MGC-200 Series Microbial Growth Curve Analyzer

Microbial growth curve analyzer MGC-200 series is a fully automated instrument, which can realize real-time detection of microbial growth status under different growth temperatures, different medium components, and different light combinations, and automatically draw growth curves to provide a powerful boost for microbial research . The whole process does not require personnel to be on duty, does not require frequent sampling, completely eliminates the risk of contamination, and truly liberates manpower.

High energy long life xenon lamp

product-177-180

As a light source,xenonlamp has the

advantages ofhigh energy and no need for

preheating Sensitivity and rapid detection lay the foundation.At the same time,the light

sourcehas goodstability and long life,and does not need to be replaced frequenty.

product-251-3

Accurate detection method

product-179-181

Using single hole multi-point detection, provides more accurate and repeatable detec- tion data than traditional center readings.

product-244-3

High speed vibration

product-179-180

The highest shaking speed can

reach1250rpm,so that the liquidin a small volume can be fully mixed,and the shaking culture ofmicroorganisms in a96-wellplate can be realized.

High throughput

product-180-180

With twoculture plate positions,a variety of adapters are compatible with culture plates of different specifications, and canprocess upto192 samples at the same time.

TECHNICAL SPECIFICATIONS
Model MGC-200 MGC-200pro
Dimensions(W*D*H) 510×655×350mm 510×655×350mm
Detection wavelength 300-850nm 300-850nm
Microbial culture container Cell culture plate/ELISA plate Cell culture plate/ELISA plate
Number of channels 2 board positions,up to 192 channels 2 board positions,up to 192 channels
Volume limit of culture medium 2.5mL 2.5mL
Light source Xenon lamp,30 years Xenon lamp,30 years
Temperature control range 15-60℃(at room temperature 25℃) 15-60℃(at room temperature 25℃)
Shaking speed 200-1250 rpm 200-1250 rpm
Detection method Single hole multi-point detection Single hole multi-point detection
Absorbance range Highest value 8.0 OD Highest value 8.0 OD
Detection interval 5-360 minutes can be set 5-360 minutes can be set
longest incubation time 1600 hours 1600 hours
Authority management Sub-user and administrator permissions Sub-user and administrator permissions
Equipment operation failure alarm YES YES
Sterilization module UV sterilization UV sterilization
Full spectrum scan YES YES
Thermal Lid Anti-Condensation YES YES
Humidity monitoring YES YES
Mid-way temperature change function YES YES
Reference channel selection YES YES
CO2 concentration detection NO YES
02 concentration detection NO YES
Gas control NO YES
Lighting function NO YES
Scroll to Top