysis, melting curveanalysis,6 independent temperature zones, HRMmulti-channel crosstalk calibration, background correction, auto gain, customized parameters,etc</td>
</tr>
<tr>
<td>Operation system</td>
<td colspan="6">Microsoft:Windows7/Windows8.1/ Windows10 Software:excel2000/2002/2003/2007/2012</td>
</tr>
<tr>
<td>Min computer configuration</td>
<td colspan="6">RAM:512M,hardware space:10GB CPU:Pentium 4 virtual memory≥1000MB</td>
</tr>
<tr>
<td>Power supply</td>
<td colspan="6">100-240V 50/60Hz 600W</td>
</tr>
<tr>
<td>Dimension(L*W*H)</td>
<td colspan="6">410*386*352mm</td>
</tr>
<tr>
<td>Port method</td>
<td colspan="6">SupportUSBandRS232data port andBluetoothport</td>
</tr>
<tr>
<td>Certification</td>
<td colspan="6">Ferrotec Peltier/CE/EMC/RoHS2.0/PICC</p>
<p>Product quality liability insurance/IVD/MET</td>
</tr>
<tr>
<td>Packing size</td>
<td colspan="6">720*680*640mm</td>
</tr>
<tr>
<td>Gross weight</td>
<td colspan="6">55kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>&nbsp;</p>
<p>The post <a href="https://keylaser.am/product/fluorescence-quantitative-pcr-detection-system/">Fluorescence Quantitative PCR Detection System</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluorescent Quantitative PCR Detection System</title>
		<link>https://keylaser.am/product/fluorescent-quantitative-pcr-detection-system/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 07 Oct 2024 17:41:08 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=10501</guid>

					<description><![CDATA[<p>Real- time PCR is used for sensitive, specific detection and quantification of nucleic acid targets. We have developed powerful assay design algorithms, optimized qPCR regent, intuitive data analysis software, and flexible instrumentation to help harness the power of qPCR across a rich and diverse set of applications. Explore our robust solutions for your qPCR-based research.</p>
<p>The post <a href="https://keylaser.am/product/fluorescent-quantitative-pcr-detection-system/">Fluorescent Quantitative PCR Detection System</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="proddetails-detial-wrap">
<div class="detial-wrap-cont">
<div class="detial-cont-index">
<div class="detial-cont-divsions detial-cont-prodescription">
<div class="detial-cont-tabscont">
<div class="fix prodDesc">
<div class="prodDetail-editor-container">
<p><strong>Feature:</strong></p>
<p>♦ Six independent temperature control</p>
<p>♦ Thermal compensation technology of temperature module</p>
<p>♦ No edge effect of temperature and optics have</p>
<p>♦ Maintenance-free long &#8211; life continuous spectral excitation source</p>
<p>♦ Synchronous and fast acquisition of low temperature CCD 0.15s in cold state</p>
<p>♦ Relative quantitative high sensitivity 1.5 times effective discrimination</p>
<p>♦ Flexible, open and user-friendly software platform</p>
<p>♦ Open reagent consumable platform</p>
<p><strong>Application:</strong></p>
<p>♦ Basic materials research</p>
<p>♦ Pathogen detection</p>
<p>♦ Public health safety surveillance</p>
<p>♦ Meat products adulterated</p>
<p>♦ Transgenic testing</p>
<p>♦ Food safety inspection</p>
<p>♦ Drug development and rational drug use</p>
<p>♦ Precise tumor treatment</p>
<p>♦ Gene expression</p>
<p>♦ Genetic screening</p>
<p>♦ Genotyping</p>
<p>♦ Stem cell research</p>
<p><strong>Temperature control module</strong></p>
<p>On the basis of the six independent temperature control technology, using the enclosed liquid heat transfer efficiency, combined with environmental scanning monitoring regulation auxiliary infrared with heating and intelligent variable frequency system voltage, current, ensures the module heating speed, effectively prevents temperature overshoot no edge effect and the evaporation temperature, not only saves your precious time to amplify the required temperature uniformity and the repeatability of the results achieved perfection, no matter what kind of test mode, application, it can get good data uniformity and repeatability.</p>
<p><strong>Optical module</strong></p>
