<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Drug Testing Instrument Archives - Keylaser Armenia</title>
	<atom:link href="https://keylaser.am/product-category/scientz/drug-testing-instrument/feed/" rel="self" type="application/rss+xml" />
	<link>https://keylaser.am/product-category/scientz/drug-testing-instrument/</link>
	<description>Medical, laboratory, scientific, cosmetology, hair removal and SPA devices in Armenia</description>
	<lastBuildDate>Thu, 09 Jul 2026 14:01:15 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.5</generator>

<image>
	<url>https://keylaser.am/wp-content/uploads/2022/04/500x500-100x100.png</url>
	<title>Drug Testing Instrument Archives - Keylaser Armenia</title>
	<link>https://keylaser.am/product-category/scientz/drug-testing-instrument/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Dissolution Tester</title>
		<link>https://keylaser.am/product/dissolution-tester/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Thu, 09 Jul 2026 14:01:15 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=17020</guid>

					<description><![CDATA[<div class="pro-con">Features 1. High precision dissolution cup All parameters of the high precision and satisfactory dissolution cup meet the requirements of the Chinese pharmacopoeia. 2. Automatic dosage Automatic dosing can be realized, including automatic synchronous dosing and automatic sequence dosing, so as...</div>
<p>The post <a href="https://keylaser.am/product/dissolution-tester/">Dissolution Tester</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features</strong></p>
<p>1. High precision dissolution cup</p>
<p>All parameters of the high precision and satisfactory dissolution cup meet the requirements of the Chinese pharmacopoeia.</p>
<p>2. Automatic dosage</p>
<p>Automatic dosing can be realized, including automatic synchronous dosing and automatic sequence dosing, so as to facilitate users in different ways of use.</p>
<p>3.  Solvent temperature monitoring</p>
<p>The temperature monitoring system can monitor the temperature of solvent in real time or at sampling time. Synchronously monitor the temperature of the rehydration solution and realize isothermal rehydration.</p>
<p>4. Influence of cover</p>
<p>Avoid solvent evaporation and cross contamination</p>
<p>5. The sampling point is automatically positioned</p>
<p>According to the set method and the volume of the solvent, the height of sampling point can be automatically determined with high precision and fast speed.</p>
<p>6. Biometric identification technology</p>
<p>Capacitive fingerprint recgnition system can recognize the user&#8217;s identity,avoiding the user name password login tedious,easy to use.</p>
<p>7. Magnetic induction water flow sensor</p>
<p>The water flow sensor of magnetic induction technology is adopted to monitor the water flow in the circulating pipeline, so as to ensure no dry burning and more reliable.</p>
<p>8. Built-in permission management system</p>
<p>The three-level permission management system is adopted, which is divided into guest account, ordinary account and administrator account. Different permissions are assigned to different accounts.</p>
<p>9. Electric lifting head</p>
<p>Electric lifting head, double positioning cone positioning, patented technology, adjustable head fixing structure. Make sure the cup plate is parallel to the machine head and the instrument parameters are stable and reliable.</p>
<p>10. Quick disassembly system for dissolving cups</p>
<p>Dissolve the cup holder and cup holder ring can be disassembled quickly,and can be adjusted to 360°,it&#8217;s easy and convenient to use.</p>
<p>11. Removable control box</p>
<p>The control box can be repaired without moving the host machine during maintenance, and no mechanical correction is required.</p>
<p>12. Normally closed temperature switch</p>
<p>Adopted normally closed temperature switches, power automatically cut when temperature more than 55 ℃, safe and reliable.</p>
<p>RC810G/RC1210G</p>
<p><strong>Parameters</strong></p>
<p>1. The experiments of basket method, paddle method, cup method, plate method (large and small plate ) and drum method (long and short tube) can be carried out to meet the requirements of blank and contrast.</p>
<p>2. Motor head electric lifting</p>
<p>3. Self-aligning clutch</p>
<p>4. Simultaneous drug and sequence</p>
<p>5. Dual color lighting system</p>
<p>6. Multi-user management</p>
<p>7. Wifi, bluetooth, RS232, RS485 extension interface</p>
