HL Series -100°~100° Process Temperature Control System (Heating And Cooling)

The use of fully closed pipe design, reduce the demand for thermal fluid, improve the heat utilization rate of the system, to achieve rapid temperature rise and fall. The thermal conductivity medium in the expansion vessel does not participate in the cycle, which can reduce the risk of the thermal conductivity medium absorbing water and volatilization during operation.

Category Tag
Products Description
-100100

HL Series -100°~100° Process Temperature Control System

The use of fully closed pipe design, reduce the demand for thermal fluid, improve the heat utilization rate of the system, to achieve rapid temperature rise and fall. The thermal conductivity medium in the expansion vessel does not participate in the cycle, which can reduce the risk of the thermal conductivity medium absorbing water and volatilization during operation.
Fully Enclosed Circulation

No need to change the heat transfer medium, improve heat transfer efficiency and reduce the risk of heat transfer medium evaporation and moisture absorption.

Sinkless design

Faster cooling rate

Intuitive Level Viewer

Convenient for users to observe the liquid level

High Temperature Cooling

Design temperature range can be opened cooling continuous cooling high temperature 200 ℃ directly open the compressor cooling

Over temperature protection

Automatically cut off the heating power after exceeding the user’s set value

Programmed temperature control

Multi-temperature point program control

Application Areas
1 Reaction still:
1691023942737629
The reactor is widely used in petroleum, chemical, rubber, pesticide, dye, medicine, food and other production users and various research and experimental projects, complete hydrolysis,neutralization, crystallization, distillation, evaporation, storage, hydrogenation, polymerization,condensation, heating mixing, constant temperature reaction and other processes.
During temperature control, the temperature is stable, the rate of rising and cooling is fast, and
the temperature of the reaction process can be recorded in real time.
2 Microchannel reactor:
Microchannel reactor
Microchannel reactor can perform different types of reactions, suitable for fast (strong exothermic) reaction, liquid reaction, gas-liquid reaction, absorption and exothermic reaction, can be used for nitration reaction, sulfonation reaction, oxidation reaction, peroxidation reaction, alkylation reaction, amination reaction, photogasification reaction and other reaction processes. It can be used for micro-reaction process development and fine chemical synthesis.
The equipment has a wide temperature range, high precision intelligent temperature control, single fluid temperature control, no need to replace the thermal medium, efficient and stable.

 

New energy vehicle testingproduct-1462-205

  In the new energy vehicle industry, temperature control is mainly used in testing, testing benches and material testing. Most of the components in the car are tested under extreme temperature changes to ensure normal operation and reliability before being put into practical use. Testing many different components on a test stand is important for improving quality and reliability. Simulating very wide temperature ranges as well    as extreme ambient temperatures is an important part of material testing.
  Multiple samples can be controlled at the same time, and the control system can record and export the temperature data during the test process, which can meet the test conditions of most components under extreme temperature changes

Application

automobile-production-line1

New Energy Vehicle Testing

– Rapid aging tests in the development of batteries and electrical components

– Final Inspection Testing of Electric Vehicle Devices

- Simulation of extreme conditions in space

Aerospace industries

– Simulation of extreme conditions in space

– Aging tests for devices and materials

– Functional testing of electronics units

product-368-253

Chemical and pharmaceutical

– Microchannel reaction synthesis temperature control

– Dynamic temperature control of reactors

– Temperature control of low-temperature reactions in metal-organic synthesis

research-52970281

Bioproduction

– Thermostatic control of biological disposable reactors

– Rapid cooling of reaction processes

– Control of the amplification production process

Technical Parameters

model HL25W-820 HL35W-820 HL55W-820 HL75W-820 HL100W-820
Heating power 2.5kW 3.5kW 5.5kW 7.5kW 10.0kW
Cooling capacity 200°C 2.5kW 3.5kW 5.5kW 7.5kW 100kW
Cooling capacity 100°C 2.5kW 3.5kW 5.5kW 7.5kW 10.0kW
Cooling capacity 20°C 2.5kW 3.5kW 5.5kW 7.5kW 10.0kW
Cooling capacity -60°C 1.0kW 1.4kW 1.6kW 3.0kW 3.3kW
Cooling capacity -75°C 0.3kW 0.42kW 0.7kW 1.3kW 1.4kW
Circulation pump flow Max20L/min Max25L/min Max35L/min Max50L/min Max60L/min
Circulation pump pressure 2bar 2bar 2bar 2bar 2bar
compressor Embraco Emerson Copeland
Expansion valve Danfoss
Thermal medium interface DN15 DN20 DN20 DN20 DN25
20 degrees cooling water demand 1.2m³/h 1.5m³/h 1.8m³/h 2.6m³/h 3.2m³/h
1.5bar~4bar 1.5bar~4bar 1.5bar~4bar 1.5bar~4bar 1.5bar~4bar
Cooling water connection DN15 DN20 DN20 DN20 DN25
Dimensions (mm) Water-cooled 4006001150 4506001150 5006501250 5507001600 6506701650
Dimensions mm Air Cooling 4006501250 4506501300 5506501400 5507501650 6507001650
Weight Water Cooling 170kg 185kg 265kg 305kg 340kg
Weight Air Cooled 200kg 225kg 300kg 340kg 380kg
power supply AC 380V 50Hz AC 380V 50Hz AC 380V 50Hz AC 380V 50Hz AC 380V 50Hz
Total Power 6.5kW(max) 10kW(max) 13kW(max) 17kW(max) 22kW(max)

 

model HL25W-820 HL35W-820 HL55W-820 HL75W-820 HL100W-820
model HL150W-820 HL250W-820 HL380W-820 HL600W-820 HL950W-820
Heating power 15kW 25kW 38kW 60kW 95kW
Cooling capacity 200°C 15kW 25kW 38kW 60kW 95kW
Cooling capacity 100°C 15kW 25kW 38kW 60kW 95kW
Cooling capacity 20°C 15kW 25kW 38kW 60kW 95kW
Cooling capacity -60°C 5.8kW 10kW 16kW 23kW 32kW
Cooling capacity -75°C 2.4kW 5kW 8kW 11kW 14kW
Circulation pump flow Max110L/min Max150L/min Max200L/min Max250L/min Max400L/min
Circulation pump pressure 2.5bar 2.5bar 2.5bar 2.5bar 2.5bar
compressor Embraco Italy Duolin/Bitzer/Fujihao
Expansion valve Danfoss
Thermal medium interface DN25 DN32 DN40 DN40 DN50
20 degrees cooling water demand 7m³/h 10m³/h 14m³/h 20m³/h 30m³/h
1.5bar~4bar 1.5bar~4bar 1.5bar~4bar 1.5bar~4bar 1.5bar~4bar
Cooling water interface DN25 DN32 DN40 DN40 DN50
Dimensions (mm) Water-cooled 7008001650 10009501650 10009501750 200012501750 200012501750
Dimensions mm Air Cooling 7507501800 / / / /
Weight Water Cooling 380kg 980kg 1150kg 1380kg 1750kg
Weight Air Cooled / / / / /
power supply AC 380V 50Hz AC 380V 50Hz AC 380V 50Hz AC 380V 50Hz AC 380V 50Hz
Total Power 33kW(max) 56kW(max) 90kW(max) 140kW(max) 180kW(max)
Scroll to Top