<p>On behalf of the world&#8217;s leading optical transmission and collection technology, use optical fiber after the excitation light source for reaction system and the emission of light from the reaction system after excitation, the energy attenuation without conduction to each reaction holes and cold CCD, from physical properties to ensure consistency and authenticity of the excitation and detection, and greatly improve the detection sensitivity, can make your low effective detection and distinguish easily copy sample. The channel mismatch function is added to extend the application field of qPCR to the protein level and provide a new way for the construction of multiple systems of diagnostic reagents.</p>
<p>&nbsp;</p>
<div class="sliderTable mt10 mb10 sliderTable-index0">
<div class="inner">
<table width="866">
<tbody>
<tr class="firstRow">
<td valign="bottom" width="100">Channel</td>
<td valign="bottom" width="186">Excitation</p>
<p>wavelength (nm)</td>
<td valign="bottom" width="187">Emission</p>
<p>wavelength (nm)</td>
<td valign="bottom" width="393">Examples of fluorescent dyes</td>
</tr>
<tr>
<td valign="center" width="100">1 Blue</td>
<td valign="center" width="186">460-480</td>
<td valign="center" width="187">512-528</td>
<td valign="center" width="393">FAM/SYBR Green I/Eva Green…</td>
</tr>
<tr>
<td valign="center" width="100">2 Green</td>
<td valign="center" width="186">515-535</td>
<td valign="center" width="187">562~578</td>
<td valign="center" width="393">VIC/JOE/HEX/TET…</td>
</tr>
<tr>
<td valign="center" width="100">3 Yellow</td>
<td valign="center" width="186">560~580</td>
<td valign="center" width="187">612~628</td>
<td valign="center" width="393">ROX/Texas Red …</td>
</tr>
<tr>
<td valign="center" width="100">4 Red</td>
<td valign="center" width="186">610-630</td>
<td valign="center" width="187">662~678</td>
<td valign="center" width="393">Cy5…</td>
</tr>
<tr>
<td valign="center" width="100">5 Red</td>
<td valign="center" width="186">660-680</td>
<td valign="center" width="187">702~718</td>
<td valign="center" width="393">Cy5.5/Quasar705…</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>&nbsp;</p>
<p>♦ Channel combination: 6-color excitation light filter and 6-color detection light filter can detect≥21 different fluorescence spectra, channels are completely open, supporting third-party reagent optimization Support FRET application.</p>
<p>♦ Multichannel static fluorescence function: analysis of starting template and end product.</p>
<p>♦ Filter can be customized according to customer need</p>
<p>&nbsp;</p>
<p><strong>Software platform</strong></p>
<p>Real-time monitoring, automatic discrimination and calculation of positive and negative results, automatic establishment of standard curve, absolute/relative quantitative, multiple quantitative, fusion curve, gene mutation, quality control graphic analysis, fluorescence correction, PCR amplification efficiency, high-resolution fusion curve (optional match), etc.</p>
<p><strong>Models：</strong></p>
<p>Technical parameters:</p>
<div class="sliderTable mt10 mb10 sliderTable-index1">
<div class="inner">
<table width="866">
<tbody>
<tr class="ue-table-interlace-color-single firstRow">
<td valign="center" width="162">Product Name</td>
<td colspan="5" valign="center">Fluorescence Quantitative PCR Detection System</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="162">Model</td>
<td colspan="5" valign="center">MA-6000</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="162">Sample Capacity</td>
<td colspan="5" valign="center">96&#215;0.2ml PCR plate, 12&#215;8-strip tubes, 96*0.2ml single tube</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="162">Reaction System</td>
<td colspan="5" valign="center">6~125μl</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="162">Dynamics Range</td>
<td colspan="5" valign="center">1-1010 copies</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="250">Channel</td>
<td colspan="5" valign="center">5</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="57">Emission Light</td>
<td colspan="5" valign="center">Full-wavelength maintenance-free halogen tungsten lamp</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="162">Detector</td>