<p>8. Biometric identification technology</p>
<p>9. Built-in printer</p>
<p>10.  High sensitivity capacitive touch screen</p>
<p>11.  Authority management</p>
<p>12. Audit trails</p>
<p><strong>Technical indicators</strong></p>
<div class="table-responsive">
<table cellspacing="0">
<tbody>
<tr class="firstRow">
<td>Test unit number</td>
<td>8/12+2</td>
</tr>
<tr>
<td>Water bath temperature</td>
<td>Indoor temperature-45℃</td>
</tr>
<tr>
<td>Temperature resolution</td>
<td>0.01℃</td>
</tr>
<tr>
<td>Stirring speed</td>
<td>25RPM-250RPM</td>
</tr>
<tr>
<td>Stirring speed resolution</td>
<td>0.01RPM</td>
</tr>
<tr>
<td>Drug channel</td>
<td>8/12</td>
</tr>
<tr>
<td>Machine head lifting mode</td>
<td>Electric</td>
</tr>
<tr>
<td>Illuminating system</td>
<td>White light, red light</td>
</tr>
<tr>
<td>Number of users</td>
<td>7</td>
</tr>
<tr>
<td>User level</td>
<td>3</td>
</tr>
<tr>
<td>User program</td>
<td>99</td>
</tr>
<tr>
<td>Record keeping</td>
<td>128*366days</td>
</tr>
</tbody>
</table>
<p><strong>RC810</strong></div>
<p><strong>Parameters</strong></p>
<p>1. The experiments of basket method, paddle method, cup method, plate method (large and small plate ) and drum method (long and short tube) can be carried out to meet the requirements of blank and contrast.</p>
<p>2. Motor head electric lifting</p>
<p>3. Self-aligning clutch</p>
<p>4. Simultaneous drug and sequence</p>
<p>5. Multi-user management</p>
<p>6. Authority management</p>
<p>7. Audit trails</p>
<p><strong>Technical indicators</strong></p>
<div class="table-responsive">
<table cellspacing="0">
<tbody>
<tr class="firstRow">
<td>Test unit number</td>
<td>8</td>
</tr>
<tr>
<td>Water bath temperature</td>
<td>Indoor temperature-45℃</td>
</tr>
<tr>
<td>Temperature resolution</td>
<td>0.01℃</td>
</tr>
<tr>
<td>Stirring speed</td>
<td>25RPM-250RPM</td>
</tr>
<tr>
<td>Stirring speed resolution</td>
<td>0.01RPM</td>
</tr>
<tr>
<td>Drug channel</td>
<td>8</td>
</tr>
<tr>
<td>Machine head lifting mode</td>
<td>Electric</td>
</tr>
<tr>
<td>Number of users</td>
<td>7</td>
</tr>
<tr>
<td>User level</td>
<td>3</td>
</tr>
<tr>
<td>User program</td>
<td>99</td>
</tr>
<tr>
<td>Record keeping</td>
<td>128*366days</td>
</tr>
</tbody>
</table>
</div>
<p><strong>RC801S/RC1210S</strong></p>
<p><strong>Parameters</strong></p>
<p>1. The experiments of basket method, paddle method, cup method, plate method (large and small plate ) and drum method (long and short tube) can be carried out to meet the requirements of blank and contrast.</p>
<p>2. Motor head electric lifting</p>
<p>3. Electric lifting of sampling frame</p>
<p>4. Self-aligning clutch</p>
<p>5. Automatic and independent drug delivery</p>
<p>6. Dual color lighting system</p>
<p>7. Multi-user management</p>
<p>8. Wifi, bluetooth, RS232, RS485 extension interface</p>
<p>9. Biometric identification technology</p>
<p>10. Built-in printer</p>
<p>11. Solvent monitoring</p>
<p>12. Stirring speed monitoring</p>
<p>13. Multi-user management</p>
<p>14. Connect with the prototype</p>
<p>15. High sensitivity capacitive touch screen</p>
<p>16. Authority management</p>
<p>17. Audit trails</p>
<p><strong>Technical indicators</strong></p>
<div class="table-responsive">
<table>
<tbody>
<tr class="firstRow">
<td>Test unit number</td>
<td>8/12+2</td>
</tr>
<tr>
<td>Water bath temperature</td>
<td>Indoor temperature-45℃</td>
</tr>
<tr>
<td>Solvent temperature monitoring</td>
<td>8/14 channel</td>
</tr>
<tr>
<td>Temperature resolution</td>
<td>0.01℃</td>
</tr>
<tr>
<td>Stirring speed</td>
<td>25RPM-250RPM</td>
</tr>
<tr>
<td>Stirring speed resolution</td>
<td>0.01RPM</td>
</tr>
<tr>
<td>Drug channel</td>
<td>8/12</td>
</tr>
<tr>
<td>Machine head lifting mode</td>
<td>Electric</td>
</tr>
<tr>
<td>Lifting mode of sampling frame</td>
<td>Electric,automatic</td>
</tr>
<tr>
<td>Sample point resolution</td>
<td>1ml</td>
</tr>
<tr>
<td>Illuminating system</td>
<td>White light, red light</td>
</tr>
<tr>
<td>Number of users</td>
<td>7</td>
</tr>
<tr>
<td>User level</td>
<td>3</td>
</tr>
<tr>
<td>User program</td>
<td>99</td>
</tr>
<tr>
<td>Record keeping</td>
<td>128*366days</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://keylaser.am/product/dissolution-tester/">Dissolution Tester</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Intelligent Disintegrator</title>
		<link>https://keylaser.am/product/intelligent-disintegrator/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Thu, 09 Jul 2026 13:59:01 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=17016</guid>

