<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Syncretize Electric Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-tag/syncretize-electric/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-tag/syncretize-electric/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Sat, 18 Jul 2026 11:47:10 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.5</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>Syncretize Electric Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-tag/syncretize-electric/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>SCIENTZ-2C Touch Display Gene Electroporator Intelligent</title>
		<link>https://keylaser.am/product/17980/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Sat, 18 Jul 2026 11:46:53 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=17980</guid>

					<description><![CDATA[<div class="pro-con">SCIENTZ-2C Gene electroporator (intelligent) Patent Number ： 200630105829.4 СЄ The instrument is widely applicable to the electro-perforation of microorganism cells of animals and plants and is also used for cell hybrid and mixing as well as gene electroporation. The instrument is of a complete...</div>
<div class="a2a_kit a2a_kit_size_32 a2a_default_style"></div>
<p>The post <a href="https://keylaser.am/product/17980/">SCIENTZ-2C Touch Display Gene Electroporator Intelligent</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The instrument is widely applicable to the electro-perforation of microorganism cells of animals and plants and is also used for cell hybrid and mixing as well as gene electroporation. The instrument is of a complete set with man-computer dialog interface. It is simple in operation and visual in apperance, and the detailed setting range of capacitance and resistancemakes the electro-perforation experiment of cells more selective under the related conditions.</p>
<p><strong>Characteristics</strong></p>
<p><strong>Networking of gene importer systems</strong></p>
<p>General intelligent instrumentation has two-way communication functions, but this two-way communication function is far from the true network communication.</p>
<p>Along with the rapid development of network technology, Internet technology enables the gene importer to realize network at the same time on the basis of intelligentization, so that the on-site measurement and control parameters are close to the network and have the necessary information processing functions.</p>
<p><img decoding="async" title="SCIENTZ-2C Touch Display Gene Electroporator Intelligent" src="https://www.scientzbio.com/Content/upload/2018213197/201807310900455204641.png?size=x0" alt="SCIENTZ-2C Touch Display Gene Electroporator Intelligent" /></p>
<p>&nbsp;</p>
<p>New Models：</p>
<p>SCIENTZ-2CS</p>
<p><img fetchpriority="high" decoding="async" title="SCIENTZ-2CS" src="https://www.scientzbio.com/uploads/12950/products/p20250628083000e627b.jpg?size=600x0" alt="SCIENTZ-2CS" width="600" height="400" /></p>
<div class="tabs-nav">
<p class="active"><strong>Technical Parameters</strong></p>
</div>
<div class="l-wrap">
<div class="tabs-cont pro-detail-box">
<div class="tabs-item">
<div class="table-responsive">
<table class="table" border="1" cellspacing="1" cellpadding="1">
<thead>
<tr>
<th>Parameter</th>
<th>Details</th>
</tr>
</thead>
<tbody>
<tr>
<td>Model</td>
<td>Scientz-2C</td>
</tr>
<tr>
<td>High Output Voltage</td>
<td>400 &#8211; 2500V</td>
</tr>
<tr>
<td>Low Output Voltage</td>
<td>100 &#8211; 450V</td>
</tr>
<tr>
<td>High Voltage Capacitor</td>
<td>1μF, 5μF, 6μF, 25μF, 30μF, 31μF</td>
</tr>
<tr>
<td>Low Voltage Capacitor</td>
<td>100μF to 1675μF (25μF increment per grade)</td>
</tr>
<tr>
<td>Resistance</td>
<td>50Ω, 100Ω, 150Ω, 1600Ω; -∞ (total 30 grades)</td>
</tr>
<tr>
<td>Operation System</td>
<td>Microcomputer control</td>
</tr>
<tr>
<td>Output Waveform</td>
<td>Exponential decay wave with RC time constant</td>
</tr>
<tr>
<td>Dimension</td>
<td>36.8×31.6×22.9 cm</td>
</tr>
<tr>
<td>Weight</td>
<td>10.5 Kg</td>
</tr>
<tr>
<td>Packing Size</td>
<td>480×420×280 mm</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
<p>The post <a href="https://keylaser.am/product/17980/">SCIENTZ-2C Touch Display Gene Electroporator Intelligent</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Gene Electroporator Scientz-2C</title>