<td colspan="5" valign="center">-20℃ CCD</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="250">Detection Path</td>
<td valign="center" width="131">F1</td>
<td valign="center" width="57">F2</td>
<td valign="center" width="68">F3</td>
<td valign="center" width="162">F4</td>
<td valign="center" width="162">F5</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="162">Suitable Probe/Dye</td>
<td valign="center" width="162">FAM/SYBR Green/Eva Green/LC Green/Fluorescein</td>
<td valign="center" width="162">VIC/HEX/TET/Cy3/JOE/Alex a555</td>
<td valign="center" width="162">ROX/Cy3.5/Texas Red</td>
<td valign="center" width="162">Cy5/LC Red640</td>
<td valign="center" width="162">Cy5.5/LC Red705</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="162">Excitation Wavelength</td>
<td colspan="5" valign="center">380~780nm</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="162">Detection Wavelength</td>
<td colspan="5" valign="center">380~780nm</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="162">Fluorescence Detection Repeatability</td>
<td colspan="5" valign="center">CV≤3%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="162">Fluorescence Detection Precision</td>
<td colspan="5" valign="center">CV≤ 5%</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="162">Sample Detection Repeatability</td>
<td colspan="5" valign="center">CV≤3%</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="162">Fluorescence Detection Linearity</td>
<td colspan="5" valign="center">r≥0.980</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="162">Confidence</td>
<td colspan="5" valign="center">It can effectively distinguish 5000 and 1000copies with99.8% confidence degree</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="undefined">Module Temp. Range</td>
<td colspan="5" valign="center">4-100℃(resolution:0.1℃)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="undefined">Heating Speed</td>
<td colspan="5" valign="center">5.0℃/s(Max), 3.5℃/ s(Avg)</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="undefined">Cooling Speed</td>
<td colspan="5" valign="center">5.0℃/s(Max), 3.2℃/ s(Avg)</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="undefined">Temp. Accuracy</td>
<td colspan="5" valign="center">±0.1℃</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="undefined">Temp. Uniformity</td>
<td colspan="5" valign="center">≤ ±0.25℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="undefined">Number of Temp. Control Areas</td>
<td colspan="5" valign="center">6</p>
<p>&nbsp;</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="undefined">Gradient Temp. Range</td>
<td colspan="5" valign="center">1-32℃</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="undefined">Hot-Lid Temp. Range</td>
<td colspan="5" valign="center">104℃, Automatic Hot-lid</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="undefined">Special Function</td>
<td colspan="5" valign="center">Absolute quantification, Relative Quantification, Genotyping, Amplification efficiency calculation, Melting curve.</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="undefined">Operation System</td>
<td colspan="5" valign="center">Windows 7 64-bit or higher</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="undefined">Power Supply</td>
<td colspan="5" valign="center">100~240V,50~60Hz</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="undefined">Dimension(L*W*H) mm</td>
<td colspan="5" valign="center">600*390 *320</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="undefined">Port Method</td>
<td colspan="5" valign="center">USB Port</td>
</tr>
<tr class="ue-table-interlace-color-single">
<td valign="center" width="undefined">Packing Size(L*W*H) Mm</td>
<td colspan="5" valign="center">850*600 *650</td>
</tr>
<tr class="ue-table-interlace-color-double">
<td valign="center" width="undefined">Gross Weight</td>
<td colspan="5" valign="center">51</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="pro-detials-listshow fix">
<div class="flr"></div>
</div>
<p>The post <a href="https://keylaser.am/product/fluorescent-quantitative-pcr-detection-system/">Fluorescent Quantitative PCR Detection System</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