					<description><![CDATA[<div class="pro-con">Features: 1. Capacitive touch screen High sensitivity color LCD capacitive touch screen, clear color, smooth operation and detailed display. Toughened glass screen, durable, high transparency. 2. One-body water bath Adopt the injection molding integrated PC water bath, no circulation dead Angle,...</div>
<p>The post <a href="https://keylaser.am/product/intelligent-disintegrator/">Intelligent Disintegrator</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<p>1. Capacitive touch screen</p>
<p>High sensitivity color LCD capacitive touch screen, clear color, smooth operation and detailed display. Toughened glass screen, durable, high transparency.</p>
<p>2. One-body water bath</p>
<p>Adopt the injection molding integrated PC water bath, no circulation dead Angle, high strength, high temperature resistance, easy to clean, the deficiency of PMMA in strength, temperature and life was avoided.</p>
<p>3. Illuminating system</p>
<p>With a patented lighting system of 1, it is convenient to observe the sample disintegration, and the fog surface is astigmatized to avoid stimulating the user&#8217;s vision, while illuminating the entire beaker.</p>
<p>4. Quickly remove and install the hanging basket card</p>
<p>With patent 2, it can quickly disassemble and install and adjust the height of the hanging basket card, which integrates positioning, height adjustment, fastening and a whole body. It can realize the quick reading and dismounting of the hanging basket, which is convenient and practical.</p>
<p>5. Full size screen</p>
<p>Provide 2mm, equipped with 1mm, 0.71mm, and 0.42mm sieve mesh are selected to meet different user&#8217;s requirements.</p>
<p>6. High precision temperature sensor</p>
<p>German imports of 1/3 b (highest level) and high precision Pt1000 platinum resistance temperature sensor, good linear, low temperature drift, quick response, high precision, at the same time using ptfe sheathed with temperature compensation, super soft, pure copper, silver, high temperature resistant AFR250 cable. The water bath temperature can be feedback more quickly and accurately.</p>
<p>7. Inside the cup correction</p>
<p>The temperature correction in the cup is adopted to avoid the error caused by the temperature correction in the tank of the traditional caving instrument.</p>
<p><strong>Parameters</strong></p>
<p>1. Three baskets disintegration time detection system</p>
<p>2. High precision PT1000 temperature sensor</p>
<p>3. Temperature correction in cup</p>
<p>4. The test time can be adjusted</p>
<p>5. Real-time display of time temperature</p>
<p>6. Overheating protection</p>
<p>7. Integral water bath box, no water bath circulation dead Angle, easy to clean</p>
<p>8. Overall appearance design, high &#8211; grade simplicity</p>
<p>9. Independent lighting system</p>
<p>10. Voice prompt</p>
<p>11. One-piece, quick removal of hanging basket card</p>
<p>12. High sensitivity capacitive touch screen</p>
<p>13. Authority management</p>
<p>14. Audit trails</p>
<p><strong>Technical indicators</strong></p>
<div class="table-responsive">
<table cellspacing="0">
<tbody>
<tr class="firstRow">
<td>Temperature range</td>
<td>Indoor temperature-45℃</td>
</tr>
<tr>
<td>Temperature resolution</td>
<td>0.01℃</td>
</tr>
<tr>
<td>Number of hanging basket</td>
<td>3</td>
</tr>
<tr>
<td>Lift frequency</td>
<td>30-32 times/min</td>
</tr>
<tr>
<td>Lifting distance</td>
<td>55mm±1mm</td>
</tr>
<tr>
<td>Spacing between bottom and bottom of screen</td>
<td>25mm±2mm</td>
</tr>
<tr>
<td>Mesh size</td>
<td>2mm, optional 1mm,0.71mm,0.42mm</td>
</tr>
<tr>
<td>Block density</td>
<td>1.18-1.2g/cm</td>
</tr>
<tr>
<td>Number of users</td>
<td>7</td>
</tr>
<tr>
<td>User level</td>
<td>3</td>
</tr>
<tr>
<td>Record keeping</td>
<td>96*366days</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://keylaser.am/product/intelligent-disintegrator/">Intelligent Disintegrator</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Degassing Apparatus</title>
		<link>https://keylaser.am/product/degassing-apparatus/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Thu, 09 Jul 2026 13:57:24 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=17012</guid>

					<description><![CDATA[<div class="pro-con">TQ01 Degassing apparatus was developed according to the Chinese pharmacopoeia, which is used for the degassing with water in the early stage of the measurment of dissolution and releasing rate of solid preparation. The apparatus adopts degassing membrane to degassing, and adopts Dc brushless...</div>