		<link>https://keylaser.am/product/gene-electroporator-scientz-2c/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Sat, 18 Jul 2026 11:45:04 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=17976</guid>

					<description><![CDATA[<div class="pro-con">Electricity transformation can be used to putting the DNA into the state of bacteria, animal and plant cells, yeast cells.Relative chemical method, electric reforming process can obtain higher efficiency.This method is better than other methods to get repetitive more, easy to operate and save...</div>
<div class="a2a_kit a2a_kit_size_32 a2a_default_style"></div>
<p>The post <a href="https://keylaser.am/product/gene-electroporator-scientz-2c/">Gene Electroporator Scientz-2C</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Networking of the gene importer system. General intelligent instrumentation has two-way communication functions, but this two-way communication function is far from the true network communication.</p>
<p>Along with the rapid development of network technology, Internet technology enables the gene importer to realize network at the same time on the basis of intelligentization, so that the on-site measurement and control parameters are close to the network and have the necessary information processing functions.</p>
<p>&nbsp;</p>
<p><strong>Performance Features:</strong></p>
<p>■Integration of the whole machine, simple operation, direct display<br />
■The microprocessor control of pulse discharge<br />
■The log storage<br />
■Unlimited custom program storage<br />
■Simple operation, short conversion time<br />
■High conversion efficiency<br />
■repeat ability</p>
<p>&nbsp;</p>
<p><strong>Import method</strong></p>
<p>Sticky end connection</p>
<p>Flat end connection</p>
<p>Artificial joint method</p>
<p>Homologous polytail junction</p>
<p><strong> Main Technical Parameters:</strong></p>
<div class="table-responsive">
<table cellspacing="0" cellpadding="0">
<tbody>
<tr class="firstRow">
<td width="149">Model</td>
<td width="310">Scientz-2C</td>
</tr>
<tr>
<td width="149">Pulse form</td>
<td width="310">Exponential decay</td>
</tr>
<tr>
<td width="149">High Output voltage</td>
<td width="310">400-2500 VAC</td>
</tr>
<tr>
<td width="149">Low output voltage</td>
<td width="310">100-450 VAC</td>
</tr>
<tr>
<td width="149">High voltage capacitor</td>
<td width="310">1、5、6、25、30、31UF</td>
</tr>
<tr>
<td width="149">Low voltage  capacitor</td>
<td width="310">100UF，125UF，150UF…1675UF，one   grades of 25UF</td>
</tr>
<tr>
<td width="149">Resistance</td>
<td width="310">50、100、150、1600；-∞total   30 grades</td>
</tr>
<tr>
<td width="149">Operationg system</td>
<td width="310">Microcomputer control</td>
</tr>
<tr>
<td width="149">Output waveform</td>
<td width="310">With RC time constant of the exponential   decay of wave</td>
</tr>
<tr>
<td width="149">Dimension</td>
<td width="310">36.8×31.6×22.9(cm)</td>
</tr>
<tr>
<td width="149">Weight</td>
<td width="310">10.5Kg</td>
</tr>
<tr>
<td width="149">Packing size</td>
<td width="310">480×420×280mm</td>
</tr>
</tbody>
</table>
</div>
<p><img decoding="async" src="https://www.scientzbio.com/Content/upload/2018213197/201808081054548751689.jpg" alt="photobank(176).jpg" width="785" height="639" /></p>
<p>The post <a href="https://keylaser.am/product/gene-electroporator-scientz-2c/">Gene Electroporator Scientz-2C</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CRY-3B Laboratory Electric Cell Fusion System</title>
		<link>https://keylaser.am/product/cry-3b-laboratory-electric-cell-fusion-system/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Sat, 18 Jul 2026 11:43:23 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=17968</guid>

					<description><![CDATA[<div class="pro-con">CRY － 3B Syncretize Electric suitable for cell hybridization and cell fusion and direct observations can be made under inverted microscopes. It has a widespread application in the research on microorganism, animal medicine and bio-engineering. It provides safety, ease of use, and efficiency as...</div>
<div class="a2a_kit a2a_kit_size_32 a2a_default_style"></div>
