HL Series -25°~200° Process Temperature Control System

The use of fully closed pipe design, reduce the demand for thermal fluid, improve the heat utilization rate of the system, to achieve rapid temperature rise and fall. The thermal conductivity medium in the expansion vessel does not participate in the cycle, which can reduce the risk of the thermal conductivity medium absorbing water and volatilization during operation.

Category Tag
Products Description

-25200

HL Series -25°~200° Process Temperature Control System

The use of fully closed pipe design, reduce the demand for thermal fluid, improve the heat utilization rate of the system, to achieve rapid temperature rise and fall. The thermal conductivity medium in the expansion vessel does not participate in the cycle, which can reduce the risk of the thermal conductivity medium absorbing water and volatilization during operation.
Fully Enclosed Circulation

No need to change the heat transfer medium, improve heat transfer efficiency and reduce the risk of heat transfer medium evaporation and moisture absorption.

Sinkless design

Faster cooling rate

Intuitive Level Viewer

Convenient for users to observe the liquid level

High Temperature Cooling

Design temperature range can be opened cooling continuous cooling high temperature 200 ℃ directly open the compressor cooling

Over temperature protection

Automatically cut off the heating power after exceeding the user’s set value

programmed temperature control

Multi-temperature point program control

Application Areas
1

Reaction still:

1691023942737629

The reactor is widely used in petroleum, chemical, rubber, pesticide, dye, medicine, food and other production users and various research and experimental projects, complete hydrolysis,neutralization, crystallization, distillation, evaporation, storage, hydrogenation, polymerization,condensation, heating mixing, constant temperature reaction and other processes.
During temperature control, the temperature is stable, the rate of rising and cooling is fast, and
the temperature of the reaction process can be recorded in real time.
2

Microchannel reactor:

Microchannel reactor

Microchannel reactor can perform different types of reactions, suitable for fast (strong exothermic) reaction, liquid reaction, gas-liquid reaction, absorption and exothermic reaction, can be used for nitration reaction, sulfonation reaction, oxidation reaction, peroxidation reaction, alkylation reaction, amination reaction, photogasification reaction and other reaction processes. It can be used for micro-reaction process development and fine chemical synthesis.
The equipment has a wide temperature range, high precision intelligent temperature control, single fluid temperature control, no need to replace the thermal medium, efficient and stable.

 

New energy vehicle testingproduct-1462-205

  In the new energy vehicle industry, temperature control is mainly used in testing, testing benches and material testing. Most of the components in the car are tested under extreme temperature changes to ensure normal operation and reliability before being put into practical use. Testing many different components on a test stand is important for improving quality and reliability. Simulating very wide temperature ranges as well    as extreme ambient temperatures is an important part of material testing.
  Multiple samples can be controlled at the same time, and the control system can record and export the temperature data during the test process, which can meet the test conditions of most components under extreme temperature changes

Application

New Energy Vehicle Testing

– Rapid aging tests in the development of batteries and electrical components

– Final Inspection Testing of Electric Vehicle Devices

automobile-production-line1

Aerospace industries

– Simulation of extreme conditions in space

– Aging tests for devices and materials

– Functional testing of electronics units

- Simulation of extreme conditions in space

Chemical and pharmaceutical

– Microchannel reaction synthesis temperature control

– Dynamic temperature control of reactors

– Temperature control of low-temperature reactions in metal-organic synthesis

product-368-253

Bioproduction

– Thermostatic control of biological disposable reactors

– Rapid cooling of reaction processes

– Control of the amplification production process

research-52970281

Technical Parameters

Model HL25-220 HL35-220 HL55-220 HL75-220 HL100-220
Heating power 2.5kW 3.5kW 5.5kW 7.5kW 10kW
Cooling capacity 200℃ 2.5kW 3.5kW 5.5kW 7.5kW 10kW
100℃ 2.5kW 3.5kW 5.5kW 7.5kW 10kW
20℃ 2.5kW 3.5kW 5.5kW 7.5kW 10kW
-5℃ 2kW 3kW 4.5kW 6.6kW 8kW
-20℃ 1.0kW 1.8kW 2.8kW 3.8kW 4.6kW
Circulating pump Flow Max30L/min Max30L/min Max42L/min Max56L/min Max56L/min
Pressure 1.5bar 1.5 bar 2.0 bar 2.0 bar 2.0 bar
Compressor SECOP EMERSON COPELAND
Expansion valve DANFOSS
Thermal medium interface size DN15 DN20 DN20DN20 DN25
20c cooling water demand 0.6m³/h 0.8m³/h 1m³/h 1.2m³/h 1.6m³/h
1 . 5bar~4bar 1 . 5bar~4bar 1 . 5bar~4bar 1 . 5bar~4bar 1 . 5bar~4bar
Cooling water interface size G1/2 G1/2 G3/4 G3/4 G3/4
Dimension mm Water-cooling 400*600*1150 400*600*1150 500*680*1250 550*700*1600 500*680*1250
Air-cooled 400*600*1250 450*650*1300 550*750*1400 570*750*1500 650*700*1650
Weight Water-cooling 100kg 135kg 160kg 205kg 250kg
Air-cooled 115kg 165kg 285k 230k 280kg
Power supply/Voltage AC 220V 50HZ AC 380V 50HZ AC 380V 50HZ AC 380V 50HZ AC 380 V50HZ
Total power 4kW(max) 6kW(max) 8kW(max) 11kW(max) 14kw(max)

 

Model HL150-220 HL250W-220 HL380W-220 HL600W-220 HL950W-220
Heating power 15kW 25kW 38kW 60kW 95kW
Cooling capacity 200℃ 15kW 25kW 38kW 60kW 95kW
100℃ 15kW 25kW 38kW 60kW 95kW
20℃ 15kW 25kW 38kW 60kW 95kW
-5℃ 12kW 19kW 30kW 46kW 70kW
-20℃ 7kW 12kW 16kW 22kW 32kW
Circulating pump Flow Max110L/min Max120L/min Max150L/min Max300L/min Max400L/min
Pressure 2.5bar 2.5bar 2.5bar 2.5bar 2.5bar
Compressor EMERSON COPELAND DORIN/BITZER/FRASCOLD
Expansion valve DANFOSS EMERSON COPELAND/DANFOSS
Thermal medium interface size DN32 DN32 DN40 DN40 DN50
20c cooling water demand 2m³/h 6m³/h 10m³/h 14m³/h 20m³/h
1 . 5bar~4bar 1 . 5bar~4bar 1 . 5bar~4bar 1 . 5bar~4bar 1 . 5bar~4bar
Cooling water interface size G1 DN32 DN40 DN50 DN65
Dimension mm Water-cooling 700*800*1650 1000*950*1650 1000*950*1750 2000*1250*1750 2000*1250*1750
Air-cooled 750*750*1800 / / / /
Weight Water-cooling 280kg 480kg 750kg 1000k 1250kg
Air-cooled 300kg / / / /
Power supply/Voltage AC 380V 50HZ AC 380V 50HZ AC 380V 50HZ A C380V 50HZ AC 380V 50HZ
Total power 21kW(max) 34kW(max) 51 kW(max) 78kW(max) 120kW(max)

 