<p>The post <a href="https://keylaser.am/product/degassing-apparatus/">Degassing Apparatus</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Degassing apparatus was developed  according to the Chinese pharmacopoeia, which is used for the degassing with water in the early stage of the measurment of dissolution and releasing rate of solid preparation. The apparatus adopts degassing membrane to degassing, and adopts Dc brushless vacuum pump and water pump, with the advantages of good degassing effect and low noise, the degassing and heating of pure water also can be completed.</p>
<p><strong>◣Features:</strong></p>
<p>1. Membrane filtration degassing method</p>
<p>The filtration membrane adopts special materials, the filter aperture is as low as 0.01μm~0.2μm, single membrane filtration area can be reached 15㎡,degassing rate can be reached 95% and high filtration efficiency.</p>
<p>2. Handheld sample gun</p>
<p>Patented technology,tape terminal display,controlled sample gun. It can  set parameters of velocity ,volume etc. not only on the mainframe but also on the sample gun,it&#8217;s convenience to use.</p>
<p>3. Biometric identification technology</p>
<p>Capacitive fingerprint recgnition system can recognize the user&#8217;s identity,avoiding the user name password login tedious,easy to use.</p>
<p>4. PWM heating control</p>
<p>Adopt PWM heating control technology,zero-cross SSR and mechanical relay composite control, it not only avoids the interference and reduction of service life caused by switching on and off of single mechanical relay at the wave peak, but also ensures the leakage of power of single solid state relay.Safer and more reliable.</p>
<p><strong>◣Parameters:</strong></p>
<p>1. The filter membrane degasses online and has high efficiency.</p>
<p>2. Micro &#8211; dc brushless vacuum pump,the negative pressure value can reach to 98Kpa, low noise,long service life.</p>
<p>3. Micro-dc brushless regulate integrated miniature water pump, unpulsation of water,real-time traffic feedback,low noise,long service life.</p>
<p>4. Low power high efficiency heating system, adopt normal AC220V10 power interface.</p>
<p>5. Handheld ,adjustable flow sample gun.</p>
<p>6. Electronic scale quantitative system,high quantity accuracy.</p>
<p>7. Multi-user management.</p>
<p><strong>◣Technical indicators</strong></p>
<div class="table-responsive">
<table cellspacing="0">
<tbody>
<tr class="firstRow">
<td>Vacuum degree</td>
<td>98Kpa (highest)</td>
</tr>
<tr>
<td>Velocity regulating</td>
<td>30%-100%</td>
</tr>
<tr>
<td>Heating power</td>
<td>1500W</td>
</tr>
<tr>
<td>Volume of quantitative</td>
<td>15L</td>
</tr>
<tr>
<td>Quantitative accuracy</td>
<td>10L±1%</td>
</tr>
<tr>
<td>Number of users</td>
<td>7</td>
</tr>
<tr>
<td>User level</td>
<td>3</td>
</tr>
<tr>
<td>User program</td>
<td>99</td>
</tr>
<tr>
<td>Recording keep</td>
<td>128*366 days</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://keylaser.am/product/degassing-apparatus/">Degassing Apparatus</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Drug Friability Tester</title>
		<link>https://keylaser.am/product/drug-friability-tester/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Thu, 09 Jul 2026 13:55:32 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=17008</guid>

					<description><![CDATA[<div class="pro-con">CS-2 Tablet Friability Tester For Lab Use CS-2 Tablet Friability Tester For Lab Use The Friability Tester is used to test the physical strength of the uncoated tablets such as crushing strength, etc. Features: It has single way and double barrels which circulate at the same time; Timing power off automatically. The cylinder adopts high grade colorless transparent lucite. You can preset the parameter of speed and turn number optionally; timesharing shows the preset value and real-time value. Full-automatic intellectuality control the speed and the turning number of the cylinder with a high control precision. The automation: automatic test, automatic diagnosis, automatic alarm.</div>
<div class="a2a_kit a2a_kit_size_32 a2a_default_style"></div>
<p>The post <a href="https://keylaser.am/product/drug-friability-tester/">Drug Friability Tester</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<p><strong>Product Description</strong></p>
<p>TFT-1 Tablet Friability Tester For Lab Use</p>
<p>The Friability Tester is used to test the physical strength of the uncoated tablets such as crushing strength, etc.</p>
