Tablet-capsule-laboratory-dissolution-testing

Dissolution 1. It can realize the test of basket method, paddle method, small cup method, dish method (large and small dish), and drum method (long and short tube) to meet the requirements of blank and control.

Item 1  Dissolution RC810 (MDS-2008DS)

Model noMDS-2008DS

Dissolution

1. It can realize the test of basket method, paddle method, small cup method, dish method (large and small dish), and drum method (long and short tube) to meet the requirements of blank and control.

2. The machine head is electrically lifted.

3. The sampling frame is electrically lifted.

4. Automatically set the clutch.

5. Automatic, independent drug administration.

6. Two-color lighting system.

7. Multi-user management.

8. WiFi, Bluetooth, RS232, RS485 expansion interface.

9. Built-in printer.

101. Solvent monitoring.

11. Stirring speed monitoring.

12. Multi-user management.

13. Connect to the sampler.

15. High sensitivity capacitive touch screen.

16. Rights management.

17. Audit trail.

Technical spec :

Model MDS-2008DS
Cup 8
Bath Temperature RT-45℃
Solvent temperature detection 8 channels
Temperature resolution 0.01℃
Stirring speed 25RPM-250RPM
Stirring speed resolution 0.1RPM
Dosing channel 8
Head lift method Electrical method
Head lift method Electrical method
Sample point resolution 1ml
Lighting system Red ligh/White light
Number of user 7 users
User lever 3 class
Progrma 99
Record keeping 128 items *366 days

4

Item 2 Sampling Model no QY8

2

Description   

1. Use a precision glass syringe as the sampling power.

2. 2. Adopt high precision, high pressure and high chemical stability valve body.

3. 3. Built-in micro printer.

4. 4. Multi-user management.

5. 5. WiFi, Bluetooth, RS232, RS485 expansion interface 1.

6. 6. The internal use of high chemical stability of the Teflon pipeline.

7. 7. Has the same amount of rehydration function.

8. 8. With independent pipeline system, it can meet the control requirements of blank  and standard for dissolution test.

9. 9. A cylindrical filter head with a pore size of 10 μm was sampled at the initial    filtration, and a φ25 mm syringe filter having a pore size of 0.8 μm/0.45 μm/0.22 μm was selected as needed for the secondary filtration.A 11.16-bit test tube rack can hold up to 192 tubes.

10. 10. The sampling tube is equipped with a silicone cap to prevent evaporation and   contamination of the sample.

11. 11. Can be operated online with the dissolution apparatus.

12. 12. Ampoule collection device.

13. 13. High sensitivity capacitive touch screen.

14. 14. Rights management.

15. 15 Audit tracking

Technical Spec :

Model no QY8
Sampling channel 8
Sample times 16
Longest sampling interval 99 hours 59 minutes
Minimum sampling interval 1 minute for the first time,

2-10 minutes for the rest

Continuous working hours  99 hours 59 minutes × 16
Sampling filter period <30 Second
Sample volume (or fluid volume) 1ml-100ml
Single tube distribution amount 0ml-15ml
Sampling accuracy RSD1%(10ml)
User program 99
Number of users 7 users
User level 3 class
Record keeping 128 items *366 days
Scroll to Top