Item 1 Dissolution RC810 (MDS-2008DS)
Model noMDS-2008DS
Dissolution
1. It can realize the test of basket method, paddle method, small cup method, dish method (large and small dish), and drum method (long and short tube) to meet the requirements of blank and control.
2. The machine head is electrically lifted.
3. The sampling frame is electrically lifted.
4. Automatically set the clutch.
5. Automatic, independent drug administration.
6. Two-color lighting system.
7. Multi-user management.
8. WiFi, Bluetooth, RS232, RS485 expansion interface.
9. Built-in printer.
101. Solvent monitoring.
11. Stirring speed monitoring.
12. Multi-user management.
13. Connect to the sampler.
15. High sensitivity capacitive touch screen.
16. Rights management.
17. Audit trail.
Technical spec :
| Model | MDS-2008DS |
| Cup | 8 |
| Bath Temperature | RT-45℃ |
| Solvent temperature detection | 8 channels |
| Temperature resolution | 0.01℃ |
| Stirring speed | 25RPM-250RPM |
| Stirring speed resolution | 0.1RPM |
| Dosing channel | 8 |
| Head lift method | Electrical method |
| Head lift method | Electrical method |
| Sample point resolution | 1ml |
| Lighting system | Red ligh/White light |
| Number of user | 7 users |
| User lever | 3 class |
| Progrma | 99 |
| Record keeping | 128 items *366 days |

Item 2 Sampling Model no QY8

Description
1. Use a precision glass syringe as the sampling power.
2. 2. Adopt high precision, high pressure and high chemical stability valve body.
3. 3. Built-in micro printer.
4. 4. Multi-user management.
5. 5. WiFi, Bluetooth, RS232, RS485 expansion interface 1.
6. 6. The internal use of high chemical stability of the Teflon pipeline.
7. 7. Has the same amount of rehydration function.
8. 8. With independent pipeline system, it can meet the control requirements of blank and standard for dissolution test.
9. 9. A cylindrical filter head with a pore size of 10 μm was sampled at the initial filtration, and a φ25 mm syringe filter having a pore size of 0.8 μm/0.45 μm/0.22 μm was selected as needed for the secondary filtration.A 11.16-bit test tube rack can hold up to 192 tubes.
10. 10. The sampling tube is equipped with a silicone cap to prevent evaporation and contamination of the sample.
11. 11. Can be operated online with the dissolution apparatus.
12. 12. Ampoule collection device.
13. 13. High sensitivity capacitive touch screen.
14. 14. Rights management.
15. 15 Audit tracking
Technical Spec :
| Model no | QY8 |
| Sampling channel | 8 |
| Sample times | 16 |
| Longest sampling interval | 99 hours 59 minutes |
| Minimum sampling interval | 1 minute for the first time,
2-10 minutes for the rest |
| Continuous working hours | 99 hours 59 minutes × 16 |
| Sampling filter period | <30 Second |
| Sample volume (or fluid volume) | 1ml-100ml |
| Single tube distribution amount | 0ml-15ml |
| Sampling accuracy | RSD1%(10ml) |
| User program | 99 |
| Number of users | 7 users |
| User level | 3 class |
| Record keeping | 128 items *366 days |