<p><strong>Features:</strong></p>
<p>It has single way and double barrels which circulate at the same time; Timing power off automatically.<br />
The cylinder adopts high grade colorless transparent lucite.<br />
You can preset the parameter of speed and turn number optionally; timesharing shows the preset value and real-time value.<br />
Full-automatic intellectuality control the speed and the turning number of the cylinder with a high control precision.<br />
The automation: automatic test, automatic diagnosis, automatic alarm.</p>
<p><img fetchpriority="high" decoding="async" title="product-275-275" src="https://www.scientzbio.com/Content/uploads/2022213197/202207181459075b925ba66b0c41bd8accb837e63320d1.png" alt="Digital friability test apparatusTFT-1" width="275" height="275" /></p>
<div id="ali-anchor-AliPostDhMb-w25ei">
<div>
<p><img decoding="async" title="product-710-31" src="https://www.scientzbio.com/Content/upload/2022213197/202207181458564063111.jpgquality=close.jpg" alt="CS-2 Tablet Friability Tester For Lab Use" width="710" height="31" /></p>
</div>
</div>
<p>CS-2 Tablet Friability Tester For Lab Use</p>
<div class="table-responsive">
<table class="aliDataTable" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr class="firstRow">
<td>Quantity of the turnplate cylinder:</td>
<td>2</td>
</tr>
<tr>
<td>Interior Diameter of the turnplate cylinder:</td>
<td> Φ286mm</td>
</tr>
<tr>
<td>Depth of the turnplate cylinder:</td>
<td> 39mm</td>
</tr>
<tr>
<td>Sliding height of the drug:</td>
<td>156mm</td>
</tr>
<tr>
<td>Scope of rotating speed:</td>
<td>25 circles/min</td>
</tr>
<tr>
<td>Precision of rotating speed:</td>
<td>±1 circle/min</td>
</tr>
<tr>
<td>Scope of rotating circle quantity:</td>
<td>100circles</td>
</tr>
<tr>
<td>Precision of rotating circle quantity:</td>
<td> ±1 circle</td>
</tr>
<tr>
<td>Continuous working time:</td>
<td>&gt;24 hours</td>
</tr>
<tr>
<td>Power supply:</td>
<td>220V 50Hz 40W</td>
</tr>
<tr>
<td>Overall dimension:</td>
<td>37x30x34cm</td>
</tr>
<tr>
<td>Weight:</td>
<td>11kg</td>
</tr>
</tbody>
</table>
</div>
<p>&nbsp;</p>
<p>The post <a href="https://keylaser.am/product/drug-friability-tester/">Drug Friability Tester</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Drug Dissolution Apparatus</title>
		<link>https://keylaser.am/product/drug-dissolution-apparatus/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Thu, 09 Jul 2026 13:49:05 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=17000</guid>

					<description><![CDATA[<div class="pro-con">Providing a mechatronics test device controlled by a microcomputer for dissolution measurement, mainly composed of an electric motor, a thermostat, a basket, a stirring paddle, a dissolution cup and a cup cover Technical indicators： RC810G Dissolution tester QY8 Sampler</div>
<div class="a2a_kit a2a_kit_size_32 a2a_default_style"></div>
<p>The post <a href="https://keylaser.am/product/drug-dissolution-apparatus/">Drug Dissolution Apparatus</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Providing a mechatronics test device controlled by a microcomputer for dissolution measurement, mainly composed of an electric motor, a thermostat, a basket, a stirring paddle, a dissolution cup and a cup cover</p>
<p><strong>Technical indicators：</strong></p>
<p><strong>RC810G Dissolution tester</strong></p>
<div class="table-responsive">
<table border="1" cellspacing="0">
<tbody>
<tr class="firstRow">
<td>Model</td>
<td>RC810G</td>
</tr>
<tr>
<td>Number of experimental devices</td>
<td>8</td>
</tr>
<tr>
<td>Water bath temperature</td>
<td>Room temperature-45℃</td>
</tr>
<tr>
<td>Temperature resolution</td>
<td>0.01℃</td>
</tr>
<tr>
<td>Stirring speed</td>
<td>25RPM-250RPM</td>
</tr>
<tr>
<td>Stirring speed resolution</td>
<td>0.1RPM</td>
</tr>
<tr>
<td>Dosing channel</td>
<td>8</td>
</tr>
<tr>
<td>Head lift</td>
<td>electric</td>
</tr>
<tr>
<td>Lighting system</td>
<td>Red light, white light</td>
</tr>
<tr>
<td>amount of users</td>
<td>7users</td>
</tr>
<tr>
<td>user level</td>
<td>Third level</td>
</tr>
<tr>
<td>User program</td>
<td>99</td>
</tr>
<tr>
<td>Record saving</td>
<td>128 *366 days</td>
</tr>
</tbody>
</table>
</div>
<p>QY8 Sampler</p>
<div class="table-responsive">
<table border="1" cellspacing="0">
<tbody>
<tr class="firstRow">
<td>Model</td>
<td>QY8</td>
</tr>
<tr>
<td>Sampling channel</td>
<td>8</td>
</tr>
<tr>
<td>Number of samples</td>
<td>16</td>
</tr>
<tr>
<td>Longest sampling interval</td>
<td>99 hours 59 minutes</td>
</tr>
<tr>
