Scientz-04/09/11L Stick Blender

Germfree Homogenizer,also known as flap homogenizer, is widely used in the homogenization treatment for animal tissue and biological samples, also used for the following testing areas: food, pharmaceutial, cosmetics, clinics molecule, toxin and bacteria,particularly suitable for preparation of…

Aseptic homogenizer for biomedicine; food industry; daily care products; paint ink; nanomaterials; petrochemical; printing and dyeing auxiliaries; paper industry; pesticides and fertilizers; plastics and rubber; power electronics; An example of a sterile homogenizer is described below.

Application of homogenizer in soy milk: When homogenized, soy milk is pressed out from the slit of the homogenizing valve under high pressure. The fat globule, the constant temperature homogenizer protein and the like are finely divided by the shearing force, the impact force and the cavitation effect. A uniform dispersion is formed. Prevent fat from floating, protein precipitation, increase the gloss of soy milk, and improve the stability of soy milk.

The homogenization effect of soymilk is subject to homogenization pressure. The three factors of homogenization temperature and number of homogenization are affected. The homogenization pressure is limited by the equipment. Soy milk production can be homogenized with a pressure of 20~30MPa. When the temperature is homogeneous, the temperature is generally controlled between 55 and 65 °C. The number of homogenizations is 1~2 times.

The homogenization process can be placed before the soy milk is sterilized. It can also be placed after sterilization. Both arrangements have their own advantages and disadvantages. The homogenization is placed before sterilization, and the sterilization process can destroy the homogenization effect to some extent. Soy milk is prone to oil lines. However, the use of this process reduces the chance of contamination after sterilization. Storage is safer. Equipment costs are relatively low. And after the homogenized soy milk enters the sterilizer, it is not easy to scale. If the homogenization is placed after sterilization, the above situation is just the opposite.

The application of the aseptic homogenizer in the raw milk: breaking the large fat globules in the milk into small fat globules under strong mechanical action of 16.7-20.6 MPa. Disperse it evenly in the milk. It can effectively prevent fat balls from floating up. In the production of pasteurized milk. The location of the general homogenizer is in the first heat recovery section of the sterilization. In the production of indirectly heated UHT milk, the homogenizer is located prior to sterilization. In the production of directly heated UHT milk. The homogenizer is located after sterilization. Therefore, a sterile homogenizer should be used. Homogenization not only prevents the fat globule from floating, but also has other advantages: the homogenized cow’s milk fat globule is reduced in diameter and easily digested and absorbed by the human body. Homogenization softens the milk protein clot. Promote digestion and absorption. In the production of enzyme cheese, homogenization can accelerate the coagulation of milk, and the flavor of dairy products is more consistent. 

Model Scientz-04 Scientz-09 Scientz-11L
Timing 30、180、600sor∞(continuous working转) 0.1 ~   99min(to 0.1mins step )
Rap Speed 6-9time/Sec 3〜12times/Sec(to   0.1minutes step)Display the actual rattling number, the   system automatically adjusts the slap speed

 

Capacity 3-400ml 3-400ml 3-400ml
Ratting Box  Stainless Steel  Stainless Steel  Stainless Steel
Parameter   storage No More than 10   groups

of multi-stage   programming

 More than 10 groups of multi-stage programming
Power 300W 300W 500W
Display  LCD  Digital  LCD
Temperature   control No No Room temperature–50   OC to set,temperature display
UV Disinfection No No Yes
Sterile   bag 17 * 30cm 17*30cm 17*30cm
 Net Weight 22.5Kg 18.5Kg 18.5Kg
Protection   Device With   auto-stop anti-trap feature, Removable windows and adjustable slap board,   toughened glass security door. Removable windows and adjustable   slap board, toughened glass security door
Dimensions 400 *420*260mm 420*245*340mm 420*245*340mm

Scientz-11L.jpg

SCIENTZ-09 拍打式均质器.jpeg

photobank(101).jpg

Scroll to Top