-25°C Freezer 100L 270L 350L 936L

BDF-25V100, BDF-25V270, BDF-25V350, BDF-25V936

The -25 ° C freezer can be used for scientific research, low temperature test of special materials, low temperature test of frozen plasma, biological materials, vaccines, biological products, etc. Applicable to scientific research institutes, electronics industry, chemical industry, hospitals, university laboratories, etc.

Technical Parameters:

Model BDF-25V100 BDF-25V270 BDF-25V350 BDF-25V936
Capacity 100L 270L 350L 936L
Temp. Range -10~-25℃
Temp. Accuracy 0.1℃
Temp. Uniformity ≤3℃ 5℃
Temp. Stability ≤3℃ 5℃
Recovery Time

(Recover to -22℃ in an ambient temp. of  25℃)

≤15min
Cooling Time

(Cool down to -25℃ in an ambient temp. of  25℃)

≤1.5h 150min
Control System Microprocessor control
Display LED
Alarm High and low temperature alarm, power failure alarm, thermostat fault alarm, door switch alarm High and low temperature alarm, thermostat fault alarm, door switch alarm, power failure alarm(8h) High and low temperature alarm, sensor fault alarm, thermostat fault alarm, power off alarm, door opening alarm, ambient temperature alarm, condenser fault alarm, filter check alarm, abnormal voltage alarm, low battery power alarm
Refrigeration Type Direct-cooling
Refrigerant R600a/48g R290/65g R290/85g R404A/320g
Compressor International famous brand compressor /1 Imported brand SECOP compressor/2
Condenser & Evaporator Side-panel type Bundy tube condenser; wire-on-tube Bundy tube evaporator Wire-on-tube Bundy tube condenser;

Built-in coil type copper tube evaporator

Finned copper tube condenser; built-in coil type copper tube evaporator
Defrost Manual defrost
Construction Polyurethane cyclopentane foam
Material Internal Material HIPS 304 stainless steel
External Material Precoated steel plate Sprayed steel plate
Door Outer door: cyclopentane integral foam outer door*1

Interior door: /

Outer door: cyclopentane integral foam outer door*1

Interior door: sprayed steel plate door*4

Outer door: cyclopentane integral foam outer door*1

Interior door: sprayed steel plate door*5

Outer door: sprayed steel plate outer door*1

Interior door: 304 stainless steel door*4

Consumption 100W 332W 312W 1000W
Power Supply AC 220V, 50Hz(Standard); 110/220V, 60Hz(Optional) AC 220V, 50Hz(Standard); 220V, 60Hz; 110V, 50/60Hz(Optional)
Casters No Yes
Shelf 3(Drawer) 3 4 3
Standard Accessory Test hole Test hole, USB interface Test hole
Optional Accessory Temperature recorder Temperature recorder, RS485, printer, inner door Temperature recorder, liquid nitrogen backup system, remote alarm function interface, USB interface
Internal Size (W*D*H) 410*440*630mm 520*567*1013mm 520*567*1266mm 1000*700*1335mm
External Size (W*D*H) 600*620*870mm 690*744*1631mm 690*744*1885mm 1304*1000*2017mm
Package Size (W*D*H) 630*645*905mm 810*860*1820mm 840*860*2050mm 1355*1000*1980mm
Net Weight 37.5kg 115kg 123kg 378kg
Gross Weight 39.5kg 132kg 145kg 413kg