<td>Minimum sampling interval</td>
<td>1 minute for the first time, the remaining 2-10 minutes (depending on the sample size, sampling method and whether it is rehydration)</td>
</tr>
<tr>
<td>Continuous working time</td>
<td>99 hours 59 minutes × 16</td>
</tr>
<tr>
<td>Sampling filter cycle</td>
<td>&lt;30 seconds</td>
</tr>
<tr>
<td>Sample volume (or fluid volume)</td>
<td>1ml-100ml</td>
</tr>
<tr>
<td>Single tube distribution</td>
<td>0ml-15ml</td>
</tr>
<tr>
<td>Sampling accuracy</td>
<td>RSD1%(10ml)</td>
</tr>
<tr>
<td>User program</td>
<td>99</td>
</tr>
<tr>
<td>amount of users</td>
<td>7 users</td>
</tr>
<tr>
<td>user level</td>
<td>Third level</td>
</tr>
<tr>
<td>Record saving</td>
<td>128 *366 days</td>
</tr>
</tbody>
</table>
</div>
<p><img decoding="async" title="product-802-531" src="https://www.scientzbio.com/Content/upload/2018213197/201812250938348532083.jpg" alt="RQ810" width="802" height="531" /></p>
<p>&nbsp;</p>
<p><img loading="lazy" decoding="async" title="product-792-565" src="https://www.scientzbio.com/Content/upload/2018213197/201812250942306098948.jpg" alt="8L9A9468" width="792" height="565" /></p>
<p><img loading="lazy" decoding="async" title="product-794-632" src="https://www.scientzbio.com/Content/upload/2018213197/201812250944195976094.jpg" alt="8L9A9463" width="794" height="632" /></p>
<p>The post <a href="https://keylaser.am/product/drug-dissolution-apparatus/">Drug Dissolution Apparatus</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Tablet Dissolution Tester</title>
		<link>https://keylaser.am/product/tablet-dissolution-tester/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Thu, 09 Jul 2026 13:46:33 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=16992</guid>

					<description><![CDATA[<div class="pro-con">Dissolution Refers to the rate and extent to which active pharmaceutical ingredients are dissolved from a formulation such as a tablet, capsule or granule under specified conditions. It is an indicator for evaluating the quality of oral solid preparations of drugs, and is an in vitro simple test...</div>
<div class="a2a_kit a2a_kit_size_32 a2a_default_style"></div>
<p>The post <a href="https://keylaser.am/product/tablet-dissolution-tester/">Tablet Dissolution Tester</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Dissolution</strong></p>
<p>Refers to the rate and extent to which active pharmaceutical ingredients are dissolved from a formulation such as a tablet, capsule or granule under specified conditions. It is an indicator for evaluating the quality of oral solid preparations of drugs, and is an in vitro simple test method for simulating disintegration and dissolution of oral solid preparations in the gastrointestinal tract.</p>
<p><strong>Dissolution assay</strong></p>
<p>Place a certain amount of a certain preparation in the basket (dissolution cup) of the dissolution apparatus, operate at a constant temperature of 37 ° C ± 0.5 ° C, operate at a specified speed and dissolution medium, sample and determine the dissolution within a specified time. the amount.</p>
<p><img loading="lazy" decoding="async" title="product-777-617" src="https://www.scientzbio.com/Content/upload/2018213197/201812251031353053065.jpg" alt="8L9A9325" width="777" height="617" /></p>
<p>The post <a href="https://keylaser.am/product/tablet-dissolution-tester/">Tablet Dissolution Tester</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Medical Dissolution Tester Equipment</title>
		<link>https://keylaser.am/product/medical-dissolution-tester-equipment/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Thu, 09 Jul 2026 13:44:10 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=16984</guid>

					<description><![CDATA[<p>RQ810S is composed of RC810S dissolution tester connected to QY8 sampler. It has granule dosage, solvent temperature monitoring, automatic sampling point, and 30 seconds filtration capacity greater than 10ml. Its performance indicators are in full compliance with the requirements of the Chinese...</p>
<p>The post <a href="https://keylaser.am/product/medical-dissolution-tester-equipment/">Medical Dissolution Tester Equipment</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>RQ810S is composed of RC810S dissolution tester connected to QY8 sampler. It has granule dosage, solvent temperature monitoring, automatic sampling point, and 30 seconds filtration capacity greater than 10ml. Its performance indicators are in full compliance with the requirements of the Chinese Pharmacopoeia (2015 edition) and the &#8220;Guidelines for Mechanical Calibration of Dissolution Testers&#8221;.</p>