<p>The post <a href="https://keylaser.am/product/cry-3b-laboratory-electric-cell-fusion-system/">CRY-3B Laboratory Electric Cell Fusion System</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Product Overview</h2>
<p>The CRY-3B Integrated Electric Cell Fusion Instrument is suitable for cell hybridization and cell fusion experiments, enabling direct observation under an inverted microscope. It is widely applied in microbiology research, veterinary medicine, and bioengineering fields. Compared with conventional methods, it offers enhanced safety, ease of use, and efficiency. Both planar electrodes and needle electrodes are available for selection.</p>
<h3>Core Performance Features</h3>
<p><strong>Dual Functions</strong>: Capable of both cell electrofusion and electroporation.</p>
<p><strong>Wide Parameter Range</strong>: Flexible adjustment of voltage and pulse time to meet diverse experimental needs.</p>
<p><strong>Fast &amp; Efficient</strong>: Completes cell arrangement, fusion, and post-processing in just a few seconds; simple and rapid post-operation steps.</p>
<p><strong>Intuitive Operation</strong>: LCD touch screen for easy and quick data setting and operation.</p>
<h2></h2>
<h2>Applications</h2>
<p>Cell fusion (fusion process observable under inverted microscope)</p>
<p>Nuclear transfer</p>
<p>Embryo manipulation</p>
<p>Hybridoma production</p>
<p>Plant protoplast fusion</p>
<p>Chicken embryo gene delivery</p>
<p>Live cell gene/drug transfection</p>
<h2></h2>
<h2>Main Technical Parameters</h2>
<div class="table-responsive">
<table class="table" border="1" cellspacing="1" cellpadding="1">
<thead>
<tr>
<th>Parameter</th>
<th>Specification</th>
</tr>
</thead>
<tbody>
<tr>
<td><strong>AC Electric Field Parameters</strong></td>
<td></td>
</tr>
<tr>
<td>Bunch Pulse Voltage</td>
<td>Peak-peak value: 0-58V (0-±29V), continuously adjustable</td>
</tr>
<tr>
<td>Bunch Pulse Frequency</td>
<td>30KHz-3000KHz, adjustable</td>
</tr>
<tr>
<td>Gate Time</td>
<td>10-1000μs, step adjustment of 1μs, continuously adjustable</td>
</tr>
<tr>
<td><strong>DC Electric Field Parameters</strong></td>
<td></td>
</tr>
<tr>
<td>Square Wave Fusion Pulse Voltage</td>
<td>5-600V adjustable (based on electrode distance); electric field intensity up to 6000V/cm at 1.0mm electrode distance</td>
</tr>
<tr>
<td>Square Wave Fusion Pulse Duration</td>
<td>5-5000μs, step adjustment of 1μs, continuously adjustable</td>
</tr>
<tr>
<td>Number of Fusion (Square Wave) Pulses</td>
<td>1-9 pulses</td>
</tr>
<tr>
<td>Standard Electrode</td>
<td>Fusion planar electrode with 0.5mm polar distance (optional electrodes listed below)</td>
</tr>
<tr>
<td>Net Weight</td>
<td>9.22Kg</td>
</tr>
<tr>
<td>Packaging Size</td>
<td>450×370×290mm</td>
</tr>
</tbody>
</table>
</div>
<h2></h2>
<h2>Optional Microscope Slide Electrodes</h2>
<div class="table-responsive">
<table class="table" border="1" cellspacing="1" cellpadding="1">
<thead>
<tr>
<th>Model</th>
<th>Electrode Distance</th>
<th>Volume</th>
<th>Voltage Range</th>
</tr>
</thead>
<tbody>
<tr>
<td>1－0.5</td>
<td>0.5mm</td>
<td>20µL</td>
<td>0-600V DC</td>
</tr>
<tr>
<td>1－1.0</td>
<td>1.0mm</td>
<td>40µL</td>
<td>0-600V DC</td>
</tr>
<tr>
<td>1－2.0</td>
<td>2.0mm</td>
<td>80µL</td>
<td>0-600V DC</td>
</tr>
<tr>
<td>1－3.2</td>
<td>3.2mm</td>
<td>700µL</td>
<td>0-600V DC</td>
</tr>
<tr>
<td>1-10</td>
<td>10mm</td>
<td>2200µL</td>
<td>0-600V DC</td>
</tr>
</tbody>
</table>
</div>
<h3>Maintenance of Optional Electrodes</h3>
<p>Clean with mild detergent, ethanol, or sterilize via ethylene oxide.</p>
<h2></h2>
<h2>Cell Fusion Induction Methods</h2>
<p>There are three main methods for inducing cell fusion:</p>
<p><strong>Biological Methods (Virus-mediated)</strong>: Viruses such as Sendai virus, parainfluenza virus, and Newcastle disease virus possess fusion proteins that mediate fusion between viruses and host cells, as well as cell-to-cell fusion. Live viruses can be used to induce cell fusion.</p>
<p><strong>Chemical Methods (PEG-mediated)</strong>: Polyethylene glycol (PEG) induces changes in the arrangement of membrane lipid molecules. After removing PEG, the plasma membrane restores its ordered structure, and adjacent cells can fuse during this recovery process.</p>
