Auto ELISA Processor BIOBASE1001

Introduction:
The Auto ELISA Processor BIOBASE1001 is a fully automatic detection equipment that integrates sample addition, incubation, shaking, washing, and reading. It is widely used in hospital laboratories, disease prevention and control centers, blood centers, and blood banks. , animal and plant inspection and quarantine institutions, scientific research institutions, university laboratories and other places.

  • BIOBASE1001
  • BIOBASE

Features:

1. Adopt the principle of pressure type liquid detection

2. With TIP detection, clot detection function

3. High-precision pipetting, the lowest volume can reach 10μl

4. Position sensing, real-time monitoring of gripper status

5. Multi-spacing and multi-strength adjustable grippers can be adapted to grasp and place microplates and plate covers of different sizes

6. Dual thread control, can run simultaneously with the sampling arm without interfering with each other

Technical Parameters:

Model BIOBASE1001
Sample& Reagent Unit Sample Racks 6*20 push-pull sample rack
Sampling Channel 1 channel
Liquid Level Detection Air pressure level detection, clot detection function
Tip 1000μl, 2 tip racks
Pipetting 10μl~1000μl
Pipetting Precision 100μl: CV≤1%, Accuracy≤2.5%

1000μl: CV≤0.5%, Accuracy≤1%

Reagent Position 2 reagent racks
Dilution Plate Position 1 dilution plate position with incubation and shaking
Washing Unit Washer 1 unit
Washing Head 16-channel (32-pin), double row cleaning, hanging installation, with leakage recovery
Injection Uniformity CV<1.5%
Washing Residual <2μl
Reading Unit Reading Channels 8 independent photometric channels, mono and dichromatic reading
Absorbance Range 0.000~4.000Abs
Linear Range 0.000~3.000Abs
Repeatability CV≤1.0%
Stability ≤±0.003Abs
Spectral Range 400~700nm
Optical Filters 4 standard filters(405, 450, 492, 630nm);

Total 10 filters positions

Reading Accuracy ≤±0.02Abs from 0.0 to 1.0 OD,

≤±0.03Abs from 1.0 to 2.0 OD

Sensitivity ≥0.01mg/L
Channel Difference ≤0.02Abs
Incubation Unit Incubators 2 shaking incubators
Cover Position 1 (2 covers)
Heating Method Dry heating with cover
Shaking Function Horizontal circular oscillation, 1-3 levels adjustable, amplitude 2.5mm
Temperature Range RT to 60 °C
Temperature Uniformity ±0.5℃
Temperature Fluctuation ±0.5℃
Data Management Software Above Windows 7 system
LIS System Bi-direction, support HL7 protocol
Results Absorbance and results reviewable by software
Printer External optional
Built-in Scanner Optional
Other Function Biosafety Protection Optional (Negative pressure working zone, HEPA filter)
Disinfection UV lamp
Lighting LED
IAP Function Firmware can be upgraded online at any time
Working Condition Power Supply AC220V±10%, 50/60Hz(Standard); 110V±10%, 60Hz(Optional)
Temperature 10~40℃
Humidity 30~80%
Size & Weight External Size (W*D*H) 870*700*885mm
Net Weight 180kg
Package Size(W*D*H) Machine: 1018*828*1130mm

Accessories: 750*1000*700mm

Gross Weight Machine: 160kg

Accessories: 80kg