<p><img decoding="async" title="product-1-1" src="https://www.scientzbio.com/Content/upload/2018213197/201812251527004784228.png" alt="image" /></p>
<p>&nbsp;</p>
<p><img loading="lazy" decoding="async" title="product-727-468" src="https://www.scientzbio.com/Content/upload/2018213197/201812251527387841092.png" alt="image" width="727" height="468" /></p>
<p><img loading="lazy" decoding="async" title="product-1-1" src="https://www.scientzbio.com/Content/upload/2018213197/201812251528512030710.png" alt="image" width="1" height="1" /><img loading="lazy" decoding="async" title="product-728-528" src="https://www.scientzbio.com/Content/upload/2018213197/201812251529171896917.png" alt="image" width="728" height="528" /></p>
<p>The post <a href="https://keylaser.am/product/medical-dissolution-tester-equipment/">Medical Dissolution Tester Equipment</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Tablet Hardness Tester</title>
		<link>https://keylaser.am/product/tablet-hardness-tester/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Thu, 09 Jul 2026 13:41:37 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=16978</guid>

					<description><![CDATA[<div class="pro-con">The smart tablet hardness tester is a drug test instrument for measuring the hardness of a tablet. Tablets should have suitable hardness to avoid breakage or wear during packaging and transportation. Therefore, tablet hardness is an important indicator reflecting the level of tablet production...</div>
<div class="a2a_kit a2a_kit_size_32 a2a_default_style"></div>
<p>The post <a href="https://keylaser.am/product/tablet-hardness-tester/">Tablet Hardness Tester</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The smart tablet hardness tester is a drug test instrument for measuring the hardness of a tablet. Tablets should have suitable hardness to avoid breakage or wear during packaging and transportation. Therefore, tablet hardness is an important indicator reflecting the level of tablet production technology and controlling the quality of tablets. Correctly reflecting and testing the hardness of the tablet has important practical guiding significance for the production and research of the tablet and the accuracy of the clinical drug.</p>
<p><strong>Performance characteristics:</strong></p>
<p>1. Interface two-wire redundancy design</p>
<p>The 10 interface adopts two-wire parallel design to ensure stable and reliable operation under the condition that 50% of the terminals are connected.</p>
<p><strong>Function parameter</strong></p>
<p>1. High sensitivity capacitive touch screen</p>
<p>2. Authority management</p>
<p>3. Audit trail</p>
<div class="table-responsive">
<table>
<tbody>
<tr class="firstRow">
<td colspan="2" rowspan="1"><strong>Technical indicators</strong></td>
</tr>
<tr>
<td>Amount of users</td>
<td>7users</td>
</tr>
<tr>
<td>User level</td>
<td>Third level</td>
</tr>
<tr>
<td>Record saving</td>
<td>128 *366 days</td>
</tr>
</tbody>
</table>
</div>
<p><img decoding="async" title="product-1-1" src="https://www.scientzbio.com/Content/upload/2019213197/201902201303439965382.png" alt="硬度仪" /></p>
<p>The post <a href="https://keylaser.am/product/tablet-hardness-tester/">Tablet Hardness Tester</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Tablet Disintegration Instrument</title>
		<link>https://keylaser.am/product/tablet-disintegration-instrument/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Thu, 09 Jul 2026 13:38:36 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=16971</guid>

					<description><![CDATA[<div class="pro-con">High-precision tablet disintegration instrument complies with the new version of the Pharmacopoeia and is widely used in pharmaceutical companies, drug testing institutes, etc. Technical Parameters</div>
<div class="a2a_kit a2a_kit_size_32 a2a_default_style"></div>
<p>The post <a href="https://keylaser.am/product/tablet-disintegration-instrument/">Tablet Disintegration Instrument</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="ast-oembed-container " style="height: 100%;"><iframe loading="lazy" title="ZBJ01 Disintegration Apparatus" width="1778" height="1000" src="https://www.youtube.com/embed/POdaDzQfiV4?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
<p>High-precision tablet disintegration instrument complies with the new version of the Pharmacopoeia and is widely used in pharmaceutical companies, drug testing institutes, etc.</p>