<p><strong>Physical Methods (Electrical/laser-mediated)</strong>: Electrical excitation or laser treatment disrupts the plasma membrane temporarily, allowing cell fusion when the membrane repairs.</p>
<h2></h2>
<h2>Application Value of Cell Fusion Technology</h2>
<p>Cell fusion technology is not only widely used in basic research but also holds significant practical value:</p>
<p><strong>Plant Breeding</strong>: Successful cultivation of hybrid crops such as radish-cabbage, Nicotiana glauca × Nicotiana langsdorffii, and tomato-potato.</p>
<p><strong>Agriculture, Industry, and Medicine</strong>: Achieved groundbreaking research results, with continuously expanding application fields.</p>
<p><strong>Animal Somatic Hybridization</strong>:</p>
<p>Gene mapping: Correlates the presence/absence of chromosomes or fragments in hybrid cells with trait expression, enabling gene localization. For example, Weise and Green (1967) discovered preferential loss of human chromosomes in human-mouse hybrid cells, facilitating gene mapping on human chromosomes. Ruddle et al. (1970) systematically used fusion cells for human gene mapping.</p>
<h2></h2>
<p>The post <a href="https://keylaser.am/product/cry-3b-laboratory-electric-cell-fusion-system/">CRY-3B Laboratory Electric Cell Fusion System</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Lab Gene Electrophoresis Instrument</title>
		<link>https://keylaser.am/product/lab-gene-electrophoresis-instrument/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Sat, 18 Jul 2026 11:35:08 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=17964</guid>

					<description><![CDATA[<div class="pro-con">The integrated design of the gene electric importer adopts the microcomputer control system, which is simple in operation and intuitive in display. It adopts exponentially decaying pulse form with RC time constant, which can be combined arbitrarily. The experiment log can be stored for easy...</div>
<div class="a2a_kit a2a_kit_size_32 a2a_default_style"></div>
<p>The post <a href="https://keylaser.am/product/lab-gene-electrophoresis-instrument/">Lab Gene Electrophoresis Instrument</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The integrated design of the gene electric importer adopts the microcomputer control system, which is simple in operation and intuitive in display. It adopts exponentially decaying pulse form with RC time constant, which can be combined arbitrarily. The experiment log can be stored for easy searching and calling.</p>
<p>The digital electrophoresis instrument is widely used for cell hybridization, fusion, and gene introduction.</p>
<p><strong> Main Technical Parameters:</strong></p>
<div class="table-responsive">
<table>
<tbody>
<tr class="firstRow">
<td valign="top" width="797"><img decoding="async" title="image" src="https://www.scientzbio.com/Content/upload/2019213197/201907151510157729942.png" alt="image" width="498" height="298" /></td>
</tr>
</tbody>
</table>
</div>
<div class="table-responsive">
<table>
<tbody>
<tr class="firstRow">
<td valign="top" width="797"><img loading="lazy" decoding="async" title="photobank(176)" src="https://www.scientzbio.com/Content/upload/2019213197/201907151513015464672.jpg" alt="photobank(176)" width="773" height="586" /></td>
</tr>
</tbody>
</table>
</div>
<p><strong>Selection of electron electrophoresis instrument</strong></p>
<p>1.0.4 cm pitch electric shock cup: wide spacing, low field strength, applied to mammalian cells and other eukaryotic cells (200ul)</p>
<p>2.0.2 cm pitch electric shock cup: narrow pitch, high field strength, applied to yeast, bacteria and other eukaryotic cells (100ul)</p>
<p>3.0.1 cm pitch electric shock cup: narrowest pitch, very high field strength, shallow bottom for small volume samples (40–80 μl) for yeast and bacterial transformation</p>
<p>4. Strong field electric field strength formula: E=U/d (d is the distance between two points along the field strength direction, electric cup is this formula)</p>
<p>The post <a href="https://keylaser.am/product/lab-gene-electrophoresis-instrument/">Lab Gene Electrophoresis Instrument</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>