Turbocharge Your Research! MGC Series Microbial Growth Curve Analyzer-Your Ultimate Lab Sidekick for REAL-TIME Microbial Insights!
🔍 Why MGC Series?
✔ All-in-One Automation: Sample in and Results out. No overnight lab sessions required!
✔ Labor Free: Cultivate + detect hands-free-no manual sampling, zero contamination risk!
✔ Full Spectrum Scan: 300-850nm wavelength range for comprehensive spectral detection
✔ High-Speed Shaking (200-1250 rpm): Crush sedimentation issues! Perfect for yeast & stubborn cultures
✔ Smart Gas Control: Precision O₂/CO₂/anaerobic settings-tame even the fussiest microbes!
Why We Outshine Competitors?
Broad Spectrum Detection (300-850nm): No more single-wavelength blind spots!
Flexible Consumables: 12/24/48/96-well plates-scale your experiments effortlessly!
Gas-Sipping Design: Uses 90% less gas than clunky incubators-budget-friendly science!
Who’s Using It? Where?
Labs & Academia: Synthetic Biology, Food Science, Microorganism, Metabolic Engineering, etc.
Hospitals: Rapid pathogen growth analysis for precision antimicrobial therapy!
Biotech & Pharma: Probiotic R&D, Fermentation Optimize, preservative testing-data-driven decisions!
![]() |
![]() |
|
Escherichia coli is one of the most common microor
ganisms in the laboratory. It is a Gram-negative short
bacillus with a size of 0.5 × 1-3 μm. It has perinatal
flagella, can move, and has no spores.
|
Fission yeast is a typical biological model of cell
division and is widely used in cell biology research.
It is 4~5×8~15μm in size, easy to settle, and
requires a high speed to mix.
|
Lactobacillus rhamnosus is an anaerobic, acid-resistant,
non-spore-forming Gram-positive probiotic with a size of
0.8~1.0×2~4μm. It is usually cultured statically and easy to
aggregate and low-speed rotational culture in MGC-200 can
avoid agglomeration.
|
Lactobacillus plantarum is a kind of lactic acid bacteria,
anaerobic or facultative anaerobic, 0.9~1.2×3~8μm in
size, round-ended straight bacteria. Usually lacks flagella,
but is able to move. Gram positive, non-spore forming.
|
![]() |
![]() |
![]() |
![]() |
|
Escherichia coli growth curve
|
Fission yeast growth curve
|
Lactobacillus rhamnosus growth curve
|
Lactobacillus plantarum growth curve
|
|
(Incubation temperature 36°C, 96-well plate, incuba
tion volume 200μL, incubation time 24hr, interval
time 10min)
|
(Incubation temperature 30°C, 48-well plate,
incubation volume 500μL, incubation time 24hr,
interval 30min)
|
(Incubation temperature 37°C, 12-well plate, incubation
volume 2400μL, incubation time 72hr, interval 30min)
|
(Incubation temperature 37°C, 12-well plate, incubation
volume 2400μL, incubation time 24hr, interval 30min)
|

| Model | MGC-200 | MGC-200pro |
| Dimensions(W*D*H) | 510×655×350mm | 510×655×350mm |
| Detection wavelength | 300-850nm | 300-850nm |
| Microbial culture container | Cell culture plate/ELISA plate | Cell culture plate/ELISA plate |
| Number of channels | 2 board positions,up to 192 channels | 2 board positions,up to 192 channels |
| Volume limit of culture medium | 2.5mL | 2.5mL |
| Light source | Xenon lamp,30 years | Xenon lamp,30 years |
| Temperature control range | 15-60℃(at room temperature 25℃) | 15-60℃(at room temperature 25℃) |
| Shaking speed | 200-1250 rpm | 200-1250 rpm |
| Detection method | Single hole multi-point detection | Single hole multi-point detection |
| Absorbance range | Highest value 8.0 OD | Highest value 8.0 OD |
| Detection interval | 5-360 minutes can be set | 5-360 minutes can be set |
| longest incubation time | 1600 hours | 1600 hours |
| Authority management | Sub-user and administrator permissions | Sub-user and administrator permissions |
| Equipment operation failure alarm | YES | YES |
| Sterilization module | UV sterilization | UV sterilization |
| Full spectrum scan | YES | YES |
| Thermal Lid Anti-Condensation | YES | YES |
| Humidity monitoring | YES | YES |
| Mid-way temperature change function | YES | YES |
| Reference channel selection | YES | YES |
| CO2 concentration detection | NO | YES |
| 02 concentration detection | NO | YES |
| Gas control | NO | YES |
| Lighting function | NO | YES |