<p><strong>Technical Parameters</strong></p>
<div class="table-responsive">
<table border="1" cellspacing="0">
<tbody>
<tr class="firstRow">
<td>Model</td>
<td>ZBJ01</td>
</tr>
<tr>
<td>Temperature range</td>
<td>Room-45℃</td>
</tr>
<tr>
<td>Temperature resolution</td>
<td>0.01℃</td>
</tr>
<tr>
<td>Number of baskets</td>
<td>3 cups</td>
</tr>
<tr>
<td>Lifting frequency</td>
<td>30-32 times / minute</td>
</tr>
<tr>
<td>Lifting distance</td>
<td>55mm±1mm</td>
</tr>
<tr>
<td>Screen bottom distance from the bottom of the cup</td>
<td>25mm±2mm</td>
</tr>
<tr>
<td>Screen aperture</td>
<td>2mm</p>
<p>Optional 1mm, 0.71mm, 0.42mm</td>
</tr>
<tr>
<td>Stop density</td>
<td>1.18-1.20g/c㎡</td>
</tr>
<tr>
<td>Amount of users</td>
<td>7 users</td>
</tr>
<tr>
<td>User level</td>
<td>Third level</td>
</tr>
<tr>
<td>Record saving</td>
<td>96 *366 days</td>
</tr>
</tbody>
</table>
</div>
<div class="table-responsive">
<table>
<tbody>
<tr class="firstRow">
<td><img loading="lazy" decoding="async" title="product-802-745" src="https://www.scientzbio.com/Content/upload/2019213197/201902201336467747243.jpg" alt="8L9A9245" width="802" height="745" /></td>
</tr>
<tr>
<td colspan="1" rowspan="1"><img loading="lazy" decoding="async" title="product-813-452" src="https://www.scientzbio.com/Content/upload/2019213197/201902201340465697413.png" alt="image" width="813" height="452" /></td>
</tr>
<tr>
<td colspan="1" rowspan="1">Capacitive touch screen</td>
</tr>
<tr>
<td colspan="1" rowspan="1"><img loading="lazy" decoding="async" title="product-812-536" src="https://www.scientzbio.com/Content/upload/2019213197/201902201341443525984.png" alt="image" width="812" height="536" /></td>
</tr>
<tr>
<td colspan="1" rowspan="1">Integrated sink lighting</td>
</tr>
<tr>
<td><img loading="lazy" decoding="async" title="product-810-538" src="https://www.scientzbio.com/Content/upload/2019213197/201902201343227739890.png" alt="image" width="810" height="538" /></td>
</tr>
<tr>
<td colspan="1" rowspan="1">Quick disassembly of the hanging basket card</td>
</tr>
<tr>
<td colspan="1" rowspan="1"><img loading="lazy" decoding="async" title="product-813-543" src="https://www.scientzbio.com/Content/upload/2019213197/201902201344285618322.png" alt="image" width="813" height="543" /></td>
</tr>
<tr>
<td colspan="1" rowspan="1">Full specification screen</td>
</tr>
</tbody>
</table>
</div>
<p>&nbsp;</p>
<p>The post <a href="https://keylaser.am/product/tablet-disintegration-instrument/">Tablet Disintegration Instrument</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Tablet Dissolution Apparatus</title>
		<link>https://keylaser.am/product/tablet-dissolution-apparatus/</link>
		
		<dc:creator><![CDATA[Naren Hakobyan]]></dc:creator>
		<pubDate>Thu, 09 Jul 2026 13:34:49 +0000</pubDate>
				<guid isPermaLink="false">https://keylaser.am/?post_type=product&#038;p=16963</guid>

					<description><![CDATA[<div class="pro-con">Dissolution : refers to the rate and extent to which a drug is dissolved from a solid preparation such as a tablet in a predetermined solvent. Dissolution is an important indicator of tablet quality control, and poorly soluble drugs should generally be tested for dissolution . For formulations...</div>
<div class="a2a_kit a2a_kit_size_32 a2a_default_style"></div>
<p>The post <a href="https://keylaser.am/product/tablet-dissolution-apparatus/">Tablet Dissolution Apparatus</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Dissolution: refers to the rate and extent to which a drug is dissolved from a solid preparation such as a tablet in a predetermined solvent. Dissolution is an important indicator of tablet quality control, and poorly soluble drugs should generally be tested for dissolution. For formulations that check for dissolution, the time limit for disintegration is not checked.</p>
<p>The dissolution tester consists of a cabinet, control system, electrical system, water bath system, transmission system, sensors, paddle components, and basket components.</p>
<div class="ast-oembed-container " style="height: 100%;"><iframe loading="lazy" title="Tablet dissolution apparatus installation vedio" width="1778" height="1000" src="https://www.youtube.com/embed/bmi5wyStdpc?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></div>
<p>The post <a href="https://keylaser.am/product/tablet-dissolution-apparatus/">Tablet Dissolution Apparatus</a> appeared first on <a href="https://keylaser.am">Keylaser Armenia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
