Automated Microbiology Glowth Curve Analysis Stystem

The fully automatic microbial growth curve analyzer is a fully automated instrument that understands the growth of microorganisms by measuring the turbidity of the sample. This product can be used in the research of microbial strains, optimization of culture conditions, and high-throughput screening and evaluation of drugs. All microorganisms (bacteria, fungi, yeasts, cells and algae) multiply in the culture medium and produce turbidity. Any turbidity and color change in the traditional test tube test can be done with the “micro test tube” in the honeycomb panel. The fully automatic growth curve analyzer can make work more efficient and can save a lot of medium and consumables (Petri dishes, test tubes, etc.). The long-term culture of microorganisms is realized by

The fully automatic microbial growth curve analyzer is a fully automated instrument that understands the growth of microorganisms by measuring the turbidity of the sample. This product can be used in the research of microbial strains, optimization of culture conditions, and high-throughput screening and evaluation of drugs. All microorganisms (bacteria, fungi, yeasts, cells and algae) multiply in the culture medium and produce turbidity. Any turbidity and color change in the traditional test tube test can be done with the “micro test tube” in the honeycomb panel. The fully automatic growth curve analyzer can make work more efficient and can save a lot of medium and consumables (Petri dishes, test tubes, etc.). The long-term culture of microorganisms is realized by high-precision temperature control and high-speed shaking of the microplate, and the multi-strain culture of aerobic bacteria and anaerobic bacteria can be realized by gas circuit control. Analysis, the use of advanced denoising algorithms can provide more accurate microbial growth curves.

Two working modes are available: incubation mode and absorbance test mode:

1. Cultivation mode: Provide the environment required for the growth of microorganisms, and at the same time, the absorbance of the sample is regularly detected and recorded at the specified wavelength.

2. Absorbance test mode: The full spectrum absorbance test can be performed on the specified sample, and the absorbance values of different wavelengths can be given.

The system is mainly composed of three parts, namely microbial growth curve analyzer, computer PC, and mobile APP (expansion function).

The equipment is mainly composed of six subsystems: optical detection system, temperature control system, vibration control system, pneumatic control system, embedded system and host computer system.

8ca4423290080b4d73f4f96421c73741

configuration list

1. One MGC-200 host ;

2. 1 hot cover for 96 -well plate;

3. 50 96 culture plates;

4. 1 power cord;

5. 1 data cable;

6 .1 manual;

7 .1 copy of the warranty card;

8 .PC software (electronic version) 1 copy;

9. 1 air transport safe;

Performance parameters

function type specific function specific requirements
Dimensions 510×655×350(W * D * H)
Performance Detection wavelength 300-850 nm
Minimum resolution 1nm
Absorbance range Maximum value 5.0 OD
Linearity error <2%
light source Xenon lamp
Light source life 1 billion times
sampling interval 5 -360 minutes can be set
work time 1 ~ 1600h
Microplate Type 9 6 -well plate, 4 8 -well plate, 2 4 -well plate, 1 2 -well plate
Maximum number of boards 2 pieces
Maximum culture volume 96-well plate 0.2ml; 4 8 -well plate 1.0ml; 2 4 -well plate 2.0ml; 1 2 -well plate 4.0ml ;
culture temperature 15~ 60 °C (at room temperature 25°C)
Temperature control accuracy ± 0.1 degrees
heating rate 2.5 degrees/min
Shaking method circular shaking
Vibration amplitude 3mm
Shaking speed 200-1250rpm
Hot cover to prevent condensation YES
Multi-wavelength detection YES
Single hole multi-point detection YES
Reference channel selectable YES
Sterilization module YES
Withholding dark current function YES
Midway temperature change function YES
CO2 concentration detection /
O2 concentration detection /
humidity monitoring YES
Hot Lid Type Identification YES
Optical path normalization YES
Air supply abnormal prompt /
Ease of use Quick Change of Orifice Plates Quick plate change without tools
Troubleshooting The alarm code is detailed and can be quickly determined as the cause of the failure
interface operation User-friendly interface, users can get started quickly, with fast running function
Other software functions communication WIFI ( reserved extended function)
Main interface Parameter setting interface, status display interface, sample selection interface, data display interface, and result analysis interface.
more menu Startup interface, login interface, initialization interface and debugging interface
Alarm function Equipment operation failure alarm

Performance characteristics

* 1. Using xenon lamp as the light source, high energy, no need to preheat, high resolution, high sensitivity, fast detection, at the same time, the light source has good stability and long life, and does not need to be replaced frequently;

* 2. Using high – performance optical absorption detection system, it can perform absorbance detection on any wavelength band within the wavelength range of 300-850nm, providing solutions for quantitative detection of various biomass. Full spectrum scanning can be achieved, and the optimal wavelength suitable for the sample to be tested can be automatically analyzed;

* 3. The single-hole multi-point detection technology can be selected, and the data error caused by the single-point detection is eliminated by the algorithm, and the data results are more accurate;

4. The maximum shaking speed can reach 1250rpm, so that the liquid in a small volume can be fully mixed, and the shaking culture of microorganisms in 96, 48 , 24 , and 12 -well culture plates can be realized;

5. With standard preset program, simple operation and convenient data processing. At the same time, it supports customer-defined templates for personalized operation settings and data analysis;

*6 .It has a hot cover anti-condensation design, with cooling and heating modules, and the temperature control range is 15-60°C at room temperature. The temperature can be changed during the microbial culture to facilitate the accumulation of specific metabolites;

7. It is convenient to replace the orifice plate quickly without tools;

8. With the function of fault diagnosis, the alarm code can quickly find out the cause of the fault in time;

9. Controlled by PC software, the interface is friendly and intuitive, users can get started quickly, and it has the function of quick operation. The software displays parameter setting interface, status display interface, sample selection interface, data display interface, result analysis interface, etc.;

10. Reserved communication WIFI expansion function;